Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Similar documents
Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.

Latrobe Performing Arts Centre

John Leslie Theatre. Technical Specifications. Updated July 2018

Matt Dann Cultural Centre

Esso BHP Billiton Wellington Entertainment Centre

2017 TECHNICAL SPECIFICATIONS

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Yan Yean Theatre Technical Specifications

Mildura Arts Centre. Mildura Arts Centre Theatre. Technical Specifications. Updated 23/6/06

Monash Academy of Performing Arts

THE STREET THEATRE. Technical Specifications

Monash University Academy of Performing Arts

MONASH University Academy of Performing Arts

Orange Civic Theatre

RPAC REDLANDS PERFORMING ARTS CENTRE

Technical Specifications

D A R E B I N A R T S & E N T E R T A I N M E N T C E N T R E

Don Russell Performing Arts Centre

Technical Specifications

DEREHAM MEMORIAL HALL

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Alexander Theatre. Technical Specifications. Monash University VIC enter via Wellington Road

Dr JOHN GALLAGHER CONCERT CHAMBER

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

THEATRE Technical Specifications

Monash Academy of Performing Arts (MAPA) Alexander Theatre. Technical Specifications

CENTRE FOR PERFORMING ARTS

Gosford City Council

Darebin Arts & Entertainment Centre. Theatre

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Main House Technical Specification

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Technical Services and Specification

Queensland Performing Arts Centre

Technical Specification

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

The Haymarket Basingstoke Technical Specifications

HIRE AND TECHNICAL INFORMATION

Technical Specifications

Technical Specification Pavilion Dance

Powerhouse Theatre technical information and general specifications 2017

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

Bathurst Memorial Entertainment Centre Theatre Technical Specifications 2014

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

ISLAND HALL TECHNICAL INFORMATION

Theatre Technical Specifications

Generated from the APACA Technical Specifications Template. For more details visit Clocktower Centre.

CHELSEA THEATRE. Technical Specifications

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Technical Specification for the Alley Theatre, Strabane

Technical Specifications

Sandusky State Theatre Technical Specifications

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

Theatre Technical Specifications

Access to back stage is off Fletcher St on the eastern side of the building

There are 10 dressing rooms in Theatre Kerkrade.

Dr. Fred Speckeen Theatre. Information and Technical Specifications

TECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem,

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

TECHNICAL PACKAGE.

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Performing Arts Theatre

TECHNICAL SPECIFICATIONS

Technical Specifications

Technical specifications Main theatre. Sound

Summary. Access and Parking

Arcadia Performing Arts Center Technical Specifications and Information

Hopgood Theatre NOARLUNGA CENTRE

JERWOOD VANBRUGH THEATRE

Technical Information

UNIVERSITY CONCERT HALL. Technical Specification

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Technical Information

Visy Theatre technical information and general specifications 2019

Technical Informa on.zack Theater

Cornerstone Technical Specifications 2018 / V1

Project manager (PM): Pamela Næss Mail: Phone:

Roundhouse Theatre. Roundhouse Theatre. Technical Specifications. Updated 28/4/2008

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

New Theatre Royal Lincoln Technical Information

Patriots Theater at the War Memorial Technical Data

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

SHUBERT THEATER 247 College Street, New Haven, CT

INFORMATION FOR VISITING COMPANIES

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

TECHNICAL RIDER. STAGE 32 m wide x 13 m deep (from setting line / mid point)

Technical Specifications and Inventory Spring 2018

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Technical Specifications

Darlington Hippodrome Technical Specification

Transcription:

Technical specifications STAGE Brief stage description Stage one: With retractable seating out, unraked stage without a proscenium arch or fly tower (10 metre ceiling). Surface hardwood floor covered with masonite sheets. Stage two: Modular stage 1m x 2m sections total of 80m². Stage height 500 to 800mm with disabled access. Stage point load limit: Stage point load of 700kg Stage rake: No Stage dimensions Non-proscenium stage Theatre stage: Width 14m Depth 10m Modular stage: 80m² of modular staging at two heights of 500mm to 800mm. Access door to stage from scene dock - 2.9m by 2.9m. After hours access to loading dock is available upon arrangement. Setting line 200mm upstage from the fire curtain. Distance from (SL = Setting line, CL = Centre line) SL to DS edge of orchestra lift/pit 800mm SL to first fly line 350mm SL to last upstage fly line 8.7m SL to rear wall 9.7m CL to OP wall (or obstruction) 9.4m CL to PS wall (or obstruction) 9.4m Stage to underside of grid 7m PLEASE NOTE: This may be different to the batten drift measurement. Overhead obstructions N/A thecubewodonga.com.au 1 of 11

