LCS 2 RJ 45 Cat. 6A HD panels and units

Similar documents
LCS2 Cat. 6 RJ 45 Patch panels and units

CATEGORY 6 CABLING SOLUTIONS

Volition TM RJ45 K5e Jacks

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

Class E A / Cat.6A Screened Coupler

HighBand 25. TrueNet Category 6 Solutions

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

CATEGORY 5e CABLING SOLUTIONS

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

TB876BSX-3WH Class E A / Cat.6A STP Keystone Jack (Auto press-fit)

HARTING Ethernet cabling cables and connectors, 4 wire

CATEGORY 6A CABLING SOLUTIONS

Magic Patch Patch Leads & Accessories

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

STRUCTURED CABLING SYSTEMS (SCS)

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Single Point Flow Monitor SW118 SW119

PREMIUM 5e F/UTP PRODUCTS

CATEGORY 6A CABLING SOLUTIONS

BTNS TM. FTP Compact Module

Copper Solution Contents Cabinets Fiber Optic Solution

DINTEK LAN Cabling Systems

Compact Module. Category 6 FTP Cabling System

Dimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1

Horizontal or Vertical PCB contacts Bulk Packaging LED colour - Red, Green, Yellow or Blue combinations. Ordering Codes

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS

What really changes with Category 6

Cat.6 4 Pair UTP Cable

Roof-mounted Blue e+ cooling unit Integration solution VX25

technicalreport MegaLine Connect100 Class E A links over 100 metres in length Data communication technology 09/2018 Classic structure 2-connector link

10 PDUs 19 PDUs Zero-U PDUs

Clarity. Advanced solutions for 10 Gig, Category 6 and 5e copper connectivity PRODUCT SOLUTION GUIDE EXPERTISE. TECHNOLOGY. SOLUTIONS.

CAT 6 Data Wiring System Connectors

August " BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19" PATCH PANEL - 24x STP CAT6A PORTS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

CAT 6 Data Wiring System Connectors

Filters for Power Lines (Low Leakage Current)

Multi-Channel Passive Transceiver Hubs Installation Sheet

SPECIAL SPECIFICATION 2344 TMC Support Equipment

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

Connect with the industry s best CAT6 and CAT5e channel solutions!

CAT6Plus System. Brand-Rex Limited

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Best Friends General Trading FZE

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Connecting cables for valves, round plug connectors Product range overview

KVT Split cable glands

SERIES 400 SERIES 620

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Power Injector 1520 Series

btnet new products Modular and preloaded patch panels btnet

6-Connector- Channel-Link Class E A (STP)

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

COLORED CATEGORY 5e BULK CABLE, SOLID-CONDUCTOR PATCH CABLE, & CATEGORY 5e BACKBONE CABLE

Ethernet Series. Etherplug Etherlink V Etherlink V Specialty Connectors Specifi cations...

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

0.4 mm Pitch, Horizontal mating, Board- to-fine Coaxial Cable Connectors

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

DIN EUROCARD CONNECTORS

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

PATCH PANEL Easy Patch INSTRUCTION MANUAL

Modular pulse operated latching relay 16 A

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.

Panel-mounting thermostats, type series EM

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Volition TM Category 5e cable 100 Ω, FTP

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras


MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

0.3 mm Pitch, 1.5 mm Mated Height, Board- to-fine Coaxial Cable Connectors

SECTION 7 -- CROSS-CONNECT SYSTEMS

C6 A modul and C6 A modul K. The new connection system for a wide variety of applications of course with Cat.6 A

INTERNATIONAL STANDARD

CAT5E NETWORK PATCH LEADS

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

Bimetal Temperature Switch

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Simple View TM. From the beginning to the end. We leave nothing out when it comes to your satisfaction.

