Technical Specifications

Similar documents
Matt Dann Cultural Centre

THE STREET THEATRE. Technical Specifications

2017 TECHNICAL SPECIFICATIONS

Latrobe Performing Arts Centre

Queensland Performing Arts Centre

Technical Specifications

Dr JOHN GALLAGHER CONCERT CHAMBER

John Leslie Theatre. Technical Specifications. Updated July 2018

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

CENTRE FOR PERFORMING ARTS

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

DEREHAM MEMORIAL HALL

Esso BHP Billiton Wellington Entertainment Centre

Technical Specification

Technical Specifications Updated 01/10/2017. Stage

RPAC REDLANDS PERFORMING ARTS CENTRE

Technical Data Sheet

MONASH University Academy of Performing Arts

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Technical Specification

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Theatre Technical Specifications

Main Stage Technical Specs - Hall #2

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Summary. Access and Parking

Don Russell Performing Arts Centre

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Mildura Arts Centre. Mildura Arts Centre Theatre. Technical Specifications. Updated 23/6/06

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Technical Specification Pavilion Dance

CHELSEA THEATRE. Technical Specifications

Monash Academy of Performing Arts

Monash University Academy of Performing Arts

Yan Yean Theatre Technical Specifications

INFORMATION FOR VISITING COMPANIES

New Theatre Royal Lincoln Technical Information

JERWOOD VANBRUGH THEATRE

Technical Specification Ardhowen Theatre

Technical Pack. Attenborough Arts Centre

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

Technical Information

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Theatre Technical Specifications

Orange Civic Theatre

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical Specification

Visy Theatre technical information and general specifications 2019

Technical Specification for the Alley Theatre, Strabane

Access to back stage is off Fletcher St on the eastern side of the building

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

Technical specifications Main theatre. Sound

A red velvet front of house curtain closes off the main stage leaving only the apron visible to the audience.

THEATRE Technical Specifications

HIRE AND TECHNICAL INFORMATION

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Cornerstone Technical Specifications 2018 / V1

D A R E B I N A R T S & E N T E R T A I N M E N T C E N T R E

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Technical Specifications

The Haymarket Basingstoke Technical Specifications

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

ISLAND HALL TECHNICAL INFORMATION

Technical Specifications

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Roundhouse Theatre. Roundhouse Theatre. Technical Specifications. Updated 28/4/2008

Stage. Get In & Parking

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Darebin Arts & Entertainment Centre. Theatre

UNIVERSITY CONCERT HALL. Technical Specification

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Barney Simon Theatre Technical Specifications

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

ROSE THEATRE BASEMENT

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Pleasance London Main House Visiting Company Information Pack May 2017

Theatre Technical Specification

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Technical Specifications Nov 2016

BECKETT THEATRE TECHNICAL INFORMATION & GENERAL SPECIFICATIONS 2014 PLEASE DIRECT ALL ENQUIRIES TO THE OPERATIONS MANAGER:

TECHNICAL PACKAGE.

Blue Bridge Repertory Theatre Technical Specifications

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

THEATRE EQUIPMENT DECEMBER 2017

Patriots Theater at the War Memorial Technical Data

Main House Technical Specification

Technical Director of Production Andrew Quick Ext 252

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Alexander Theatre. Technical Specifications. Monash University VIC enter via Wellington Road

Downtown Arts Center Tech Packet. General Information

1

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Arlington Arts Tech Spec 2018

Gosford City Council

TOWER THEATRE TECHNICAL INFORMATION & GENERAL SPECIFICATIONS 2014 PLEASE DIRECT ALL ENQUIRIES TO THE OPERATIONS MANAGER:

Monash Academy of Performing Arts (MAPA) Alexander Theatre. Technical Specifications

Jane Mallet Theatre Technical Specifications

Transcription:

