Installation Guide. Cellular Plug-in for Inverters with SetApp. Version 1.1

Similar documents
MiraScreen Wire Powered by EZCast

InnoMedia ESBC B. Quick Install Guide. 1

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

VNS2200 Amplifier & Controller Installation Guide

ES-5500M V2 / ES-5800M V2

DDW36C Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement

DTA Easy Setup Guide. Installation Operation Troubleshooting

User Manual MODEL: KKW700V. Non-Touch True Display LCD Monitor. Installation Guide. 7 True Display LCD Monitor (VGA Interface)

MONOPRICE. Blackbird 4K HDBaseT Extender Kit. User's Manual P/N 21792

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

PLL1920M LED LCD Monitor

SmartBox. User Manual. Turn your TV into a SmartTV! Plug n play. Wireless Dual Band

IPSTB1200 /IPC3200 Media Client User guide

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

ES-3305P / ES-3308P / ES-3316P. Quick Installation Guide / v1.0

Inside the Box. Touchscreen LCD 1 WAN 2 LAN. Reset Button. Power Connector. Stylus

QUICK START GUIDE. IP Camera & NVR Bundle ENGLISH

SBL Series Wireless Clock Installation Manual (V2) Table of Contents

MONOPRICE. Blackbird 4K Pro HDBaseT Extender Kit. User's Manual P/N 21609

1-In / 2-Out. HDMI Splitter User s Guide

USER MANUAL Full HD Widescreen LED Monitor L215ADS

USER MANUAL Full HD Widescreen LED Monitor L215IPS

MONOPRICE. Blackbird 4K HDMI Extender. User's Manual P/N 24281

LCD MONITOR. 27 Wide LED Monitor User Manual. User Manual P276L

PL2410W LCD Monitor USER'S GUIDE.

USER MANUAL Full HD Widescreen LED Monitor L236VA

It will cause malfunction if the monitor is operating with unspecified power supply

Home Monitoring. Wired Color Camera. User Manual. For indoor/outdoor use. Do not use in wet locations.

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

A0325. ARIA Audio Streaming Source Receiver with a built in Bluetooth 4.2 Module. ARIA Audio

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

Cellular Signal Booster

Designed in Colorado, USA. Bluetooth Cable. Quick Start Guide

PLL2210MW LED Monitor

KODAK Video Monitor CFH-V10

User Manual MODEL: KKF1500-PCAP. True FLAT P-CAP LCD Monitor. Installation Guide. 15 True FLAT P-CAP Touch LCD Monitor

DV6819 Quick Reference Guide V1.0. Smart TV Box. Quick Reference Guide. Please do read user manual before you operate the TV box.

FCC Compliance Statement

LINK POWER IR RX IR TX 12V 2A. HDMI Out EL-4KHDBT-RX-40-IR. HDBT In LINK EL-4KHDBT-RX-40-IR. User Manual

19 / 20.1 / 22 WIDE SCREEN TFT-LCD MONITOR

MONOPRICE. BitPath AV VGA Extender over Single Cat6 Cable, 120m. User's Manual P/N 16226

HP Presentation Scanner. Quick Reference Guide

PQ Labs Multi-Touch Screen G 2 Overlay

2.4 GHz WIRELESS SURVEILLANCE SYSTEM

DCL9AW. User Manual. English

MONOPRICE. BitPath AV SDI Extender over Single Cat6 Cable, 120m. User's Manual P/N 16227

PXL2760MW LED LCD Monitor

USER MANUAL. KW-11T Wireless High Definition Transmitter. KW-11R Wireless High Definition Receiver MODELS: P/N: Rev 9

ZXV10 B760H ZXV10 B760E RichMedia Box User Guide

600 Series Video Surveillance Monitors

In-Line or 75 Ohm In-Line

C-MAX. CMM-9301-V3.1S Bluetooth 4.0 Single Mode HCI Module. Description. 1.1 Features

