I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Similar documents
I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Type: DILM25 10(24V50HZ) Article No.:

Type: DILM12 10(24VDC) Article No.:

Minicontactorrelay,2NO/2NC,DCoperated

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

AS09..S 3-pole Contactors - Spring Terminals

Series CT7N Bimetallic Overload Relays

Datasheet - SRB-E-201ST

Datasheet - SRB301LC 24VAC/DC

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Bulletin 190 IEC Modular Starter System

Ordering details. Approval. Classification

High performance circuit breakers

02/11/2015

A V 50Hz / V 60Hz

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Circuit breakers BZM. Circuit breakers BZM

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Modular pulse operated latching relay 16 A

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

GV2ME. Main. Device short name. Device application

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

TeSys circuit-breakers

DMX and 4000 air circuit breakers from 800 to 4000 A

llen-bradley 194R-HM4-NFPA3

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

GV2P05. Main. Device short name. Device application

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LED control gear Compact fixed output

LED Driver Compact fixed output

Magnetic and Hydraulic-Magnetic Circuit Breaker

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

GV2ME. Main. Device short name. Device application

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

LED Driver Compact dimming

LED Driver Compact fixed output

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LED Driver Linear / area fixed output

Power Circuit of a UL508A Panel. Typical UL489 Application

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

GR circuit breaker - hydraulic magnetic, Datasheet

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Circuit-Breakers for Motor Protection Series 8523/8

Features XT SC 012 B B A

Features XT SC 012 B B A

GR circuit breaker - hydraulic magnetic, Datasheet

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Magnecraft Power Relays

3AH3 Vacuum Circuit-Breakers

15 Series - Dimmer

16 A and 25 A power contactors with or without handle

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS


Kuhnke Technical Data. Contact Details

KRF EMC Filters Installation, Operation and Maintenance Manual

Busbar Systems. Altech UL489. UL489 Listed Busbars. Universal UL489 Busbar fits most UL489 Miniature Circuit Breakers in the market!

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Generator protection relay

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Capacitors and banks 50 Hz 0 400/415 V network voltage

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Manual Motor Starter Specifcations

LED MODULES READYLINE DL

Process transmitter RMA422

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Interface Relays and Optocouplers Product group picture

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

Transcription:

DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type Fixed Release system Thermomagnetic release Construction size NZM2 Number of poles 3 pole Standard equipment Screw connection Switching capacity 400/415 V 50 Hz I cu ka 150 Rated current = rated uninterrupted current Rated current = rated uninterrupted current I n = I u A 100 Setting range Overload trip I r A 80-100 Short-circuit releases Non-delayed I i = I n x 6-10 Short-circuit releases I rm A 600-1000 Technical data General Standards IEC/EN 60947 Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Ambient temperature, storage C - 40 - + 70 Operation C -25 - +70 Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 Safe isolation to EN 61140 g 20 (half-sinusoidal shock 20 ms) Between auxiliary contacts and main contacts V AC 500 between the auxiliary contacts V AC 300 Weight kg 2.345 Mounting position Vertical and 90 in all directions 04/01/2019 Eaton 259099 ED2019 V54.0 EN 1 / 10

With XFI earth-fault release: - NZM1, N1, NZM2, N2: vertical and 90 in all directions with plug-in unit - NZM1, N1, NZM2, N2: vertical, 90 right/left with withdrawable unit: - NZM3, N3: vertical, 90 right/left - NZM4, N4: vertical with remote operator: - NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90 in all directions Direction of incoming supply as required Degree of protection Device In the operating controls area: IP20 (basic degree of protection) Enclosures With insulating surround: IP40 With door coupling rotary handle: IP66 Terminations Tunnel terminal: IP10 Phase isolator and strip terminal: IP00 Other technical data (sheet catalogue) Temperature dependency, Derating Circuit-breakers Rated current = rated uninterrupted current I n = I u A 100 Rated surge voltage invariability U imp Main contacts V 8000 Auxiliary contacts V 6000 Rated operational voltage U e V AC 690 Rated operational voltage U e V DC 750 The following settings are required in order to ensure correct tripping: The fast-response release will take longer to respond when used for DC applications. Because of this, the setting on the trip block inscription, which is specified for AC currents, must be set to a lower value for DC currents. DC correction factor for instantaneous release response value: o NZM1: 1.25 o NZM2: 1.35 o NZM3: 1.45 Example: NZM3 Ie = 500A. Desired DC tripping current: 10 * Ie = 5000A. Calculation: Desired DC value / correction factor = AC setting on trip block 5000A / 1.45 = 3448 A ~ 7 * Ie = Value that needs to be set on the trip block Permitted circuit configurations: Overvoltage category/pollution degree III/3 Rated insulation voltage U i V 1000 Use in unearthed supply systems V 690 Switching capacity Rated short-circuit making capacity I cm 240 V I cm ka 330 400/415 V I cm ka 330 440 V 50/60 Hz I cm ka 286 525 V 50/60 Hz I cm ka 105 690 V 50/60 H Ic ka 40 04/01/2019 Eaton 259099 ED2019 V54.0 EN 2 / 10