Technical Specifications Lighthouse Studio Version 4.1 13/05/16 Technical Services Coordinator: Xavier Dannock Phone number: 03 5559 4988 Mobile Number: 0402 973 030 Email address: xdannock@warrnambool.vic.gov.au Venue: Phone number: 03 5559 4999 Website: http://www.lighthousetheatre.com.au/ Additional contact details are located on the final page Generated from the APACA Technical Specifications Template. For more details visit www.apaca.com.au

STAGE Brief Stage Description: Black Box style space with polished parquetry flooring and variable seating bank positions. No screwing into floor is permitted under any circumstance. Space distributed load limit 7.5Kpa Stage point load limit Discuss with venue Stage rake No Seating Bank: Acromat retractable seating bank with 140 seats total. It can be moved to multiple configurations within the space. Can also be stored against a wall if not being used. Contact venue to discuss seating bank position Seating capacity with additional Floor rows installed 157 (max capacity with seating bank) Seating capacity without Additional floor rows installed 106 Drapery: Venue has drape stock that skirts the bulkheads of the entire space on tracking. There are no traditional legs or borders in the space. Discuss drapery requirements with Technical Coordinator. Access Equipment: Elevated Work Platform Haulotte Quick Up 11 (Push Around Vertical Lift) Maximum reach is 11m EWP is not located in space and is shared with theatre. EWP Restrictions Outriggers must be used at all times, one staff member to be located at base whilst in use. Ladders 1 x 3.8m Platform Staging Units: 10x Power Stage Podium Series Units (shared with Theatre) 1m wide by 2m long. Legs available at 400mm (with wheels) and 600mm (with feet). Carpeted tops. 2x 400mm step units and 1x 600mm step unit available. Load limit: 500kg distributed, 150kg point load. Note: Using more than 4 units may incur a charge for moving between venues. Page 2 of 14

Stage Covers: Style Dimensions Colour Black Vinyl 4x 15m x 1.6m Strips Black (please note this is not branded Tarkett, it is just a black floor vinyl) Loading Dock: Access Via front doors of building for all small to medium items. A standard public lift is available to move equipment to upper level. Large set and props must be taken via ramps which are 80m long at 10 degree gradient. Any item that will not fit through a standard door needs to be discussed with the Technical Coordinator prior to bump in. Restrictions / Obstructions 80m of ramping, 1 x 20mm obstruction protruding from floor of external door Additional Rigging Notes Fire sprinklers currently limit ability to rig in the roof. Please contact Technical Coordinator to discuss Fixing points are available around the space on the bulkhead for fixing booms or items less than 100kg to wall. Height to rigging bars is 3.9m. Floor to ceiling is 4m. Staging Notes: All flown items must be rigged with rated equipment and is subject to approval by a venue representative. Limited rigging gear available in house. Including lifting straps, shackles and pulleys. Page 3 of 14

Bar height 3.9m South End of Venue Bar distance from Bulkhead wall Page 4 of 14

Control: Lighting desk ETC Element Control channels 2 x 512 Signal output Signal distribution 5-Pin DMX Remote riggers available onstage LSC DMX splitter - splitting to various points through the room (flexible). Room only has one universe of DMX available as standard. No Dimmer Racks: Total Dimmers Dimmer Locations 2.4Kw Dimmer Racks 48 @ 2.4kW Located in separate room adjacent to theatre 4 LSC i-pro Racks Total dimmers @ 2.4kw per dimmer 48 (Extra dimmers may be available on request) House Lights: Independent control Control positions Fade time adjustable Controllable via Desk or Dynalite system (Dynalite is on wall, not movable) Next to all entrance doors or from LX Desk (DMX only) Dynalite: No; DMX: Yes Stage Luminare: Fixtures in BOLD are assigned to venue as standard NO fixtures are rigged as standard we rig to show needs All other fixtures are from the Main Theatre, Available on consultation Profiles Make Model Angle Detail / Accessories Watt Total Selecon Pacific 23/50 With Gobo Holders 1000w 10 Selecon Axial Acclaim 18/34 600w 14 Selecon Axial Acclaim 22/44 600w 20 Strand SL Zoom Spots 650w 12 Fresnel s Make Model Detail / Accessories Watt Total Selecon Acclaim Fresnel All with Doors 650w 38 Selecon Rama Fresnel All with Doors 1200w 42 Page 5 of 14