CGA0101 Wireless Cable Gateway Quick Installation Guide

TV Connector user guide

USER GUIDE. Element PAR38 LED Model: E13-N11

Quick Start Guide. Wireless TV Connection with Dongle. GWHDKITD PART NO. Q1504-b

PLL2710W LED LCD Monitor

USB-C Multiport Mini Dock USER MANUAL UH3232

Simon XT/XTi/XTi-5 LTE Module INSTALLATION GUIDE

X-Series Expansion Cards. X-Video Card

UHF RFID Reader. Model: RRU9816. Size: 122.4mmx84mmx20mm. UHF RFID Reader RRU9816

Wireless SMART1+ Remote Operating Instructions. P/N Rev. A

DISTRIBUTION AMPLIFIER

Simon 5" TouchScreen Installation Sheet

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

1 Remove SCREWS (2) CELL-EXT Cable Assembly Installation Guide. LYNX Touch/QuickConnect Touch Controls. General Information. Remove the 3GL/3GLC

USER MANUAL. KW-11T Wireless High Definition Transmitter. KW-11R Wireless High Definition Receiver MODELS: P/N: Rev 5

Scoreboard Operator s Instructions MPCX Volleyball Control

User's Manual 3x1 Matrix Switch for HDMI 4K*2K & 3D

Set Up Your OTA Antenna & Dual-Tuner OTA Adapter

Power Injector 1520 Series

XT-HDBT-EX70-4K-KIT. Introduction. User Manual. Key Features XT-HDBT-EX70-4K-KIT USER MANUAL

How to install your ecobee room sensor

SMART Hi-Fi AUDIO *MFL * SJ8 SIMPLE MANUAL. Wireless Multi-room Sound Bar

MONOPRICE. Multiformat to SDI Converter with Scaler. User's Manual P/N 15775

VS-162 / VS-164. User Manual

HD Digital MPEG2 Encoder / QAM Modulator

IRISPen Air 7. Quick User Guide. (ios - ipad)

MWT-FM. Operation Manual. FM Single Channel Transmitter. man_mwtfm.

AWT150C/AWT150CS/ AWT151C CCD Camera

Quick Start Guide Wireless TV Connection Kit

User Instructions. 16 SCB Sync Station.

MONOPRICE. BitPath AV HDMI Extender over Single Cat6 Cable, 120m. User's Manual P/N 16228

Cellular Signal Booster

MONOPRICE. BitPath AV VGA Wireless Transmitter & Receiver Kit, 200m. User's Manual P/N 16224

ASH - EOC-01. Ethernet Over Coax Adapter User Guide

Warning...1 Safety Precaution...3

GymConnect Retrofit Module

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

Installation Guide. Wireless Display Receiver

HD Digital MPEG2 Encoder / QAM Modulator

Installation Instructions

PXL2470MW LED LCD Monitor

Golf ball tracker. Instruction manual

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

22" Touchscreen LED Monitor USER'S GUIDE

MONOPRICE. SDI to Multiformat Video Converter with Scaler. User's Manual P/N 15776

Transcription:

Installation Guide Cellular Plug-in for Inverters with SetApp Version 1.1

2 Version History Version 1.0 (initial release)- January 2019 Version 1.1- January 2019 Modified Technical Specifications modem size

3 Contents Disclaimers 4 Important Notice 4 FCC Compliance 5 Support and Contact Information 7 About This Guide 8 Chapter 1: System Compatibility Check and Upgrade 10 Software Requirements 10 Chapter 2: Cellular Plug-in and Antenna Installation 11 Package Contents 11 Clipping the Antenna to the inverter 12 Connecting the Antenna to a Vertical Surface using a Bracket 15 Installing the Plug-In in the Inverter 15 Chapter 3: Configuring Cellular Communication 18 Configuring the Inverter 18 Verifying the Connection and Viewing Communication Status 19 Viewing Error Messages and Troubleshooting 22 Technical Specifications - Cellular Plug-in 27

Disclaimers 4 Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photographic, magnetic or otherwise, without the prior written permission of SolarEdge Inc. The material furnished in this document is believed to be accurate and reliable. However, SolarEdge assumes no responsibility for the use of this material. SolarEdge reserves the right to make changes to the material at any time and without notice. You may refer to the SolarEdge web site (https://www.solaredge.com/us/) for the most updated version. All company and brand products and service names are trademarks or registered trademarks of their respective holders. Patent marking notice: see https://www.solaredge.com/us/patent The general terms and conditions of delivery of SolarEdge shall apply. The content of these documents is continually reviewed and amended, where necessary. However, discrepancies cannot be excluded. No guarantee is made for the completeness of these documents.

