Indoor Dual Converter

Similar documents
1/3 RACK-MOUNTED BLOCK CONVERTERS

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

SYNTHESIZED COMMUNICATION CONVERTERS

MULTIBAND 1/3 RACK-MOUNTED

Multiple Band Outdoor Block Up- and Downconverters

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

High-Value 100 Series (Outdoor)

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

High Performance Outdoor Test Translators

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

Modular Block Converter Systems

Redundant LNB Systems

SCR Series Synthesized Converters L, C, X, Ku, and DBS Bands

Redundant LNB Systems

Satellite Up- and Downconverter Indoor / Outdoor

Satellite Up- and Downconverter

L-Band Block Up- and Downconverter Indoor / Outdoor

Synthesized Block Up- and Downconverter Indoor / Outdoor

Synthesized Block Up- and Downconverter

Redundant LNB Systems

Inmarsat Downconverter Narrowband Downconverter

Satellite Up- and Downconverter

L-Band Block Upconverter

X-Band Redundant LNB Systems

16W Ku-band Matchbox BUC

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

DA : Series of Narrowband or Wideband Distribution Amplifiers

L-BAND FREQUENCY CONVERTER

DA E: Series of Narrowband or Wideband Distribution Amplifiers

Product Catalogue January 2018

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Ku-Band Redundant LNB Systems

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

OBSOLETE HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

Analog & Digital RF-Solutions

C-Band Redundant LNB Systems

Instruction Manual Model # Block Upconverter

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

ThinkRF D GHz RF Downconverter

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

HMC7053. Block Upconverters. Typical Applications. General Description. Features. Functional Block Diagram. Satellite communications.

SIR MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz. WIDE FREQUENCY RANGE: GHz

R-1580A Microwave Downconverter. Product Brochure

Instruction Manual Model UHF, L-Band, Up/Downconverter

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

Instruction Manual Model BlockUpconverter

Typical applications:

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

Instruction Manual Model Block Up/Downconverter

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

Instruction Manual Model Block Downconverter

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

ACION 8000 Series. A8KFR1 1RU Forward Receiver

Instruction Manual Model Block Upconverter

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

QRF5000 MDU ENCODER. Data Sheet

Model P/03P Upconverters

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SATCOM FIBER OPTIC PRODUCTS

Orbital Ka-ISO. Ext Ref Ka LNB with integrated isolator. Orbital Research Ltd Marine Drive, White Rock, BC. Canada V4B 1A9

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DQT1000 MODEL DIGITAL TO QAM TRANSCODER WITH DIGITAL PROCESSING AND MULTIPLEXING

Instruction Manual Model Up/Downconverter

GEOSYNC. CAPABILITIES and PRODUCTS CATALOG. Outdoor Mounted. Rack Mounted. Converter Module. Block Converters, L-Band to Transponder Frequency

Technical Data. HF Tuner WJ-9119 WATKINS-JOHNSON. Features

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Instruction Manual Model Downconverter

THE ART OF ENGINEERING

MODEL Band Channels Up/Down IF In/Out RF In/Out Step Size Remote M&C Price

L-BAND MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Wideband LNB: 2.4 GHz

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

FMMX9000 DATA SHEET. Field Replaceable SMA IQ Mixer From 4 GHz to 8.5 GHz With an IF Range From DC to 3.5 GHz And LO Power of +15 dbm.

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

R3267/3273 Spectrum Analyzers

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

DM240XR Digital Video Broadcast Modulator With AutoEQ. Satellite Modems

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

FMMX9004 DATA SHEET. Field Replaceable SMA IQ Mixer From 15 GHz to 23 GHz With an IF Range From DC to 3.5 GHz And LO Power of +17 dbm.

FMMX9002 DATA SHEET. Field Replaceable SMA IQ Mixer From 8.5 GHz to 13.5 GHz With an IF Range From DC to 2 GHz And LO Power of +19 dbm.

