Selection guide siemens.com/sirius-modular-system

Similar documents
Contactors and Contactor Assemblies

Accessories Order No. Page Individual parts Order No. Page K1 1) K3 2) K2 2) 14 Auxiliary switch block, front. 3/105 terminals.

TeSys circuit-breakers

Bulletin 190 IEC Modular Starter System

AS09..S 3-pole Contactors - Spring Terminals

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Features XT SC 012 B B A

XT IEC Power Control Combination Motor Controllers

Fastbus Combination Starters. SIRIUS 3RA11 Fastbus Non-Reversing Combination Starters,

Features XT SC 012 B B A

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Spare Parts, Accessories, Consumable Material for Older Design Recorders

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Series CT7N Bimetallic Overload Relays

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Bulletin 509 Full Voltage

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

Bulletin 100-G IEC Contactors

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Magnetic and Hydraulic-Magnetic Circuit Breaker

Bulletin 190 Compact. Combination Starters

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Bulletin 305 AC Starters

Bulletin 150, 154 Softstarters Quick Selection Table

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

Siemens AG Safety along the complete line: SIRIUS 3SE7 cable-operated switches SIRIUS. Answers for industry.

Bulletin 100-G IEC Contactors

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Pushbutton Units and Indicator Lights

Generator protection relay

Your order must include: cat. no. of the miniature contactor specified with coil voltage code and, if required, cat. no. of any accessories

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

3-pole contactors for standard applications

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Circuit-Breakers for Motor Protection Series 8523/8

XT Line Replacement Coils 16.1 NEMA Contactors and Starters Freedom Line... A200 Line IEC Contactors and Starters XT Line...

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Kuhnke Technical Data. Contact Details


Datasheet - SRB301LC 24VAC/DC

Selection table SITOP power supplies

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Power Circuit of a UL508A Panel. Typical UL489 Application

Data Sheet Definite Purpose Contactors Ex9CK Series

SIMATRIX NEO V2 Modular Video Matrix

Accessories. EasyPact and Vigi CVS100/160/ short LV long LV Steel connectors 1 x (1.5 to 95 mm²) ; y 160 A Set of 3 LV429242

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

llen-bradley 194R-HM4-NFPA3

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Ordering details. Approval. Classification

Bulletin 500 Top Wiring For Motor Loads

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

3AH3 Vacuum Circuit-Breakers

SQM40/41 Actuators for air and gas dampers

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

SOFTLINK 300. Modules Specifications. Reference Manual

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

AF-300 E11 Adjustable Frequency Drive

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Minicontactorrelay,2NO/2NC,DCoperated

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

Nessie Coils for VDH and VDHT valves

High performance circuit breakers

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) XT RE C 10 B 22 AD

Single Point Flow Monitor SW118 SW119

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

APPLICATIONS. Automatic warehouse. Trasportation lines

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

Electromechanical Relays

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

APPLICATIONS. Automatic warehouse. Trasportation lines

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Transcription:

SIRIUS modular system Selection guide siemens.com/sirius-modular-system

Everything for the control cabinet: SIRIUS modular system Efficiently combined Advantages at a glance: Load feeders: easy to implement up to 250 kw/ 400 V from standard devices with motor starter protectors for motor protection, contactors, overload relays and monitoring relays Modular design: a host of combination options in standardized design Variants and sizes: 7 compact sizes Installation: quick and easy installation of feeders thanks to link modules Accessories: low variance with uniform accessories Connection types: screw and spring-type terminals available IE3/IE4 ready: familiar reliability even when changing over to IE3/IE4 motors Application monitoring: mountable monitoring relay for simple application monitoring beyond the motor Possible combinations depending on requirement: Load feeders: Direct start (p. 3 5) Motor starter protector for motor protection Link module Contactor Load feeders: Soft start, solid-state contactors (p. 6 7) Motor starter protector for motor protection Link module Monitoring relays (up to S2) or overload relays 3RW30 or 3RW40 soft starters Solid-state contactors (S00 and S0) Thermally delayed Electronic Analogically Digitally For frequently switching AC drives on and off, our motor starter protectors can also be combined with solid-state contactors or reversing contactors and an overload relay. 2