5 FCC Compliance Please note: This product is intended to provide remote shutdown of the SolarEdge PV harvesting system, to enable safer access to a building in the event of fire. This product DOES NOT reduce the risk of fire or protect firefighters or others accessing a building in the event of a fire. If the RS485 communication between the firefighter gateway and the SolarEdge inverter(s) is disconnected for any reason (including fire), the firefighter gateway LCD will display "No Communication" or "Partial Com.". In this case, the firefighter gateway cannot be relied upon to disconnect the SolarEdge PV harvesting system. The images contained in this document are for illustrative purposes only and may vary depending on product models. FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be

determined by turning the equipment off and on, you are encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Disclaimers 6 Changes or modifications not expressly approved by the party responsible for compliance may void the user s authority to operate the equipment.

7 Support and Contact Information Support and Contact Information If you have technical problems concerning SolarEdge products, please contact us: USA and Canada: 1 510 498 3200 Fax: +1 (530) 273-2769 Email: ussupport@solaredge.com. Support Center: https://www.solaredge.com/us/service/support Before contact, make sure to have the following information at hand: Model and serial number of the product in question. The error indicated on the Inverter SetApp mobile application or on the monitoring platform or by the LEDs, if there is such an indication. System configuration information, including the type and number of modules connected and the number and length of strings. The communication method to the SolarEdge server, if the site is connected. The inverter software version as appears in the status screen.

About This Guide This manual describes how to install and set up Cellular communication in a SolarEdge inverter. SolarEdge offers the Cellular communication option for connection of the SolarEdge inverter to the SolarEdge monitoring server. This guide assumes that the SolarEdge power harvesting system is already installed and commissioned. For additional information about how to install and commission the SolarEdge power harvesting system, refer to the relevant installation guide. This guide includes the following chapters: Chapter 1: "System Compatibility Check and Upgrade" on page 10 describes how to check the inverter SW version and upgrade if required. Chapter 2: "Cellular Plug-in and Antenna Installation" on page 1, describes how to mount, connect and verify the connection of the Cellular Plug-in and antenna. Chapter 3:"Configuring Cellular Communication " on page 18 describes, how to set up the cellular communication option in the inverter, and check the communication. About This Guide 8

9 About This Guide Technical Specifications - Cellular Plug-in on page 27, provides the electrical and mechanical specifications of the SolarEdge Cellular Plug-in. For further information, datasheets and the most up-to-date certifications for various products in different countries, please visit the SolarEdge website: www.solaredge.com.

Chapter 1: System Compatibility Check and Upgrade Software Requirements Chapter 1: System Compatibility Check and 10 To use the Cellular communication option, the communication board firmware (CPU) version must be 4.2.XX or higher(three phase inverters) or 4.4.xx or higher (single phase inverters). To check the inverter CPU version and upgrade firmware using SetApp: 1. Access SetApp and select Commissioning è Information 2. If required, upgrade to the latest available firmware :select MaintenanceèFirmware Upgrade, and follow the instructions on the screen.

11 Chapter 2: Cellular Plug-in and Antenna Chapter 2: Cellular Plug-in and Antenna Installation This chapter describes how to install a Cellular Plug -in and antenna in each of a SolarEdge devices that will communicate with the SolarEdge monitoring platform. When using multiple SolarEdge inverters in the same site, a cellular modem must be installed in each inverter. Figure 1: Cellular Plug-in connection diagram Package Contents Cellular Plug-in Antenna and mounting clip with antenna cable

Clipping the Antenna to the inverter 1. Power off the inverter: Chapter 2: Cellular Plug-in and Antenna Installation a. Turn the inverter ON/OFF/P switch to OFF. Wait 5 minutes for the capacitors to discharge. b. Turn the Safety Switch to OFF. c. Disconnect the AC to the inverter by turning OFF the circuit breakers on the distribution panel. 2. Insert the clip from the bottom of the inverter between the bracket and the inverter rear side. 3. Route the antenna cable upwards along the inner fins or the inverter side, by threading the clip and RF cable from the bottom of the inverter between the bracket and the inverter s rear side.

