Fieldbus Components Section K

Similar documents
MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Inductive sensor NI3-EG08K-Y1-H1341

Capacitance Level Measurement Electronic insert FEC 12

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

PROFIBUS Installation suggestion

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

8 Installation Equipment

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Connectors, self-assembly

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

HygroClip Introduction

Control cabinet interface and cable entry systems

Inductive sensor BI1.5-EG08K-Y1

TFR5 Room or outdoor temperature sensor. CombiTemp TM

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

User manual Version Ex Remote station XGA 15" family type 17-71KB-45../... Ex Remote station SXGA 18" family type 17-71KB-55../...

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Inductive sensor NI10-M18-Y1X-H1141

Fibre Optic Modem ODW-611

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Leading Provider of Cable Management Solutions. M8 & M12 Cordsets & Accessories

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

TFRN Industrial RTD temperature sensor. CombiTemp TM

Process transmitter RMA422

Rack mounted telephone- and leased line modem for industrial applications

Inductive sensor With analog output BI15-M30-LI-EXI

LD OEM/LD PDS/LD PeCo

ODW-621. RS-232 Point-to-point applications

7 Lighting Technology

Fibre optic router for TP/FT-10 LRW-112PP

Connectors, self-assembly

Siemens Industry Online Support

INSTALLATION GUIDE FIRST STEPS MOUNTING OF THE SENSOR HANDLING THE WIRE ROPE

EAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE MULTITURN ABSOLUTE ENCODERS EAM PROFIBUS

VIPA Accessories. ProfiHub B BE00 Manual

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

TFRN Industrial RTD temperature sensor. CombiTemp TM

Process Transmitter RMA 422

Operating Instructions

ERbic Bus Interface Connector System. Catalog E /06 Edition 4

10 PDUs 19 PDUs Zero-U PDUs

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Siemens Industry Online Support

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

LONWORKS Fibre Optic Router

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

VERWER TRAINING AND CONSULTANCY LTD Supporting the PROFIBUS Group UK & PROFIBUS International

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Signal conditioning instruments

Absolute encoders multiturn

EA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE SINGLETURN ABSOLUTE ENCODERS EA PROFIBUS

Fibre Optic Modem ODW-622

DMP 331i / DMP 333i LMP 331 i

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Cable guide. for. High Performance Controllers and TeleControllers. Cable types and wiring guidelines

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

MODEL HS35 DRAWWORKS OPTICAL ENCODER

Basic, cost-effective motor control in one unit: MOVITRAC 07.

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.


Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Advantys STB Standard Profibus DP Network Interface Module Applications Guide. 890USE17300 Version 2.0

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

TYPE APPROVAL CERTIFICATE

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Absolute Encoders Multiturn

Operating instructions

Quality products from a single source

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Capacitance Limit Detection nivotester FTC 420/421/422

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Sensor Actuator Interface Passive

Product group 1. Product description. At a glance. Cable entry systems for entering pre-terminated cables

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

CEDES. Functional description CEDES 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN)

Nessie Coils for VDH and VDHT valves

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

Selection matrix for electronic pressure switches

Transcription:

ection K This section covers our full range of connection technology for Profibus DP and Profibus P available in cabinet or field mount formats and for harzardous locations. We also supply a complete range of connecttors and adaptors and through panel bushes to help you make the most reliable connections to your system. There are many more variations available, please contact your local reseller for details. www.weidmüller.com.au

Introduction to Profibus DP, Profibus P and Foundation Fieldbus asics There are two variations of PROFIU in use today; the most commonly used PROFIU DP, and the application specific, PROFIU P: PROFIU DP (Decentralised Peripherals) is used to operate sensors and actuators via a centralized controller in production (factory) automation applications. PROFIU P (Process utomation) is used to monitor measuring equipment via a process control system in process automation applications. This variant is designed for use in explosion/hazardous areas (Ex-zone 0 and 1). The Physical Layer conforms to IEC 61158-2, which allows power to be delivered over the bus to field instruments, while limiting current flows so that explosive conditions are not created, even if a malfunction occurs. The number of devices attached to a P segment is limited by this feature. P has a data transmission rate of 31.25 kbit/s. However, P uses the same protocol as DP, and can be linked to a DP network using a coupler device. The much faster DP acts as a backbone network for transmitting process signals to the controller. This means that DP and P can work tightly together, especially in hybrid applications where process and factory automation networks operate side by side. Profibus P and Fieldbus foundation use the same physical layer with different connector types on the stub connection. FCon fieldbus distributors FCon fieldbus distributors are available in industrial and EEx (ia) versions. They are used for coupling 1 8 field devices or sensors onto the backbone via stub cables. The stub cables are connected by an M12 (Profibus) or 7/8 (Foundation Fieldbus) plug-in connector or by wiring directly to internal tension clamp connectors via an EMC cable gland. The communication and device power is handled by a common 2-core wire. Colour coding The standard distributors are finished in grey paint, the Ex-approved distributors are blue. Fieldbus Foundation distributors are black. us Termination PROFIU-P distributors are generally equipped with a switch-in terminating resistor. In potentially explosive areas, the terminating resistor is manufactured with a separate box and must be used instead of the right-hand cable gland. In the case of PROFIU-DP, an additional external 24Vdc power supply is required. This makes the terminator independent of the last station in the network. J.2

