Contact Julianastraat 46, 4301 NC, Zierikzee (NL) +31 (0) (Monday-Friday 13:00-17:00h)

Similar documents
technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam

SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS

mainstage or theatercafe, on demand on demand 103 dba at FOH 6x4x1 meter (if needed bigger) + stairs Max. 4x drumriser (2x1x0,5 meter) No Yes

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018!

VENUE SPECS Channel Music GmbH. 2 Floor Plan. Falckensteinstr Black Room Berlin. 8 Blue Room. 12 Venue Info

Theatre Technical Specifications

Les Docks / Av. de Sévelin Lausanne. Technical Rider

TECHNICAL SPECIFICATION

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15

SHOWBOX SODO TECHNICAL SPECIFICATIONS

YAAM Berlin Venue Specifications & Technical Rider. Effective April 2018 Availability, errors and specifications subject to change without notice!

Pioneer set monitor 1 1x DJM 900 nexus 2x CDJ 2000 nexus 2x QSC K12 monitor speaker

Ed Blackwell Production Manager Mike Weller Head of Music

Main Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

Small Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

Technical Data Sheet

Analog General Information West End Ave. Nashville, TN, Time Zone: CST

Technical Services and Specification

Les Docks / Av. de Sévelin Lausanne. Technical Rider. Technical Rider Docks, updated

TECHNICAL SPECIFICATIONS

Access to back stage is off Fletcher St on the eastern side of the building

Matt Dann Cultural Centre

LOAD IN / LOAD OUT CARS / SPLITTER VAN / NIGHTLINER THROUGH MAIN ENTRANCE SITUATED AT AUGUSTE ORTSSTRAAT 20-28, 1000 BRUSSEL.

Barbican Concert Hall Sound System Spec

Treefort Music Fest- March Festival Information Main Stage

Main House Technical Specification

THEATRE EQUIPMENT DECEMBER 2017

Technical Specification for the Alley Theatre, Strabane

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Technical Specification Pavilion Dance

TECHNICAL SPECS SECOND HALL PATRONAAT

CENTRE FOR PERFORMING ARTS

TECH SHEET AND INFORMATION (Updated )

AUDIO SPEAKERS / AMPLIFICATION

Dr JOHN GALLAGHER CONCERT CHAMBER

Contact. Directions. Stichting Studio301 Overtoom HW Amsterdam The Netherlands.

Project manager (PM): Pamela Næss Mail: Phone:

Tickets will be sold through our ABC account and all tickets are scannable on entry.

Get Funked Compact 6-piece. Technical Rider 2017/18. Contents Page 1/2 Technical Rider Page 3 Channel List Page 4 Monitor List Page 5 Stage Diagram

Technical Information

Dinkelspiel Auditorium - Technical Specifications

HORACE X PERFORMANCE REQUIREMENTS (Technical)

SPECIAL EVENTS Hollywood Boulevard Los Angeles, CA

TECHNICAL REQUIREMENTS

Complete guide Compiled January 2014

RIDER 2018 version 1 English

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

Monty Kultuurfaktorij Technical Rider

The only advanced setup requirement is layout of chairs and tables in required configuration

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Main House Technical Specifications

Section A: Front of House (FOH) Public Address (PA) Speaker System

CARGO PRODUCTION GUIDE 2016

TECHNICAL SPECIFICATIONS 2018!

Production Advance Information

Rooming List. Catering & Meals. 10 Hands and 1 Piano TIMELINE SHOW WITH GUEST Tech Sheet

Technical Director of Production Andrew Quick Ext 252

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Venue Advance Information

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK

Technical Specifications

Technical Specifications for the Rival Theatre 2018

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

GENERAL INFORMATION CONTACT DETAILS. Venue Booker: Shaun Adams E: P: (03)

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

The Lexington VENUE SPEC. The Lexington Live music venue and whisky lounge. Version 2.5 Updated January 2015

Technical Pack. Attenborough Arts Centre

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring Zach Vander Missen Muhammad Farooq Garrett McMindes

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

2017 TECHNICAL SPECIFICATIONS

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Technical Specifications and Inventory Spring 2018

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

TECHNICAL SPECIFICATIONS LEPERCQ

AKI STUDIO THEATRE Information and Technical Specifications

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Technical Specifications Updated 01/10/2017. Stage

WE RE BACK CONCERT PACK UNSWROUNDHOUSE.COM

111 North 5 th Street Minneapolis, MN 55403

National Folk Festival PA Specs 2018 MARQUEE

THE CLASSIC GRAND 18 JAMAICA STREET GLASGOW G1 4QD

HIRE AND TECHNICAL INFORMATION

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

THE STREET THEATRE. Technical Specifications

BLACK VIOLIN. Hospitality Requirements. One large master or star dressing room equipped as follows:

UNIVERSITY CONCERT HALL. Technical Specification

TECHNICAL SPECIFICATION

Visy Theatre technical information and general specifications 2019

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

* The Wedding Ceremony & Reception Bundle discount is priced and offered for Bookings at Lakeview Banquet Center only.

