Interpolated DDS Technique in SDG2000X October 24, 2017 Preface

Similar documents
SSA3000X Series Spectrum Analyzer

SSA3000X Series Spectrum Analyzer

SDS1000CNL+ Series Digital Oscilloscope. DataSheet

Calibrate, Characterize and Emulate Systems Using RFXpress in AWG Series

SDS1000DL+/CML+ Series Digital Oscilloscope. DataSheet

Dithering in Analog-to-digital Conversion

ECE 5765 Modern Communication Fall 2005, UMD Experiment 10: PRBS Messages, Eye Patterns & Noise Simulation using PRBS

ECE438 - Laboratory 4: Sampling and Reconstruction of Continuous-Time Signals

Introduction to Data Conversion and Processing

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope

The high-end network analyzers from Rohde & Schwarz now include an option for pulse profile measurements plus, the new R&S ZVA 40 covers the

Datasheet SHF A

Clock Jitter Cancelation in Coherent Data Converter Testing

The effect of nonlinear amplification on the analog TV signals caused by the terrestrial digital TV broadcast signals. Keisuke MUTO*, Akira OGAWA**

Digitizing and Sampling

DIRECT DIGITAL SYNTHESIS AND SPUR REDUCTION USING METHOD OF DITHERING

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

Techniques for Extending Real-Time Oscilloscope Bandwidth

LabView Exercises: Part II

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note

Experiment 4: Eye Patterns

Analog Reconstruction Filter for HDTV Using the THS8133, THS8134, THS8135, THS8200

Realizing Waveform Characteristics up to a Digitizer s Full Bandwidth Increasing the effective sampling rate when measuring repetitive signals

Department of Communication Engineering Digital Communication Systems Lab CME 313-Lab

PCM ENCODING PREPARATION... 2 PCM the PCM ENCODER module... 4

Chapter 6: Real-Time Image Formation

R&S FPS-K18 Amplifier Measurements Specifications

Dac3 White Paper. These Dac3 goals where to be achieved through the application and use of optimum solutions for:

Synthesized Clock Generator

ZONE PLATE SIGNALS 525 Lines Standard M/NTSC

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

R&S FSV-K40 Phase Noise Measurement Application Specifications

Supplementary Course Notes: Continuous vs. Discrete (Analog vs. Digital) Representation of Information

ANSI/SCTE 40 Conformance Testing Using the R&S SFU, R&S SFE and R&S SFE100

Academia Sinica, Institute of Astronomy & Astrophysics Hilo Operations

10:15-11 am Digital signal processing

Mastering Phase Noise Measurements (Part 3)

Understanding Sampling rate vs Data rate. Decimation (DDC) and Interpolation (DUC) Concepts

Rec. ITU-R BT RECOMMENDATION ITU-R BT PARAMETER VALUES FOR THE HDTV STANDARDS FOR PRODUCTION AND INTERNATIONAL PROGRAMME EXCHANGE

Investigation of Digital Signal Processing of High-speed DACs Signals for Settling Time Testing

SDS1000X-E Series. Super Phosphor Oscilloscope. DataSheet

Rec. ITU-R BT RECOMMENDATION ITU-R BT * WIDE-SCREEN SIGNALLING FOR BROADCASTING

Module 8 : Numerical Relaying I : Fundamentals

Collection of Setups for Measurements with the R&S UPV and R&S UPP Audio Analyzers. Application Note. Products:

Dual Channel, 8x Oversampling DIGITAL FILTER

UNIVERSAL SPATIAL UP-SCALER WITH NONLINEAR EDGE ENHANCEMENT

DDC and DUC Filters in SDR platforms

SDS1000X-E Series. Super Phosphor Oscilloscope. DataSheet

Multirate Digital Signal Processing

Level Accuracy and Electronic Level Settings of SMIQ

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 105 MSPS ADC

How To Demonstrate Improved ACLR Dynamic Range With FSU and Noise Correction

Switched Mode Power Supply

How advances in digitizer technologies improve measurement accuracy

PS User Guide Series Seismic-Data Display

GHz Sampling Design Challenge

Development of an oscilloscope based TDP metric

By Tom Kopin CTS, ISF-C KRAMER WHITE PAPER

Getting Started with the LabVIEW Sound and Vibration Toolkit

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

Experiment 13 Sampling and reconstruction

What to look for when choosing an oscilloscope

RF Signal Capture & Playback Simple Operation Guide

CPE 400L Computer Communication Laboratory. Laboratory Exercise #9 Baseband Digital Communication

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 65 MSPS DUAL ADC

AWG5200 Series Arbitrary Waveform Generators Specifications and Performance Verification Technical Reference

Application Note Component Video Filtering Using the ML6420/ML6421

Mixer Conversion Loss

Debugging Digital Cameras: Detecting Redundant Pixels

Iterative Direct DPD White Paper

ni.com Digital Signal Processing for Every Application

NON-UNIFORM KERNEL SAMPLING IN AUDIO SIGNAL RESAMPLER

ADS1000C, CAL / CML Series

ENGINEERING COMMITTEE

Technical Data. HF Tuner WJ-9119 WATKINS-JOHNSON. Features

What's the SPO technology?

