AN OVERVIEW OF THE REAL SCALE TESTS IN THE FIPEC PROJECT (FIRE PERFORMANCE OF ELECTRICAL CABLES)

Similar documents
WIRE AND CABLE FIRE TESTS

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

CORONA & PLASMA FOR NARROW WEB

CORONA & PLASMA FOR NARROW WEB

51109 Köln St. Asaph, Denbigshire LL17OLJ

UBC 26-2 Test Method for the Evaluation of Thermal Barriers. Contego International 7/16" OSB with Fire Barrier Latex

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE

Actuators IC 20, IC 40

All the energy of your home, in an App!

ASTM E a Fire Tests Of Building Construction and Materials *Modified SMALL-SCALE TEST OF FIREBLOCKING MATERIALS

FUNCTION IN FIRE EXPERT JUDGEMENT REPORT WITH CLASSIFICATION FIRES-JR NURE

JOURNAL OF BUILDING ACOUSTICS. Volume 20 Number

Performing a Sound Level Measurement

Projectors EFFORTS FOR PROJECTOR QUALITY

Racks, Cabling and Latency

In-Line or 75 Ohm In-Line

Installation Operation Maintenance

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

1. SAFETY & WARRANTY 2 2. WHAT IS CGM 3 3. SYSTEM SETUP (LINKING) Master to Group(s) Group to Channel(s) 3 4. CONNECT THE POWER 4

IGNITION TRANSFORMER FOR BURNERS

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Welding equipment for the POLYSTIC system

Cellular Signal Booster

DOME OPTIC SPLICE CLOSURE

Gamma instabus. Technical product information

The use of an available Color Sensor for Burn-In of LED Products

ANSI C63.4 and CISPR 22-Harmony

Linear flow control with actuator IFC

MP 35" Zero-G 100Hz Curved Monitor with AMD FreeSync 2.0

MP Zero-G 27" WQHD 144Hz TN-LED Monitor with AMD FreeSync

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

Chapter 10. Lighting Lighting of Indoor Workplaces 180

Note for Applicants on Coverage of Forth Valley Local Television

How to Implement PoE in Your Harsh Industrial Environment

TOSHIBA Industrial Magnetron E3328

Understanding the True Cost of Cable Cuts

INSTRUCTION & INSTALLATION GUIDE

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

SCHEDA TECNICA. Amarro per cavi 13,5mm Amarro per cavi 16,5mm. MS217F00 Amarro per cavi 13,5mm MS218F00 Amarro per cavi 16,5mm

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS AND BODIES COMMISSION

R&S BCDRIVE R&S ETC-K930 Broadcast Drive Test Manual

FUNCTION IN FIRE EXPERT JUDGEMENT REPORT WITH CLASSIFICATION IN FIRES-JR NURE

L xxx-C0720-K255

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

Flexible. Fast. Precise. PPU-E Pick & Place Unit

The Syscal family of resistivity meters. Designed for the surveys you do.

KNX Dimmer RGBW - User Manual

ROTARY ENCODER SELECTION. A Step by Step Guide

25W 9xxnm Uncooled Multimode Laser Diode Module

USER MANUAL. GOLDMUND LOGOS 1N-2N SPEAKER SYSTEM Active Speaker

SPECIFICATION. Spec No : VSS-1402-CS603B

ACTIVE IF SPLITTER/COMBINER UHP-IFS

Symbol Parameter Value Unit V CES Collector-Emitter Voltage (V BE = 0) 700 V V CEO Collector-Emitter Voltage (I B = 0) 400 V Emitter-Base Voltage

CX1725W Liquid Cooled, Hollow Anode Two-Gap Metal/Ceramic Thyratron

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

Twin City Fan & Blower

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

ASTM E119-00a Fire Tests of Building Construction and Materials. Sandwich Panels For Modular Construction. Project No.

