SAM. Satellite Meter. User Manual. Ver: 0814us

Similar documents
TAM Terrestrial Meter

Digital Terrestrial Alignment & Installation Meter

HD-CM HORIZON DIGITAL CABLE METER

Owner s Manual. Sat-Meter MSK 15. Order No.:

HD-TM PLUS HORIZON DIGITAL TERRESTRIAL METER

SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE

RS232 Connection. Graphic LCD Screen. Power Button. Charger Adapter Input LNB Output. MagicFINDER Digital SatLock Operating Manual

ATLANTA ASF 2033HD+ DVB-S/S2 METER. User`s Manual

SATFINDER 3 HD SLIM USER GUIDE

Specifications. Dual Satellite Tracking Meter. With a built in 22Khz tone generator. Overview

Horizon HD-STM. Combo Signal Analyzer TEST REPORT

HD-TC8. HORIZON DIGITAL SATELLITE METER BPSK QPSK 8PSK Turbo Code

STM 17 HD. DVB-S2+T2/C Compact Meter. User Manual. Ref R13. CAHORS Digital CS Cahors Cedex 9 FRANCE.

PCM-1210 DVB COMBO METER User`s Manual

SZU OPERATING INSTRUCTIONS SAT NAVI

Contents. 1. General Information. 2. Contents. 3. Operating Instruction. 4. Program update. 5. Trouble Shooting. 6. Specifications

Single cable multiswich programmer PC102W

ST-4000 SIGNAL LEVEL METER

Operating Manual. DVB-T Meter MFK 16

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV

DIGISAT MULTI USER MANUAL

Super Installer Lite USER MANUAL

ST-4000D SIGNAL LEVEL METER

RF Mogul. Quick Start. Model: SDC1. Satellite Dish Controller

SM-10 SAT Level Meter User s Manual

Wireless 5.8GHz AV Sender With Built in Remote Control Extender

SAT IF distribution system

USER MANUEL. SNIPE 2 Ref R13

XR-3 QAM 8VSB. Modular Test Instrument. XR-3 Rugged Adaptable Economically Efficient Configurable to test: and more

HD/SD-SDI TO VGA CONVERTER. DAC-60 Quick Start Guide.

Noise Detector ND-1 Operating Manual

HD/SD-SDI TO VGA CONVERTER. DAC-60 Quick Start Guide.

Super Buddy Operation Manual

SNG-2150C User s Guide

Fully ly Automaticti. Motorised Satellite t TV System. User s manual. ver 3.0.

Table of Contents. 1. Safety Use. 2. General Description. 3. Connection Diagram. 4. Operations and Management. 4.1 Display Status. 4.

TR-2 OPERATION MANUAL

Cellular Signal Booster

Easy-to-use : setup, frequency maps, recorded data can be saved or downloaded from a USB memory stick.

SATELLITE FINDER SK-3200 USER MANUAL

Horizon Global Electronics Ltd.

EAGLE RE-1 CONTROLLER

Horizon Nano-S2. DVB-S2 Signal Meter TEST REPORT

Single & Dual Input HD Digital DVB-T Modulators

VNS2200 Amplifier & Controller Installation Guide

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

Xsarius Satmeter Pro. Manual

Horizon Global Electronics Ltd.

User s Manual of Signal Level Meter TABLE OF CONTENTS

Unicable II Programmer. IDLU-PROG01-OOOOO-OPP Item: Installation & User Guide

Universal DiSEqC controller USER MANUAL

Universal DiSEqC controller USER MANUAL SAT CONTROL

SATELLITE TV OPERATION / TECHNICAL MANUAL. Eagle II Controller

Bonding. Black Ground Wire Indicates # 17ga CCS Bond. Green Bonding Wire Indicates # 10ga Solid Copper. External Wall

