BEAM DYNAMICS AND EXPERIMENT OF CPHS LINAC *

Similar documents
The PEFP 20-MeV Proton Linear Accelerator

The ESS Accelerator. For Norwegian Industry and Research. Oslo, 24 Sept Håkan Danared Deputy Head Accelerator Division Group Leader Beam Physics

Studies on an S-band bunching system with hybrid buncher

PRESENT STATUS OF J-PARC

Proton Engineering Frontier Project

The Construction Status of CSNS Linac

COMMISSIONING SCENARIOS FOR THE J-PARC ACCELERATOR COMPLEX

Linac 4 Instrumentation K.Hanke CERN

Design of the linear accelerator for the MYRRHA project

ESS: The Machine. Bucharest, 24 April Håkan Danared Deputy Head Accelerator Division. H. Danared Industry & Partner Days Bucharest Page 1

OPERATIONAL EXPERIENCE AT J-PARC

Commissioning of Accelerators. Dr. Marc Munoz (with the help of R. Miyamoto, C. Plostinar and M. Eshraqi)

The FAIR plinac RF Systems

Particle Beam Production - A Synchrotron-Based System - Prof. Dr. Thomas Haberer Scientific-technical Director Heidelberg Iontherapy Center

Evaluation of Performance, Reliability, and Risk for High Peak Power RF Sources from S-band through X-band for Advanced Accelerator Applications

4.4 Injector Linear Accelerator

DESIGN OF 1.2-GEV SCL AS NEW INJECTOR FOR THE BNL AGS*

100 MeV H - CYCLOTRON DEVELOPMENT AND 800 MeV PROTON CYCLOTRON PROPOSAL*

APT Accelerator Technology

Screen investigations for low energetic electron beams at PITZ

Production of quasi-monochromatic MeV photon in a synchrotron radiation facility

HIGH-INTENSITY PROTON BEAMS AT CERN AND THE SPL STUDY

Upgrading LHC Luminosity

CLIC Feasibility Demonstration at CTF3

Design Studies For The LCLS 120 Hz RF Gun Injector

LENS Operating Experience

Characterizing Transverse Beam Dynamics at the APS Storage Ring Using a Dual-Sweep Streak Camera

DARK CURRENT IN SUPERCONDUCTING RF PHOTOINJECTORS MEASUREMENTS AND MITIGATION

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

HIGH POWER BEAM DUMP AND TARGET / ACCELERATOR INTERFACE PROCEDURES *

Oak Ridge Spallation Neutron Source Proton Power Upgrade Project and Second Target Station Project

STATUS OF THE SwissFEL C-BAND LINAC

PEP II Design Outline

Beam Loss Detection for MPS at FRIB

BEAM DIAGNOSTICS IN THE CNAO INJECTION LINES COMMISSIONING

TITLE PAGE. Title of paper: PUSH-PULL FEL, A NEW ERL CONCEPT Author: Andrew Hutton. Author Affiliation: Jefferson Lab. Requested Proceedings:

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Low-Energy Electron Linacs and Their Applications in Cargo Inspection

The Beam Test Facility at the SNS

45 MW, 22.8 GHz Second-Harmonic Multiplier for High-Gradient Tests*

THE OPERATION EXPERIENCE AT KOMAC*

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

Beam Instrumentation for CTF3 and CLIC

STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR

Jefferson Lab Experience with Beam Halo, Beam Loss, etc.

Hall-B Beamline Commissioning Plan for CLAS12

LHC Beam Instrumentation Further Discussion

Workshop on Accelerator Operations August 6-10, 2012 Glen D. Johns Accelerator Operations Manager

Summary of the 1 st Beam Line Review Meeting Injector ( )

LIGHT PROTON THERAPY PROJECT

Development of beam-collision feedback systems for future lepton colliders. John Adams Institute for Accelerator Science, Oxford University

FIRST SIMULTANEOUS TOP-UP OPERATION OF THREE DIFFERENT RINGS IN KEK INJECTOR LINAC

COMMISSIONING AND FIRST RESULTS OF THE ELECTRON BEAM PROFILER IN THE MAIN INJECTOR AT FERMILAB*

The European Spallation Source

Test beam data analysis for the CMS CASTOR calorimeter at the LHC

Beam instrumentation at the 1-MW proton J-PARC RCS

Advanced Photon Source - Upgrades and Improvements

Preparations for Installation, Testing and Commissioning based on Experience at CERN, SNS and Siemens

A Fifteen Year Perspective on the Design and Performance of the SNS Accelerator

Progress of Beam Instrumentation in J-PARC Linac

CERN S PROTON SYNCHROTRON COMPLEX OPERATION TEAMS AND DIAGNOSTICS APPLICATIONS

TOWARDS THE COMMISSIONING OF J-PARC

Activities on FEL Development and Application at Kyoto University

A HIGH-POWER SUPERCONDUCTING H - LINAC (SPL) AT CERN

Report on the LCLS Injector Technical Review

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

2 Work Package and Work Unit descriptions. 2.8 WP8: RF Systems (R. Ruber, Uppsala)

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Beam Commissioning of GRIFFIN Beam Line

