Systematic study of innovative hygroscopic and non-hygroscopic crystals with SiPM array readout

Similar documents
Silicon PhotoMultiplier Kits

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment

Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results

An extreme high resolution Timing Counter for the MEG Upgrade

An extreme high resolution Timing Counter for the MEG experiment Upgrade

Production and Development status of MPPC

A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read-out

CAEN Tools for Discovery

Tests of Timing Properties of Silicon Photomultipliers

Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals

Status of the CUORE Electronics and the LHCb RICH Upgrade photodetector chain

Investigation of time-of-flight PET detectors with depth encoding

ARDESIA: an X-ray Spectroscopy detection system for synchrotron experiments based on arrays of Silicon Drift Detectors.

Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

Nuclear Instruments and Methods in Physics Research A

3-D position sensitive CdZnTe gamma-ray spectrometers

Single Photoelectron timing resolution of SiPM

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Liquid Xenon Scintillation Detector with UV-SiPM Readout for MEG Upgrade

Single-sided CZT strip detectors

Solid State Photon-Counters

PoS(PhotoDet 2012)018

A very brief review of recent SiPM developments

Updates on the Central TOF System for the CLAS12 detector

Performance and Radioactivity Measurements of the PMTs for the LUX and LZ Dark Matter Experiments

DSP EC 50 and DSP EC 502. Advanced, Digital Signal Processing Based Gamma-Ray Spectrometers

Institute of Electrical and Electronics Engineers (IEEE)

Software Tools for the Analysis of the Photocathode Response of Photomultiplier Vacuum Tubes

Perugia 16 June 2009 Flavio Dal Corso INFN-Padova 1

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 5, OCTOBER

ASTROGAM Calorimeter: detector and FEE. Martino Marisaldi INAF IASF Bologna 1 st ASTROGAM Workshop, Roma Dec. 2013

arxiv: v1 [physics.ins-det] 2 Dec 2008

Development of an Abort Gap Monitor for High-Energy Proton Rings *

DATA ACQUISITION FOR MONOLITHIC SCINTILLATION DETECTORS IN PET APPLICATIONS

The hybrid photon detectors for the LHCb-RICH counters

li, o p a f th ed lv o v ti, N sca reb g s In tio, F, Z stitu e tests o e O v o d a eters sin u i P r th e d est sezio tefa ectro lity stem l su

Ultrafast Inorganic Scintillator Based Front Imager for GHz Hard X-Ray Imaging

Application of HDMI Cables as an MRI Compatible Single Cable Solution for Readout and Power Supply of SiPM Based PET Detectors

A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe HADES CBM

MPPC (multi-pixel photon counter)

Data Acquisition System for Segmented Reactor Antineutrino Detector

78 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 53, NO. 1, FEBRUARY Factors Influencing Timing Resolution in a Commercial LSO PET Camera

Advanced DSP Algorithms Ensure Enhanced Spectroscopic Performance

Thick Pixelated CZT Detectors With Isolated Steering Grids

Coincidence Detection using the Broadcom AFBR-S4N44P163 4 x 4 SiPM Array and the Vertilon SIB916 Sensor Interface Board Application Note

Application of Hamamatsu MPPC to T2K near neutrino detectors

Transmissive XBPM developments at PSF/BESSY. Martin R. Fuchs

Screen investigations for low energetic electron beams at PITZ

THE TIMING COUNTER OF THE MEG EXPERIMENT: DESIGN AND COMMISSIONING (OR HOW TO BUILD YOUR OWN HIGH TIMING RESOLUTION DETECTOR )

HAPD and Electronics Updates

The Scintillating Fibre Tracker for the LHCb Upgrade. DESY Joint Instrumentation Seminar

Realization and Test of the Engineering Prototype of the CALICE Tile Hadron Calorimeter

The Silicon Pixel Detector (SPD) for the ALICE Experiment

arxiv: v1 [physics.ins-det] 1 Nov 2015

DSP EC 50/50A and DSP EC 502/502A

Large photocathode 20-inch PMT testing methods for the JUNO experiment

Test beam data analysis for the CMS CASTOR calorimeter at the LHC

Sensors for precision timing HEP

Goo. Transport properties and performance of CdZnTe strip detectors

Advances in multi-pixel Geiger mode APDs (Silicon Photomultipliers).