Liteup Events Equipment Brochure 2016

US 2015/16 TECH RIDER

A red velvet front of house curtain closes off the main stage leaving only the apron visible to the audience.

Camden Opera House Theater. Technical Information

Transcription:

19-03-2017 Technical specs Contact Address: Phone: Email: Website: Julianastraat 46, 4301 NC, Zierikzee (NL) +31 (0)111 450 127 (Monday-Friday 13:00-17:00h) info@brogum.nl www.brogum.nl Hall specifications Capacity (hall): regular evenings max. 200 pers. ( spec. events max. 400 pers.) Audience (d*w, area): 13.37 * 9.12 m, 106m² Stage (h*d*w, area): 0.8 * 5.00 * 9.00 m, 46m² Drum Riser (h*d*w): 0.4 * 2.00 * 3.00 m Backstage specifications (Un)loading Area (d*w) 2.8m * 4,0m Backstage 1 (d*w) 2.8m * 4.0m + toilet, sink Backstage 2 (d*w) 2.8m * 4.0m + toilet, shower, sink Outdoor PR (on request): Banner size (h*w): Poster boards (2pcs): 1.0m * 3.0m (landscape) A1 (portrait) Julianastraat 46, 4301 NC, Zierikzee, +31 (0) 111 450 127 1

Additional information -When arriving please park your car in a parking zone located at the rear side of the building. The (un)loading area blocks access to the main entrance and serves as a backstage emergency exit as well. So please when (un)loading occupy this area as short as possible. -All backstage doors (including double stage doors) must be kept closed during sound check and show time. -The venue has a smoking restriction in all areas, only outside the building smoking is allowed. -Bottled drinks and hard liquor are prohibited in public areas. Please keep them backstage. -Each backstage room has its own, fridge, table & chairs. Please keep this place clean & tidy. Important! Sound levels are limited! Respect our neighbors! Audio specifications 97 dba (L Ar,LT ) General purpose Audio system (Stage R): Limiter: Dateq SPL2 (trip point @ 0dB!) Amp: JBsystems C3-1800 2x 450W (2ch mode) Speakers: 4x JBL JRX115 15 500W Mixer: DAP Audio 4.1, 4ch line/mic+ eq +phantom Crossover: Amp Subs: Subs: Behringer Super X-Pro crossover (low cutoff 32Hz - SUB - 120Hz MIDHIGH) SA900B 2x 425W 4x 15 back loaded scoop 500W General purpose Audio equipment (Bar): Ethernet: Level One FSW1621, 16ports fast Ethernet switch Mixer: DAP Audio Compact 8.1, 8ch line/mic +phantom Mics: Omnitronik UHF500, 2x wireless microphone Radio: Sony ST-SE370 CD player: Omnitronik CDP462, dual cd player. Laptop input: stereo 3,5mm jack Ext. input: stereo RCA Video: (fixed position in hall, for promotion purposes only) Beamer: TV Screen: Benq HD1024p, VGA/HDMI. Panasonic 42 Full HD Plasma Julianastraat 46, 4301 NC, Zierikzee, +31 (0) 111 450 127 2

Front of House (Auditorium) System One Audio Focus 2 configuration TOP (L+R) SUB (L+R) SUB (Centre) System One Audio D-TOP3 System One Audio D-SUB1 3X Hofman Audio B115 FOH mix (Digital Digico D5) Mixer Digico D5 Live (NO SD!) Stage rack Digico MaDi (48 in / 40 out ) USB int Digico UB MaDi Monitors: Drum fill: 4* System One Audio D-MON12 1* Hofman B115 + 1* Hofman T112 Microphones & DI (other types, on request only) Voice wireless Instrument Instrument Bass Kick Snare/ toms Overheads Direct inputs Extra: 5* SM 58 Shure (Dynamic) 2* GLXD24E/SM58 Shure (Dynamic Wireless digital) 2* SM 57 Shure (Dynamic) 1* SM 57 Beta Shure (Dynamic) 1* MB-6K Audio Technica (Condensor) 1* ATM250 Audio Technica (Condensor) 5* MB-5K Audio Technica (Dynamic) 3* SE300B/CK91 AKG (Condenser) 7* LBB-100 Klark Teknik Active DI 2*SM57B 3*MD421 1*D112 Mic stand low Mic stand normal Mic stand overhead 4* K&M 10* K&M 2* K&M DJ SET: (Rental items, on request only) Mixer Players Turntables 1* DJM-900 NXS2 2* CDJ 2000 NXS2 2* Pioneer SL1000 Audio Power outlets (stage right) 1* 400V 32A CEE (MK/K1 3x25A) 6* CEE 16A 3pol Audio Power outlet for Backline/ monitors 6* Cable assembly CEE16A 3pol => 4x Schuko 1x Powercon General purpose power outlet (stage Right): 4* 230V 16A Shuko (OV1/G9,G10) Julianastraat 46, 4301 NC, Zierikzee, +31 (0) 111 450 127 3

