VRL PAR-1745 Par Lamp

Similar documents
TABLE OF CONTENTS INTRODUCTION

LED Spere Direct Control 30 ORDERCODE 41125

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Design LED 36. Elation Professional 4295 Charter Street Los Angeles, Ca Rev. 11/17/06

Stratos Duo RGB. User Manual. Order code: EQLED371

LED-PAR200B USER MANUAL. COLORsplash 200B

Design LED 36WA. Elation Professional 4295 Charter Street Los Angeles, Ca Rev 3/08/07

LED Thunder S-150 Code 1097

Design LED 60 Strip WA. Elation Professional 6122 S Eastern Ave Los Angeles, Ca Rev.

NEO-STB-0004 Neo-Flash 300 RGB User Manual

LED-BANK4 USER MANUAL. COLORbank 4

Colour Control48 Order Code: Control48

ORDER CODE: EQLED65 USER MANUAL

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

WaferPar QUAD-W 7 CKU (US) / CKE (EU) USER MANUAL

Flat LED Par Can Light

American DJ. User Instructions. American DJ

Fusion 120 Zoom. User Manual. Order code: EQLED068

American DJ. User Instructions

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do

LED IP65 Slimline Par RGBWA +UV 7x12W

LED Techno Strobe RGB ST-4000RGB USER MANUAL

Spectra Batten (Order code: LEDJ95)

192 Channel DMX Controller

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

LED PAR 36 USER MANUAL

LIGHT COPILOT II. elationlighting.com Internet:

American DJ. User Instructions. Model: Mega Bar 50RGB

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

Design LED 36 Brick. Elation Professional 6122 S. Eastern Ave. Los Angeles, Ca Rev. 1/4/2010 visage

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

ELAR EXTQW FLOOD HP. user manual. ELATION ELAR EXTQW FLOOD HP user manual

LED Spot 300W. Please read this user manual before your operation

LED Par 36 COB RGBW 12W, LED Par 46 COB RGBW 20W, LED Par 64 COB RGBW 60W, LED Par 56 COB RGBW 30W LED PAR. user manual

Design LED 12 Brick II. Elation Professional 6122 S. Eastern Ave. Los Angeles, CA Rev. 03/08/08

Hex-color RGBAW+UV LED strip light

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

COLORtube EQ Controller

Mini Stage Par 4 8W QCL RGBA/RGBW 25 /40 LED PAR. user manual

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

USER MANUAL. TS-3 DMX-Scanner. For your own safety, please read this user manual carefully before you initial start-up.

thinpar 38

CUEPIX BLINDER WW2. user manual. ELATION CUEPIX BLINDER WW2 user manual

Opti Tri White Par. User Instructions

DMX LED light effect with 4 lenses

HEX16 Strip User Manual

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

LED Par 56 Short Eco V2 ORDERCODE 42417

DMX Operator 192-channel lighting controller

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

EPAR QW. User Instructions

EPAR QA. User Instructions

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

ElektraLite lightstream

1. BEFORE YOU BEGIN INTRODUCTION CONTROL FEATURES... 5 Additional Features... 5 PRODUCT OVERVIEW SETUP... 6

Mini LED Pin Spot Light Model: PLS00571

SIXPAR 100. user manual. ELATION SIXPAR 100 user manual

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

4LEDKIT-DJ USER MANUAL. LED Tricolor 4-PAR Lighting Kit. Please read this manual carefully and proper take care of this manual.

USER GUIDE IRLEDS SERIES - LED PAR PROJECTORS WITH INFRARED REMOTE CONTROL

PRO PAR HEX 12. User Manual

PRODUCT SPECIFICATIONS

ELED PAR RGB ZOOM. User Instructions. Elation Professional 6122 S. Eastern Ave. Los Angeles CA

American DJ. User Instructions. American DJ Charter Street Los Angeles Ca Introduction

Introduction: The Dekker is part of American DJ s continuing pursuit for creating high quality affordable intelligent fixtures.

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

LED Par 56 Short Eco V2 ORDERCODE 42417

Glow P54 White LED Par

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

User Manual. Xstatic Pro, Inc Essex Street - Brooklyn, NY Version 1.2

Owner Handbook Saturn Quad Beam. Owner Handbook. Saturn Quad Beam

RGB 3C IR. User Instructions

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

1. Before you Begin Introduction Setup Operation Technical Information Technical Specifications...

ARENA PAR ZOOM. user manual. ELATION ARENA PAR ZOOM user manual

Octagon Theater CW/WW/A 20 6W LED PAR. user manual

BROTHER, BROTHER & SONS

Measurements are expressed in millimeters.