Load feeders for direct start Load feeders start loads by a combination of protection and switching functions. A load feeder assembly consisting of motor starter protector, contactor, overload relay or monitoring relay offers suitable combinations for every application. Three-phase motor Current Power [kw] Mot. starter prot. Contactors Overload relays Monitoring relays Solenoid Aux. Electronic voltage switch S00, 45 mm Thermally delayed E Meas. 2-phase Basic, analogically Supply voltage 24 240 V AC/DC 3-phase Standard, digitally 0.09 0.32 0.22 0.32 3RV2011-0DA 0 3RU2116-0D 0 0.1 0.4 3RB3016-1R 0 0.12 0.5 0.35 0.5 3RV2011-0FA 0 3RU2116-0F 0 0.18 0.63 0.45 0.63 3RV2011-0GA 0 3RU2116-0G 0 0.32 1.25 3RB3016-1N 0 0.25 1 0.7 1 3RV2011-0JA 0 3RU2116-0J 0 0.37 1.25 0.9 1.25 3RV2011-0KA 0 230 V AC, 50/60 Hz 1NO 3RT2015- AP01 3RU2116-0K 0 0.55 1.6 1.1 1.6 3RV2011-1AA 0 1NC 3RT2015- AP02 3RU2116-1A 0 *1 0.75 2 1.4 2 3RV2011-1BA 0 24 V DC 1NO 3RT2015- BB41 3RU2116-1B 0 1 4 3RB3016-1P 0 1.1 3.2 2.2 3.2 3RV2011-1DA 0 1NC 3RT2015- BB42 3RU2116-1D 0 1.5 4 2.8 4 3RV2011-1EA 0 3RU2116-1E 0 2.2 6.3 4.5 6.3 3RV2011-1GA 0 3RU2116-1G 0 3 8 5.5 8 3RV2011-1HA 0 3RU2116-1H 0 4 10 7 10 3RV2011-1JA 0 230 V AC, 50/60 Hz 1NO 3RT2016 AP01 3RU2116-1J 0 3 12 3RB3016-1S 0 *1 1NC 3RT2016 AP02 24 V DC 1NO 3RT2016 BB41 1NC 3RT2016- BB42 5.5 12.5 9 12.5 3RV2011-1KA 0 230 V AC, 50/60 Hz 1NO 3RT2017- AP01 3RU2116-1K 0 1.6 16 3RR2141- AW30 3RR2241- FW30 *1 1NC 3RT2017- AP02 24 V DC 1NO 3RT2017- BB41 1NC 3RT2017- BB42 7.5 16 11 16 3RV2011-4AA 0 230 V AC, 50/60 Hz 1NO 3RT2018- AP01 3RU2116-4A 0 4 16 3RB3016-1T 0 *1 1NC 3RT2018- AP02 24 V DC 1NO 3RT2018- BB41 1NC 3RT2018- BB42 Spring-type term. to 32 A: 2 Spring-type term.: 2 Screw terminals: B Spring-type term.: C Screw terminals: B Spring-type term.: E Spring-type term.: 2 3

