Novel persistent phosphors of lanthanide-chromium co-doped. yttrium aluminum gallium garnet: design concept with vacuum

Similar documents
Investigation of Color Phosphors for Laser-Driven White Lighting. A thesis presented to. the faculty of. In partial fulfillment

OLED for Lighting. Outline

Calibration of Colour Analysers

High Efficiency White OLEDs for Lighting

Comparison of SONY ILX511B CCD and Hamamatsu S10420 BT-CCD for VIS Spectroscopy

Slides on color vision for ee299 lecture. Prof. M. R. Gupta January 2008

[source unknown] Cornell CS465 Fall 2004 Lecture Steve Marschner 1

Size Dependence of the Photo- and Cathodo-luminescence of Y 2 O 2 S:Eu Phosphors

OPTIMIZED LIGHT-EMITTING DIODE (LED) DEVICES THAT HAVE A HIGH COLOR RENDERING INDEX (CRI) FOR LIGHTING APPLICATIONS

DESIGN OF VISIBLE LIGHT COMMUNICATION SYSTEM

16-element Si photodiode arrays

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Light-Emitting Diodes

16-element Si photodiode arrays

Screen investigations for low energetic electron beams at PITZ

Light-Emitting Diodes

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Red (SrCa)AlSiN 3 : Eu 2+ Nitride Phosphor Particle Size of Phosphor Converted Warm White LEDs

Lecture Flat Panel Display Devices

Defense Technical Information Center Compilation Part Notice

DATASHEET. Intematix ChromaLit Contour. Remote Phosphor Light Source. Features & Benefits. ChromaLit Contour. Application & Uses. A19 Reference Design

16-element Si photodiode arrays

Report of Test LLIA

Activities on FEL Development and Application at Kyoto University

16-element Si photodiode arrays

Press Release May 17, SMM Develops New Oxide-based Red Phosphor In Collaboration with Tohoku University Research Team

Murdoch redux. Colorimetry as Linear Algebra. Math of additive mixing. Approaching color mathematically. RGB colors add as vectors

Development of OLED Lighting Panel with World-class Practical Performance

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses

OLEDWorks OLED Panel Brite Amber Marker Light

UniMCO 4.0: A Unique CAD Tool for LED, OLED, RCLED, VCSEL, & Optical Coatings

Selected Problems of Display and Projection Color Measurement

Solid State Lighting October 2010

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX60

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX27

OLED Technology Introduction

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL35-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL28-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV50-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV24-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV20-90**

High Performance White OLEDs Technologies for Lighting

Power saving in LCD panels

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE Basics 100 LED Tape Light - DI-24V-BLBSC1-63-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24V-BLBSC1-30-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-12-BLBSC2-50-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24-BLBSC2-30-W***

High Performance Surface Mount Chip LEDs. Technical Data. SunPower Series. Features. Description

Data Sheet. HSMx-C110/C170/C190/C191/C150 High Performance ChipLED

Luminescent mechanisms of ZnS:Cu:Cl and ZnS:Cu:Al phosphors

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-27-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-50-***

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Large photocathode 20-inch PMT testing methods for the JUNO experiment

Color measurement and calibration of professional display devices

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU DI-24V-ES30-BK 3000K BLACK.

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

Investigation of Radio Frequency Breakdown in Fusion Experiments

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Features. Applications. Part Number Color Package Description

An Introduction to TrueSource

REPORT DOCUMENTATION PAGE

Development of OLED Lighting Applications Using Phosphorescent Emission System

Transmissive XBPM developments at PSF/BESSY. Martin R. Fuchs

High intensity led illuminator ILED42A FEATURES: DESCRIPTION: ELECTRICAL CHARACTERISTICS:

Report of Test LLIA A-R01*

About LED Lighting. White Paper: Operating Characteristics. Low Power LEDs

Investigation of time-of-flight PET detectors with depth encoding

SURFACE MOUNT DISPLAY. Description. Features. Package Dimensions& Internal Circuit Diagram. Green. Part Number: ACSA02-41SGWA-F01. Super Bright Green

DISPLAY WEEK 2015 REVIEW AND METROLOGY ISSUE

From light to color: how design choices make the difference

Color-consistent LED modules for general lighting

11. Gas Discharge Displays

Performance and Radioactivity Measurements of the PMTs for the LUX and LZ Dark Matter Experiments