Agilent FieldFox RF Analyzer N9912A

FRONT PANEL FUNCTIONAL SPECIFICATIONS

SATELLITE TV OPERATION / TECHNICAL MANUAL. Eagle II Controller

Chapter 4. Dish Antenna Installation. Installing a DISH 500 Antenna. Finding the Satellites

MODEL... MXL012/55NZ MXL012/65NZ SIMPLICITY AT IT S BEST SET UP & USER MANUAL REGISTERED COMMUNITY DESIGN NO

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Stevens SatComm FAQs For use with SatCommSet or Terminal Setup programs

GeniSys Display. Contractor s Tool. Description / Applications. for the GeniSys Advanced Burner Control

INSTRUCTIONS FOR USE Pro-Ject Receiver Box S

Throughout the whole user manual, pay special attention to the following marks that

Satellite locator WS-6933

HD-1600 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

Keysight FieldFox Microwave Analyzers

INSTRUCTION MANUAL SATELLITE. Version V4.0. NTi R. NTi. 13V[] 17V[] 22Kc[]> TBrst[] DiSEqC[] ü. Edition 11/2004 DILAN 2150 SAT LEVEL METER

8dtek DSM Desired. Business Voucher Direct Contact to Sales Manager. TELE-satellite Magazine

Interactive Satellite Terminal Installation / Validation Manual

Model Two and Model Two Lite Signal Level Meters OPERATION MANUAL

EAGLE RE-1 CONTROLLER For Use On MotoSAT HD Mounts

JD725A Cable and Antenna Analyzer - Dual Port

Cellular Signal Booster

Home Roam TV Basic User Manual

Satellite Signal Meter TEST REPORT 该独家报道由技术专家所作. 8dtek DSM Gifted. 30 TELE-satellite Global Digital TV Magazine 06-07/2011

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica

V TV / SATELLITE DC Power Tester

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

User s Guide. 5.8GHz Wireless A/V Signal Sender

IMPORTANT SAFETY INSTRUCTIONS

RMS 8424S Quick Start

VNS2210 Amplifier & Controller Installation Guide

Interactive Satellite Terminal Installation / Validation Manual

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM

Reflecta Super 8 Scanner. User Manual

FRQM-2 Frequency Counter & RF Multimeter

16 channels transmodulator S2C16

OSD. EXECUTIVE / MiniDome USERS MANUAL. USING THE MOTOSAT DISH POINTING SYSTEM EXECUTIVE / MiniDome OSD

Model Three Signal Level Meter. Operation Manual

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Operation and Installation Guide

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

Mini Micro Pulse Lidar System

minihomer TM User s Guide

Product Manual. Designed and Manufactured in the UK by Optikinetics

ELLIPTICAL ANTENNA E0851B11

Transmitter Interface Program

Transcription:

Ver: 0814us SAM Satellite Meter User Manual

Notes. 3

Table of contents 1. Introduction... 2 Chapter Page 2. Supplied items... 3 3. Getting started 1. Creating a Maxpeak user profi le... 4 2. Product registration, connect to PC... 56 3. Download Firmware and Settings... 4. Charging procedure... 7 5. Touch-wheel control... 8 6. Power up and shut down... 9 7. Dish installation... 10 8. Peaking the dish... 11 9. DirecTv Ka /Ku peaking... 13 10.... 14 11. Dishnetwork Dish Pro + peaking... 15 12.... 16 13. Setup view... 17 14. Battery replacement... 18 15. Specifi cations... 19 16. Warranty... 20 1

1. Introduction Thank you for purchasing our satellite alignment meter. It should provide years of trouble free operation. Please read this guide to familiarize yourself with all features and options available. Be careful with satellite dish pointing not to injure others by dropping tools or hurting yourself by falling down. Take care of the meter and keep it warm and out of the rain. Please note in severe cold weather the battery capacity could be greatly reduced. Store it in warm condition prior to use and keep the battery fully charged. 2

2. Supplied items Maxpeak SAM Satellite Alignment Meter with leather case Spare F to F Connector USB Cord A/C charger Power cord for A/C charger Car socket D/C charger 3