Three-phase motor Mot. starter prot. Contactors Overload relays Monitoring relays Solenoid Aux. Thermally Electronic 2-phase Basic, voltage switch delayed analogically E 3-phase Standard, digitally Current Power Meas. Supply voltage 24 240 V AC/DC [kw] S0, 55 mm 7.5 16 10 16 3RV2021-4AA 0 230 V AC, 50 Hz 1NO+1NC 3RT2025- AP00 3RU2126-4A 0 *2 7.5 20 13 20 3RV2021-4BA 0 24 V DC 1NO+1NC 3RT2025- BB40 3RU2126-4B 0 11 22 16 22 3RV2021-4CA 0 230 V AC, 50 Hz 1NO+1NC 3RT2026- AP00 3RU2126-4C 0 *2 11 25 18 25 3RV2021-4DA 0 24 V DC 1NO+1NC 3RT2026- BB40 3RU2126-4D 0 15 28 23 28 3RV2021-4NA 0 230 V AC, 50 Hz 1NO+1NC 3RT2027- AP00 3RU2126-4N 0 10 40 3RB3026-1V 0 4 40 3RR2142- AW30 3RR2242- FW30 *2 15 32 27 32 3RV2021-4EA 0 24 V DC 1NO+1NC 3RT2027- BB40 3RU2126-4E 0 18.5 36 30 36 3RV2021-4PA 1 0 230 V AC, 50 Hz 1NO+1NC 3RT2028- AP00 3RU2126-4P 0 *2 18.5 40 34 40 3RV2021-4FA 1 0 24 V DC 1NO+1NC 3RT2028- BB40 3RU2126-4F 0 Spring-type term. to 32 A: 2 Spring-type term.: 2 Screw terminals: B Spring-type term.: C Screw terminals: B Spring-type term.: E Spring-type term.: 2 S2, 55 mm 18.5 36 28 36 3RV203-4PA10 230 V AC, 50 Hz 1NO+1NC 3RT2035- AP00 3RU2136-4EB0 *3 18.5 40 32 40 3RV203-4UA10 20 33 V AC/DC 1NO+1NC 3RT2035- NB30 3RU2136-4FB0 22 45 35 45 3RV203-4VA10 230 V AC, 50 Hz 1NO+1NC 3RT2036- AP00 3RU2136-4GB0 *3 22 52 42 52 3RV203-4WA10 20 33 V AC/DC 1NO+1NC 3RT2036- NB30 3RU2136-4HB0 30 59 49 59 3RV203-4XA10 230 V AC, 50 Hz 1NO+1NC 3RT2037- AP00 3RU2136-4QB0 *3 30 65 54 65 3RV203-4JA10 20 33 V AC/DC 1NO+1NC 3RT2037- NB30 3RU2136-4JB0 37 73 62 73 3RV203-4KA10 230 V AC, 50 Hz 1NO+1NC 3RT2038- AP00 3RU2136-4KB0 *3 37 80 70 80 3RV203-4RA10 20 33 V AC/DC 1NO+1NC 3RT2038- NB30 3RU2136-4RB0 S3, 70 mm 22 50 36 50 3RV204-4HA10 230 V AC, 50 Hz 1NO+1NC 3RT2045- AP00 3RU2146-4HB0 30 63 45 63 3RV204-4JA10 *4 20 33 V AC/DC 1NO+1NC 3RT2045- NB30 3RU2146-4JB0 37 75 57 75 3RV204-4KA10 3RU2146-4KB0 45 84 65 84 3RV204-4RA10 *4 230 V AC, 50 Hz 1NO+1NC 3RT2046- AP00 20 33 V AC/DC 1NO+1NC 3RT2046- NB30 3RU2146-4LB0 45 93 75 93 3RV204-4YA10 230 V AC, 50 Hz 1NO+1NC 3RT2047- AP00 *4 45/55 100 80 100 3RV204-4MA10 20 33 V AC/DC 1NO+1NC 3RT2047- NB30 3RU2146-4MB0 20 80 3RB3036-1W 8 80 3RR2143- AW30 3RR2243- FW30 32 115 3RB3046-1X Standard switching cap. 65 ka: 1 Increased switching cap. 100 ka: 2 Spring-type term. in aux. circuit: 3 Contactor mounting Screw terminals: B 0 Spring-type term.: D 0 Straight-through transf. Screw term.: W1 Spring-type term.: X 1 Spring-type term.: 3 Necessary accessories: link module from motor starter protector to contactor Size Screw terminals Spring-type terminals (only for S00 and S0) S00 up to max. 32 A AC/DC *1 3RA1921 1DA00 3RA2911-2AA00 S0 up to max. 32 A AC *2 3RA2921-1AA00 3RA2921-2AA00 S0 up to max. 32 A DC *2 3RA2921-1BA00 3RA2921-2AA00 S2 up to max. 65 A AC/DC *3 3RA2931 1AA00 S3 AC/DC *4 3RA1941-1AA00 4