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

PROJECT DESCRIPTION. Longitudinal phase space monitors for the ILC injectors and bunch compressors

High Brightness Injector Development and ERL Planning at Cornell. Charlie Sinclair Cornell University Laboratory for Elementary-Particle Physics

ESS Linac WP8 Radio Frequency Systems and Test Facilities

Mechanical aspects, FEA validation and geometry optimization

Summary report on synchronization, diagnostics and instrumentation

TESLA FEL-Report

A Facility for Accelerator Physics and Test Beam Experiments

Time-resolved measure technique for electron beam envelope basing on synchronous framing and streaking principle*

Present Status of the Accelerator System in the IFMIF/EVEDA Project

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

Dark current and multipacting trajectories simulations for the RF Photo Gun at PITZ

PROTON DRIVER CHAPTER IV

SPEAR 3: Operations Update and Impact of Top-Off Injection

LCLS RF Reference and Control R. Akre Last Update Sector 0 RF and Timing Systems

OF THIS DOCUMENT IS W8.MTO ^ SF6

THE NEXT LINEAR COLLIDER TEST ACCELERATOR: STATUS AND RESULTS * Abstract

Status and Plans for PEP-II

The sc cw-linac project TASCA2012, S. Mickat, LINAC

P. Adamson, Fermi National Accelerator Laboratory, Batavia, IL 60510, USA. Abstract

RF considerations for SwissFEL

Precision measurements of beam current, position and phase for an e+e- linear collider

III. Proton-therapytherapy. Rome SB - 3/5 1

The linear proton accelerator for the MYRRHA-ADS

Review Report of The SACLA Detector Meeting

EPJ Web of Conferences 95,

Basic rules for the design of RF Controls in High Intensity Proton Linacs. Particularities of proton linacs wrt electron linacs

Status of RF Power and Acceleration of the MAX IV - LINAC

ESS Linac WP8 Radio Frequency Systems and Test Facilities

Development of High Power Vacuum Tubes for Accelerators and Plasma Heating

RF plans for ESS. Morten Jensen. ESLS-RF 2013 Berlin

Transcription:

BEAM DYNAMICS AND EXPERIMENT OF CPHS LINAC * L. Du #, C.T. Du, X.L. Guan, C.X. Tang, R. Tang, X.W. Wang, Q.Z. Xing, S.X. Zheng, Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education, Beijing 100084, China M.W. Wang, Northwest Institue of Nuclear Technology, Xian, China Abstract We present, in this paper, the present beam dynamics simulation results and experiments of the 3 MeV high current proton linac for the Compact Pulsed Hadron Source (CPHS) at Tsinghua University. The beam dynamics simulations of the recent status of the linac have been done, which helps the operation. Facility used for 2D beam profile measurement which is based on the CT algorithm with rotatable multi-wires, is under development. Some other experiments such as beam position measurement will also be introduced below. INTRODUCTION The Compact Pulsed Hadron Source (CPHS) project at Tsinghua University was launched in the year of 2009 [1], whose layout is shown in Figure 1. The final expected parameters of the CPHS linac are: beam energy to be 13 MeV, beam current to 50 ma, repetition rate to be 50 Hz and pulse length to be 500 μs. HEBT Target Station RFQ LEBT ECR Source Figure 2: CPHS linac facility and the target station. Figure 3 shows the operation status of the CPHS linac in 2014. The transmission rate of the RFQ is 70% recently, which is lower than the designed value of 97% and primary experimental value of 88% (with input peak current of 50mA at 50 µs /50 Hz). The reason may come from the unmatched beam from the LEBT, or the deformation of the RFQ cavity. Therefore, the linac will be inspected separately to solve the problem in the next stage. Figure 1: Layout of CPHS project. So far, CPHS has achieved its mid-term objective: delivering the 3 MeV proton beam to bombard the Beryllium target [2]. Figure 2 shows the status of CPHS linac facility at Tsinghua University recently, which contains one ECR Ion Source (IS), one Low Energy Beam Transport line (LEBT), one 4-vane Radio Frequency Quadrupole (RFQ) accelerator, and one High Energy Beam Transport line (HEBT) [3]. *Work supported by National Natural Science Foundation of China (Major Research Plan Grant No. 91126003 and 11175096) #807749514@qq.com Figure 3: Operation history of the 3 MeV linac in 2014. In this paper, the beam dynamics simulation results of the recent status of the CPHS linac are presented. Experiments such as beam profile measurement and beam position measurement are introduced. 355

BEAM DYNAMICS SIMULATION The beam dynamics simulation mainly focus on the Low Energy Beam Transport line and 4-vane Radio Frequency Quadrupole accelerator, which are the main part of the CPHS linac. The simulation of the LEBT is taken by Trace3D [4], TRACK [5] and TraceWin [6], and the field of the solenoid is calculated by Possion/ Superfish [7], as shown in Figure 4 [8]. The distribution at the end of the LEBT is imported directly to the RFQ entrance, then the beam dynamics simulation is accomplished by Toutatis/ TraceWin [9]. Figure 4: Solenoid and its field distribution in CPHS LEBT. The beam information calculated by TraceWin at the LEBT entrance, RFQ entrance and RFQ end is shown respectively in Figure 5~Figure 7. These results show a nice beam in the RFQ. Figure 8 presents the beam envelop in the structures. Figure 6: Beam information at the RFQ entrance. Figure 5: Beam information at the LEBT entrance. 356 Figure 7: Beam information at the RFQ end. Figure 8: Beam envelop in the LEBT and RFQ.

