Operation Manual for. SCU1 Signal Conditioning Unit

Similar documents
Innovation in Magnetic Measuring Instruments. Operation Manual for. Mag648 and Mag649 Low Power Three-Axis Magnetic Field Sensors.

Innovation in Magnetic Field Measuring Instruments. Magnetometer Power Supplies

Innovation in Magnetic Field Measuring Instruments. Magnetometer Power Supplies

INNOVATION IN MAGNETICS DS3434/5. Mag612. Miniature Three-Axis Fluxgate Probe.

PicoScope 4000 Automotive PC Oscilloscopes

PicoScope 3000 Series Automotive User guide

KHT 1000C HV-Probe Calibrator. Instruction Manual

DSP 18 Sub active subwoofer. user manual

PicoScope 2000 Series PC Oscilloscopes

DISTRIBUTION AMPLIFIER

SATRI AMPLIFIER AMP-51R. Owner s Manual

RoHS. Atma-Sphere Music Preamplifier. model P-2 OWNER'S MANUAL. Please study this document carefully before using equipment

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Achat 115 Sub A active subwoofer. user manual

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

Noise Detector ND-1 Operating Manual

PicoScope 4000 Series PC Oscilloscopes

Cryoelectronics. MS-FLL User s Manual. Mr. SQUID Flux-Locked Loop. STAR Cryoelectronics 25 Bisbee Court, Suite A Santa Fe, NM U. S. A.

Tube Rotator. User Guide. Version 1.2

CM-S23349SV. Vari-Focal IR Bullet Camera

Outdoor IR Audio Camera

CM-S38901SV TVL IR Long Range camera

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

Element 78 MPE-200. by Summit Audio. Guide To Operations. for software version 1.23

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

SAFETY TERMS AND SYMBOLS

XO-231 USER S MANUAL. Crossover ENGLISH

Colour Explosion Proof Video Camera USER MANUAL VID-C

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

PREAMPLIFIER INTRODUCTION INSTRUCTIONS FOR USE. Thank you for purchasing the Musical Fidelity A3 CR remote control preamplifier.

/ PAT01 USER MANUAL

Kramer Electronics, Ltd. USER MANUAL. Model: 482xl. Bi-directional Audio Transcoder

USER MANUAL. VM-10xl Video Audio Distribution Amplifier MODEL: P/N: Rev 4

T L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

TS2.8 Sub OWNER S MANUAL

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Recording to Tape (Analogue or Digital)...10

SK2002DA SIDEKICKER 1-IN, 2-OUT VGA-UXGA DISTRIBUTION AMPLIFIER CABLE USER S GUIDE DISTRIBUTION AMPLIFIERS

Kramer Electronics, Ltd. USER MANUAL. Model: Power Amplifier

CDM10: Channel USB Mixer. Item ref: UK User Manual

Kramer Electronics, Ltd. USER MANUAL. Models: TR-1YC, s-video Isolation Transformer TR-2YC, s-video Dual Isolation Transformers

Kramer Electronics, Ltd. USER MANUAL. Model: VM-10xl. Video Audio Distribution Amplifier

ER-100 Eurorack 8 Channel Stereo, Transformer Balanced Out Summing Mixer User Manual

Kramer Electronics, Ltd. USER MANUAL. Model: PT-102VN. 1:2 Video DA

Users Manual. Stroboscope. September 2014

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

12 Channel Media Splitter MS12 Mk2 User manual

Kramer Electronics, Ltd. USER MANUAL. Model: VP-100. VGA/XGA to RGBHV Converter

Premier. Pre-Amplifiers. User Manual

3B SCIENTIFIC PHYSICS

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

Owner s Manual. Model PH8 Phono Preamplifier

MICROMASTER Encoder Module

USER MANUAL MX102 & MX1202

Instructions. P MHz 1X/10X Passive Probe

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

Chameleon Labs Model 7720

Ios english manual:ios english manual.qxd 07/08/ :35 Page 1

HulaMixer Sample Mixer

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

.Power Distribution Center. PD-1. Instruction Manual


SoundField UPM-1 Stereo to 5.1 Converter

C200H-AD002/DA002 Analog I/O Units Operation Guide

PAM-1840 Preamplifier Operation Manual

Kramer Electronics, Ltd. USER MANUAL. Model: 900xl. Power Amplifier

Kramer Electronics, Ltd. USER MANUAL. Model: VS-33Vxl. 3x1 Video Switcher

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Installation Guide VL-MV10. Model No.