BUL1203EFP HIGH VOLTAGE FAST-SWITCHING NPN POWER TRANSISTOR

ELECTRICAL INCIDENT REPORT BUSHFIRE NEAR 22 NUKKLGUP LOOP YALLINGUP WESTERN AUSTRALIA 5 JANUARY Report prepared by: EnergySafety WA EIS

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

2 Work Package and Work Unit descriptions. 2.8 WP8: RF Systems (R. Ruber, Uppsala)

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

Dimming actuators GDA-4K KNX GDA-8K KNX

Obsolete Product(s) - Obsolete Product(s)

Fixed Audio Output for the K2 Don Wilhelm (W3FPR) & Tom Hammond (NØSS) v August 2009

Measurement of overtone frequencies of a toy piano and perception of its pitch

ASTM E119-95a Fire Tests of Building Construction and Materials Sandwich Panel Wall System

from ocean to cloud ADAPTING THE C&A PROCESS FOR COHERENT TECHNOLOGY

All-Glass Sliding-System SF20

Channel Cable Tray - Accessories

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

LIGHT COPILOT II. elationlighting.com Internet:

Aerial Cable Installation Best Practices

There is much more behind

VIDEO WALL INSTALLATION GUIDE TEL: WWW. ELECTROSONIC.CO.ZA

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Altman Lighting Spectra Cyc 50 Specification

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

CONCRETE CONSOLIDATION

220KV EHV NETWORK AT RELIANCE JAMNAGAR REFINERY COMPLEX

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

TEST REPORT. ASTM E119-00a Fire Tests of Building Construction and Materials Modified* SMALL SCALE STEEL COLUMNS. Project No.

17" & 19" Color TFT LCD Monitor

There is much more behind

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

CNC872 Series CNC System Application for Cutting Machines

Linear flow controls VFC Linear flow controls with actuator IFC

Figure 1. High Efficiency T8 LED Tube. Figure 3. Full View of Light High Efficiency T8 LED Tube

LCD VALUE SERIES (32 inches)

RGB-3400-X RGB SEQUENCER / 3-CHANNEL UNIVERSAL LED DIMMER

Instruction Manual PT Series v1 PT 150

.Power Distribution Center. PD-1. Instruction Manual

Preliminary Data sheet

R xx-C0900-J074

Transcription:

AN OVERVIEW OF THE REAL SCALE TESTS IN THE FIPEC PROJECT (FIRE PERFORMANCE OF ELECTRICAL CABLES) Patrick Van Hees, SP - Swedish National Testing and Research Institute, Fire Technology, Sweden Hervé Breulet, ISSeP - Institut Scientifique de Service Public, Belgium Uberto Vercellotti, CESI Centro Elettrotecnico Sperimentale Italiano, Italy Stephen Grayson, Andrew Green, IC - Interscience Communications, United Kingdom ABSTRACT The FIPEC project is a research project funded by DG XII of the European Commission and co-financed by a large number of European cable manufacturers, cable material manufacturers, cable users and governmental research bodies. The FIPEC project has different levels of testing ranging from small scale to real scale. This article will discuss the real scale tests performed in the project. It explains the strategy behind the tests and gives an overview of the tests performed. The tests performed form a unique comparison of a number of horizontal and vertical test set-ups involving cables. Parameters such as heat sources, configuration, ventilation and loading were studied. In all tests the measurements were not limited to flame spread but heat release and smoke and toxic gas measurements were also taken. The outcome of this work was two set-ups, one horizontal and one vertical, which were used for the data base tests within the project. INTRODUCTION The FIPEC project 1,2,3 has the following objectives: Develop or modify fire test methods for electrical cables offering improvements on existing IEC test methods Develop or adapt the cone calorimeter test to use it for small scale testing of electrical cables. Develop a correlation model for the prediction of fire performance of electrical cables based on the results of small scale tests. Develop bases for a calculation model for the prediction of realistic fire performance of electrical cables, in some key constructions, based on the results of small scale tests on materials. Investigate the validity of models comparing the output from models with realistic design fire test data. The main core in this project is the performance of a number of real scale tests. The strategy and some of the results of these tests will be discussed in this paper.

