ELECTRON OPTICS OF ST-X, ST-Y SERIES OF STREAK & FRAMING CAMERA TUBES

Similar documents
CBF500 High resolution Streak camera

Image Intensifier User Guide

The hybrid photon detectors for the LHCb-RICH counters

Teltron Delection Tube D

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Operating Instructions for PMT Tube P3

INSTRUMENT CATHODE-RAY TUBE

ITS-I. Test station for evaluation of image quality of image intensifier tubes. Fig. 1. Photo of the ITS-I test station: a)photo, b)block diagram

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

CNT FIELD EMISSION CATHODE CATALOG. XinRay Systems Inc. April 2014

Characterizing Transverse Beam Dynamics at the APS Storage Ring Using a Dual-Sweep Streak Camera

CHAPTER 4 OSCILLOSCOPES

INSTRUMENT CATHODE-RAY TUBE

PAST EXAM PAPER & MEMO N3 ABOUT THE QUESTION PAPERS:

Experimental Astrophysics Group, Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720

Display Systems. Viewing Images Rochester Institute of Technology

Single-sided CZT strip detectors

Computational Studies of X-ray Framing Cameras for the National Ignition Facility

IMPROVEMENTS IN THE CONSTRUCTION OF CATHODE.RAY TUBES

CX1725W Liquid Cooled, Hollow Anode Two-Gap Metal/Ceramic Thyratron

The Time-of-Flight Detector for the ALICE experiment

TESLA FEL-Report

High ResolutionCross Strip Anodes for Photon Counting detectors

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications

Observation of vacuum arc cathode spot with high speed framing camera

Universal streak camera C10910 series

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

The Effect of Plate Deformable Mirror Actuator Grid Misalignment on the Compensation of Kolmogorov Turbulence

Svetlana 3CX10,000A7/8160

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

Triggered breakdown in lowpressure hollow cathode (pseudospark) discharges

Sep 09, APPLICATION NOTE 1193 Electronic Displays Comparison

Kentech Instruments Ltd.

Tests of Timing Properties of Silicon Photomultipliers

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

Measurement of Microdisplays at NPL

Analog Circuits Prof. Nagendra Krishnapura Department of Electrical Engineering Indian Institute of Technology, Madras. Module - 04 Lecture 12

MCP Upgrade: Transmission Line and Pore Importance

Photo Multipliers Tubes characterization for WA105 experiment. Chiara Lastoria TAE Benasque 07/09/2016

3B SCIENTIFIC PHYSICS

E2V Technologies CX2668A, CX2668AX Air-Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

Data. X-ray Image Intensifier HIDEQ 23-3 ISP

Production and Development status of MPPC

Large Area, High Speed Photo-detectors Readout

The 20 inch MCP-PMT R&D in China

STUDIES OF ENHANCED EDGE EMISSION OF A LARGE AREA CATHODE *

Linac 4 Instrumentation K.Hanke CERN

Photon detectors. J. Va vra SLAC

HAPD and Electronics Updates

Lifetime of MCP-PMTs

Drive Laser Operations

arxiv:hep-ex/ v1 27 Nov 2003

Screens; media that use additive primaries

Lifetime of MCP-PMTs

4.9 BEAM BLANKING AND PULSING OPTIONS

Elements of a Television System

SPATIAL LIGHT MODULATORS

Table. J. Va vra,

2x1 prototype plasma-electrode Pockels cell (PEPC) for the National Ignition Facility

CCD220 Back Illuminated L3Vision Sensor Electron Multiplying Adaptive Optics CCD

Front End Electronics

Quantar Technology 3300/2400 Series Imaging Detector Systems

Beam test of the QMB6 calibration board and HBU0 prototype

Fig. 1. Hawk switch/load vacuum section in the standard configuration.

OPTICAL TEST EQUIPMENT

MPPC (multi-pixel photon counter)

Performance of the MCP-PMT for the Belle II TOP counter

Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode. R.Bellazzini - INFN Pisa. Vienna February

These tests will be repeated for different anode positions. Radiofrequency interaction measurements will be made subsequently. A.

Tuesday, July 27, Testing and Characterization Plans

The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Spatial Light Modulators XY Series

Thyratrons. High Energy Switches. Features. Description

K800 RF AMPLIFIER TUBE UPGRADE

CR7000. CRT Analyzer & Restorer. Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security.