WVR500 Waveform/Vector Monitor

800 Displaying Series Flowmeter

USER MANUAL. Kramer Electronics, Ltd. Models:

MANUAL ENGLISH Core Club Ordercode: D2314

TVAC20000 User manual

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

PLL1920M LED LCD Monitor

Tube Roller Shakers. User Guide. Version 1.2

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Kramer Electronics, Ltd. USER MANUAL. Model: 810B. Black Burst / Audio Generator

Technical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications

Kramer Electronics, Ltd. USER MANUAL. Models: OC-1N, Video Isolator OC-2, Dual Channel Video Isolator OC-4, Quad Channel Video Isolator

AMEK SYSTEM 9098 DUAL MIC AMPLIFIER (DMA) by RUPERT NEVE the Designer

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

Gordian. Multifunctional Power Distributor / Conditioner. v1.3

VPS 100 YPSILON PHONO STAGE. OWNERS MANUAL V1 01/01/2010 All rights reserved

USER MANUAL. PT-102VN 1:2 Video DA MODEL: P/N: Rev 2

Kramer Electronics, Ltd.

Integre4. Audiophile integrated amplifier. v1.2

Waveform Monitor/Vectorscope, PM 5661 Waveform Monitor/Vectorscope, Sc-H, PM 5661/70

Kramer Electronics, Ltd.

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

CDV07. Analog video distribution amplifier(s)

Kramer Electronics, Ltd. USER MANUAL. Model: VS x1 Video Audio Switcher

PEGAS 160 T PULSE HF PEGAS 200 T PULSE HF

384A Adapter Installation Instructions

TRF STEP-DOWN TRANSFORMER USER MANUAL

Transcription:

Operation Manual for SCU1 Signal Conditioning Unit

Table of Contents 1. About this Manual 4 1.1. Symbols Glossary 4 2. Safe Use 4 3. Compatible Magnetometers 5 4. Introduction to the SCU1 5 4.1. Summary 5 4.2. Functional Description 5 4.2.1. Power 5 4.2.2. Signal Conditioning 5 5. SCU1 Inputs, Outputs and Controls 7 5.1. Back Panel Connections and Controls 7 5.2. Front Panel Displays and Controls 8 6. Installing the SCU1 10 6.1. Location of the Equipment 10 6.1.1. Environmental Precautions 10 6.1.2. Mounting 10 6.1.3. Orientation 10 6.1.4. Temperature 10 6.1.5. Proximity to Other Equipment 10 6.2. Connecting the Equipment 11 6.3. Initial Settings 11 6.3.1. Magnetometer Supply Voltage 11 6.3.2. Magnetometer Output Type Selection 11 7. Using the SCU1 12 7.1. Output Scaling 12 7.1.1. Converting Output Voltage to Magnetic Units 12 Page 2 of 19

7.2. Over-range Condition 12 7.3. Switching ON and OFF 13 7.4. Using the SCU1 Controls 13 7.4.1. Offset Controls 13 7.4.2. Gain Controls 13 7.4.3. Low Pass Filter (LPF) 14 7.4.4. High Pass Filter (HPF) 14 7.5. Using the SCU1 Outputs and Displays 15 7.5.1. Unconditioned and Conditioned Outputs 15 7.5.2. Display Panel Meters 15 8. Troubleshooting 16 9. Care and Maintenance 17 9.1. Fuses 17 9.2. Calibration 17 9.3. Cleaning 17 10. End of Life Disposal 18 Notes 18 Page 3 of 19

1. About this Manual This manual provides the information necessary to help customers operate the SCU1 Signal Conditioning Unit from Bartington Instruments. It should be read in conjunction with product brochure DS2519, which can be found on the SCU1 product page on the Bartington Instruments website at: www.bartington.com. 1.1. Symbols Glossary The following symbols used within this manual call your attention to specific types of information: WARNING: Indicates a situation in which serious bodily injury or death could result if the warning is ignored. Caution: Indicates a situation in which bodily injury or damage to your instrument, or both, could result if the caution is ignored. Identifies items that must be disposed of safely to prevent unnecessary damage to the environment. Note: Provides useful supporting information on how to make better use of your purchase. 2. Safe Use WARNING: These products are not qualified for use in explosive atmospheres or life support systems. Consult Bartington Instruments for advice. WARNING: The SCU1 is powered by mains electricity. The unit MUST be earthed. The centre pin of the IEC inlet on the rear panel is internally connected to all the metal panels of the unit. Use the 3-core connecting cable supplied with the unit to ensure the unit is correctly earthed. Use of an alternative cable may render the unit unsafe. WARNING: The IEC mains inlet socket must be fitted with two fuses of the type specified in the product brochure. WARNING: This unit is not sealed against the ingress of water and must only be operated under dry conditions. Page 4 of 19