AUDITORIUM The auditorium consists of a retractable seating system with a level one balcony. Seating capacity with additional seating pit installed and balcony - 410 Seating capacity without seating pit and seats added at floor with a reduced stage can see a seating capacity - 550 ORCHESTRA LIFT/PIT Orchestra pit There is no orchestra pit, there is a seating pit that could be cleared and used. Depth of pit is 1.5m Width of pit is 17m Length of pit is 3m DRAPERY Type Material Colour Width Height Quantity House curtain Wool, 50 per cent / 500gsm Black 10.3m 9.5m One pair Borders Legs Valance Travellers Wool, 50 per cent / 500gsm Wool, 50 per cent / 500gsm Wool, 50 per cent / 500gsm Wool, 50 per cent / 500gsm Black 14.8m 3.5m Five Black 2.4m 7.8m Three pair Black 20m 3.5m Two Black 7.5m 7.8m Two pair thecubewodonga.com.au 2 of 11

HANGING PLOT SL: Setting line as indicated previously Line type: SP = Single purchase, DP = Double purchase, MW = Motor winch, HW = Hand winch, HL = Handline W.L.L.: Maximum distributed load including bar weight PLEASE NOTE: All legs are dead hung. Line no Distance from SL (mm) Line type W.L.L Venue allocation 1 Front of house (FOH) curtain 2 100 HW 500 Border 3 500 MW 500 LX one 4 1100 MW 500 Sq truss (5m) 5 1700 DH NA Border 1800 DH NA Legs two 6 2000 HW 420 Web truss 7 2950 MW 500 Sq truss (5m) LX three 8 3600 DH NA Border 3700 DH NA Legs three 9 3900 HW 420 Mid-stage traveller 10 4350 MW 500 LX four 11 5100 MW 500 Sq truss (5m) 12 5800 HW 420 Web truss 13 6900 DH NA Border 7000 DH NA Legs four 14 7100 MW 500 LX five 15 7950 HW 420 Rear traveller 16 8150 HW 420 Web TR 17 8250 HW 420 CYC ACCESS EQUIPMENT Elevated: work platform Snorkel s3246e Maximum drive speed (extended).8km/h Maximum drive speed (stowed) 3.2km/h Maximum reach is: Platform height is 9.75m Maximum reach is 11.8m EWP restrictions Use is at the discretion of technical co-ordinator. Ladders: Six foot A frame aluminium ladder Lift pod - working height of 4.2 meters thecubewodonga.com.au 3 of 11

STAGING UNITS LOADING DOCK Power stage: 40 stage sections 1m by 2m, heights of 500mm for 40 square meters of stage area and 800mm for 80 square meters of stage area. Access: Truck access off Hovell St to loading dock at rear of building. Loading dock height - 4.5m Door dimensions - 4m (high) by 3.5m (wide) ADDITIONAL RIGGING NOTES 11 rigging points in auditorium floor and stage, request additional information from the venue if required. LIGHTING Positions Stage LX bars: Fixed PLEASE NOTE: See hanging plot for standard LX bar locations. Orchestra bar Setting line to lighting bar: Distance is adjustable from setting line. Height of 8.5m. Usable bar width: 14.2m Notes: Moveable FOH bridge one Setting line to lighting bar: 15.3m Usable bar width: 14.1m FOH perches (PS and OP ) Setting line to FOH perch: LX bar runs horizontally around entire venue. PLEASE NOTE: Distances are to the highest downstage point of boom or perch. FOH booms (PS and OP) Setting line to FOH boom: LX bar runs horizontally around entire venue. PLEASE NOTE: Distances are to the highest downstage point of boom or perch. thecubewodonga.com.au 4 of 11

Control Primary desk: Vista T2 Lighting desk: Primary desk vist T2 Control channels: 512 Signal output: DMX Signal distribution: DMX available at various locations on each level throughout auditorium. Minimum of four outputs per level. Remote riggers available onstage: Yes Dimmer racks Dimmer quantity: 120 (10 racks at 12 dimmers each) Dimmer locations: Dimmer room located at balcony level above stage OP side, three additional dimmer racks are available on request. These can be relocated to the stage or where required. Per dimmer Va : 2500 House lights Independent control: Dinalite LED house lights Control positions: Stage OP and P sides, bio box, rear of auditorium floor level, box office Fade time adjustable: Yes Stage luminare Profiles Make Model Angle Detail/ ETC ETC Source four zoom spot Source four zoom spot Watt 15 to 30 12 25 to 50 24 thecubewodonga.com.au 5 of 11

Fresnels Make Model Detail/ Watt ETC Source four fresnel 24 ETC Source four ParNel 10 Par cans Make Model Angle Detail/ ETC LedTechnik pro par three Source four PAR LED pro PAR 64 tri-colour Watt 24 12 Movers Make Model Control channels Varilite Detail/ Watt VL1100TSDs 20 Gobo 1100 6 Terbly Rockwash 12 6 Followspots Unavailable Patching Location Quantity Numbering (PS to OP) Detail/ DS PS 12 47-59 Eight by 10amp GPOs available MS PS 4 43-46 US PS 12 31-42 Four by 10amp GPOs USC 4 29-30 Four by 10am GPOs OS OP 16 13-28 Eight by 10am GPOs DS OP 12 1-12 Eight by 10am GPOs available FOH (ground) 20 OP 111-118 PS 101-108 FOH level one 36 OP 301-316 PS 325-340 Level one mix position FOH level two PS FOH level two OP 10 by 10amp GPOs 12 by 10amp GPOs 4 319-322 8 by 10amp GPOs 32 501-532 12 by 10amp GPOs 32 537-568 12 by 10amp GPOs thecubewodonga.com.au 6 of 11