Accessories 3RV motor starter protectors/circuit breakers Size Mountable Design Screw Spring-type accessories terminals terminals S00, S0, Transverse 1CO 3RV2901-1D S2, S3 auxiliary switch 1NO+1NC 3RV2901-1E 3RV2901-2E Lateral (left) 1NO+1NC 3RV2901-1A 3RV2901-2A auxiliary switch 2NO 3RV2901-1B 3RV2901-2B Signaling switch 1NO+1NC 3RV2921-1M 3RV2921-2M Shunt 210... 240 V AC 3RV2902-1DP0 3RV2902-2DP0 release 24 V DC 3RV2902-1DB0 3RV2902-2DB0 Undervoltage 230 V AC 3RV2902-1AP0 3RV2902-2AP0 release 24 V DC 3RV2902-1AB4 Door-coupling rotary op. mech. Black 3RV2926-0B 130 mm shaft Red/yellow 3RV2926-0C S00, S0 Molded-plas. encl. 54 mm wide 3RV1923-1CA00 f. surf. mounting 72 mm wide 3RV1923-1DA00 S2 IP55, black 82 mm wide 3RV1933-1DA00 S00, S0 Molded-plas. encl. 54 mm wide 3RV1923-1FA00 f. surf. mounting 72 mm wide 3RV1923-1GA00 S2 IP55, EMERG. STOP 82 mm wide 3RV1933-1GA00 3RV29 infeed system For sizes S00 and S0, the simplest method is to connect the components via the associated SIRIUS 3RV29 infeed system in each case. 3-phase busbar for 2 motor starter protectors size S00/S0 With infeed on the left (incl. 3RV2917-6A end cover) With infeed on the right (incl. 3RV2917-6A end cover) For system expansion (incl. 3RV2917-5BA00 expansion plug) Plug-in connectors for contact with motor starter protectors Size S00 Screw terminals Spring-type terminals Size S0 Screw terminals Spring-type terminals Contactor base for contactors size S00, S0 3RV2917-1A 3RV2917-1E 3RV2917-4A 3RV2917-5CA00 3RV2917-5AA00 3RV1927-5AA00 3RV2927-5AA00 3RV2927-7AA00 Contactors Auxiliary switch Screw Spring-type blocks, on front terminals terminals S00, S0, S2, S3 1NC 3RH2911-1HA01 3RH2911-2HA01 1NO+1NC 3RH2911-1HA11 3RH2911-2HA11 2NO+2NC 3RH2911-1HA22 3RH2911-2HA22 1NO 3RH2911-1HA10 3RH2911-2HA10 2NO 3RH2911-1HA20 3RH2911-2HA20 Surge suppressors Size S00 Plug-in Without LED Varistor 3RT2916-1BD00 With LED 127... 240 V AC 3RT2916-1JL00 Without LED RC element 127... 240 V AC 3RT2916-1CD00 Without LED Suppr. diode 24 V DC 3RT2916-1DG00 Size S0 Without LED Varistor 3RT2926-1BD00 With LED 127... 240 V AC 3RT2926-1JL00 Without LED RC element 127... 240 V AC 3RT2926-1CD00 Without LED Diode assy. 24 V DC 3RT2926-1ER00 Size S2 Without LED Varistor 3RT2936-1BD00 With LED 127... 240 V AC 3RT2936-1JL00 Without LED RC element 127... 240 V AC 3RT2936-1CD00 Size S3 Without LED Varistor 3RT2936-1BD00 With LED 127... 240 V AC 3RT2936-1JL00 Without LED RC element 127... 240 V AC 3RT2946-1CD00 Coil terminal module Size S0 S3 Connection 3RT2926-4RB11 from below Size S0 3RT2926-4RB12 Overload relays and monitoring relays Terminal supports f. stand-alone inst. Screw terminals Spring-type terminals S00 3RU2916-3AA01 3RU2916-3AC01 S0 3RU2926-3AA01 3RU2926-3AC01 S2 3RU2936-3AA01 S3 3RU2946-3AA01 Wiring kit for contactors Reversing contactor assembly S00 3RA2913-2AA1 3RA2913-2AA2 S0 3RA2923-2AA1 3RA2923-2AA2 (main circuit only) S2 3RA2933-2AA1 3RA2933-2AA2 (main circuit only) S3 3RA2943-2AA1 3RA2943-2AA2 (main circuit only) Contactor assy. f. wye-delta start S00 3RA2913-2BB1 3RA2913-2BB2 S0 3RA2923-2BB1 3RA2923-2BB2 (main circuit only) S2 3RA2933-2BB1 3RA2933-2BB2* S3 3RA2943-2BB1 3RA2943-2BB2* *main circuit only, set of cables for auxiliary circuit Wye-delta function module, plug-in Comprising one basic module and two coupling modules, rated control supply voltage 24... 240 V AC/DC, time setting 0.5... 60 s (10, 30, 60 s selectable) S00, S0, S2, S3 3RA2816-0EW20 6 1 6 5 3b 3a 7 2 4 8 3RV29 infeed system 1 3-phase busbar with infeed 2 3-phase busbar for system expansion 3a Expansion plug 3b Extra-wide expansion plug 4 End cover 5 Terminal block for device infeed 6 Plug-in connector 7 Contactor base 8 Terminal block 5 2 1 4 3 Mountable accessories for 3RV motor starter protectors 1 Transverse auxiliary switch 2 Lateral auxiliary switch with 2 contacts 3 Shunt release (cannot be used for 3RV21 motor starter protector) 4 Undervoltage release without/with leading contacts (cannot be used for 3RV21 motor starter protector) 5 Signaling switch (cannot be used for 3RV27 and 3RV28 circuit breakers) 5