Rated short-circuit breaking capacity I cn I cn Icu to IEC/EN 60947 test cycle O-t-CO Icu ka 240 V 50/60 Hz I cu ka 150 400/415 V 50/60 Hz I cu ka 150 440 V 50/60 Hz I cu ka 130 525 V 50/60 Hz I cu ka 50 690 V 50/60 Hz I cu ka 20 500 V DC I cu ka 60 750 V DC I cu ka 60 Ics to IEC/EN 60947 test cycle O-t-CO-t-CO Ics ka 240 V 50/60 Hz I cs ka 150 400/415 V 50/60 Hz I cs ka 150 440 V 50/60 Hz I cs ka 130 525 V 50/60 Hz I cs ka 37.5 690 V 50/60 Hz I cs ka 5 500 V DC I cs ka 15 750 V DC I cs ka 15 Rated short-time withstand current t = 0.3 s I cw ka 1.9 t = 1 s I cw ka 1.9 Utilization category to IEC/EN 60947-2 A Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release) Operations 20000 Lifespan, electrical AC-1 AC--3 DC-1 DC - 3 400 V 50/60 Hz Operations 10000 415 V 50/60 Hz Operations 10000 690 V 50/60 Hz Operations 7500 400 V 50/60 Hz Operations 6500 415 V 50/60 Hz Operations 6500 690 V 50/60 Hz Operations 5000 500 V DC Operations 7500 750 V DC Operations 7500 500 V DC Operations 3000 750 V DC Operations 3000 Max. operating frequency Ops/h 120 Total break time at short-circuit ms < 10 Terminal capacity Standard equipment Screw connection Optional accessories Box terminal Tunnel terminal connection on rear Round copper conductor Box terminal Solid 2 mm 1 x (10-16) 2 x (6-16) Stranded 2 mm 1 x (25-185) 2 x (25-70) Tunnel terminal Solid mm 2 1 x 16 Stranded 1-hole 2 mm 1 x (25-185) Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker. 04/01/2019 Eaton 259099 ED2019 V54.0 EN 3 / 10

Bolt terminal and rear-side connection Direct on the switch Al circular conductor Solid 2 mm 1 x (10-16) 2 x (6-16) Stranded 2 mm 1 x (25-185) 2 x (25-70) Tunnel terminal Solid mm 2 1 x 16 Stranded Stranded 2 mm 1 x (25-185) Bolt terminal and rear-side connection Direct on the switch Solid 2 mm 1 x (10-16) 2 x (10-16) Stranded 2 mm 1 x (25-50) 2 x (25-50) Cu strip (number of segments x width x segment thickness) Box terminal Bolt terminal and rear-side connection min. mm 2 x 9 x 0.8 max. mm 10 x 16 x 0.8 (2x) 8 x 15.5 x 0,8 Flat copper strip, with holes min. mm 2 x 16 x 0.8 Flat copper strip, with holes max. mm 10 x 24 x 0.8 Copper busbar (width x thickness) mm Bolt terminal and rear-side connection Screw connection M8 Direct on the switch Control cables min. mm 16 x 5 max. mm 24 x 8 2 mm 1 x (0.75-2.5) 2 x (0.75-1.5) Design verification as per IEC/EN 61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 100 Equipment heat dissipation, current-dependent P vid W 25.65 Operating ambient temperature min. C -25 Operating ambient temperature max. C 70 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 04/01/2019 Eaton 259099 ED2019 V54.0 EN 4 / 10

10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 7.0 Low-voltage industrial components (EG000017) / Power circuit-breaker for trafo/generator/installation protection (EC000228) Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kv) / Circuit breaker for power transformer, generator and system protection (ecl@ss10.0.1-27-37-04-09 [AJZ716013]) Rated permanent current Iu A 100 Rated voltage V 690-690 Rated short-circuit breaking capacity lcu at 400 V, 50 Hz ka 150 Overload release current setting A 80-100 Adjustment range short-term delayed short-circuit release A 0-0 Adjustment range undelayed short-circuit release A 600-1000 Integrated earth fault protection No Type of electrical connection of main circuit Screw connection Device construction Built-in device fixed built-in technique Suitable for DIN rail (top hat rail) mounting No DIN rail (top hat rail) mounting optional Yes Number of auxiliary contacts as normally closed contact 0 Number of auxiliary contacts as normally open contact 0 Number of auxiliary contacts as change-over contact 0 With switched-off indicator No With under voltage release No Number of poles 3 Position of connection for main current circuit Front side Type of control element Rocker lever Complete device with protection unit Yes Motor drive integrated No Motor drive optional Yes Degree of protection (IP) IP20 04/01/2019 Eaton 259099 ED2019 V54.0 EN 5 / 10

Characteristics 04/01/2019 Eaton 259099 ED2019 V54.0 EN 6 / 10

Let-through current 04/01/2019 Eaton 259099 ED2019 V54.0 EN 7 / 10

Let-through energy 04/01/2019 Eaton 259099 ED2019 V54.0 EN 8 / 10

Dimensions 1 Blow out area, minimum clearance to adjacent parts 2 Minimum clearance to adjacent parts 04/01/2019 Eaton 259099 ED2019 V54.0 EN 9 / 10

Additional product information (links) IL01206006Z (AWA1230-1916) Circuit-Breaker, basic unit IL01206006Z (AWA1230-1916) Circuit-Breaker, basic unit Temperature dependency, Derating CurveSelect characteristics program additional technical information for NZM power switch ftp://ftp.moeller.net/documentation/awa_instructions/il01206006z2015_11.pdf http://ecat.moeller.net/flip-cat/?edition=hplen&startpage=17.172 http://www.eaton.eu/de/europe/electrical/customersupport/configurationtools/characteristicsprogram/index.htm ftp://ftp.moeller.net/documentation/pdf/nzm_technic_de_en.pdf 04/01/2019 Eaton Industries GmbH http://www.eaton.eu 03/2019 by Eaton Industries GmbH Eaton 259099 ED2019 V54.0 EN 10 / 10