Jelly Par Profile System Introduction Unpacking: Introduction: Customer Support: Warning! Caution! User Instructions

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

ARENA PAR ZOOM. user manual. ELATION ARENA PAR ZOOM user manual

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

DMX OPERATOR PRO. User Manual

USER S MANUAL

SAFETY WARNINGS AND GUIDELINES INTRODUCTION CUSTOMER SERVICE

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

Owner Handbook Neptune Tumbler. Owner Handbook. Neptune Tumbler

Wizard Extreme. user manual

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX. Master/Slave. Auto-ranging Power Supply. Replaceable Fuse.

USER MANUAL Table of Contents

USER MANUAL (SSDL-3201RGB)

User Instructions. Customer Support: American DJ provides a toll free customer support

Transcription:

1

Table of Content Part I General Information 1.1 Introduction...3 1.2 Safety Information.. 3 1.3 Unpacking..4 1.4 Specifications....4 1.5 Features.. 4 1.6 Panel review 4 Part II Installation and Operation 2.1 AC Power.5 2.2 Understanding DMX...6 A. About DMX...6 B. DMX Cable Requirement..6 C. Connection of DMX.6 D. DMX Addressing.. 7 2.3 Operation Instructions.. 7 Brief function chart......7 Mode choose.......7 A. Auto Mode.......7 B. Sound Active Mode.... 7 C. DMX Mode......7 D. Master/slave mode... 9 Part III Maintenance and Cleaning..8 Appendix 10 2

PART I GENERAL INFORMATION 1.1 Introduction Thank you very much for purchasing the VRL PAR-1745, our 5-channel LED Par Lamp series product that can work in AUTO, AUDIO and DMX mode. To assure reliable performance please read the instructions in this manual thoroughly before application. 1.2 Safety Information The following definitions of identifying the severity of the hazards associated with the products are used: DANGER Imminently hazardous situation which, if not avoided, will cause death or serious injury. WARNING Potentially hazardous situation which, if not avoided, could cause death or serious injury. CAUTION Potentially hazardous situation which, if not avoided, may cause minor or moderate injury or property damage. In addition, it uses to alert against unsafe practice. IGNORING A HAZARD WILL VOID ANY WARRANTY. DANGER: Ensure that the fixture is disconnected from the main power before performing any type of service or any cleaning procedure. WARNNING: No serviceable parts inside the fixture, do not attempt to open it. WARNNING: The Installation must be performed by qualified professional in accordance with related local codes. WARNNING: Do not attempt to operate the fixture before read and understand the installation instructions and safety labels. CAUTION: Do not modify, alter, or attempt to service the VRL PAR-1745. CAUTION: Always ground (earth) the fixture electrically. CAUTION: Refer all service to a qualified technician. CAUTION: When suspending the fixture above ground level or place it on the ground, verify that the structure or surface can hold at least 10 times the weight of all installed devices. 1.3. Unpacking 3

The VRL PAR-1745 has been thoroughly tested and shipped in perfect operating condition. Check the shipping carton carefully for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your fixture for damage and be sure all accessories necessary to operate the fixture have arrived intact. In case damage has been found or parts are missing, please contact the sales person for further instructions. You can find the following components inside the box: 1. A set of VRL PAR-1745 2. A 3-pin DMX XLR cable 3. This User Manual 4. A 3-wire IEC power cable 1.4. Specifications: Power Supply: AC240V/50Hz LED Configuration: 174PCS(R=80PCS 0.044w,G=66PCS 0.064w,B=54PCS 0.064w) Power Consumption: 19W Dimension (mm): φ225x340 Weight: 2.3 kg 1.5. Features: Low power consumption Maintenance free operation 100,000 hours rated LED lifespan 174 PCS of LED generates 16.7 million additive RGB colors DMX or stand-alone mode with Master/Slave function 18 built-in programs accessed via DMX-controller or manually Sound-activated via built-in microphone of adjustable sensitivity Brilliant light output 1.6.panel review PART II Installation and Operation 4