R-1550A Tempest Wide Range Receiver

TELEDYNE Paradise Datacom A Teledyne Technologies Company

Technical Description

Ku-band 2W (3W typ.) Transmitter Model No. NJT5037 Type 1 (N-type Female Input Connector) Model No. NJT5037F Type 2 (F-type Female Input Connector)

L-Band Block Upconverter MKT-74 Rev B JULY 2017 Page 1 of 7

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Transcription:

Indoor (1RU) Dual Block Up Converter Description Paradise Datacom s Dual is a selfcontained (1RU) indoor chassis, which can be configured as a single thread system or as a 1:1 Redundant System. Built upon Paradise Datacom s popular and reliable zbucs, the Indoor Dual BUC is an excellent, full featured system. The Up Converter translates an L-Band frequency input signal between 950 to 2050 (Dependant upon RF Band Selected) to a C-, X- or output frequency. The Down Converter translates a C-, X- or input frequency to an L-Band frequency output signal between 950 to 2050 (Dependant upon RF Band Selected) System control is available through the rear panel parallel I/O remote, or serial I/O remote connectors, and may be accessed using the Paradise Datacom Universal Monitor and Control software. FEATURES Supports all Satellite Frequency Bands 1:1 Redundancy Single 1RU chassis Low phase noise High Stability Oscillator Remote Monitoring Summary alarm OPTIONS Dual Upconverter Dual Downconverter Up/Downconverter SPECIFICATIONS Conversion Gain 25 db Output power (P1db) 15dBm Spurious -65 dbc Phase Noise Exceeds IESS Standards Paradise Datacom LLC Paradise Datacom Ltd. 328 Innovation Blvd. 1 Wheaton Road, Witham State College, PA 16803 USA www.paradisedata.com Essex CM8 3UJ England Tel: 1 (814) 238-3450 Tel: +44(0) 1376 515636 Fax: 1 (814) 238-3829 Fax: +44(0) 1376 533764 1 OF 6

PARAMETER Upconverter Specifications LIMITS Input Frequency Range Output Frequency Range UNITS 950 to 1525 950 to 1750 950 to 1350 950 to 2050 950 to 2050 5850 to 6425 5850 to 6650 6700 to 7100 7900 to 8400 12750 to 13250 13750 to 14500 14000 to 14500 17300 to 18400 Input Return Loss 15 db (min.) Output Return Loss 18 db (min.) Gain 25 db Attenuation Range n/a Nominal Input Level -25 dbm Image Rejection 60 db Carrier Mute 60 db Output Power (P1dB) 15 dbm Amplitude Response (36/40 ) ± 0.5 db Amplitude Response (Band) ± 1 db Gain Stability/24 hours ± 0.25 db 3rd Order Intercept 18 dbm Signal Related spurious -65 dbc Signal Independant -75 dbm Spectrum Sense: Non-Inverted Internal REF YES External Ref Detect YES Frequency Stability (temperature) ± 2x10-8 Frequency Stability (aging) ± 5x10-9 Per day Input Impedance 50 ohms Input Connector: N (f) Output Impedance 50 ohms Output Connector SMA (f) External Reference (10 ) [Optional 5 ] 0 ± 3 dbm Reference Monitor/Adjust Capability No Phase Noise Performance Exceeds IESS Noise Figure (maximum gain) 15 Summary Alarm Connectors L-Band RF Reference Comm/Fault Ethernet N (f) SMA BNC 2 DE-9P RJ45 2 OF 6