3. Getting started Before using the instrument, a full charge should be performed (as described in chapter 4). On our website www.maxpeak.tv ; Click on the new instrument wizard and follow a few steps to create a user profile and download firmware and settings. 1. Create a Maxpeak user profi le: Navigate to our website: www.maxpeak.tv The website senses your location and language automatically. If your language choice is different and available, click on the flag in the top right hand corner. The website language is the language that will be loaded in the fi rmware. E.g. if you have selected English, then the meter will be in English as well. Create the profile. Enter the security number from the picture. Enter a User name and Password and valid email address. The e-mail address entered in the procedure needs to be valid. A confi rmation e-mail is sent to this address and your account will not enable until you reply to it. If you do NOT recive a confirmation email within 5 minutes, it is likley your virus program and / or email provider has treated the email as SPAM. Try to retreve the email or follow the alternative method. 4

The USB socket is located under the rubber molding at the instruments left side. 2. Product Registration, connect to pc: Connect the meter to the computer Lift rubber molding on left side of the instrument to reveal the USB socket. Connect the USB lead from the instruments USB socket to the computer USB interface. If connecting for the first time: follow the Windows driver installation process. Help with driver installation is available from our website, www.maxpeak.tv/support.php If windows can t find the driver it can be downloaded from our support pages. Register product online Make sure the instrument is connected to the computer. Go to our website and login to your user profile. In the left side menu, Click Register a product Follow the instructions given at the product registrations page. Help with product registration is available from our website, www.maxpeak.tv/support.php 5

Before updating firmware and download settings, remember to be logged in with a Maxpeak user profile and that the instrument is connected to the computer. 3. Update fi rmware and download settings: Firmware update Make sure to be logged in at the maxpeak website and that the instrument is connected to the computer. In the top right menu, click Products. Then in the left menu, click Firmware Download. Follow the instructions given at the Firmware Download page. Help with firmware download is available from our website, www.maxpeak.tv/support.php Settings download Make sure to be logged in at the maxpeak website and that the instrument is connected to the computer. In the top right menu, click Products. Then in the left menu, click Settings Download. Follow the instructions given at the Settings Download page. Help with settings download is available from our website, www.maxpeak.tv/support.php 6

4. Charging procedure The meter is delivered with a nominal charge only. It needs 24 hours of initial charge before usage. The battery reaches full capacity after a couple of charges. Charging procedure: The charging socket is located under the rubber molding at the right side of the instrument. Only use the included car or wall socket chargers for charging. Lift the rubber molding on the top right side of the instrument to reveal the charging socket. Plug the cord from either the included car 1 or wall socket chargers to the instrument. Please note that warranty is voided if a charger other than the one supplied from Maxpeak is used. Now the battery is charging. A full charge will take 3 hours (after initial charging). Charging circuit drops to trickle when fully charged. The meter may get warm during charging. This is normal. Press Select button to put the meter in meter mode 2 while charging, after 10 minutes the meter returns to the standby screen CHARGING TRICKLE CHARGE Select Press Select to use the meter while charging Charged 50% 01h20m 1h20m Charge screen Time Left Time since completed 100% +00h10m FULL Charge completed screen 7 1 Some vehicles need ignition turned on in order to provide power to the cigarette lighter socket. 2 Using the instrument while charging may result in less accurate measurements.

5. Touch-wheel control Up The meter is controlled using a touch sensitive wheel and a distinctive Select button at the wheels center. Left Right The meter is switched ON/OFF by keeping the Select button pressed. Down Select A shorter SELECT click 1 is used for data entry in the Setup view and DISEqC menu. The wheel can be used in two ways: Clockwise Slide Quick Step Right/Down Standard four way navigation, by clicking 1 the wheel in each direction as shown in the top picture. Quick Left/Right stepping of values by sliding clockwise or counterclockwise as in the bottom picture. Counterclockwise Slide Quick Step Left/Up 8 1 A click is triggered on release, when the finger is lifted, not when pressing.