BEAM PROFILE MEASUREMENT 2D beam profile measurement is under development based on the Computed Tomography (CT) algorithm with rotatable multi-wires. Twenty carbon wires with the diameter of 30 µm are aligned and mounted on one stainless steel frame, as shown in Figure 9 and Figure 10. The current signal is obtained from the Secondary Electron Emission [10] and then amplified by a set of electronics system. Then Total Variation Algebraic Reconstruction Techniques (TV-ART) CT Algorithm is used to rebuild the image of the beam profile. Figure 11: 1D distribution measured by the wires. Figure 9: Rotatable multi-wires. Figure 12 shows the rebuilding result with data of five directions. Streak artifacts can be seen in the image. When the angular sampling increase to 17, the image become quite well, as shown in Figure 13. To avoid the thermal emission of the wire, the pulse width is decreased to 40 μs while the beam profile measurement. Figure 10: 2D beam profile measurement system. The primary experiment shows that wire current near the beam centre is 0.3 ma (while the estimated value is 0.4 ma). The beam is unstable day by day at the measurement position. Figure 11 shows one of the 1D distribution measured by the wires, in which the halo can be seen clearly. Figure 12: Rebuilding image of five directions. 357

Figure 15: The button-type BPM on the beam line. Figure 13: Rebuilding image of 17 directions. The following challenging work on the electronics system is to measure the current which is less than 1 na near the beam edge. BEAM POSITION MEASUREMENT The CPHS beam position measurement system is formed by several button-type BPMs and a hadron phase & position processor- Libera Single Pass H. The button-type BPM, which have one button in each of the four directions, is showed in Figure 14 and Figure 15. The output signals from the four ports of the BPMs are imported into Libera through a 20 db amplifier. IQ sample signals can be obtained by using the method of undersampling and digital orthorhombic demodulation. These signals are used to calculate the amplitude and phase. The value of the particle energy can be obtained from the phase information of two BPMs. Figure 16 and Figure 17 respectively show the transverse position signal and the longitudinal phase signal displayed in Libera, from which we can conclude that the beam center is 2 mm above the beam channel and 2 mm on the right of the beam channel. Figure 14: The button-type BPM in test. 358 Figure 16: The transverse position signal displayed in Libera.

Figure 17: The longitudinal phase signal displayed in Libera. At present, the measurement resolution of transverse position is 180 μm and the measurement resolution of phase is 0.6 degree. CONCLUSION The operation notes and beam dynamic results show that there are some problems to be solved. The experiments on the linac are proceeding quite well. The next stage of CPHS linac is the transformation of the lowenergy part including Ion source, LEBT and RFQ and the upgrade of the whole linac system. ACKNOWLEDGEMENT The authors would like to thank Nanuopa Co. Ltd. for the manufacture of rotatable multi-wires. REFERENCES [1] J. Wei et al., The Compact Pulsed Hadron Source Construction Status, IPAC 10, Kyoto, MOPEC071, p. 633 (2010); http://www.jacow.org [2] X.W. Wang, Delivery of 3-MeV Proton and Neutron Beams at CPHS: A Status Report on Accelerator and Neutron Activities at Tsinghua University, Physics Procedia, to be published. [3] Q.Z. Xing et al., Present Status of the 3MeV Proton Linac at Tsinghua University, LINAC 14, THPP137; http://www.jacow.org [4] K.R. Crandall, et al., TRACE 3-D Documentation, LAUR-97-886. [5] V.N. Aseev, et al., TRACK: The New Beam Dynamics Code, PAC 2005, Knoxville, May 2005, p. 2053 (2005), http://www.jacow.org [6] D. Uriot, N. Pichoff, TraceWin, Documentation, internal report CEA/DSM/DAPNIA/SEA/2000/45. [7] J. Billen, et al., Poisson/Superfish, LA-UR-96-1834. [8] Y. Yang, A low energy beam transport system for proton beam, Rev. Sci. Instrum. 84, 033306 (2013). [9] R. Duperrier, TOUTATIS, a radio frequency quadrupole code, Phys. Rev. Special Topics Acc. & Beams, december 2000. [10] E.J. Sternglass, The Physical Review, Second Series, Vol. 108, No. 1; OCTOBER 1, 1957. 359