TESTING APPROACH The WP 1 review in the FIPEC project determined the major scenarios for study to be Power plants, Vehicles (trains, ships and aircraft), and (e.g. underfloor voids, ceiling voids and riser shafts). Each scenario revealed specific characteristics that relate to configuration, type and amount of cable used. Within the FIPEC project, work package 1 investigated the main cable installation practices in Europe such as type of cable trays, type of cables, construction of cables, cable materials, loading levels and types of fixing, etc. In order to conduct the real-scale fire test it became clear that a number of steps had to be performed which will be explained in the following paragraphs. A number of scenarios were selected in WP 1. These included cable installations that were both vertically and horizontally orientated. A number of test configurations were selected which represent the scenarios envisaged. However each configuration cannot be used for all the cables and hence a selection of the most appropriate test configurations, for the real scale database within FIPEC, was necessary. This database will be used for the development of a full-scale test, development of a smallscale cable and material test and for modelling. A schematic overview of these different steps in the real scale test programme is given in figure 1 This article will only discuss the results of the first three steps. The data base tests will be reported later. Definition of real scale scenarios Definition of real scale test set ups Selection of real scale test set up for data base Data base tests Figure 1 Overview of the different steps in the real scale test programme OVERVIEW OF MAIN REAL SCALE TEST CONFIGURATIONS From the information given in the report of WP 1, a set of real scale test configurations can be identified which cover the scenarios mentioned above. First they can be divided into horizontal and vertical configurations. A further division is made based on whether or not there is thermal feedback from an adjacent surface (wall, floor, and ceiling). Hence three subdivisions can be made, namely open, semi-closed and closed. The closed configuration may be tested with or without ventilation. Finally it is necessary to investigate the void configuration i.e. a set up where the cables

are mounted inside a wall with very limited air access. This type of configuration is very specific and investigation of these scenarios may be limited, though it should be included. Figures 2 to 4 illustrate the selected test configurations. Table 1 shows how the real scale test configurations relate to the four key scenarios identified in WP1 of the FIPEC project. Figure 2 Overview of horizontal test configurations (side view) Figure 3 Overview of vertical test configurations (top view) Figure 4 Overview of the void test configuration (side and top view) Table 1 Overview of connection test configurations-scenarios Open Semi-closed Closed Closed with ventilation Void Horizontal Power plant Vehicles Power plant Power plant Vehicles Vehicles Vertical Power plant Power plant Power plant Vehicles

COMPARISON OF MAIN TEST CONFIGURATIONS During this test series the following orientations and configurations were tested. A rationale behind, and description of, the different configurations is given above. Open horizontal configuration Semi-closed horizontal configuration Closed horizontal configuration with one side wall partially closed Closed horizontal configuration without side walls (with and without ventilation) Open vertical configuration Semi-closed vertical configuration Closed vertical configuration (with and without ventilation) Vertical Void configuration Horizontal void configuration Three different tests were used in the open configuration to tune the heat source programme. The following heat source programmes were used: Heat source programme 1 1 minutes at 2 kw 1 minutes at 4 kw 1 minutes at kw 1 minutes at kw Heat source programme 2 1 minutes at kw 1 minutes at kw Heat source programme 3 5 minutes at 4 kw 1 minutes at kw 1 minutes at kw If flame spread, or sufficient heat release, was observed during a certain burner heat release level the heat release level was not increased to the next level. If the complete cable tray was burning the test was stopped by extinguishment. Four different cables were used for these tests with the following characteristics, code and loading: Cable A 95 mm 2 unarmoured 6 cables per tray with a distance of 2 cm between each cable Cable B 95 mm 2 armoured 6 cables per tray with a distance of 2 cm between each cable Cable C 7 1.5 mm 2 unarmoured 1 cables per tray with a distance of 2 cm between each cable Cable D 27 2.5 mm 2 unarmoured 7 cables per tray with a distance of 2 cm between each cable All the cables used have had their fire performance enhanced by the addition of flame retardants and fillers. Not all cables could be tested in all combinations but the actual tests performed are shown in table 2. The voids were constructed as closed cable trays, i.e. with steel locks.