3. Compatible Magnetometers The SCU1 is designed to be compatible with the sensors shown on the Product Compatibility page of the Bartington Instruments website at: www.bartington.com/product-compatibility.html. Caution: Use of incompatible sensors may cause damage to the SCU1 and/or the sensor. 4. Introduction to the SCU1 4.1. Summary The SCU1 Signal Conditioning Unit combines the functions of a power supply unit, an analogue signal conditioner and a display unit for use with compatible Bartington Instruments magnetometers. The unit connects to a single three-axis magnetometer and enables the user to monitor the X, Y and Z magnetic field components via the following outputs: unconditioned analogue outputs (signals), direct from the magnetometer conditioned analogue signals (the magnetometer signals modified by the SCU1 analogue conditioning) digital display meters. The SCU1 is suitable for use in many situations including: where analogue signals from the magnetometer require adjustment to match the input requirements of control electronics or of an analogue to digital (A-to-D) converter system as a three-axis magnetic field meter, giving a digital display of the X, Y and Z values from the magnetometer where both a digital display and analogue voltage signals are required. 4.2. Functional Description 4.2.1. Power The SCU1 includes an integral power supply for the attached magnetometer. 4.2.2. Signal Conditioning The SCU1 applies three stages of analogue processing, converting the unconditioned magnetometer outputs into the conditioned outputs. Page 5 of 19

1. Filtering: Signals can be filtered (using low and high pass filters) to remove unwanted frequencies. 2. Offset: In the second stage, a DC offset voltage can be added to or subtracted from the magnetometer output signal, producing a DC adjusted output. 3. Gain: Finally, the DC adjusted output signal can be amplified by a variable gain stage, to produce the conditioned output signal. Offset and gain are controlled independently for the X, Y and Z channels, but the filter settings are common to all three. The conditioned output signals and the original magnetometer (unconditioned) output signals are available as analogue voltages from the SCU1. In addition, the DC components of each conditioned signal are displayed digitally on display meters. Page 6 of 19

5. SCU1 Inputs, Outputs and Controls 5.1. Back Panel Connections and Controls 1 2 3 4 6 5 Figure 1. Back panel connections and controls. Key to Figure 1 1. Unconditioned Outputs. These three BNC connectors provide buffered versions of the X, Y and Z output signals from the magnetometer. Signals are only valid when the SCU1 is switched ON. They are not affected by any of the other SCU1 controls. 2. Magnetometer Socket. This multi-pin socket is for the connection of the magnetometer cable. 3. Magnetometer Output Type Selector Switch. The SCU1 can be used with magnetometers that have unbalanced (single-ended) outputs or balanced (differential) output signals. This switch sets the SCU1 to operate in unbalanced or balanced mode. Caution: This switch must be set to match your magnetometer output type (see Magnetometer Output Type Selection). 4. IEC Mains Socket (Electrical Supply Input). The unit requires an AC mains supply as specified in the product brochure via this IEC inlet socket. WARNING: The socket includes a removable fuse carrier. The correct fuse types must be fitted. Refer to the product brochure for fuse details. 5. ON/OFF Switch. The IEC inlet socket includes this ON(1)/OFF(0) switch, to control power to the unit. Page 7 of 19

6. Conditioned Outputs. These three BNC connectors carry the conditioned analogue output voltages. The conditioned outputs are the magnetometer X, Y and Z signals after they have been modified by the filter, gain and offset controls. 5.2. Front Panel Displays and Controls 7 8 9 10 14 13 12 11 Figure 2. Front panel displays and controls. Key to Figure 2 7. Low Pass Filter (LPF) Control. The SCU1 applies low pass filtering to the magnetometer output signals. This control sets the -3dB point frequency for the LPF. Note: The LPF cannot be completely disabled. 8. High Pass Filter (HPF) Control. The SCU1 can apply high pass filtering to the magnetometer output signals. This control sets the -3dB point frequency for the HPF. 9. Magnetometer Supply Voltage Control. This control sets the voltage that the SCU1 supplies to the magnetometer connector power pins. This enables the user to vary the voltage to compensate for cable voltage loss, ensuring the required voltage is present at the magnetometer. See Magnetometer Supply Voltage for guidance on matching voltage to cable length. 10. Display Panel Meters. The conditioned output voltages for the three channels are displayed numerically on these 3½ digit meters. The meters display in volts and should only be used for low frequency signals. See Display Panel Meters for full details on how to use the meters. Page 8 of 19