Y.XST225-VF. INTERCONTROLE Escoffier 1 XYLON MG225VF RX PDS

Financial disclosure statement. Fluoroscopic Equipment Design: What s s Different with Flat Panel? Concept of flat panel imager

Selection Criteria for X-ray Inspection Systems for BGA and CSP Solder Joint Analysis

In-process inspection: Inspector technology and concept

CCD Datasheet Electron Multiplying CCD Sensor Back Illuminated, 1024 x 1024 Pixels 2-Phase IMO

Basically we are fooling our brains into seeing still images at a fast enough rate so that we think its a moving image.

Physics Requirements for the CXI Ion Time-of-Flight

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

THE TIMING COUNTER OF THE MEG EXPERIMENT: DESIGN AND COMMISSIONING (OR HOW TO BUILD YOUR OWN HIGH TIMING RESOLUTION DETECTOR )

Particle-in-cell simulation study of PCE-gun for different hollow cathode aperture sizes

Progress Update FDC Prototype Test Stand Development Upcoming Work

3 EXPERIMENTAL INVESTIGATIONS Caroline Robson. 3.1 Aims and Objectives. 3.2 Experimental Method Set Up of the Test Stand

UVscope an instrument for calibration support

Module 3: Video Sampling Lecture 16: Sampling of video in two dimensions: Progressive vs Interlaced scans. The Lecture Contains:

TORCH a large-area detector for high resolution time-of-flight

High performance optical blending solutions

PanelView 1400e CRT Maintenance

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

SY-401V PC/HD to Video Scan Converter OPERATION MANUAL

Front End Electronics

Overview of All Pixel Circuits for Active Matrix Organic Light Emitting Diode (AMOLED)

Optimization of a triode-type cusp electron gun for a W-band gyro-twa

Transcription:

ELECTRON OPTICS OF ST-X, ST-Y SERIES OF STREAK & FRAMING CAMERA TUBES INTRODUCTION The basic electron optics of this range of streak tubes were designed by Ching Lai at the Lawrence Livermore National Laboratory (LLNL) and used by ITT in the F47 Series tubes. Mechanically, the Photek ST-Y tube is a form fit socket replacement, for the ITT F47 RCA/Burle 74 and the Photonis P and P series tubes, whilst the ST-X tube is a form fit replacement for the smaller Photonis P9 tube. Both the ST-X and ST-Y versions are of a metal-ceramic construction with a remotely processed photocathode. The ST-X is 6% scaled from ST-Y. The first focus electrode can take the form of a slot or a mesh. The mesh intercepts about 4% of the photo electrons, but ensures uniform focussing across the entire area of the photocathode. It also enables one to use a stronger field at the photocathode, giving the ultimate in the time response, and dynamic range. The distance between mesh and cathode can be adjusted to increase time resolution and dynamic range in streak applications, but not if the tube is intended for use in a framing camera, as this will make the setting of the mesh voltage unduly critical for best spatial resolution. The size of the mesh aperture can be adjusted to suit the number of frames needed in a sequence. For example, the maximum aperture with a single frame would be mm with ST-Y, but an aperture of mm allows four sequential images to be addressed by X-Y deflector plates.. OPTIMUM SPATIAL RESOLUTION (FRAMING MODE) The graph shown in figure gives an indication of how voltages can be adjusted to vary the magnification in the range.6 to.. Both distortion and edge resolution fall away either side of the optimum magnification at.8. For example, distortion increases from.% at.8 to % at. or % at.6. At.8 magnification, both distortion and edge resolution are significantly improved from the ITT design by using a curved phosphor screen. With the curved screen the resolution is limited only by the phosphor screen at all radii. Issue 4..7 Technical Notes/Electron Optics: 7

Volts 4 4 9 9 8 8 7 7 6 6 4 4 - - V 6 V g 9. 4. 6. 8. 8 8 M a g n i fi c a t i o n V / 8-8 7 Figure Magnification The measured spatial resolution of prototype tubes at.8 magnification ranges from -6 lp/mm, with distortion virtually impossible to detect. The calculated time response in streak mode is ps. Since the capacitance between photocathode and grid is less than pf, it should be possible to gate the tube on/off very fast, with a pulse approximately V.. STREAK MODE WITH A SLOT Using a slit in place of a mesh ensures that all photo electrons are recorded and maximises the photon efficiency of the tube. Because ST-Y and ST-X have an extra electrode, it is possible to increase both the slot voltage and first focus electrode to minimise the anisotropic (or cylindrical lens) effect of the slot electrode. The second focus electrode is used to compensate and bring the tube into focus. However, as the slot voltage is increased, the tube can only be truly focussed in one axis. The table below, shows focus voltages to achieve 4 lp/mm in the time direction. In the spatial dimension, the minimum resolvable element grows, as one increases the cathode field to improve time resolution. Issue 4..7 Technical Notes/Electron Optics: 7