Movers Make Model Control Channels Detail / Accessories Watt Total Robe 300 Spot 24 3-Pin Only 500w 2 Additional Lighting: Item Make Model Detail / Accessories Watt Total Robe Hazer 400FT Cracker 1000w 1 Swefog Smoke Machine T26 1200w 1 Mirror Ball 20 With motor 1 Birdies 240v 12 Lighting stock availability needs to be confirmed with venue. Please speak to the Technical Coordinator to discuss. Page 6 of 14

Power: 3 Phase Outlets 1x 40A on South Wall 1x 40A on North Wall 1x 40A on West Wall 2x 40A in attached Comm s Room Cabling: 240v Extension Cable There is a moderate stock of leads in the venue, more can be made available with prior arrangement. Looms May be available on request 3 phase Extensions None Lighting Notes: This venue has NO standard rig. All Lighting plans must be submitted to the theatre 10 business days prior to bump in due to rigging restrictions in the grid. We rig to show requirements. Page 7 of 14

AUDIO Control Positions: Control Room N/A Auditorium Several seats can be removed from the top two rows of the seating bank to make a 2m wide area. Most operation occurs from either side of the flexible seating bank Removable Seats 12 Control & Amplification: Primary Mixer Allen & Heath ZED428 Mixing Console Secondary Mixer Midas M32 Digital console (main theatre main console, may not be available) Amplifiers N/A EQ 1x ARX dual 32ch Graphic EQ Other EQ available: 1x Klark Teknik DN360 1/3 Octave Dual Channel Graphic EQ (1 normally used for FOH L/R EQ) 1x ARX EQ60 1/3 Octave Dual Channel Graphic EQ 4x Sound Developments EQ27 Single Channel EQ (old) FX 1x Lexicon MX200 dual channel FX unit Other FX available: 1x TC Electronic M350 FX Unit 1x Yamaha REV500 FX Unit Compression / Limiter / Gates 2x 2 channel DBX 266xs Compressor/Gate units Speakers: FOH Speakers 2 x QSC K8 Series FOH Speakers, powered 105* throw. Mounted horizontally on 2 x QSC KSub not generally needed in this space, however may be available if not in use in main theatre. Foldback 4 x Jolly 8" + 1" 2way 150w+50w Low Profile Speakers All available via arrangement with venue Page 8 of 14

Playback: Item Make Model Detail Total CD Player Tascam CD200 Single Professional CD player 1 Microphones: Make Model Detail / Accessories Use Total Shure Goose Neck Lectern Mic 2 Shure Beta58 6 Neumann KM100 Condenser 2 Neumann KMI Condenser 3 Neumann KMR82i Shotgun Mic 2 Beyer Dynamic Switched Shout Mic 1 Crown P2M 3 Shure SM57 4 Shure PGMK Drum Mic Kit 1 Sennheiser XS Wireless 1x handheld wireless mic Permanent in venue 1 Accessories: Item Model Detail / Accessories Total McLelland PDB-100 DI 4 Behringer UltraDI 4 Line Patching: Venue has over 100 lines of Balanced XLR patching. Exact positions available upon request. Cabling: Audio Cable The theatre has a good stock of cable to accommodate the venue s equipment Multicore 1 x 24CH Drop Box (No returns) 2 x 12CH Drop Box (No returns) 1 x 20CH XLRM XLRF More are available if requested in advance (Hire fee s apply) Audio Notes: All audio equipment lives in the main theatre. Use of equipment needs to be discussed with Technical Coordinator Soundweb used for sound relay throughout the venue. Contact venue for more specific information. More equipment available from local suppliers, hire charges apply Page 9 of 14