11. Offset Switches (one for each channel). These 3-position switches control the polarity of the offset DC voltages applied to the magnetometer output signals (see Table 1 below). There is an individual switch for each of the X, Y and Z channels. Switch Position Polarity Function Centre OFF No offset Up + Offset voltage is added Down - Offset voltage is subtracted Table 1. Offset switch functions. 12. Offset Coarse Controls (one for each channel). 13. Offset Fine Controls (one for each channel). These rotary controls set the offset DC voltages applied to each of the X, Y and Z channels. For guidance on use of the offset controls see Offset Controls. 14. Gain Controls (one for each channel). These controls set the gain (amplification) that is applied to each of the X, Y and Z channels. Note: The effect of the gain control is dependent on the offset voltage. See Gain Controls for guidance on use of the gain and offset facilities. Page 9 of 19

6. Installing the SCU1 6.1. Location of the Equipment 6.1.1. Environmental Precautions WARNING: This equipment is powered by mains electricity. It should not be used in wet or damp locations, where water may enter the unit and create a safety hazard. Refer to the product brochure for maximum environmental ratings for the SCU1. Caution: Exceeding the maximum environmental ratings may cause irreparable damage to the equipment. 6.1.2. Mounting The SCU1 can be used: free-standing, on a bench-top, or mounted in a 19 rack, using the integral side brackets. 6.1.3. Orientation The SCU1 can be orientated horizontally or vertically. 6.1.4. Temperature To minimise temperature induced drift effects, position the SCU1: in a constant ambient temperature out of direct sunlight. 6.1.5. Proximity to Other Equipment The SCU1 contains no high frequency electronics likely to cause emissions which could cause interference with other equipment. The unit is unlikely to be affected by interference from other equipment in the normal operating environment. Note: The sensors used with this unit, being designed to measure magnetic fields, are susceptible to electromagnetic interference. Avoid operation close to high frequency sources of radiation. Interference is indicated by instability in the reading when the sensor is maintained in a fixed position. Page 10 of 19

6.2. Connecting the Equipment Connect the equipment using the following sequence: 1. Connect the magnetometer to the SCU1 magnetometer socket. Ensure the connector pins are correctly aligned with those in the socket. The locking ring should be hand-tightened only. 2. If your system will use the SCU1 analogue outputs, connect the conditioned and/or unconditioned BNC outputs to your external equipment, as required. 3. Ensure the IEC socket mains switch (Figure 1, item 5) is OFF (position 0). Connect your mains supply cable to the IEC socket. The unit will operate with a mains supply in the range specified in the product brochure. Range selection is automatic within the unit. 6.3. Initial Settings 6.3.1. Magnetometer Supply Voltage Before switching the equipment ON, set the appropriate voltage for your magnetometer, using the front panel control (Figure 2, item 9). For all Mag648 and Mag-03RC magnetometers, use the 12V setting. For Mag-03MC, MS and IE magnetometers, the voltage setting should be used to compensate for any voltage loss in the magnetometer cable. Refer to individual sensor brochures to select the correct setting for your cable length (see the Mag-03 product brochure DS0013, available from the Bartington Instruments website, for recommended cable types). 6.3.2. Magnetometer Output Type Selection Before switching on the equipment, set the magnetometer output type selector switch (Figure 1, item 3) to the correct position for your magnetometer: see Table 2. See individual sensor data sheets for those not mentioned in this table. Magnetometer Mag-03MS Mag-03MC Mag-03IE Mag-03RC Mag648 Output Type Unbalanced Unbalanced Unbalanced Balanced Balanced Page 11 of 19

