CASS TL-3 (Utilizing C-Shaped Post) Maintenance and Repair Manual

Similar documents
K Service Source. Apple High-Res Monochrome Monitor

Caution. Hanging the Screen:

K Service Source. Apple High-Res Monochrome Monitor

2178-L/S Series Fiber Optic Splice Case with Gasket

ASSEMBLY AND INSTALLATION 3 ELEMENT 6 METER BEAM

Aerial Cable Installation Best Practices

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

Installation Manual Original Instructions - IW4001

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

A CENTIMETER FM YAGI ANTENNA MHz

Replacing the PanelMate epro PS, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-12 Series Backlight Assembly

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Winch Adjustable Feed Level Tubes for the Adult Turkey Feeder Installation & Operator s Instruction Manual MF /99

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

High Performance DL-60 (Gold Plus) (7 in - 13 in) Dual Lane Spliceable Tape Feeder Part Number: Revision 3 Sep No.

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

S-503, S-570, SX15-45 and SX15-45M 45 OHM TALKBACK SPEAKERS

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

HCS - HES Cabling Systems

INSTALLATION INSTRUCTIONS FOR

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

Public Works Division Lighting District Fiber Optic Specifications April 2009

3 SLiC Aerial Closure with Rubber End Seal

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

Support Frame STB Technical Instruction Manual

3M Distribution Box (DDB)

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

VITALink Taped Splice Straight Through Crimp

GENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS. 1. DESCRIPTION: Satellite Radio System 2. APPLICATION: Frontier (2006~)

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

DLP ANTENNA INSTRUCTION MANUAL. Dielectric LLC 22 Tower Road Raymond, Maine Phone:

AS-300D Series Smart Bench Scales Owner s Manual

LGX Compatible (LSX) Connector Module) User Manual)

Electric Motorized Projection Screen PowerMax Tension Series

CHAPTER 14 WIRING SIGNALS AND LIGHTING FIELD GUIDE Wiring Requirements WIRING

3M Better Buried Closures

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

Channel Cable Tray - Accessories

1-Touch Vibratory Sieve Shaker SS-10

MARINE HORNS V-1030M - 5 WATT PAGING HORN AMPLIFIER ASSEMBLY V-1036M - 15 WATT PAGING HORN AMPLIFIER ASSEMBLY V-1048M - 45 OHM TALKBACK HORN

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS (440)

3M Better Buried Compound Compression Closure System

Installation Guide OvalSox TM Cable

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

3M Fiber Optic Wall Mount Enclosure 8430 Series

OPERATOR S ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL

INSTRUCTION MANUAL. Model V-4R Collinear Gain Vertical for MHz. General SPECIFICATIONS

UltraTwist. Product Description. Instruction Guide

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

TracVision 95W LNB Installation

GENUINE PARTS. SIRIUS Under Glass Antenna Kit

A7 Owner's Manual ii

Kramer Electronics, Ltd.

INSTALLATION INSTRUCTIONS

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

Installation instructions, accessories. Subwoofer. Volvo Car Corporation Gothenburg, Sweden. Page 1 / 29

Replacing the PanelMate epro PS, PanelMate epro PS Classic, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-15xx Series Backlight Assembly

1.8 METER SERIES 1183 Az/El MOUNT ANTENNA SYSTEM

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

EZ-LIGHT S18L Color General-Purpose Indicators

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

8mm PrecisionPro (Green) DL Spliceable 7-13 Tape Feeder. T Rev. B hd This document supports assembly Rev. -

IP-LINX Fiber :: X-XXXX

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

WARNING VGTWC VGF-1. Model No. Galvanized Steel Thimble and Wire Rope Cable Termination Kit

ASSEMBLY & INSTALLATION XM Meter Monoband Yagi MHz (10/98)

Quick-disconnect cables. Adjustable mounting brackets

3M 8900 Single-mode SC Crimplok Connector

3.8M C-BAND Rx/Tx ANTENNA SYSTEM

OCT 15 Rev B

INSTALLATION GUIDE. Axle Weighing Truck Scale. 60,000 lb x 20 lb Factory Calibrated Includes Pre-interfaced Wireless Remote LED Scoreboard Displays

apple Service Source Apple Cinema HD Display 23" LCD (ADC) 11 April Apple Computer, Inc. All rights reserved.