Table 2 Overview Of Tests Performed Test number. Heat source number Orientation Configuration Ventilation Trays Cables 1 1 Horizontal open Natural 3 A 2 2 Horizontal open Natural 3 A 3 3 Horizontal open Natural 3 A 4, 5, 6 3 Horizontal semi closed Natural 3 A, C, D 7 3 Horizontal side wall closed closed Natural 3 A 8, 9, 1, 11 3 Horizontal no side walls closed Natural 3 A, B, C, D 12 3 Horizontal no side walls closed Forced.8 m/s 3 B 13 3 Vertical open Natural 2 B 14, 15, 16, 17 3 Vertical semi closed Natural 1 A, B, C, D 18 3 Vertical closed Natural 1 B 19, 2 3 Vertical closed Forced.6m/s and 1 m/s 1 B 21 2 kw IEC burner Void horizontal closed Natural 1. C 22 2 kw IEC burner Void vertical closed Natural not appr. C

RESULTS AND DISCUSSION OF HORIZONTAL SCENARIOS Comparison of the heat source programme in horizontal scenario The heat release rate curves for one cable (Cable A) tested with three different heat sources in an open horizontal scenario are shown in figure 5. It can be seen that a 2 kw heat source causes little effect, and that even a 4 kw heat source causes only limited heat release rate from the cables. Incident heat levels of at least kw, and especially and kw are needed to obtain a significant measurable heat release rate contribution from the cables. The cable contribution to the heat release rate at the kw input level is identical for heat source programmes 2 and 3. This means that the 5 minutes preheating period at 4 kw in heat source programme 3 only had a minor effect. However, it is important to note that: (a) no flame spread was observed with cable A, even at heat input levels up to kw and (b) after a short period of HRR increase, the HRR decreased again and returned towards the heat release level of the heat source. Considering these points, heat source programme 3 was chosen for the other tests, in order to observe at which heat source levels flame spread would occur. The strategies explained above (relating to the increase to the next heat release level and the specimen extinguishment) were applied for all remaining tests. Hence some tests were stopped before the end time. 6 Open Horizontal Scenario Cable A Heat source programme 1: 2-4-- kw Heat source programme 2: - kw Heat source programme 3: 4-- kw 1 2 3 4 5 6 Figure 5 Comparison of different heat source in the open horizontal scenario

Comparison of different horizontal configurations without ventilation Comparison horizontal scenario Cable A open semi closed 5 1 15 2 25 3 35 Figure 6 Comparison of open and semi closed horizontal scenarios for cable A 7 6 Comparison horizontal scenario Cable A Closed with side wall Closed without side wall 5 1 15 2 25 3 Figure 7 Comparison of closed horizontal scenarios for cable A It is clear from Figure 6 that the semi closed configuration generates more heat release than the open configuration. Furthermore, it can be seen in Figure 7 that the closed configuration shows clear evidence of flame spread for Cable A at the kw input level (i.e. at 15 minutes). The vertical side wall causes initiation of the flame spread to be delayed. This could be seen during the test, since the upper cable tray did not ignite as fast, probably due to a lack of oxygen in the corner where the walls and ceiling meet. Once the kw level is reached both closed configurations produce very similar results.

6 Comparison horizontal scenario cable C Cable C semi closed Cable C closed 5 1 15 2 25 3 Figure 8 Comparison of horizontal scenarios for cable C 7 6 Comparison horizontal scenario cable D Cable D semi closed Cable D closed 5 1 15 2 25 3 35 Figure 9 Comparison of horizontal scenarios for cable D Test results on Cables C and D, in Figure 8 and Figure 9, show similar trends. Clearly, the closed scenario is more severe than the open one and leads to flame spread for these cables, as it had done for Cable A. In the case of these cables (C and D), there is no evidence of either flame spread or substantial heat contribution at the kw level.