2.1 Mounting The fixture can be mounted overhead by a clamp or against a flat surface by the included bracket. When you mount overhead, you can connect its bracket with the clamp through the center hole. Verify that the structure you are mounting to can hold 10 times the combined weight of all installed fixtures. Always use a safety cable or chain as an assistant attachment. The safety cable or chain must hold 10 times the combined weight of all installed fixtures. 2.2 AC power The fixture s mains lead may require a grounding-type cord cap that fits your power distribution cable or outlet. Consult a qualified electrician if you have any doubts about proper installation. WARNNING: For protection from dangerous electric shock, the fixture must be grounded (earthed). The AC mains power supply shall have overload and ground-fault protection. CAUTION: Verify that the feed cables are undamaged and rated for the current requirements of all connected devices before use. Following the cord cap manufacturer's instructions, connect the yellow and green wire to ground (earth), the brown wire to live, and the blue wire to neutral. The table below details some pin identification schemes. Wire Pin Marking Screw color Brown Live L Yellow or brass Blue Neutral "N Silver Yellow or green Ground 〨 Green 2.3 Understanding DMX 5

A. About DMX DMX is the abbreviation of Digital Multiplex. It s a universal protocol used by most audio, lighting and controller manufactures as a form of communication between fixtures and controllers. A DMX controller sends out DMX data instructions to the fixtures via 5-pin XLR cables. The data travels through the DMX chain as a serial data. DMX is a kind of "common language" allowing all products of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compatible. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. B. DMX Cable Requirements: Your fixture, VRL PAR-1745 uses 3-pin XLR cable as connection media. We provide each fixture with a 3-pin XLR cable for you to chain the fixtures. C. Connection of DMX Connect the provided DMX XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-pin XLR input of the fixture (please refer to the figure PART II Installation and Operation below). You must chain multiple fixtures together through serial linking, never split your DMX connections unless you are using our splitter/signal amplifier such as SRL-144. D. DMX addressing All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to "listen" to the digital control information sent out from the DMX controller. The allocation of this starting DMX address is achieved by various combinations of the dipswitches. This fixture employs 10 dipswitches to access its functions. Normally the dipswitches from #1 to #9 are used for encoding DMX address, the dipswitch #10 for enable DMX mode. 6

Dipswitch 1 address equals to 1 Dipswitch 2 address equals to 2 Dipswitch 3 address equals to 4 Dipswitch 4 address equals to 8 Dipswitch 5 address equals to 16 Dipswitch 6 address equals to 32 Dipswitch 7 address equals to 64 Dipswitch 8 address equals to 128 Dipswitch 9 address equals to 256 DMX address=dipswitch 1+Dipswitch 2+ +Dipswitch 9. 2.4 Operation Instructions Brief function chart Switch Function #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 DXM Set DMX address (see DMX address chart in details) 1 Slave X X X X X X X X X 1 Fade Choose program via Choose speed via and switch1~3(see switch4~6 ( See 1 X 0 0 Master Auto program choose speed choose chart Auto chart in details) in details) 0 X 0 0 Sound X X X X X 1 0 Notes! Important 1. In sound active mode: No fade; Run to sound; Choose different programs via switch1~3 2. Connect DMX controller with the fixture through 3-pin XLR signal cord. 3. In master/slave mode, fixtures can run at the same time by setting one of fixtures as auto mode, the left DMX mode. 4. In DMX mode, please pay attention to such points: set DMX channel address via switch1~9 ranging from 1~512. 7

Mode choose A. Auto mode When dipswitches #9 &#10 are both set at OFF, the fixture works in Auto mode. The detailed setting you can check in the following table: Combination of Dipswitch #1, #2 and #3 to select different PROGRAM: Dip #1 Dip #2 Dip #3 PROGRAM selected OFF OFF OFF PROGRAM 1(red twinkle ) ON OFF OFF PROGRAM 2(Green twinkle) OFF ON OFF PROGRAM 3(Blue twinkle) ON ON OFF PROGRAM 4(Red and Green twinkle) OFF OFF ON PROGRAM 5(Red &Blue twinkle) ON OFF ON PROGRAM 6(Green &Blue twinkle) OFF ON ON PROGRAM 7(Red, Green &Blue twinkle) ON ON ON PROGRAM 8(7-color twinkle) Dipswitch #4, #5 and #6 specify the speed of the running PROGRAM with 8 levels of different speed adjustable. Dipswitch #7 is for FADE selection. OFF turns FADE off while ON turns FADE on. B. Sound Active mode When dipswitch #9 is ON and dipswitch #10 is OFF the fixture works in Sound active mode. Various combining of dipswitch #1, #2 and #3 forms different PROGRAM DIP #1 DIP #2 DIP #3 PROGRAM selected OFF OFF OFF PROGRAM 1(red twinkling ) ON OFF OFF PROGRAM 2(Green twinkling) OFF ON OFF PROGRAM 3(Blue twinkling) ON ON OFF PROGRAM 4(Red and Green twinkling) OFF OFF ON PROGRAM 5(Red &Blue twinkling) ON OFF ON PROGRAM 6(Green &Blue twinkling) OFF ON ON PROGRAM 7(Red, Green &Blue twinkling) ON ON ON PROGRAM 8(7-color twinkling) In this mode step is triggered by the rhythm of sound. C. DMX mode When dipswitch #10 is set at ON, the fixture works in DMX mode. By various combining the Dipswitches #1 to #9 you can set the address ranging from 1 to 512. At this moment, the fixtures can be controlled by DMX controller or another fixture that has been designated as Auto or Sound Active mode with 5 channels receiving the data controlling the Red, Green, Blue, brightness and strobe rate output of the fixture respectively. Note: the address encoded by combining dipswitches #1 to #9 function as initial channel address. 8