LED-PAR200B USER MANUAL. COLORsplash 200B


1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

Linear Array with Intensity Adjustment

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

DS1 Cross-Aisle Panel

Electric Wall/Ceiling Projection Screen Saker Tab-Tension Series User s Guide

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

Quick Installation Guide. Indoor / Outdoor Antenna, Antenna Cable & Surge Arrestor

apple Service Source Apple Studio Display 17" LCD (ADC) Updated 6 Decenber Apple Computer, Inc. All rights reserved.

2.4 METER SERIES 1250 ANTENNA SYSTEM

Theatrik HUSH PAR. Blizzard Lighting, LLC Waukesha, WI USA Copyright (c) 2013

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

Installation Manual for New or Retrofit Installations

Installation Note. Option GHz Operation Upgrade Kit. For 8753E and 8753ES Network Analyzers. Applicable Upgrade Kit Model Number

Transcription:

CASS TL-3 (Utilizing C-Shaped Post) Maintenance and Repair Manual Part No. 620290B Revision March 2007

INDEX Page Introduction 3 General CASS TM Maintenance 3 Pre-stretched Cable 3 Non Pre-stretched Cable 3 Repair 3 Repair for System Impact (CCT Not Damaged) 4 Repair for a CCT Impact 4 Repair for Cable Transition to W-Beam (CTW) Impact or Rail Element(s) 5 Emergency Repair 6 Road Blocked Due To a Accident 6 Removing Entangled Cable from a Vehicle 6 Repairing Cut or Damaged Cable 7 CASS TM Temperature and Tension Chart 9

INTRODUCTION The amount of general CASS TM maintenance is based on the cable being prestretched or standard. The amount of repair after an impact is based on the severity of the impact and the cable being pre-stretched or standard. If an agency allows both pre-stretched and standard cable, it is important that they know what cable has been supplied for each installation. The appropriate CASS TM or CASS-TL3 TM & CASSTL4 TM Installation Manual should be used in conjunction with these instructions. When performing any of the following activities, please observe all safety regulations. GENERAL CASS TM MAINTENANCE PRE-STRETCHED CABLE For pre-stretched cable, the cable tension should be checked at least once a year. The tension value is established based on the air temperature or cable temperature. See the CASS TM Temperature and Tension Chart for the tension values. STANDARD CABLE For standard cable, the cable tension should be checked at least twice a year. The tension value is established based on the air temperature or cable temperature. See the CASS TM Temperature and Tension Chart for the tension values. REPAIRS After an impact, the system will require some repair. Under most impacts, the cable will still maintain its original height and may be able to withstand additional hits. Even with this capability, it is recommended that the system be repaired as soon as possible. Because of the ease of repair, most impacts can be repaired in a short period of time. An impact that encounters a CASS TM Cable Terminal (CCT) may require the retensioning of the entire run of cable. After repairing the cable, the tension throughout the system should be checked. 2

It is recommended that for impacts with vehicles larger than those used in the NCHRP Test Level 3 or Test Level 4 tests, the cable should be checked to determine if it needs to be re-tensioned. REPAIR FOR SYSTEM IMPACT (CCT NOT DAMAGED) If an impact occurs and the CCT is not involved, usually only the posts will have to be replaced and the cables re-inserted in the posts. The following steps should be followed in making this repair: 1. Inspect the damaged system to determine whether the CCT has been affected. If it is determined that the CCT has not been affected, continue with the following steps. If it has been affected, then refer to the Repair for CCT Impacts Section. 2. Inspect the damaged system and determine what material will be required to make the repairs. 3. Remove the damaged posts. They should come out of the sockets easily. If the posts are driven, then they will have to be pulled out of the ground. 4. Install new posts in place of damaged ones. The C-channel posts shall be installed with every other post being rotated 180 degrees (See Figure 1). Figure 1 Post Orientation 5. The bottom cable is then placed in the post slot. 6. The appropriate CASS TM, CASS-TL3 TM or CASS-TL4 TM spacer is placed above the bottom cable. 7. The middle cable is then placed in the post slot. 8. The appropriate CASS TM, CASS-TL3 TM or CASS-TL4 TM spacer is placed above the middle cable. The stainless steel strap is also placed on the post above the middle cable. 9. The top cable is then placed in the post slot. 10. If the post caps are used, they should be placed on the posts. 11. Depending on the severity of the impact, after the repair, the cable might have to be re-tensioned. If the cable is standard and has been installed less than 2 years, the tension on the cable should be checked. If the 3