Comparison of different horizontal configurations with ventilation 8 7 6 Horizontal scenario ventilation effect Cable B Closed m/s Closed.8 m/s 5 1 15 2 25 3 Figure 1 Comparison of closed horizontal scenarios for cable B The effect of forced ventilation in the closed horizontal scenario was investigated with Cable B. It is clear from Figure 1 that increased ventilation results in increasing flame spread, but only at the kw level. At the kw level the non-ventilated test is a lot more severe. Note also that the test with no forced ventilation ( m/s) was stopped after 15 minutes, while the test with forced ventilation (.8 m/s) was also stopped before the end, after the fire was extinguished. Comparison of cables in the different horizontal configurations Comparison cables semi closed horizontal scenario Cable A Cable C Cable D 5 1 15 2 25 3 35 Figure 11 Comparison of cables in the semi closed horizontal scenario Test results for three different cables, in the semi closed horizontal scenario, are shown in Figure 11. Cables C and D generate very similar results, and out-perform cable A, which spreads flame significantly faster. This scenario is likely to be inadequate for distinguishing the fire performance of cables.

7 6 Comparison cables horizontal closed Cable A Cable B Cable C Cable D 5 1 15 2 25 3 Figure 12 Comparison of cables in the closed horizontal scenario The test results for all four cables in the closed horizontal scenario are shown in Figure 12. Clearly, the flame spread from Cable B is the fastest, followed by Cable A. Cables C and D perform similarly to one another at the kw, but they can be differentiated, albeit not by much, at the kw level, where cable D has more flame spread. In consequence, this closed scenario is adequate for generating distinctions between the cables. VERTICAL SCENARIOS Comparison of different vertical configurations without ventilation Comparison vertical scenario Cable B Vertical open Vertical semi-closed Vertical closed 5 1 15 2 25 3 35 Figure 13 Comparison of vertical scenarios for cable B Three vertical scenarios were investigated with one of the cables, Cable B, and the results are shown in Figure 13. The cable chosen was the one with the poorest fire performance in the closed horizontal scenario (see Figure 12). It can be seen that no flame spread occurs in this vertical scenario, unless there is, at least, a corner situation. It should be noted that the heat source was only increased to kw in the open vertical situation. In fact, in the semi closed vertical situation (corner situation), and in the vertical closed situation, flame spread was observed at the kw level, and further heat input

was not necessary. It is interesting to observe that: (a) the heat released levelled out in the closed configuration once the whole tray was burning and (b) the fire is ventilation-controlled due to the closed set up. In the first test (open configuration) two parallel cable trays were mounted, but no lateral flame spread was observed. Hence it was decided to use only one vertical cable tray for all remaining tests to avoid excessive use of cables. Comparison of cables in the vertical closed configuration with ventilation 35 Vertical scenario ventilation effect Cable B Closed m/s Closed.6 m/s Closed 1 m/s 25 15 5 5 1 15 2 25 3 Figure 14 Comparison of vertical closed scenarios with ventilation for cable B The effect of forced ventilation was studied in the vertical closed scenario with Cable B, and the results are shown in Figure 14. It can be observed that increasing the ventilation to higher airflow rates does not have large effects on flame spread in this set up. This can mainly be explained by the fact that the area where the cables have not yet ignited is cooled by the increased air flow and that the smoke gases are also cooled by the larger amount of incoming air. In fact, installation of cables in forced ventilation shafts is rare in Europe; thus, no more studies will be performed in this project with respect to ventilation. A complete study of the effect of ventilation would be very extensive and is not the main goal of this project. Comparison of cables in the different vertical configurations 35 25 15 5 Comparison cables in semi closed vertical scenario Cable B Cable A Cable C Cable D 5 1 15 2 25 3 35 time[m in] Figure 15 Comparison of cables in the semi closed vertical scenariio