Field mount Profibus-DP Distributors Distributor Terminator/ Power Injector PROFIU DP distributor The PROFIU topology is a line structure. The branches (T-pieces) connect the individual field devices or remote I/Os to the bus cable. The length of the branch cable depends on the transmission rate and should be as short as possible. The total of all branch lengths for transmission rates up to 1.5 Maud may not exceed max. 6.6 m. The trunk cable passes through an EMC cable gland into an aluminium enclosure where it is connected to a tension clamp terminal. The enclosure has a pressure compensation element to counteract the effects of climatic cycles. Cable Gland Via M16 Cable Gland Cable Gland Clamping Range 5.5 9.5mm² ocket Conections Coded 5-pin M12 ocket Coding -coded Contact surface M12 plug/socket CuZnu Power supply us Connection 24Vdc ±10% aud Rate 1.5Mbs -25 C to +55 C Material High grade aluminium alloy (l-i 12) Finish Painted RL 7001 IP66 PROFIU DP distributors offer the following features: Tension clamp connection technology EMC cable gland M12 plug-in connectors External earth stud Pressure-equalising element IP66 Ingress Protection Class tainless steel versions FCon DP CG 1-Way FCon DP M12 1-Way FCon DP CG Term 24V FCon DP M12 Term 24V M12 ocket -coded 1 RxDx / TxD-N / -wire (red) 4 2 RxDx / TxD-N / -wire (green) - hield 5 hield 3 Description tub Cable Connection l Cable Gland M12 ocket 1 way Distributor box 8564340000 8564350000 8714260000 8714270000 ctive us Terminator (with 24Vdc Power Connection) 8564290000 8564330000 8714240000 8714250000 J.3

Profibus-DP IP20 T-Piece PROFIU DP IP20 T-Piece This interface unit for PROFIU-DP provides users with a convenient connection in the control cabinet. The modules can be mounted on T 32/35 terminal rails and provide connections for standardised PROFIU-DP cables. pur cables can also be connected. Please note that spur cables should be kept short as possible. Part No. 8788580000 has a 9-pin sub-d socket for connecting analysis/ programming devices. Features X2 X4 X5 X6 Cable clamp Cable clamp X8 X7 L1 L3 L2 L4 unused X1 X3 X9/3 X9/8 X9/10 X9/11 X9/1 X9/5 X9/7 X9/9 X9/2 X9/4 X9/6 T-piece functions Good shield contact mple space for connecting the bus cable T 32/35 terminal rail mounting tandardised sub-d connection for PROFIU-DP Tension clamp connection technology Optional U D Via M16 Cable Gland (optional 9-way ub-d type) Cable Gland Clamping Range 4.5 8.0mm² aud Rate 1.5M 0 C to +55 C T35/T32 DIN Rail mount IP20 R P-DP T R P-DP T U-D Ordering Data Description Order No. R P-DP T DIN Rail Mount Profibus DP T-Piece 8800040000 R P-DP T U-D DIN Rail Mount Profibus DP T-Piece with ub-d Connector 8788580000 J.4

tandard, Field mount, Profibus-P Distributors tandard PROFIU P distributors The PROFIU-P T-connectors are intended for direct coupling of measuring devices, sensors, actuators, etc. tandard Profibus P distributors are 1, 2, 4 or 8 Way T-connectors available in three formats: asic, which incorporate a jumper selectable termination resistor OVP, which have inbuilt surge protection Current Limiting, which have switch selectable 20/40/60m current limiting on each stub connection. This protects the bus from devices which are short circuit or draw too much power from the bus. Features IP 66 Interruption-free bus operation for service situations External earth stud Pressure equalising element EMC cable gland Cable Gland Cable Gland Clamping Range ocket Conections Coding Contact surface Power supply Via M16 Cable Gland 5.5 9.5mm² Coded M12 ocket -coded female M12 plug/socket CuZnu us Connection 24Vdc ±10% Transmission Rate 31.25 kbit/s -25 C to +55 C Material High grade aluminium alloy (l-i 12) Finish Painted RL 7001 IP66 Wire jumper us connection 1 2 3 R2 1 2 R4 1 R3 2 3 R5 V3 x 7 R1 C1 1 2 3 20/40/60 m 20/40/60 m DIP switches 1 2 20 m P- (3) hield (4) P+ (1) n.c. (2) n.c. 40 m 60 m Product Description asic Over Voltage Protecting (OVP) 20/40/60m Current Limiting lum -teel Cable Gland M12 ocket Cable Gland M12 ocket Cable Gland M12 ocket Profibus P 1-way 8564090000 8564060000 8714120000 8714080000 8714200000 8714160000 8703430000 8726020000 8715270000-8726110000 - Profibus P 2-way 8564100000 8564070000 8714130000 8714090000 8714210000 8714170000 - - - - - - Profibus P 4-way 8564110000 8564080000 8714140000 8714100000 8714220000 8714180000 8703450000 8726040000 8726080000-8715260000 - Profibus P 8-way 8564300000 8564310000 8714150000 8714110000 8714230000 8714190000 8703470000 8726050000 8726090000-8726160000 - J.5