Light specifications Board: 1*GrandMa 1 Fullzise Conventional: Fronts 6* theater spot Fresnel (500W) ACL 2* aircraft: pair of 4x par 64 VNSP (250W/28V, 8pcs in series, 1ch * 2000W) Par 24* par 64 NSP (GX16D - 1000W/115V, 2pcs in series, 12ch * 2000W) Intelligent: Color changers Mirror heads 5* Color Pro HXi CMY 6ch mode 6* Martin RobocolorPRO 400 8* Martin CX4 (HTI-150) 7* Martin Alien CMY 6* Martin Roboscan 518 9ch mode Moving heads 4* Showtech Phantom 50 LED Spot MKII Lasers 2* Laserworld CS 1000RGB MKII Equipment: Hazer Fogger Mirror Ball Blacklight In Audience: Antari ZM350 Look Viper NT 230V 50cm (DMX control: power on, rotation, down, up) 3* TL 36W, 120cm 16* pin spot (low voltage 8pcs in series, 2ch ) 5* par56 EuroLite LED RGB (20W) Dimmers (Rack mounted fixed system) 1* EuroLite DMX 4X, 4ch DMX splitter, 1* IES DMX to analog converter. 2* IES 6ch DMX analog dimmer (2500W/ch) 1* IES EXECUTOR 15AI, 6ch DMX dimmer (2500W/ch) Dimmers (loose pcs) 8* EuroLite EDX4 DMX, 4ch DMX dimmers (1500W/ch) 3* Showtec Multiswitch, 4ch DMX switchpack (max 1150W/ch, max 3680W tot) 2* Showtec Titan Strobe 1500watt (PX1500W) Light Power outlets on stage Left 1* 400V 32A CEE (MK/K2 3x25A) General purpose power outlet (stage Left): 4* 230V 16A Schuko (OV1/G7,G8) Since we work with a fixed, non-patchable installation, not every request can easily be honored. If you have special requests for light effects, please contact us a few weeks ahead. Our engineers are willing to help you out, but are very limited in their spare time. Julianastraat 46, 4301 NC, Zierikzee, +31 (0) 111 450 127 4

For additional information please contact licht@brogum.nl Julianastraat 46, 4301 NC, Zierikzee, +31 (0) 111 450 127 5

PLAN (ground level) Electrical lay out: MK: Main switchboard- 3xC80A OV1-3x25A (entrance) OV2-3x25A (kitchen) K1-3x25A-Stage (audio) K2-3x25A-Stage (light) K3-3x63A (Anywave light) K4-3x35A (not in use) K5-3x35A (dimmer rack light) K6-3x35A (Anywave audio) OV3-3X25A (backstage) CEE1-3x25A (Anywave beer cooler) CEE2-3x25A (Anywave spare) OV1: (entrance) G1-16A Noodverlichting G2-16A Wagenschuur G3-16A MK G4-16A entree G5-16A toiletten G6-16A CV G7-16A (light) G8-16A (light) G9-16A (audio) G10-16A (audio) OV2: (kitchen) G1 pre cooler beer G2 outlets G3 chillroom, internet, storage G4 office on second floor G5 light kitchen, office, centr. heat/ hot water G6 dishwash, tosti G11 bar audio, wcd, beamer G7 bar TL, spot, wcd G12 hall spots, outside spots G8-spare G13 ventilation, extraction G9-spare G14 bar cooling units, coffee G10-spare G15 main hall light TL OV3: (backstage (un) loading) G1-3x16A lights (un)loading G2-3x25A L1 G3-3x25A L2 L1: (backstage 1) G1 toilet (wcd, not in use) G2 heater shower, wcd (heating) G3 light, ventilation, wcd G4 not in use L2: (backstage 2) G1 emergency lights, outside entrance light G2 boiler G3 heater shower G4 lights, wcd G5 wcd (heating) S1 entrance side light Julianastraat 46, 4301 NC, Zierikzee, +31 (0) 111 450 127 6

PLAN (terrain) Brogum popcultura BTW nr: NL005524131B01 Julianastraat 46 KVK nr: 41113359 4301 NC Zierikzee Bank: NL44 RABO 0137850328 the Netherlands +31 (0)111 450 127 www.brogum.nl info@brogum.nl Terrain Brogum scale 1 : 500 Julianastraat 46, 4301 NC, Zierikzee, +31 (0) 111 450 127 7