Focus Conditions of ST-X (Cathode at, Volts, Screen & Anode at V) VOLTAGES Grid - Ug Focus U MAGNIFICATION Focus Time Spatial Resolutio n Spatial Micron Working Area (mm) 8X Time Resolutio n PS CTR EDGE 4,8 4,,.8.8 4. 6 4,7,,7.68.7 4. 7-8 4,, 4,.64.8 4. - 4,, 4,7.6. 7.4 -,6, 4,4.6. 84. 4-8 The magnification of the tube also changes, increasing in the spatial direction, but falling in the time direction. There is some difference in time resolution from the centre of the tube to the extreme edge as shown in the table. Since ST-Y is exactly the same electron optically as ST- X, it will achieve exactly the same performance as indicated for ST-X, but at a higher overall voltage of approximately kv. The working area of ST-Y is x mm whereas ST-X is set to 8 x mm.. STREAK MODE WITH A MESH The voltage between cathode and first focus mesh (Ug) has to be increased to achieve fast streak mode. The extra focus electrode in the Ching Lai design enables a far wide range of options for doing this than older tube designs. Figure below shows that the ultimate time resolution is less than a picosecond in the extreme case where Ug =, V (Cathode V, Screen, V). Issue 4..7 Technical Notes/Electron Optics: 7

Temporal resolution Tcentre,Tedge, ps 7 6 4 4 6 Tcentre Tedge 4 6 Ug, V Figure The dependence of temporal resolution at the centre and at the edge (R =9mm) on the grid potential,4 Ug = U = 64.8 V U = 78. V, Ug = U = 44.8 V U = 647.9 V,6 Ug = U = 9.4 V U =. V However Figures and 4 show that distortion and edge resolution are also severely degraded. The consequence of this is that the time resolution also falls away at the edge. Distortion A, % 4 6 Ug, V A % Figure - The dependence of distortion at the edge (R =9mm) on the grid potential Ug = U = 64.8 V U = 78. V Ug = U = 44.8 V U = 647.9 V Ug = U = 9.4 V U =.V 4 Issue 4..7 Technical Notes/Electron Optics: 7

Meridional resolution at the edge Nm, lp/mm 4 6 Nm Ug, V Figure 4 - The dependence of spatial resolution at the edge (R =9mm) on the grid potential Ug = U = 64.8 V U = 78. V Ug = U = 44.8 V U = 647.9 V Ug = U = 9.4 V U =. V In another words, the working area is severely reduced as the tube is re-focussed for better time resolution. Figure shows how magnification also increases as Ug is increased. Electron magnification M. M. 4 6 Ug,V Figure - The dependence of electron magnification at the centre on the grid potential Ug = U = 64.8 V U = 78. V Ug = U = 44.8 V U = 647.9 V Ug = U = 9.4 V U =. V Issue 4..7 Technical Notes/Electron Optics: 7

It should be noted that these calculations all relate to a planoconcave input window that is, flat on the outside and curved on the inside. The optical path distance is therefore greater on edge of the working area than in the centre. This corresponds to.7 ps at 4 mm radius and. ps at 6 mm radius. The dynamic range is limited by Child s Law since the maximum current is proportional to V. divided by d, where d is the gap between photocathode and mesh. Optimum performance is then achieved at Ug =, with a smaller gap between cathode and mesh (.6 mm) The time resolution, centre to edge becomes better than ps, with a magnification of, negligible distortion and optimum resolution The dynamic range of such a tube is approximately twice that of the slot version despite the loss of photoelectrons in the mesh. In principal, time resolution can be improved into the sub-picosecond range on axis by increasing Ug to Volts, if off axis performance can be sacrificed. For further information please contact: Photek Limited 6 Castleham Road, St Leonards on Sea, East Sussex, TN8 9NS, UK Tel: +44 44 8 Fax: +44 44 8 E-mail: sales@photek.co.uk Web Site: www.photek.co.uk 6 Issue 4..7 Technical Notes/Electron Optics: 7