1x12 VGA & Audio over CAT5 Splitter

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

EXPlora. Introduction


Table of Contents. Open Matrix System (OMS) 1-2

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

SECTION COMMUNICATIONS HORIZONTAL CABLING

LANmark. Copper Cabling Solutions

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Transcription:

87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: +33 (0)5 55 06 88 88 Page 0 335 85/86 1. General characteristics....1 2. Presentation...1 3. Positioning...1 4. Technical characteristics...1 5. Installation...2 6. Dimensions....2 7. Standard RJ 45 connection...2 8. Standards and approvals...3 9. Performance....3 1. GENERAL CHARACTERISTICS Universal mounting on any cabinet or enclosure. Panels ensure automatic earthing of each connector. The patch panels are 19 format - 1U. They are equipped with: - 4 of 6 quick-fixing RJ 45 Cat. 6A connectors (no tools required), with 568 A/B marking - Soluclip accessory for automatic fixing (without screws) to the uprights in cabinets and enclosures - Rear cable guide to hold cables during maintenance Does not require a cable management panel. Supplied with colour labels numbered 1 to 24. 3. POSITIONING No special tool is required to connect the connectors. 2. PRESENTATION Description STP Weight (g) - Connector simply snaps onto the front of the panel - Fastening of the label holder faceplate ensures a neat finish for the 6 connectors No need for cable ties: the cable is held in place in the cable guide. 4. TECHNICAL CHARACTERISTICS Panel - 24 x RJ 45 Cat. 6A 0 335 85 0 335 86 16 4.1 Characteristics of the materials Panel: DC01 galvanised sheet steel Unit: RAL 9005 polycarbonate Connector: - Contacts: gold/nickel, thickness of gold > 0.8 m minimum - Metal parts: bronze, nickel, platinum, gold - Polycarbonate PBT For the STP modules the body and the spreader are made of metal alloy with copper and nickel coating. The STP connectors have a steel ring for 3 earthing. 4.2 Electrical characteristics Breakdown voltage 1000 V Contact resistance m Insulation resistance 500 M at 100 Vdc Connector tested and guaranteed under POE signal stress, standard IEEE 2.3af and POE+, standard 2.3at, up to 2500 load connections/ disconnections. Tests are carried out with 2 simultaneous POE+ circuits for a minimum total power of 50W. 1/5

4. TECHNICAL CHARACTERISTICS (continued) 4.3 Mechanical characteristics Maximum number of connections and disconnections: 5 without replacing the wire Endurance: 2500 operations (plug-in/pull-out) IK03 4.4 Climatic characteristics Operating temperature: - C to + 70 C Damp heat: 21 day cycle 5. INSTALLATION 7. STANDARD RJ 45 CONNECTION Takes the following plugs: RJ 11 (4 contacts), RJ 12 (6 contacts), RJ 45 (9 contacts). EIA/TIA 568 A and B dual colour code on terminals: - STP 9 contacts with 3 shielding ID no.: SB 63 Cat. 6A colour code: yellow 12345678 12345678 L1 L3 L2 L1 90 m L2 5 m L3 5 m EIA 568 A EIA 568 B Permissible conductors: - Single-core: 0.5 to 0.65 mm, AWG 22 to 26 - Multicore: AWG 26 - Polyethylene conductor insulation: maximum Ø on insulation 1.58 mm RJ 45 connectors are equipped with a locking nut. They do not require a special tool and can be re-wired if a mistake is made. OK 6. DIMENSIONS Patch panel Cat. No. 0 335 85/86 482.6 43.8 1 NO 118.0 78.5 Simultaneous connection of the strands is thus assured. This system allows you to spread pairs with ease before fitting them onto the connector. 2 3 2/5

7. STANDARD RJ 45 CONNECTION (continued) Spreading the cables ensures that a pair-breakage distance of 13 mm is kept between each pair. Spreading pairs at 90 to the cable ensures the best possible performance. 9.1 Performance of permanent link with S/FTP cable NEXT (Near end Crosstalk Attenuation) 8. STANDARDS AND APPROVALS Conforms to standards: ISO/IEC 111 CENELEC EN 50173 ANSI/TIA 568 C.2 ISO/IEC 3-7 series 9. PERFORMANCE 9.1 Performance of permanent link with S/FTP cable Return loss 10 PS NEXT (Power Sum NEXT) 10 Attenuation 10 ACR (Attenuation to Crosstalk Ratio) -2 0 10 8 3/5

9.1 Performance of permanent link with S/FTP cable (continued) ELFEXT (Equal Level End Crosstalk Attenuation) 9.2 Channel performance Return loss 10 10 Delay skew 0 ns Attenuation 100 ns 10 NEXT (Near end Crosstalk Attenuation) 10 4/5

9.2 Channel performance (continued) PS NEXT (Power Sum NEXT) 9.2 Channel performance (continued) Delay skew 0 ns 10 100 ns ACR (Attenuation to Crosstalk Ratio) -2 0 8 ELFEXT (Equal Level End Crosstalk Attenuation) 10 5/5