Research Results in Mixed Signal IC Design

An Introduction to the Sampling Theorem

System Quality Indicators

A review on the design and improvement techniques of comb filters

RF (Wireless) Fundamentals 1- Day Seminar

Dual Channel 3.0 GSPS Analog to Digital Input Module. RF Transformer. 2dB Fixed Attn. RF Transformer. 2dB Fixed Attn

RECOMMENDATION ITU-R BT (Questions ITU-R 25/11, ITU-R 60/11 and ITU-R 61/11)

Digital Audio: Some Myths and Realities

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

DELTA MODULATION AND DPCM CODING OF COLOR SIGNALS

Instrumentation Grade RF & Microwave Subsystems

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

Lab 5 Linear Predictive Coding

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Quadruple, 2:1, Mux Amplifiers for Standard-Definition and VGA Signals

Digital Signal. Continuous. Continuous. amplitude. amplitude. Discrete-time Signal. Analog Signal. Discrete. Continuous. time. time.

Lab P-6: Synthesis of Sinusoidal Signals A Music Illusion. A k cos.! k t C k / (1)

High Performance Real-Time Software Asynchronous Sample Rate Converter Kernel

Ultra-Wideband Scanning Receiver with Signal Activity Detection, Real-Time Recording, IF Playback & Data Analysis Capabilities

APPLICATIONS S240 Real-Time Spectrum Analysis application Numerous third-party analysis applications

Diamond Cut Productions / Application Notes AN-2

Politecnico di Torino HIGH SPEED AND HIGH PRECISION ANALOG TO DIGITAL CONVERTER. Professor : Del Corso Mahshid Hooshmand ID Student Number:

Meeting your needs R&S RTO2000 Digital Oscilloscope

Transcription:

Interpolated DDS Technique in SDG2000X October 24, 2017 Preface As can be seen in the data sheet for Siglent s SDG2000X arbitrary waveform generator series, the sampling rate specification (1.2 GSa/s) is followed by a note of 4X Interpolation. This may be confusing to some customers, even some experienced users of function generators. This white paper is intended to explain this specification and to discuss the advantages of the Interpolated DDS technique compared to a traditional DDS based function generator. Profile of Traditional DDS Systems The figure below shows the basic design of a traditional DDS system, in which digital waveform data is output in response to a reference clock for the DDS circuitry, then converted by the D/A converter using the same clock. That is to say, in a traditional DDS structure the clock for the DDS and for the D/A converter running at the same frequency. 2018 SIGLENT TECHNOLOGIES 1

Figure 1 Structure of Traditional DDS A reconstruction filter following the D/A converter helps to smooth the steps from the D/A s output in order to produce a smoother, more analog signal. Introduction to Interpolated DDS The figure below shows the structure of the Interpolated DDS. An interpolator is inserted between the DDS circuitry and D/A converter. In this structure, digital waveform data is output in response to the reference clock of the DDS circuitry, interpolated by I (in SDG2000X I = 4), and then converted by the D/A, with a sampling clock I times the frequency of the reference clock. After the D/A converter, a reconstruction filter is also applied. Figure 2 Structure of Interpolated DDS Siglent s SDG2000X applies this technique with the interpolation factor I = 4. The reference clock of the DDS circuitry on the SDG2000X is 300 MHz. Using the interpolation circuitry, the sampling clock of the D/A converter is increased to 1.2 GHz. This is the explanation behind 1.2 GSa/s specification found in the data sheet 1.2 GSa/s followed by a 4X interpolation note. This explains the mechanics behind the interpolated sampling technique. However, what is the technical reasoning behind Siglent s innovative sampling technique? Why Interpolation? 2018 SIGLENT TECHNOLOGIES 2

4.1 To Break the Bandwidth Limit First, let s compare the waveform in the time domain using the two different sample rates. Looking at the output waveform of the D/A, the 1.2 GSa/s sample rate results in smaller steps (higher resolution) than with the 300 MSa/s sampling clock (Fig 3). The reader may ask, If both waveforms are to be passed through a restructuring filter in order to smooth the waveform steps, then the sample rate should not matter. The fact is, the step size does affect the final smoothed waveform. Now let s look at this difference in the frequency domain in order to get a clearer understanding. The figure below shows a spectrum example in which an 80 MHz sine wave is output by a D/A with 300 MSa/s. Output spectrum of the D/A includes the fundamental, and its image frequencies N fs ± fout, N=1,2. Amplitudes of all the spectrum components comply with the sin(x)/x envelope. Usage of the reconstruction filter is to filter all of the image frequencies which are located outside the Nyquist bandwidth. 2018 SIGLENT TECHNOLOGIES 3