Table 2. Magnetometer output types. 7. Using the SCU1 7.1. Output Scaling 7.1.1. Converting Output Voltage to Magnetic Units The conditioned output voltage at the output connectors is displayed on the panel meters and can be converted into magnetic field strength units (e.g. Tesla). The conversion will depend on the range of your magnetometer, analogue output voltage, and scale factor of your magnetometer. Scale factor = range / analogue output of magnetometer. For example: a magnetometer with a range of 250μT and an analogue output of ±10V has a scale factor of 25 a magnetometer with a range of 60μT and an analogue output of ±3V has a scale factor of 20. To convert voltage to field strength: 1. Divide the output voltage by the gain control setting, then 2. Multiply by the scale factor for your magnetometer. For example, if the display for the X axis shows 6.5V when connected to a magnetometer with a range of 250μT and an analogue output of ±10V, with SCU1 gain = 50, this indicates an X axis field of: (6.5/50) x (250/10) = 3.25µT 7.2. Over-range Condition The SCU1 conditioned output and display meter readings are only accurate when in the range -10V to +10V. Readings beyond -10 to +10V are considered over-range as they will not be to the specification accuracy. Note: Use the offset and gain controls, as described in Using the SCU1 Controls, to ensure the conditioned outputs do not go over-range. Page 12 of 19

7.3. Switching ON and OFF Caution: Connect the magnetometer before switching on the SCU1, as connecting a live cable to the magnetometer may cause damage. Similarly, switch off the SCU1 before disconnecting the magnetometer. Caution: The SCU1 should be switched on and off using the IEC socket switch (Figure 1, item 4) ( 0 = OFF, 1 = ON). Note: For best results, after switching ON, leave the SCU1 for 10 minutes for the internal temperature to stabilise, before performing any measurements. 7.4. Using the SCU1 Controls 7.4.1. Offset Controls The offset controls apply a DC offset value to the magnetometer output voltage, to generate a DC adjusted signal voltage. This resulting voltage will be amplified by the gain controls, to form the final SCU1 conditioned output signal. The offset voltage range limits are -10 to +10V. The offset control includes a coarse adjust, to set an approximate level, and a fine adjust to achieve the exact offset level desired. A polarity switch selects whether the offset is added to or subtracted from the magnetometer output, or set to OFF (zero offset). Offset is generally used where an AC magnetic field being investigated is superimposed on a background static (DC) field. The DC signal can be eliminated from the SCU1 conditioned output by applying offset. The conditioned output will then contain only the AC signal, which can be investigated at high resolution by using gain (amplification). Example: to remove the background DC field from the X channel: 1. Set the X channel gain to 1, and the HPF to DC. 2. Set the X channel offset polarity switch to the centre position (no offset). 3. If the X channel meter shows a + reading, set the offset polarity to -; if meter shows -, set offset polarity to +. 4. Adjust the offset controls until the meter reading decreases to zero. 7.4.2. Gain Controls The gain controls apply amplification to the DC adjusted signals from the offset stage, to generate the SCU1 conditioned analogue outputs. Page 13 of 19

Gain is a simple multiplication of the signal, so a gain of 300 will, for example, convert a 1mV signal into a 300mV signal at the output. Gain can be set to 1, 50, 100, 300, 500 or 1000, independently for the three channels. Note: Excessive gain will result in the SCU1 output becoming over-range. When applying gain, start with gain = 1 and increment the control until you find the maximum setting that does not cause the over-range condition. Note: Both AC and DC components of the adjusted magnetometer signals are amplified by the gain. If a signal contains a large DC component, gain may cause the output to go overrange. To prevent this, the DC component can be removed using the offset controls. In general, gain is used to improve measurement resolution of small signals, usually when studying AC fields or very slow changes to a background DC field. In these situations, any DC signal present would normally be removed by using offset. This allows the level of gain to be set as high as possible, without the output becoming over-range. 7.4.3. Low Pass Filter (LPF) The LPF attenuates high frequencies above the -3dB setting, reducing their amplitude in the SCU1 conditioned outputs. The LPF is intended to be used for removal of unwanted frequencies present in the magnetic field being measured. The LPF -3dB frequencies settings are 1, 10, 100, 1000 and 10000Hz. The LPF cannot be completed disabled. If LPF is not required, use the 10000Hz setting to ensure the maximum signal bandwidth is available. 7.4.4. High Pass Filter (HPF) The HPF implements AC coupling of the magnetometer input signals, attenuating low frequency signals below the HPF -3dB setting. The HPF is intended for the removal of DC and very slowly changing signals. The HPF -3dB frequencies settings are 0.01Hz, 1Hz, and OFF. Use OFF when HPF (AC coupling) is not required. Page 14 of 19