Level twomix position Gallery PS 4 533-536 12 by 10amp GPOs Four by 10amp GPOs Gallery US 16 465-480 Two by 10amp GPOs Gallery OP LX one 16 401-416 LX two 16 481-496 LX three 16 433-448 LX four 16 417-432 LX five 16 449-464 Two by 10amp GPOs POWER Three-phase outlets: Three by 40amp OS PS Three by 40amp plus one by 40amp Green OS OP Three by 40amp FOH level one Two by 40amp FOH level two Two by 40amp gallery CABLING 240v extension cable: Theatre has a good stock of extension leads to accommodate the venue s standard lighting rig. Any additional equipment may require additional cable stock to be sourced. Looms: Theatre has a good stock of looms in various lengths. AUDIO Control positions Control room: The venue has no dedicated control position. Auditorium: At floor level, centre rear of auditorium, OP and P sides of stage. Other: Rear of audience gallery level one, rear of technical gallery level two. Control and amplification Primary mixer: Soundcraft Si Compact 32 FX: Lexi con MX400 Compression/limiter/gates: Yes Speakers FOH speakers: JBL VRX 932 LAP JBL VRX 918 SP thecubewodonga.com.au 7 of 11

Foldback: JBL PRX 512MI Stage monitor x2 Quest QM12 DCx2 JBL Eon 510 x2 QSC GX5 Amp Playback: Item Make Model Detail CD player Tascam SS-CDR200 2 Microphones: Make Model Detail/ Use Shure Beta 58A Vocal 4 Shure Beta 57 Instrument 4 Shure Beta 52 Dynamic 1 Shure ULX/S Radio mic lapel/ headset Shure MX202 Choir mic 4 Shure KSM137 Condenser mic Accessories: Item Model Detail/ Mic stand - straight 4 Mic stand - boom 6 Mic stand - short 4 Line patching: Location Quantity Numbering Sends/Returns Detail 4 2 Orchestra pit 10 Eight sends, two returns Onstage 16 7-22/155-170 Eight sends, eight returns Level two OP 16 33-36/181-184 Level two PS 8 37-40/185-188 Level two seating Eight sends, eight returns Four sends, four returns 4 41-44/41-44 Four sends, four returns Cabling: Audio cable Available on request. Audio notes Front of house speakers rigged on chain motors. Position adjustable. thecubewodonga.com.au 8 of 11

AUDIO VISUAL Projectors: Type Model Detail/ Optima EH7500 WT91 1.45-1.94:1 1 Screens: Projection screen - front rear projection screen: 14m x 7.7m Switcher scaler kramer VP347 Proscale Projector rigging points: Projector has a mounting assembly and can be rigged from most horizontal lighting bars. BACK STAGE Communications Stage manager s desk: Stage manager s desk can be positioned on either side of stage. It can also be relocated to the technical position on either level one or level two. It is fitted with two by monitors, lights, clock, timer, comms and paging microphone. Talkback: Master unit: Telex BTR 80N substations: Eight headsets: Eight Radio units in-house: Four Talkback patching located at: Stage manager s desk Control room (master) 12 onstage 12 on each level Paging /show relay: Paging to the dressing rooms is available from the stage manager s desk. Show relay is distributed to all dressing rooms and green room. Each room has an individual volume control. Stage monitor: Camera located centre of the balcony bar. Monitor on stage manager s desk. Feed available to all areas. thecubewodonga.com.au 9 of 11

Dressing rooms Dressing room Dressing room one Capacity Toilets Showers Details Three Yes, accessible Yes Fully accessible dressing room Dressing room two Dressing room three Fifteen Fifteen Shower and toilet access across hallway Shower and toilet access across hallway Laundry/wardrobe Washing machines: One Dryers: One Drying rooms: N/A Iron/ironing board: One Clothes racks: Two Production facilities Production desk: TBC Production office: No Phone: Yes. Located in the green room. Fax: Available on request. Access to phone for internet access: Wi-Fi will be available throughout the venue. Green room Tea/coffee facilities: Yes Fridge/freezer: Yes Microwave: Yes Running water: Yes Stage door Access: Stage door is located near the loading dock on Havelock St. Access to be negotiated through venue. thecubewodonga.com.au 10 of 11

VENUE Venue address, 118 Hovell St,, VIC 3690 Postal address, PO Box 923,, VIC 3689 Website thecubewodonga.com.au Staff contacts Technical co-ordinator Adrian Yates Phone: (02) 6022 9333 Mobile: 0403 601 946 Email: ayates@wodonga.vic.gov.au Team leader Chelsea McLaren Phone: (02) 6022 9223 Mobile: 0418 558 267 Fax: (02) 6022 9643 Email: cmclaren@wodonga.vic.gov.au PLEASE NOTE: Document correct as at January, 2016. thecubewodonga.com.au 11 of 11