Introduction. An AFM/NSOM System with Fluorescence Lifetime Imaging. Application Note

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

Kingbright. L-7104YD-12V T-1 (3mm) Solid State Lamp DESCRIPTIONS PACKAGE DIMENSIONS FEATURES APPLICATIONS ATTENTION SELECTION GUIDE

1.10mm Height 1210 Package. Bi-Color (Multi-Color) Chip LED. Technical Data Sheet. Part No: S155VBC-V12B-B41B

Agilent HSMx-C110/C170/C190/C191/C150 High Performance ChipLED Data Sheet

Light Emitting Diodes

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LightLab I N T E R N A T I O N A L

Optical Electronics: RGB LED and the colours of the rainbow

Silicon PhotoMultiplier Kits

WP36BHD T-1 (3mm) Blinking LED Lamp

LightLab I N T E R N A T I O N A L

NVLAP LAB CODE:

NMOS linear image sensor

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

Measurement of Microdisplays at NPL

PLASMA DISPLAY PANEL (PDP) DAEWOO D I G I T A L DIGITAL TV DEVISION

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses. Unprecedented design freedom for solid state

Applications Keypad Backlighting Symbol Backlighting Status Indication Front Panel Indicator

Status of SOLARIS Arkadiusz Kisiel

Transcription:

Electronic Supplementary Material (ESI) for Journal of Materials Chemistry C. This journal is The Royal Society of Chemistry 2016 Supporting information Novel persistent phosphors of lanthanide-chromium co-doped yttrium aluminum gallium garnet: design concept with vacuum referred binding energy diagram Jian Xu, Jumpei Ueda, and Setsuhisa Tanabe * Graduate School of Human and Environmental Studies, Kyoto University, Kyoto 606-8501, Japan *Corresponding author. Tel: +81-75-753-6832. E-mail: tanabe.setsuhisa.4v@kyoto-u.ac.jp Fig. S1. X-ray diffraction (XRD) patterns of the YAGG:Cr and YAGG:Ln-Cr (Ln=Ce, Pr, Nd, Tb, Dy) persistent phosphors The phase compositions of YAGG:Cr and YAGG:Ln-Cr (Ln=Ce, Pr, Nd, Tb, Dy) transparent ceramic persistent phosphors were measured by X-ray diffraction (XRD) measurements (Ultima Ⅳ, Rigaku), utilizing nickel filtered CuK a radiation (1.5406 Å). All of the as-prepared samples are confirmed to be single phase matching well with the standard card (ICPDS: No. 089-6660) of Y 3 Al 2 Ga 3 O 12 (YAGG).

Fig. S2. The measurement setup of thermoluminescence (TL) two-dimensional (2D) plot measurements A 300 W Xe-lamp (MAX-302, Asahi Spectra) with a UV mirror module (250-400 nm) was used as the excitation source. The ceramic sample was set in a cryostat (Helitran LT3, Advanced Research Systems) to control temperatures and firstly illuminated by UV light at 150 K for 10 min, then heated up to 550 K at a rate of 10 K/min at 10 min after ceasing the illumination, and the thermoluminescence (TL) signals were recorded by a PMT detector (R11041, Hamamatsu Photonics & Co. Ltd.,) covered with 350 nm short-cut and 750 nm long-cut filters. The Si CCD spectrometer (QE65-Pro, Ocean Optics) was operated simultaneously with the TL measurement to always monitor the emission spectra at different temperatures.

Fig. S3. Persistent luminescent color coordinates of YAGG:Ce-Cr, YAGG:Pr-Cr and YAGG:Tb-Cr transparent ceramic persistent phosphors in CIE 1931 chromaticity diagram compared with that of the commercial SrAl 2 O 4 :Eu 2+ -Dy 3+ green persistent phosphor The color coordinates of persistent luminescence in CIE 1931 chromaticity diagram are (0.295, 0.553) for YAGG:Ce-Cr, (0.439, 0.367) for YAGG:Pr-Cr, and (0.313, 0.454) for YAGG:Tb-Cr ceramic phosphors compared with (0.283, 0.577) for the commercial SrAl 2 O 4 :Eu 2+ -Dy 3+ green persistent phosphor (LumiNova-GLL300FFS, Nemoto & Co. Ltd.,).