Note: When using the 0.01Hz setting, allow sufficient time (up to 1 minute) for the filter to settle. Momentary selection of the 1Hz setting will shorten the settling time. Note: The offset control can be used at the same time as using high pass filtering, but it is not normally required. It is recommended that the offset control be switched to the OFF position when using the HPF. 7.5. Using the SCU1 Outputs and Displays 7.5.1. Unconditioned and Conditioned Outputs The SCU1 analogue outputs should be used when both the AC and DC content of the signals need to be measured (e.g. with an oscilloscope, meter or an A-to-D system) or when a voltage output is required for connection, for example, to a feedback or control system. Note: The unconditioned outputs should be used if access to the direct analogue output signals from the magnetometer is required. Note: The conditioned outputs should be used to access the magnetometer output signals after the application of filtering, offset and gain by the SCU1. Consult the product brochure for maximum load. To convert the analogue voltage level into units of magnetic field at the magnetometer, refer to Converting Output Voltage to Magnetic Units. 7.5.2. Display Panel Meters The panel meters give a continuous digital display of the conditioned output voltage. Page 15 of 19

The meter readings are in volts. To convert the analogue voltage level into units of magnetic field at the magnetometer, refer to Converting Output Voltage to Magnetic Units. Note: The meters are updated at 3 readings per second and hence will only indicate the DC component (strictly, frequencies below 1Hz) present in the conditioned output voltage. 8. Troubleshooting The SCU1 is unlikely to suffer any defects in normal use: no internal components are serviceable. The most likely causes of failure, and their solutions, are detailed in the following table. In the event of any apparent malfunction beyond those described in the table below, please email service@bartington.com, or telephone the Bartington Instruments service team on +44 (0)1993 706565. Fault Possible cause Solution Panel meters are off Power fault Check SCU1 is connected to a mains supply. Check the ON/OFF switch position. Check the fuse in the IEC socket (see Fuses). Conditioned output shows an unexpected DC level, or is stuck at a large + or - value AC signals are distorted or clipped Magnetometer is unusually hot High pass filter, offset or gain control settings could be affecting the signal Gain is too high Power supply voltage is too high Ensure that the HPF is set to 0 (OFF). Check that the relevant offset control is OFF. If offset must be used, check the polarity is correct. Ensure the signal is not over-range due to excessive gain. Ensure you account for any gain applied in your conversion of voltage to magnetic units. Switch to a lower gain setting. Lower the voltage supply to the magnetometer. Page 16 of 19

9. Care and Maintenance The SCU1 requires no routine maintenance. The only user serviceable parts are the fuses in the IEC mains inlet socket. 9.1. Fuses To change a blown fuse, ensure the mains supply is disconnected, then extract the fuse block from the IEC socket with a blunt tool (e.g. flat-bladed screwdriver). Extract and replace the blown fuse. Replace the fuse block. WARNING: Fuses fitted must be of the type specified in the product brochure. 9.2. Calibration Return the SCU1 to Bartington Instruments for calibration at the recommended intervals. Refer to the Calibration Certificate for further details. 9.3. Cleaning WARNING: Disconnect the electrical supply before performing any cleaning operation. Periodic cleaning is not normally required. If the system becomes soiled and cleaning is necessary: 1. Use a damp cloth to clean the outer surfaces. 2. Use an air duster to blow debris from the connectors. WARNING: Ensure water does not enter the system. The system must be completely dry before the electrical supply is reconnected. Caution: Never use chemicals, such as solvents, when cleaning the SCU1. Caution: Take particular care when cleaning around electrical connections. Bent or damaged pins may cause the magnetometer to malfunction. Page 17 of 19

10. End of Life Disposal This product (electrical and electronic equipment) should not be placed in municipal waste. Check local regulations for disposal of electronic products. Notes Page 18 of 19

T: +44 (0)1993 706565 F: +44 (0)1993 774813 E: sales@bartington.com Bartington Instruments Limited 5 Thorney Leys Business Park, Witney, Oxford, OX28 4GE, England. www.bartington.com The copyright of this document is the property of Bartington Instruments Ltd. Bartington is a registered trade mark of Bartington Instruments Limited in the following countries: United Kingdom, Australia, Brazil, Canada, China, European Union, India, Japan, Norway and the United States of America.