tension has to be adjusted, this can be done by adjusting the turnbuckles at each end of the impacted cable section to the recommended values in the CASS TM Temperature and Tension Chart. Note: The reflective sheeting may be placed on the post caps or the spacers for the CASS TM system and on the CASS-TL3 TM and the CASS- TL4 TM spacers based on the agency s specification. REPAIR FOR CCT IMPACT When the cable has been impacted and the CCT is involved, the following steps should be followed: 1. Steps 1 through 9 for the Cable Repair for non CCT Impact should be followed. 2. Disconnect the CCT cables from the line cables. Before disconnecting cables, mark the location of the turnbuckles and CCT nuts on the fittings. The damaged CCT line posts need to be removed and replaced. 3. The top of the Controlled Release Posts (CRP) should be re-installed to the stub CRP posts. 4. The cables should be installed per the installation manual. The nuts installed on the fittings should be located on the mark made before removing them. 5. The CCT cables and line cables can be connected by the use of a backhoe or other mechanical means. The turnbuckle should be turned to the marks before they were disconnected. The cable should be checked with the tension meter and adjustments made to bring it to the correct tension. If the correct tension cannot be obtained with the turnbuckles, the line cable will have to be re-measured, cut, and reattached per the installation manual(s). Repair for Cable Transition to W-beam (CTW) or Rail Element(s) When an impact occurs with the transition to W-beam, there will be damage to the cable post and there could be damage to the W-beam or W-beam posts. If only the cable posts have been damaged, the procedures presented earlier on cable repair should be followed. If the guardrail posts are the only damage to the guardrail system, then the post should be replaced by normal guardrail repair procedures. If the W-beam transition rail elements or other guardrail elements in the vicinity of the transition 4

are damaged, one of the following options should be taken to repair the rail elements: Option 1 (Cable Tension not Released) 1. If guardrail panel(s) other than the W-beam transition rail panels is the ones that need to be replaced, the panel(s) can be replaced without releasing the cable tension. 2. Before the rail splice bolts are removed, the guardrail system needs to be secured to prevent the post from leaning over when the panel(s) is removed. This is done by the use of a chain or come-along. 3. Once the posts are secured, the rail panel(s) can be removed and replaced. 4. After the rail panels are replaced, the method of securing the spacing can be removed. Option 2 (Cable Tension Released) 1. When the W-beam transition rail elements need to be replaced, the cable tension will need to be released. Before releasing the tension, place a mark on the fittings at the end of the turnbuckles and end of the CTW nuts. 2. Release the tension on the cables and remove the cable from the anchor brackets. 3. Replace the rail panels and posts as needed. 4. Reinstall the cables in the anchor brackets and reinstall the nuts. The nuts installed on the fittings should be located on the mark made before removing them. 5. The CCT cables and line cables can be connected by the use of a backhoe or other mechanical means. Normally the cables do not have to be re-cut, just re-connected. The turnbuckle should be turned to the marks before they were disconnected. The cable should be checked with the tension meter and adjustments made to bring it to the correct tension. EMERGENCY REPAIR There could be an occasion when an accident could cause significant traffic congestion, or the cable can be entangled with the vehicle. The following are some suggestions on what to do to get traffic moving or the cable untangled. ROAD BLOCKED DUE TO AN ACCIDENT To resume traffic flow after an accident, or to get emergency vehicle(s) access to the accident site, crossover access through the cable may be necessary. To 5