Profibus-P TEX EEx (ia) PROFIU P distributors for hazardous areas The PROFIU-P T-connectors are intended for direct coupling of measuring devices, sensors, actuators, etc in hazardous areas. Profibus P distributors are 1, 2, 4 or 8 Way T-connectors with a separate plug in bus terminator. Features TEX approved intrinsic safety for use in hazardous areas IP 66 Interruption-free bus operation for service situations External earth stud Pressure equalising element EMC cable gland Cable Gland Via M16 Cable Gland Cable Gland Clamping Range 5.5 9.5mm² ocket Conections Coded M12 ocket Coding -coded Contact surface M12 plug/socket CuZnu Power supply us Connection 24Vdc ±10% Transmission Rate 31.25 kbit/s -25 C to +55 C Material High grade aluminium alloy (l-i 12) Finish Painted RL 7001 IP66 Cable brown Wire jumper P- (3) hield (4) P+ (1) n.c. (2) n.c. Cable white Ordering Data Product tub Cable Connection Cable Gland M12 ocket FCon EEx ia T-connector 1-Way 8564180000 8564150000 FCon EEx ia T-connector 2-Way 8564190000 8564160000 FCon EEx ia T-connector 4-Way 8564200000 8564170000 FCon EEx ia T-connector 8-Way 8564240000 8564250000 FCon EEx ia Terminator with Earth Connection 8606180000 FCon EEx ia Terminator no Earth Connection 8556460000 J.6

Profibus P ccessories Profibus P ccessories Weidmüller provdies a complete selection of cables, connectors and through panel bushes to help you make the most reliable connections to your system. There are many more options available, contact your local resller for details. Ordering Data Description Order No. FCon M12 4P M EMC M12 tandard Plug, 4-Pole, PG 9, Metal hielded, -Coded, crew Connection 9455640000 FCon M12 4P FM EMC M12 tandard ocket, 4-Pole, PG 9, Metal hielded, -Coded, crew Connection 8426220000 IW-M-4/8 M12 M12 Right-ngle Plug, 4-Pole, PG 9, Metal hielded, -Coded, crew Connection 1803930000 IW-FM-4/8 M12 M12 Right-ngle ocket, 4-Pole, PG 9, Metal hielded, -Coded, crew Connection 1803910000 FC P M12 M 1M 1m long cable with M12 Male Plug on one end only 1785120100 FC P M12 M 2M 2m long cable with M12 Male Plug on one end only 17851200200 FC P M12 M 5M 5m long cable with M12 Male Plug on one end only 1785120500 FC P M12 M 10M 10m long cable with M12 Male Plug on one end only 1785121000 FC P M12 FM 1M 1m long cable with M12 Female Plug on one end only 1785110100 FC P M12 FM 2M 2m long cable with M12 Female Plug on one end only 1785110200 FC P M12 FM 5M 5m long cable with M12 Female Plug on one end only 1785110500 FC P M12 FM 10M 10m long cable with M12 Female Plug on one end only 1785111000 FC P M12 M-FM 1M 1m long connecting cable (M12 Female Plug to M12 Male plug) 1785100100 FC P M12 M-FM 2M 2m long connecting cable (M12 Female Plug to M12 Male plug) 1785100200 FC P M12 M-FM 5M 5m long connecting cable (M12 Female Plug to M12 Male plug) 1785100500 FC P M12 M-FM 10M 10m long connecting cable (M12 Female Plug to M12 Male plug) 1785101000 I-WDF-5P M12 60mm M12 Thru panel bushing 1819450000 IE-M12-4-0.5U-EH-V crew-in M12 Plug connector PG9 thread (500mm leads) 1861220001 IE-EW-M20/PG9-W24-V daptor PG9 internal to M20 external Thread 1950270000 PO-4P M12 PG13.5 150mm crew-in M12 Plug connector PG13.5 (150mm leads) 9455650000 PO-4P M12 PG13.5 300mm crew-in M12 Plug connector PG13.5 (300mm leads) 8425910000 PO-4P M12 M20 150mm crew-in M12 Plug connector PG20 (150mm leads) 8425930000 PO-4P M12 M20 300mm crew-in M12 Plug connector PG20 (300mm leads) 8425940000 J.7