Fig. S4. (a) Luminous efficacy of human eyes in photopic vision and persistent luminescent spectra of (b) YAGG:Ce-Cr (c) YAGG:Pr-Cr (d) YAGG:Tb-Cr persistent phosphors at 5 min after ceasing UV (250-400 nm) illumination Photopic vision which is mediated by cone cells in human eyes allows color perception and shows a broad band sensitivity curve (from 380 to 780 nm) peaked at 555 nm with 683 lm/w luminous efficacy. The typical band emission due to Ce 3+ :5d 1 4f, line emissions due to Pr 3+ : 3 P J (J=0, 1, 2) 3 H 4,5, 1 D 2 3 H 4, and Tb 3+ : 5 D 4 7 F J (J=6, 5, 4, 3) in YAGG:Ce-Cr, YAGG:Pr-Cr, YAGG:Tb-Cr ceramic samples match well with the sensitivity curve of photopic vision.

Fig. S5. (a) Persistent luminescent decay curves recorded at 25 C after ceasing UV (250-400 nm) illumination for 5 min of YAGG:Pr (Ga=3.0) and YAGG:Pr-Cr (Ga=2.5, 3.0, 3.5, 4.0) transparent ceramic persistent phosphors (b) normalized thermoluminescence (TL) glow curves of crresponding samples Table S1. Luminance and duration of YAGG:Pr (Ga=3.0) and YAGG:Pr-Cr (Ga=2.5, 3.0, 3.5, 4.0) transparent ceramic persistent phosphors after ceasing UV (250-400 nm) illumination for 5 min Sample 5 min 20 min 60 min Duration upon composition (mcd/m 2 ) (mcd/m 2 ) (mcd/m 2 ) 0.32 mcd/m 2 (min) YAGG:Pr 3+ (Ga=3.0) 8.4 1.7 0.51 93±1 YAGG:Pr 3+ -Cr 3+ (Ga=2.5) 8.2 2.8 1.07 216±1 YAGG:Pr 3+ -Cr 3+ (Ga=3.0) 79.1 14.8 3.66 499±1 YAGG:Pr 3+ -Cr 3+ (Ga=3.5) 37.4 9.6 2.87 359±1 YAGG:Pr 3+ -Cr 3+ (Ga=4.0) 24.6 6.7 2.24 349±1 Compared with the Pr 3+ singly doped YAGG (YAGG:Pr) persistent phosphor with the same Ga 3+ content (Ga=3.0), the persistent luminescent intensity of the YAGG:Pr-Cr sample was enhanced by co-doping Cr 3+ which acts as an additional electron trap with ideal trap depth for Pr 3+ persistent luminescence working at room temperature. The peak temperature of the normalized TL glow curves for YAGG:Pr-Cr samples shifts to lower temperature with increasing Ga 3+ content (from 2.5 to 4.0). Since the TL peak temperature is correlated to the trap depth, the downshift of glow peak indicates that the trap depth becomes shallower. Because the bottom of conduction band of Ga 3+ -free garnet is composed by d orbitals of lanthanide ions while when Ga 3+ is added, 4s orbitals of Ga 3+ start to dominate the conduction band edge [1]. Therefore, the trap depth becomes shallower with increasing Ga 3+ content so that the persistent luminescent behaviors such as initial intensity and duration can be easily modified by changing Ga 3+ content in YAGG:Pr-Cr orange persistent phosphors. [1] M. Fasoli, A. Vedda, M. Nikl, C. Jiang, B. P. Uberuaga, D. A. Andersson, K. J. McClellan, and C. R. Stanek, Phys. Rev. B. 84, 081102 (2011).

Fig. S6. Photoluminescence (PL) spectrum (λex=460 nm) of the YAGG:Cr and diffuse reflectance of the YAGG:Nd ceramic samples Fo rster resonant energy transfer takes place when the oscillations of optical-induced electronic coherence on the donor are in resonance with the electronic energy gap of the acceptor. Briefly, this non-radiative energy transfer process requires sufficient spectral overlap between donor emission and acceptor absorption bands. Since the broad band emission of donor (Cr 3+ ) (including R-line and its phonon sidebands) matches well with the absorption band of acceptor (Nd 3+ ) in the same Y 3 Al 2 Ga 3 O 12 (YAGG) host, resonant energy transfer is possible from Cr 3+ to Nd 3+.