13 Clipping the Antenna to the inverter Figure 2: Routing the antenna cable 4. Clip the antenna vertically to the heatsink fins or the inverter side.

5. Pass the antenna cable between the mounting bracket and the rear side of the inverter or along the heatsink fins. 6. Open the communication gland at the bottom of the inverter. 7. Remove the rubber seal from the gland and insert the cable through the gland body and the opened connection of the inverter. 8. Insert the rubber seal with the cable into the gland body and reconnect the gland to the inverter. Tighten the sealing gland. Chapter 2: Cellular Plug-in and Antenna Installation 9. Pull the excess cable into the inverter so that the cable can be attached to the inverter communication board (see Figure 4). The cable connects to the cellular Plug-in as described in the next section.

15 Connecting the Antenna to a Vertical Surface Connecting the Antenna to a Vertical Surface using a Bracket For connecting the antenna to a vertical surface (i.e. a wall), use a bracket with the following recommended dimensions (not supplied by SolarEdge): Figure 3: Example of antenna bracket 1. Drill two holes in the surface and attach the bracket to it with two screws. 2. Clip the antenna onto the bracket. Make sure the antenna is vertical. Installing the Plug-In in the Inverter NOTE If the Cellular Plug-in is pre-installed in the inverter, this step is not required. 1. Remove the inverter cover as described in its manual.

To Install the Plug-in in the inverter: 1. Locate the Plug-in in its place on the communication board, as shown in Figure 4. follow these guidelines: Chapter 2: Cellular Plug-in and Antenna Installation Plug in the Plug-in making sure that all pins are correctly positioned in the Plug-in connector, and no pins are left out of the connector. Make sure that the Plug-in is firmly in place. 2. Connect the antenna cable to the cellular Plug-in and tighten manually (as shown in Figure 3). Figure 4: Installed Plug-in and antenna connector 3. Turn the AC ON.

17 Installing the Plug-In in the Inverter WARNING! ELECTRICAL SHOCK HAZARD. Do not touch uninsulated wires when the inverter cover is removed. AVERTISSEMENT! RISQUE D ÉLECTROCUTION, ne touchez pas les fils non isolés lorsque le couvercle de l'onduleur est retiré. 4. Check that all the cellular Plug-in LEDs are lit. If not, refer to "Configuring Cellular Communication " on page 18 Figure 5: Cellular Plug-in LEDs

Chapter 3: Configuring Cellular Communication This chapter describes how to configure the inverter to use cellular communication, verify the connection and troubleshoot problems. Configuring the Inverter 1. Ensure you have installed the Plug-in and antenna. For instructions see"cellular Plug-in and Antenna Installation" on page 11. 2. Activate, commission and configure the inverter (except for communication) according to the Inverter Installation Guide. Chapter 3: Configuring Cellular Communication 3. Access SetApp and select CommunicationèServer ècellular A blue check mark appears in the Cellular row indicating that a connection has been established.

19 Verifying the Connection and Viewing Verifying the Connection and Viewing Communication Status You view error messages on the Status screen. The Cellular Plug-in communicates with the SolarEdge monitoring platformcontinuously and every 5 minutes sends all monitoring data accumulated since last communication. To access the SetApp Status screen: 1. Do one of the following: During first time Commissioning and configuration: From the Commissioning menu select Status. The main inverter Status screen is displayed (see on the following page) If the inverter has already been activated and commissioned - open SetApp and follow the instructions on the screen (scan the inverter barcode; move the ON/OFF/P switch to P position (for less than 5 sec) and release. The mobile device creates a Wi-Fi connection with the inverter and displays the inverter main Status screen.