DMX channel and function chart Channel Value Function CH1 0~255 Adjust CH1 value 0~255 and brightness of red LED is 0~100% CH2 0~255 Adjust CH2 value 0~255 and brightness of green LED is 0~100% CH3 0~255 Adjust CH3 value 0~255 and brightness of blue LED is 0~100% CH4 0~255 Adjust CH4 value 0~255 and brightness of all LEDS is 0~100% 0~10 No strobe CH5 11~255 Adjust CH5 value 11~255 and all LEDS strobe. Strobe speed is from slowest to fastest. D. MASTER/SLAVE MODE Set switch 10 of slaves ON and switch 10 of master OFF, it is in MASTER/SLAVE mode and they can run at the same time. Master mode has three working ways: auto with fade, auto without fade and sound. You can choose program via switch 1~3 and choose auto speed via switch 4~6 in auto mode. PART III MAINTENACE AND CLEANING Please refer to the following points during the normal inspection: A. Be sure all screws and fasteners are securely tightened at all times. Loose screws may cause unexpected damage or injury. B. Electric power supply cables must not show any damage or frayed spot. CAUTION: Make sure that the power cord of the unit is disconnected from the mains before performing the following operation to avoid shock hazard! We recommend, if possible, frequent cleaning of the device, which will ensure its long lifespan and bright light output. While performing the cleaning, please always make sure that the power cord is disconnected from the mains and use a moist, lint-free cloth. Avoid using any alcohol or solvents, as they are harmful to the fixture. 9

APPENDIX DMX address chart SWITHC SET 0 = OFF 1 = ON #9 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 #8 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 #7 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 #6 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 #1 #2 #3 #4 #5 0 0 0 0 0 32 64 96 128 160 192 224 256 288 320 352 384 416 448 480 1 0 0 0 0 1 33 65 97 129 161 193 225 257 289 321 353 385 417 449 481 0 1 0 0 0 2 34 66 98 130 162 194 226 258 290 322 354 386 418 450 482 1 1 0 0 0 3 35 67 99 131 163 195 227 259 291 323 355 387 419 451 483 0 0 1 0 0 4 36 68 100 132 164 196 228 260 292 324 356 388 420 452 484 1 0 1 0 0 5 37 69 101 133 165 197 229 261 293 325 357 389 421 453 485 0 1 1 0 0 6 38 70 102 134 166 198 230 262 294 326 358 390 422 454 486 1 1 1 0 0 7 39 71 103 135 167 199 231 263 295 327 359 391 423 455 487 0 0 0 1 0 8 40 72 104 136 168 200 232 264 296 328 360 392 424 456 488 1 0 0 1 0 9 41 73 105 137 169 201 233 265 297 329 361 393 425 457 489 0 1 0 1 0 10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490 1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498 1 1 0 0 1 19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499 0 0 1 0 1 20 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500 1 0 1 0 1 21 53 85 117 149 181 213 245 277 309 341 373 405 437 469 501 0 1 1 0 1 22 54 86 118 150 182 214 246 278 310 342 374 406 438 470 502 1 1 1 0 1 23 55 87 119 151 183 215 247 279 311 343 375 407 439 471 503 0 0 0 1 1 24 56 88 120 152 184 216 248 280 312 344 376 408 440 472 504 1 0 0 1 1 25 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505 0 1 0 1 1 26 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506 1 1 0 1 1 27 59 91 123 155 187 219 251 283 315 347 379 411 443 475 507 0 0 1 1 1 28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508 1 0 1 1 1 29 61 93 125 157 189 221 253 285 317 349 381 413 445 477 509 0 1 1 1 1 30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510 1 1 1 1 1 31 63 95 127 159 191 223 255 287 319 351 383 415 447 479 511 10