6. Power up and shut down To turn the meter on, keep the Select button pressed for five seconds. At startup, the following information is displayed: Power Up: Keep the Select button pressed. c Maxpeak Ltd 2006 Firmware: FM1.00 Settings file: US.001 The meter then changes to the meter view: Firmware and settings file versions are displayed. To freeze this information, keep holding the Select button. BR S DirecTV S SEARCHING 101w 65dBuV The meter is now up and running. For the functionality available, please see: Chapter 8 - To peaking the dish Chapter11 - Setup view. Shut Down: Keep the Select button pressed. To shut down the meter, keep the Select button pressed, (as when turning on the meter). When switching off, this screen is displayed: Powering down 9

7. Dish installation First find a suitable place to install the dish. It should have a clear line of sight (use a compass to find azimuth angles (sideways). Make sure there are no overhead obstructions like trees, buildings etc. Next, assemble the dish according to the dish manufacturer s instructions. Install the LNB. Obtain the elevation and polarization for the required satellite and location, usually supplied with the dish or in the receiver software. Preset the dish elevation (up/down) angle first. There may be a scale on the back. An inclinometer may be of use if you know the dish elevation offset angle. Set the feed rotation polarization angle also. There may be a polarization rotation scale on the LNB feed horn throat. Or in some markets the dish has screws and a scale on the back to set this. Next use a compass to roughly set the azimuth. Hook up the SAM meter to the LNB. Switch on the meter, gently move the dish until the meter changes from searching to found. Peak the dish for maximum Q. If reception is dual polarity peak the optimum Q for both polarities. Follow all Local, State and National grounding requirements. Be careful with satellite dish pointing not to injure others by dropping tools or hurting yourself by falling down. 10

8. Peaking the dish Hook up the lnb via the F to F lead. Use high quality threaded F connectors for your installation. Low quality connectors will negatively affect the accuracy of the readings Do not use push-on F connectors as they are very unreliable, especially when they have been used a few times. Connect the F to F lead from the LNB to the F connector at the bottom of the instrument. Connect the other end to the bottom of the meter and power up. Connect the leads first and then power up the meter. The meter view: Initially the meter displays signal level and starts to search for a match. Enter Setup View: Hold Up. Select Next Setting: Clockwise Slide or Right Click Select Previous Setting: Counterclockwise slide or Left Click. List of available DISEqC Commands Hold Down. Satellite RF Level BR S DirecTV S SEARCHING 101w 65dBuV To choose among settings, click Left / Right or slide the wheel. Enter Setup view by holding Up. Azimuth Peak Hold indicator Enable / Disable in Setup View The menu of available DISEqC commands is shown by holding Down. In the DISEqC menu, choose command with Up / Down click or slide the wheel. Send selected command by clicking Select or close by clicking Select with Exit menu selected. 11

When the dish is pointed to the correct satellite, the meter will beep twice and change from searching to FOUND to indicate identification of correct satellite. A Q 1 bar appears that needs to be maximized. The information available depends on which display mode is selected. The display mode of the Meter view can be set in the Setup view. An option for S to be displayed in dbuv or dbm and an option to display M 2 (MER) or C 3 (SNR) in any of the variants can be found here as well. RF Level Reverse BER / Quality RF Level Classic S BR DirecTV S Q Simple S BR DirecTV Q FOUND 101w 65 dbuv FOUND 101W Fail, Marginal or Pass 101w 65dBuV 75% 101w Pass Reverse BER / Quality Reverse BER / Quality RF Level MER Level or SNR RF Level MER Level or SNR All BR S DirecTV S Q C BR S DirecTV S Q C Pre BER FOUND 101w Scientifi c 101w 65dBuV 75% 9dB 101w 65dBuV 75% 9dB A 3.0E-3 B 2.3E-5 Post BER 1. Q= Quality / Reverse BER (Bit Error Rate) with FEC compensation. E.g. the highest value will give best signal 2. M= MER (Modulated Error Rate). A digital level of carrier (signal)/ noise but with the phase fault in the transmission 3. C= C/N. Carrier (signal) / noise level 12