Load feeders: Soft starters, solid-state contactors Soft starters for current-limiting and torque-lim. starts reduce wear on the mech. power-transm. elements of the machine, relieve load on the power supply system and protect the line efficiently against high switch-on peak currents by means of reduced current consumption. Solid-state contactors are intended for frequently switching AC drives up to 7.5 kw on and off and for reversing up to 3.0 kw. The devices are constructed with complete insulation and can be mounted directly on motor starter protectors. Three-phase motor Mot. starter prot. 3RW30 soft starters Oper. voltage 3 x 200 480 V AC Starts/h Rated normal operat. starting current 3RW40 soft starters Oper. voltage 3 x 200 480 V AC Starts/h Rated normal operat. starting current Solid-state contactors Oper. voltage 48 480 V AC Rated operat. current Solid-state reversing contactors Oper. voltage 48 480 V AC Rated operat. current Current Power [kw] S00, 45 mm S00, 45 mm S0, 45 mm 0.25 1 0.7 1 3RV2011-0JA 0 0.37 1.25 0.9 1.25 3RV2011-0KA 0 0.55 1.6 1.1 1.6 3RV2011-1AA 0 *2 150 3.6 3RW3013- BB 4 0.75 2 1.4 2 3RV2011-1BA 0 3.8 3RF3403-1BD 4 1.1 3.2 2.2 3.2 3RV2011-1DA 0 *2 5.2 3RF3405- BB 4 1.5 4 2.8 4 3RV2011-1EA 0 5.4 3RF3405-1BD 4 1.5 5 3.5 5 3RV2011-1FA 0 64 6.5 3RW3014- BB 4 36 12.5 3RW4024- BB 4 2.2 6.3 4.5 6.3 3RV2011-1GA 0 7.4 3RF3410-1BD 4 3 8 5.5 8 3RV2011-1HA 0 9.2 3RF3410- BB 4 4 10 7 10 3RV2011-1JA 0 35 9 3RW3016- BB 4 5.5 12.5 9 12.5 3RV2011-1KA 0 62 12.5 3RW3017- BB 4 12.5 3RF3412- BB 4 7.5 16 11 16 3RV2011-4AA 0 45 17.6 3RW3018- BB 4 15 25 3RW4026- BB 4 S0, 45 mm S0, 45 mm 7.5 16 11 16 3RV2021-4AA 0 16 3RF3416- BB 4 7.5 20 14 20 3RV2021-4BA 0 15 25 3RW3026- BB 4 11 22 17 22 3RV2021-4CA 0 *2 11 25 20 25 3RV2021-4DA 0 15 28 23 28 3RV2021-4NA 0 16 32 3RW3027- BB 4 16 32 3RW4027- BB 4 15 32 27 32 3RV2021-4EA 0 18.5 36 30 36 3RV2021-4PA 1 0 12 38 3RW3028- BB 4 12 38 3RW4028- BB 4 18.5 40 34 40 3RV2021-4FA 1 0 Spring-type term. to 32 A: 2 Spring-type terminals: 2 Control supply voltage 24 V AC/DC: 0 110 230 V AC/DC: 1 Spring-type terminals: 2 Control supply voltage 24 V AC/DC: 0 110 230 V AC/DC: 1 Spring-type terminals: 2 Control supply voltage 24 V DC: 0 110 230 V AC, 50/60 Hz: 2 Spring-type terminals: Control supply voltage 24 V DC: 0 110 230 V AC, 50/60 Hz: 2 6