Tests with all four cables in the semi closed vertical configuration are shown in Figure 15. It is clear that the behaviour of the various cables differs. Cables A and C spread flames first, followed by Cable B and finally by Cable D. All four cables showed a clear flame spread at the kw heat input level, which means that this scenario is more severe than the horizontal scenario. It can also be seen that the semi closed or corner configuration is already capable of distinguishing between the fire performances of the different cables. RESULTS AND DISCUSSION OF VOID SCENARIOS In the void scenarios it was seen that a vertical void is definitely more severe than a horizontal void. A heat source similar to the IEC 6332-3 test produces a continuous flame spread on cable C. which can be considered as a high performance cable. Although only two tests were conducted it is clear that some consideration should be given to a vertical void scenario, where re-radiation and chimney effects play very important roles. Although it was not foreseen in the project, it is suggested to run a limited number of cables in a vertical void scenario. The results of the vertical void scenario are given in Figure 16. The length of the cable was limited to 1 m, but even at such a short length a HRR of kw is already observed. The results of the horizontal void scenario are not given since no real heat release contribution from the cable was observed. 12 Vertical void scenario cable C 8 HRR(kW) 6 4 2 Figure 16 Vertical void scenario 5 1 15 2 25 3 35 4 Time (min) CONCLUSIONS: CHOICE OF TEST CONFIGURATIONS AND STATUS OF PROJECT Horizontal test configuration Considering all the results and discussions reported above, the most efficient horizontal test set up was chosen to be: Closed horizontal configuration with no side walls No ventilation Heat source programme 3 (4-- kw) Three cable trays installed with mounting of cables with half a cable diameter distance between the cables but with a maximum of 2 cm

The closed scenario, with no forced ventilation, is necessary in order to distinguish between the cables in the database. Cable mounting in highly ventilated areas is uncommon in Europe; thus, a nonventilated scenario was chosen. A stepwise heat source programme will allow distinctions to be made between different cable groups that may appear similar at a single heat source level. Horizontal scenarios are less severe than vertical ones (both the literature and the tests performed show that), therefore only a limited number of cables in the database were tested horizontally. Vertical test set up Considering all the results and discussions reported above, the most efficient vertical test set up was chosen to be: Semi closed vertical configuration (corner situation) No ventilation Heat source programme 3 (4-- kw) One cable tray installed with mounting of cables with half a cable diameter distance between the cables but with a maximum of 2 cm The semi closed, non-ventilated scenario has been chosen here, since this scenario can already distinguish between the cables in the database. A completely closed vertical scenario could limit both the observations and the use of fully ventilated conditions. The purpose of these real scale tests is also to investigate the real scale fire behaviour of cables; hence it is advisable to avoid very underventilated conditions. A well ventilated set up will permit the use of the data as input to smoke and fire spread models, of both the zone and field type, which can address the under ventilated situation. A non-ventilated scenario was chosen, since most cables are not mounted in highly ventilated areas. A stepwise heat source programme will allow distinctions to be made between different cable groups that may appear similar at a single heat source level. The vertical scenario is considered more severe than the horizontal and the majority of the cables selected for the project were tested in this scenario. Status of project In total 46 data base tests were conducted. 1 of the selected cables were tested in the horizontal configuration and 36 were tested in the vertical configuration. During all these tests additional FTIR measurements have been performed. Currently, the large amount of data is being processed and evaluated. A large scale test procedure based on IEC 6332-3 has been developed using HRR and SPR (smoke production rate) measurements A cone calorimeter test procedure is developed for cables and materials. ACKNOWLEDGEMENT The authors would like to thank all sponsors of the project for co-financing of the project. REFERENCES 1 P. Van Hees, S. Grayson et al, An overview of the FIPEC project, Proceedings of Flame Retardants Conference, London 1998. 2 P. Van Hees, S. Grayson et al, An overview of the FIPEC project, Proceedings of Plastics in Telecommunications Conference, London 1998. 3 P. Van Hees, S. Grayson et al, An update of the FIPEC project, Proceedings of Fire and Materials Conference, San Antonio 1999.