9. DirecTV Ka / Ku peaking. The DirecTv Ka / Ku band ODU is in fact 5 lnb s integrated in one housing. To align this dish DirecTv is recommending to peak the 101 and 119 West satellites. As all lnb s are fixed, simply by peaking these all the rest will be automatically peaked. To simplify and speed up this type of ODU, the meter has a DUAL MODE. Simply select the Dual DirecTV setting Hook up the meter via an F connector to one of the ports on the lnb. Initially the meter, is in search mode. Uniquely for this dish setup, there is two bargrapghs, that shows the Rf level for 101 and 119 West. RF Level for 101 West RF Level for 119 West Dual DirecTv SEARCHING S S SEARCHING 101/119 65dBuV 68dBuV Azimuth TM Upon a FOUND E.g. identification and lock of the satellite, the S bargraph goes away and the Q bargraph, for quality is displayed. The RF level is now displayed, together with CN or MER and preber (numeric only) Reverse BER / Quality Reverse BER / Quality Dual DirecTv 101/119 S 46 C 12.0 A 3.0E-3 Q 65 % Q 68 % S 47 C 11.8 A 2.5E-3 101 West 119 West S = RF level C = Carrier Noise M = MER A = pre BER Connect the F to F lead from one of the ports on the LNB to the F connector at the bottom of the instrument. Instead of going back and forth to check the lock and peaking, in one simple step: just peak both bargraphs. DirecTV and Slimline are TM of DIRECTV Group Then follow the instruction for fine tuning (dithering) in the user guide for the ODU. Please note; for this setting only this display is available, no matter what is selected in the setup menu. 13

10. 14

11. Dishnetwork Dish Pro + peaking. The Dishnetwork Dish Pro + lnb is in fact 3 lnb s integrated in one housing. We recommend to peak the 110 and 119 West satellites. As all lnb s are fixed, simply by peaking these all will be automatically peaked. To simplify and speed up this type of lnb, the meter has a DUAL MODE. Simply select the Dual DishNetwork setting Hook up the meter via an F connector to one of the ports on the lnb. Initially the meter, is in search mode. Uniquely for this dish setup, there is two bargrapghs, that shows the Rf level for 110 and 119 West. RF Level for 110 West RF Level for 119 West Dual DishNetwor SEARCHING S S SEARCHING 110/119 65dBuV 68dBuV Azimuth TM Connect the F to F lead from one of the ports on the LNB to the F connector at the bottom of the instrument. Dish Pro + is a TM of Dishnetwork Inc. Upon a FOUND E.g. identification and lock of the satellite, the S bargraph goes away and the Q bargraph, for quality is displayed. The RF level is now displayed, together with CN or MER and preber (numeric only) Reverse BER / Quality Reverse BER / Quality Dual DishNetwor 110/119 S 46 C 12.0 A 3.0E-3 Q 65 % Q 68 % S 47 C 11.8 A 2.5E-3 110 West 119 West S = RF level C = Carrier Noise or M=MER A = pre BER Instead of going back and forth to check the lock and peaking, in one simple step: just peak both bargraphs. Please note; for this setting only this display is available, no matter what is selected in the setup menu. 15