Figure 4 Spectrum of 300 Msa/s D/A, 80 MHz Output An ideal reconstruction filter should retain all the signals located in the Nyquist bandwidth, and filter out the ones outside it. In other words, its frequency response should be coincident with the Nyquist bandwidth, as the shadow part in Figure 4. In this case, the maximum frequency can reach the Nyquist Limit (e.g. 1/2 sampling clock frequency). As we know, in engineering the ideal filter with brick wall response doesn t exist. In the real world, filters actually have some degree of roll off. Figure 4 shows the spectrum of the output from a 300 MSa/s A/D converter with an output frequency of 80 MHz. The nearest image occurs at 220 MHz so the maximum roll-off would occur at 140 MHz. But for a 150 MHz signal, the nearest image is 300 150 = 150 MHz, the space remaining for roll-off is zero, which is not realizable. Generally, the limit bandwidth of a reconstruction filter is 40% of the sampling clock. That is to say, for a 300 MSa/s D/A, the maximum available output frequency is 120 MHz. The figure below shows 2 reconstruction filter designs with roll offs from 120 MHz to 180 MHz. Both designs are 9-order elliptic filters. The difference is the design on the left uses ideal components, and the one on the right uses real-world components, with parasitic parameters. As we can see, a real filter has an extra ~3dB attenuation on the corner frequency (i.e. 120 MHz), and its attenuation performance on the stop band cutoff frequency (i.e. 180 MHz) degrades. 2018 SIGLENT TECHNOLOGIES 4

Figure 5 Reconstruction Filter Design with Ideal Components V.S. with Real Components In addition, the sin(x)/x envelope of the D/A s response itself will add attenuation to the signal. At 40% of the sampling clock (e.g. 120 MHz in Figure 4), the attenuation caused by the D/A is about 2.4 db. An 2018 SIGLENT TECHNOLOGIES 5

inverse sin(x)/x filter is generally necessary to compensate this attenuation. If the sampling rate of D/A is 1.2 GSa/s, for a 80 MHz signal, the nearest image is 1.12 GHz, so the maximum roll off of reconstruction filter could be 1.04 GHz, as shown in Figure 6. Design of the reconstruction filter is greatly simplified. Figure 6 Spectrum of 1.2 GSa/s D/A, 80 MHz Output Figure 7 shows the real reconstruction filter design with roll off from 120 MHz to 1.08 GHz. This is much easier to achieve than the one with roll off from 120 MHz to 180 MHz. 2018 SIGLENT TECHNOLOGIES 6

On the other hand, as the main lobe width of the sin(x)/x envelope increases, the attenuation contributed by the D/A decreases. At 120 MHz, the attenuation caused by the 1.2 GSa/s D/A is approximately 0.14 db, which can be ignored in most cases. No more inverse sin(x)/x filtering is needed. Based on the above, because of limits of the reconstruction filter a 300 MSa/s D/A can only output a 120 MHz maximum frequency. But a 1.2 GSa/s D/A can achieve a higher upper frequency limit. Of course in the interpolated DDS structure, the digital filter in the interpolator will restrict the frequency to the Nyquist limit of the DDS clock (e.g. 150 MHz), but a digital filter is much easier to design than an analog reconstruction filter. Using the interpolated DDS, it is easy to raise the upper limit of output frequency from 120 MHz to 130 MHz or more. 4.2 To Remove the Spurs Generated by D/A Converter Intermodulation distortion is unavoidable in a D/A converter. In a traditional DDS structure, it is difficult to remove some inter-modulation distortion components between the clock and the output signal, such as fs 2018 SIGLENT TECHNOLOGIES 7

-2fout, fs -3fout. The figure below shows an example with 120 MHz output frequency and 300 MSa/s sampling rate. The distortion = fs -2fout = 60 MHz falls into the passband of the reconstruction filter. It is not possible to be removed. But with a 4X interpolated DDS structure, for 120 MHz frequency output, the distortion components = fs -2fout = 960 MHz, fs -3fout = 840 MHz, which are located far away from passband of the reconstruction filter. Summary Compared with a traditional DDS design, the Interpolated DDS technique inserts an interpolator between the DDS circuitry and the D/A converter, yielding a higher sampling rate. With such a structure the design of the reconstruction filter is no longer the bottleneck for bandwidth. On the other hand, the problems due to intermodulation distortion products falling into the passband of the reconstruction filter is solved, resulting in better SFDR performance. Reference [1] Analog Devices, A Technical Tutorial on Digital Signal Synthesis [2] A.V. Oppenheim, R.W. Schafer, J.R. Buck, Discrete-time Signal Processing 2018 SIGLENT TECHNOLOGIES 8

North American Headquarters SIGLENT Technologies America, Inc 6557 Cochran Rd Solon, Ohio 44139 Tel: 440-398-5800 Toll Free:877-515-5551 Fax: 440-399-1211 info@siglent.com www.siglentamerica.com/ European Sales Offices SIGLENT TECHNOLOGIES EUROPE GmbH Liebigstrasse 2-20, Gebaeude 14, 22113 Hamburg Germany Tel: +49(0)40-819-95946 Fax: +49(0)40-819-95947 info-eu@siglent.com www.siglenteu.com Asian Headquarters SIGLENT TECHNOLOGIES CO., LTD. Blog No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao an District, Shenzhen, 518101, China. Tel:+ 86 755 3661 5186 Fax:+ 86 755 3359 1582 sales@siglent.com www.siglent.com/ens 2018 SIGLENT TECHNOLOGIES 9