Downconverter Specifications Output Frequency Range 950 to 1750 950 to 1950 950 to 1700 950 to 1950 950 to 1750 950 to 1500 Input Frequency Range 3400 to 4200 7250 to 7750 10700 to 11700 10950 to 11700 11200 to 12200 11700 to 12500 12200 to 12750 Input Return Loss 20 db (min.) Output Return Loss 15 db (min.) Gain 35 db (min.) Attenuation Range n/a RF Input Power -25 dbm (max.) Output Power (P1dB) 15 dbm Amplitude Response (40 ) ± 0.5 db Amplitude Response (Band) ± 1 db Gain Stability/24 hours ± 0.25 db 3rd Order Intercept -60 dbc Carrier Spurious -60 dbc Spectrum Sense: Inverted Frequency Stability (temperature) ± 2x10-8 Frequency Stability (aging) ± 5x10-9 Per day Input Impedance 50 ohms Input Connector SMA (f) Output Impedance 50 ohms Output Connector N-Female External Reference (10 )(5 Optional) 0 ± 3 dbm Reference Monitor/Adjust Capability NO Phase Noise Performance Exceeds IESS Noise Figure (max. gain) 15 LO Leakage -80 dbm Image Rejection -60 db (min.) 3 OF 6

Electronic Specifications Primary Power Requirements 90-265 VAC Frequency 47-63 Hz Power Consumption (typical) 30 W Physical Specifications Weight 15 lbs (kg) Overall dimensions (W x H x D) 19 x 1.75 x 20 482.6 x 44.5 x 508 Environmental Specifications Operating Temperature Relative Humidity (at 30 C) Atmospheric pressure Non-operating Temperature Relative Humidity (at 45 C) Atmospheric pressure Shock and vibration 0 to 50 95% non-condensing 10,000-50 to 70 95% non-condensing 40,000 Normal handling by commercial carriers in. mm C ft. C ft. 4 OF 6

Part Number Configuration - Dual Upconverter R B C 1 X X X X X X Configuration 1 - Dual Upconverter 2 - Dual Downconverter 3 - Up/Downconverter Upconverter 1 Output Frequency () A - 5850 to 6425 B - 5850 to 6650 C - 6700 to 7100 D - 7900 to 8400 E - 12750 to 13250 F - 13750 to 14500 G - 14000 to 14500 H - 17300 to 18400 Upconverter 1 Input Frequency () A - 950 to 1525 B - 950 to 1750 C - 950 to 1350 D - E - 950 to 1700 F - 950 to 2050 External Reference A - 5 B - 10 Upconverter 2 Output Frequency () A - 5850 to 6425 B - 5850 to 6650 C - 6700 to 7100 D - 7900 to 8400 E - 12750 to 13250 F - 13750 to 14500 G - 14000 to 14500 H - 17300 to 18400 Upconverter 2 Input Frequency () A - 950 to 1525 B - 950 to 1750 C - 950 to 1350 D - E - 950 to 1700 F - 950 to 2050 Part Number Configuration - Dual Downconverter R B C 2 X X X X X X X X Configuration 1 - Dual Upconverter 2 - Dual Downconverter 3 - Up/Downconverter External Reference V - 5 X - 10 Downconverter 1 Input Frequency () A - 3400 to 4200 B - 7250 to 7750 C - 10700 to 11700 D - 10950 to 11700 E - 11200 to 12200 F - 11700 to 12500 G - 12200 to 12750 Downconverter 2 Input Frequency () A - 3400 to 4200 B - 7250 to 7750 C - 10700 to 11700 D - 10950 to 11700 E - 11200 to 12200 F - 11700 to 12500 G - 12200 to 12750 5 OF 6

Part Number Configuration - Up/Downconverter R B C 3 X X X X X X X X Configuration 1 - Dual Upconverter 2 - Dual Downconverter 3 - Up/Downconverter Upconverter Output Frequency () A - 5850 to 6425 B - 5850 to 6650 C - 6700 to 7100 D - 7900 to 8400 E - 12750 to 13250 F - 13750 to 14500 G - 14000 to 14500 H - 17300 to 18400 External Reference A - 5 B - 10 Downconverter Input Frequency () A - 3400 to 4200 B - 7250 to 7750 C - 10700 to 11700 D - 10950 to 11700 E - 11200 to 12200 F - 11700 to 12500 G - 12200 to 12750 Specifications listed in this datasheet are subject to change without notice. 6 OF 6