Chapter 3: Configuring Cellular Communication Status Power 100 kw P_OK: 138 of 141 Optimizers Connected Status Production CosPhi 1.00 Voltage Inverter SN 07318000C Voltage 277 Vac Limit No Limit Temp 850 Vdc 156 F Switch Off. Production disabled Frequency 60.9 Hz S_OK Server Connected Cell Switch OFF Country USA2 Fan OK Commissioning Figure 6: SetApp Status screen

21 Verifying the Connection and Viewing 2. Verify that S_OK ( inverter established a successful physical connection to the monitoring platform) and Cell (the method of communication to the SolarEdge monitoring platform) appear on the Status screen. 3. If required you can view the: mobile network operator name (MNO) on the Communication menu. The Signal strength received from the cellular Plug-in(Sig) on the Status screenfigure 6. The strength is displayed as a value between 0-5, (0 = no signal, 5 = excellent signal).

Viewing Error Messages and Troubleshooting The Inverter is not Starting Up If the inverter is not starting up, the Plug-in may have been installed in an inverter with an incompatible CPU software version. Check if the Plug-in is installed, remove it and upgrade the inverter as described in System Compatibility Check and Upgrade on page 10. You view error messages on the SetApp screen. To access the SetApp Status screen see Viewing Error Messages and Troubleshooting on page 22. Error message Description Troubleshooting Cellular Plug-in detected Not activated Chapter 3: Configuring Cellular Communication The internal Plugin is not communicating with the communication board. The cellular Plugin is not activated for use. Check that the Cellular Plug- in is installed properly: All the pins are inserted in the correct location and not shifted. Contact SolarEdge support

23 Viewing Error Messages and Troubleshooting Error message Description Troubleshooting Not registered No signal The Cellular Plug - in is not registered to a network provider. No cellular signal is received. Check antenna connection or change antenna location. Contact SolarEdge support. Check antenna connection or change antenna location. Check that the cable is connected properly to both Plug-in and antenna Contact SolarEdge support.

Chapter 3: Configuring Cellular Communication Error message Description Troubleshooting The DNS request that was forwarded to the cellular network DNS Failed provider has Contact SolarEdge failed, or there is a support. problem in the DNS registration on the SolarEdge server. TCP Connect. Failed S_OK is not displayed Connection to the SolarEdge server has failed. Communication with the SolarEdge monitoring server is not established. Contact SolarEdge support. Verify that none of the above errors appear. To force communication with the server, scroll to the Communication menu and re-select Cellular.

25 Viewing Error Messages and Troubleshooting Plug-in LED Indications Function AUX Power LEDs LED functionality All LEDs are OFF The green Plug-in power LED is ON, but one or more of the other LEDs is OFF Description The Plug-in is not connected properly The Plug-in is damaged The Plug-in is damaged Troubleshooting Check that the Plug-in is installed properly: All the pins are inserted in the correct location and not shifted. Contact SolarEdge support Contact SolarEdge support

Chapter 3: Configuring Cellular Communication Function Init LEDS LED functionality Red LED is blinking slowley Orange ON Green ON Description Troubleshooting Communication between Plug-in Indication only and main board is established The Plug is registered to a Indication only cellular network The Plug-in is connected to the Indication only Internet

27 Technical Specifications - Cellular Plug-in Technical Specifications - Cellular Plug-in Electrical Min. Typ. Max. Units Modem CDMA transmit 824-849 MHz 800 Modem Operating 869-894 MHz receive frequency range Modem 1850-1910 MHz CDMA transmit 1900 Modem receive 1930-1990 MHz Receiver input sensitivity (Forward link RF level@ -106-107 - dbm FER < 0.5%) Maximum transmit power 24 dbm Antenna connector RP-SMA Power consumption @transmit 2.5 W Mechanical Modem dimensions Through-Hole: (L x W) 3.9 x 1.25 / 78.3 x 32.2 Operating temperature -40 to +185 / -40 to +85 Compliance FCC class B, Parts 15, 22, EMC and Radio 24; Safety UL, UL60950 RoHS Yes in/mm F/ C

lf you have technical queries concerning our products, please contact our support through SolarEdge service portal: www.solaredge.com/service/support US & Canada (+1) (0) 510 498 3200 Worldwide (+972) (0) 073 240 3118 Fax (+1) (0) 530 273-2769 Email ussupport@solaredge.com