Three-phase motor Mot. starter prot. 3RW30 soft starters without overload protection Rated operational current 3RW40 soft starters with overload protection Current Power [kw] S2, 55 mm 18.5 36 28 36 3RV203-4PA10 18.5 40 32 40 3RV203-4UA10 22 45 35 45 3RV203-4VA10 *3 45 3RW3036-1BB 4 3RW4036-1BB 4 22 52 42 52 3RV203-4WA10 30 59 49 59 3RV203-4XA10 30 65 54 65 3RV203-4JA10 *3 63 3RW3037-1BB 4 3RW4037-1BB 0 37 73 62 73 3RV203-4KA10 37 80 70 80 3RV203-4RA10 *3 72 3RW3038-1BB 4 3RW4038-1BB 4 S3, 70 mm 22 50 36 50 3RV204-4HA10 30 63 45 63 3RV204-4JA10 *4 80 3RW3046-1BB 4 3RW4046-1BB 4 37 75 57 75 3RV204-4KA10 45 84 65 84 3RV204-4RA10 45 93 75 93 3RV204-4YA10 *4 106 3RW3047-1BB 4 3RW4047-1BB 4 45/55 100 80 100 3RV204-4MA10 3RW30 soft starter The compact 3RW30 soft starter can be used in almost every standard application up to 55 kw. is made via two potentiometers and can thus be implemented conveniently and easily. 3RW3 state diagram U U N U S 3RW30 3-phase motor t R on t Standard switching cap. 65 ka at 400 V: 1 Increased switching cap. 100 ka at 400 V: 2 24 V AC/DC: 0 110 230 V AC/DC: 1 24 V AC/DC: 0 110 230 V AC/DC: 1 Necessary accessories: link modules from motor starter protector to soft starter / solid-state device Size Screw terminals Spring-type terminals only for S00, S0 with soft starters S00 *2 3RA2921-1BA00 3RA2911-2GA00 S0 up to max. 32 A *2 3RA2921-1BA00 3RA2921-2GA00 S2 up to max. 65 A *3 3RA2931 1AA00 S3 *4 3RA1941-1AA00 3RW40 soft starter The 3RW4 additionally has potentiometers for soft ramp-down, current limiting and motor overload protection. Integrated intrinsic device protection and motor protection functions offer additional advantages over the 3RW3. 3RW4 state diagram Advantages of the soft starters: Reduced mechanical and electrical load Space and cost savings thanks to compact design Fast and easy commissioning Matched with the SIRIUS modular system U U N U S 3RW40 3-phase motor t R on t R off t 7

Published by Siemens AG 2017 Digital Factory Control Products P.O. Box 23 55 90713 Fuerth Germany Article No. DFCP-T10133-00-7600 Printed in Germany Dispo 18101 TH 411-170142 BR 0717 Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the concluded contract.