provide this access, remove cables from several posts upstream and downstream of the desired opening. Opening width can be adjusted by removing posts from the ground sleeves. The cable can be held down and the traffic or emergency vehicle(s) can pass over it. In life threatening or emergency situations, the cable can be cut. If the cable was put under additional tension due to the accident, the tension should be reduced at the nearest turnbuckles to the impact. The cable should be cut at a location midway between two posts. To reduce the amount of cable damage during cutting, duct tape should be wrapped around the cable on each side near where the cable will be cut. Even though the cable should move only a short distance in each direction, caution should be used when cutting the cable. REMOVING ENTANGLED CABLE FROM VEHICLE There may be an occasion when the cable gets entangled with a vehicle and needs to be removed before the vehicle can be towed away. Methods described above are a few ways of removing the cable. Another option may be to lift one or more of the cables up over the vehicle. During this operation, if any of the line posts entangled with the cable start to lift up out of the sleeves, the lifting should be stopped and the post(s) removed from the cable. Once the post(s) are removed, the cable can be lifted up over the vehicle. REPAIR OF A CUT OR DAMAGED CABLE Below are several methods to repair a cable that has been cut or damaged. Splicing of the cable may be necessary if a cable is cut, or in a rare case, it is damaged during an impact. An appropriate length of cable (50 feet or longer) to make the splice should be obtained. The end of the cut cable should have the ends re-cut so as to provide a clean/smooth end. Because the cable was cut and the tension removed from the system, the cable will have to be re-tensioned. If an accurate length of cable is used for the splice section, this could reduce the effort it will take to re-tension. Two cable splice connectors will be required to connect the cables together. One end of the splice cable is connected to one end of the cut cable with a connector. Another connector is applied to the other end of the splice cable and the end of the cut cable. This cable splice connector is assembled and this is done by the use of a backhoe or other mechanical means. The tension on the cable should be checked with the tension meter and adjustments made at the turnbuckles to bring cable to the correct tension based on the ambient air temperature or the cable temperature and the values on the CASS TM Temperature and Tension Chart. If the cable splice has been cut accurately, the tension may be obtained by turning the turnbuckles at each side of the cut. 6

If the tension cannot be obtained at the turnbuckles at each side of the splice, it may be necessary to re-tension the cable at the end of the cable run. This would be done at the end where the field splice was made. The field splice should be removed and the cable measured, cut, and re-connected with the correct tension. Follow the procedures in the installation manual when doing the re-tensioning. Some installations may have field splices at all locations. If this is the case, then the measuring, cutting and re-connecting can be done at any location. A second method to reconnect the cables is to use a 5 foot section of cable with factory applied fittings on each end. This method will also require two (2) turnbuckles and a left-hand and right-hand threaded fitting to complete the connection. About 9 8 of cable should be removed from the cut cable. The removal of this amount of cable should allow the system to be re-tensioned with the two (2) turnbuckles inserted into the system. The threaded fittings should be installed and the cable ends connected per the installation manual. In lieu of the 5 foot section of cable, a short piece of cable can be used but a lefthand and right-hand threaded fitting will have to be applied to the cable. When using a cable length other than 5 feet, the amount of cable removed from the cut cable should be adjusted based on the cable length removed. If the length of cable use is less than 5 feet, then less than 9 8 of cable should be removed from the cut cable. If more than 5 feet of cable is used, then more than 9 8 of cable should be removed from the cut cable. To help to determine the amount of cable to be removed, after the threaded fittings are installed on the piece of splice cable, take a measurement from end of fitting to end of fitting. Take this measurement and add 4 6 and this will be the amount of cable to be removed from the cut cable. If the damaged cable after cutting is less than a total of 4 6, the connection can be made with a left and right threaded fitting and a turnbuckle. Remove 4 6 of cable from the cable run. Place a left-hand threaded fitting on one end of the cut cable and a right-hand threaded fitting on the other end of the cut cable. Follow the procedures in the installation manual for connecting the two ends using the turnbuckle. 7

CASS TM TEMPERATURE AND TENSION CHART (FOR CASS TM, CASS TM -TL3 AND CASS TM -TL4) o F Pre-Stretched Cable Tension (lbs)* o F Standard Cable Tension (lbs)* -15 7500-15 8800-10 7300-10 8600-5 7100-5 8400 0 7000 0 8200 5 6800 5 8000 10 6600 10 7800 15 6500 15 7600 20 6300 20 7400 25 6100 25 7200 30 6000 30 7000 35 5800 35 6800 40 5600 40 6600 45 5500 45 6400 50 5300 50 6200 55 5100 55 6000 60 5000 60 5800 65 4800 65 5600 70 4600 70 5400 75 4500 75 5200 80 4300 80 5000 85 4100 85 4800 90 4000 90 4600 95 3800 95 4400 100 3600 100 4200 105 3500 105 4000 110 3300 110 3800 115 3100 115 3600 120 3000 120 3400 125 2800 125 3200 130 2700 130 3000 135 2600 135 2900 140 2500 140 2700 145 2400 145 2500 150 2300 150 2400 160 2100 160 2200 170 1900 170 2000 180 1700 180 1800 190 1500 190 1600 200 1300 200 1400 * Tolerance: 200 to +200 pounds 8

2525 Stemmons Freeway Dallas, Texas 75207 888-323-6374 (USA only) 214-589-8140 (Outside USA) www.energyabsorption.com www.highwayguardrail.com