12. 16

13. Setup view Enter Setup View: Hold Up for 3 seconds. Hold finger at the top to enter set up mode. Slide the wheel or press Left/Right to navigate the list of options Press the center of the wheel to make a selection. The Setup view is where settings and personal preferences are set. Enter the Setup view by holding Up on the wheel. SETUP MENU Exit menu Backlight: Sounder: Auto shutdown: Meter mode: On Off 6 min Scientific The following settings and choices are available: Exit menu: Exit back to Meter view Backlight: On, Off Display backlight. Turn off when not needed to save battery time. Sound feedback while peaking signal. Beeps faster as signal quality increases. Sounder: on, off Auto shutdown: never, 3-15min Time before meter shuts off to save battery, default=6 min. Meter mode: All, Scientific, Classic, Simple The meter modes determine the data entities displayed in meter view. (see chapter 7 - Peaking the dish) for details. RF Level: dbuv, dbm Select RF Level display. SNR/MER: SNR, MER Select whether to display SNR or MER value Peak Hold: On, Off Touch sens: Restore to default: Low, Medium, High A vertical hold line indicating the top value reached. This applies to all meter bars. Adjust the touch wheel sensitivity. Restore the setup view menu values to factory defaults 17

14. Battery replacement Remove the screw located at the upper back side of the instrument. The meter is powered by a replaceable NiMH battery pack. As with all batteries the pack will deteriorate with time. To ensure good lifetime of the battery pack, make sure to use/discharge and recharge the meter frequently When the battery pack needs to be replaced, spare packs can be ordered from an authorized reseller. Do not use any other kind of non authorized batteries. A different pack can damage the meter and make the warranty invalid. Take away the battery lid and disconnect the current battery pack. Attach the socket of the new battery to the connector on the instrument. Put the battery pack in place and put back the lid and screw. Battery Replacement: Changing the battery pack is a simple procedure. Unscrew the screw and take away the battery lid. Remove the battery and disconnect the plug. Connect the new battery pack to the plug. Place the pack as shown in the bottom picture to the left. Initially charge the meter for 24 hours as described in chapter 4 - Charging. 18

15. Specifi cations High sensitivity -75dBm C, Ku, Ka or L band Replaceable F-connector 75 Ohm imp 30 to 100 dbuv RF level as dbm or dbuv.range -90 to -20 dbm 17 dbuv to 87 dbuv Precision+- 2.5 db True MER or SNR displayed in db Range 3 to 16 db Precision +- 1dB Pre and Post BER in numerical value Range preber 0.001 % to 10 % Precision +- 5 % Quality displayed in % (reverse BER) RF, BER,MER displayed together Backlite graphics display 128x64 dots Integrated rechargable NiMH battery 12 V (10 cells) 2250 ma Charged from wall adaptor or car Upto 60 sats Upgrade of settings via USB 2.0 Upgrade of firmware via USB 2.0 Language option via USB 2.0 Built in audible sounder DiSEqC switch commands and 22 K tone Run time in excess of 4 hours, charge time 3 hours 9.5 Lx3 Wx2.5 H 28 oz. Charge type: Sophisticated Fast/ trickle charge with auto top off. Using Delta V/ T for long life. Dedicated LNB driver with auto compensation and current limit of 650 ma The manufacture reserves the right to change this specification without prior notice. 19

16. Warranty This product carries a manufacturer s warranty against faults or manufacturing defects for a period of 12 months from purchase. Maxpeak reserves the right to replace or repair a faulty meter. The warranty doesn t cover moisture damage, misuse, damage caused by dropping the meter or if the meter has been opened. Declaration of conformity: We, the manufacturer, Maxpeak Ltd 2nd Floor Compton House 29-33 Church Road Stanmore HA7 4AR ENGLAND declares that SAM (satellite meter) meets the following standards and directives: Low voltage : 73/23/EEC, 93/68/EEC EMC: 61000-6-1:2001 61000-6-3:2001 and amendment A11:2004 RoHS P Lagerstedt (Director) Bridgetown 13:th of Feb 2007 Recycle: Please recycle the carton and packaging. Do not throw out the NiMH battery, but please recycle instead. Do not discard the meter at the end of useful life, again recycle. Check our website for the latest information. 20

21

info@maxpeak.tv US Distrubitor: Perfect 10 Satellite Distributing 3901 Progress Street North Little Rock, Arkansas 72114 USA 1-800-205-8620 www.perfect-10.tv www.maxpeak.tv 22