AUDIO VISUAL Projection Room: None Projectors: Optoma EW865 6000 ANSI lumens, DLP, single lamp, 2000:1 contrast ratio, WXGA 16:9 resolution Standard Lens only Screens: Projection Screen Front Projection screen 135 diagonal, 16:10 ratio Additional Screens Rear Projection (QFold Screen) Screen dimensions 7x10ft AV Playback Equipment: Various equipment available - Contact Venue Projector Rigging Points: Various rigging points available including LX bars, Contact Venue Cabling: The theatre has a good stock of coaxial and RCA cable to accommodate the venue s own equipment. Audio Visual Notes: Over 20 BNC tie lines throughout the venue, with 1x 8 way distribution amplifier available Free to Air TV available throughout the venue. Cat5 VGA converter available for use with the projector Page 10 of 14

BACKSTAGE Communications: Stage Managers Desk Not available as standard, Please contact venue if requiring one. Talkback Master Unit Total sub stations 4 Total headsets 4 Jands Clearcom. Radio Units In-house None in Studio space Talkback patching located at: Various points throughout the venue, please contact us to discuss specific requests Paging / Show relay Paging to dressing rooms not available as standard, Please contact Venue Stage Monitor TV s set up in green room, extra monitors available on request. Camera NOT rigged as standard. Contact venue if required Q Light System In house Q light system available Number of units No N/A Page 11 of 14

Dressing Rooms: Meeting room is the designated dressing room space for this venue. Laundry / Wardrobe: Washing Machines Dryers Drying rooms Iron / ironing board 1 Clothes racks 2 Production Facilities: 10kg top loader Not always accessible 7kg Not always accessible N/A Production Desk Tables available on request Production Office Not Available Phone Phone available in the meeting room Fax N/A Internet access Yes, Contact venue in advance to request usage Greenroom: Tea / Coffee facilities Fridge / freezer Microwave Running water Yes Yes Small Bar Fridge in meeting room No Yes Stage Door: Access Venue does not have a stage door, access is through main foyer unless other arrangements are made ADDITIONAL FACILITIES & INFORMATION Orchestral: 20+ Music stands available upon request Page 12 of 14

VENUE: Venue Contacts: Venue Address 185 Timor St (Cnr Liebig St), Warrnambool, Victoria, Australia, 3280 Venue Postal Address PO Box 198, Warrnambool, Victoria, Australia, 3280 Venue Website www.lighthousetheatre.com.au Staff Contacts: Service Manager Michael Frawley Phone Number 03 5559 4887 Email Address Technical Services Coordinator Xavier Dannock Phone Number 03 5559 4988 Mobile 0402 973 030 Email Address mfrawley@warrnambool.vic.gov.au xdannock@warrnambool.vic.gov.au Venue & Marketing Coordinator Amanda Kenneally Phone Number 03 5559 4886 Email Address Box Office Phone Number 5559 4999 Email Address akenneally@warrnambool.vic.gov.au lighthouse@warrnambool.vic.gov.au (Direct FOH Queries to V&MC) Venue Plans: Venue Plan Available Yes, DWG copy s can be e-mailed at request. Contact Technical Coordinator Venue Section Available Yes, DWG copy s can be e-mailed at request. Contact Technical Coordinator Page 13 of 14

Venue Information: The Lighthouse Theatre operates a Main Theatre, a smaller multi-purpose Studio Space and a Meeting Room. The Main Theatre is a proscenium arch theatre seating 583. The Studio has flexible tiered seating for 140 for performances but can also be used for conferences, wedding receptions and dinner dances. The Meeting Room is designed for round table, classroom or theatre style meetings/events for up to 50 people. This room also doubles as the Dressing Room for Studio performances. We are extremely fortunate at the Lighthouse Theatre to have a dedicated team of Volunteers to assist with ushering, preparing hot beverages and administration tasks. A core team of 6 people run the Centre, which is owned and operated by Warrnambool City Council. There are limited casual staff available for production work. The venue is located in the heart of the Warrnambool CBD and within walking distance of Restaurants, Accommodation houses, Banks and Supermarkets. Page 14 of 14