TitleLarge strip RPCs for the LEPS2 TOF. Author(s) Chu, M.-L.; Chang, W.-C.; Chen, J.- Equipment (2014), 766:

TORCH a large-area detector for high resolution time-of-flight

Development of Ultra-High-Density (UHD) Silicon Photomultipliers with improved Detection Efficiency

NMOS linear image sensor

Citation X-Ray Spectrometry (2011), 40(6): 4. Nakaye, Y. and Kawai, J. (2011), ED

Atlas Pixel Replacement/Upgrade. Measurements on 3D sensors

Imaging diagnostico in Sanità Stato attuale e prospettive

A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications

MPPC (Multi-Pixel Photon Counter) arrays

Lawrence Berkeley National Laboratory

16-element Si photodiode arrays

THE WaveDAQ SYSTEM FOR THE MEG II UPGRADE

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Characterization of the VEGA ASIC coupled to large area position-sensitive Silicon Drift Detectors

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park

High ResolutionCross Strip Anodes for Photon Counting detectors

Performance and aging of OPERA bakelite RPCs. A. Bertolin, R. Brugnera, F. Dal Corso, S. Dusini, A. Garfagnini, L. Stanco

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

PULSE & DELAY GENERATOR. Output Amplitude HIGH SPEED DIGITIZER. BW / max. Sample Rate STREAK CAMERA

SciFi A Large Scintillating Fibre Tracker for LHCb

Design of a Gaussian Filter for the J-PARC E-14 Collaboration

A new Scintillating Fibre Tracker for LHCb experiment

Photonic Devices for Vehicle Evolution

Front End Electronics

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

Monolithic Thin Pixel Upgrade Testing Update. Gary S. Varner, Marlon Barbero and Fang Fang UH Belle Meeting, April 16 th 2004

Beam test of the QMB6 calibration board and HBU0 prototype

Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode. R.Bellazzini - INFN Pisa. Vienna February

MPPC and MPPC module for precision measurement

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

Commissioning and Performance of the ATLAS Transition Radiation Tracker with High Energy Collisions at LHC

TG 3 Status Report. C. Cattadori on behalf of TG3

InAsSb photovoltaic detector

VTA0832H Series Linear Photodiode Array (PDA) for X-ray Scanning

16-element Si photodiode arrays

Status of the Timing Detector Plastic+SiPM Readout Option

Position Resolution of Optical Fibre-Based Beam Loss Monitors using long electron pulses

Contents. 1. System Description 3. Overview 3 Part Names 3 Operating Conditions 7 Start-up Procedure 7. 2.

Transcription:

Systematic study of innovative hygroscopic and non-hygroscopic crystals with SiPM array readout 1,2, R.Bertoni 2, T. Cervi 3,4,M. Clemenza 1,2, A. de Bari 3,4, R. Mazza 2, A. Menegolli 3,4, M.C. Prata 4, M. Rossella 4, 1 Dipartimento di Fisica G. Occhialini, Universitá di Milano Bicocca 2 Sezione INFN Milano Bicocca 3 Dipartimento di Fisica, Universitá di Pavia 4 Sezione INFN Pavia Different crystals with SiPM array readout were tested in laboratory. Hygroscopic crystals, such as LaBr 3 :Ce and CeBr 3, and innovative non-hygroscopic crystals, such as PrLuAg and CeCAAG were studied. 4 4 SiPM arrays from different manufacturers were used as photodetectors. Best results were obtained with LaBr 3 :Ce crystals read by Hamamatsu S13361 TSV arrays. For LaBr 3 :Ce crystals, due to their high photon yield, it was possible to implement a simple readout scheme based on CAEN V1730 FADC, without any amplification. Energy resolutions (FWHM) better than 4% were obtained at the Cs 137 peak, with a detector linearity better than 2%. The European Physical Society Conference on High Energy Physics 5-12 July Venice, Italy Speaker. E-mail: maurizio.bonesini@mib.infn.it c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0). https://pos.sissa.it/

Counts/KeV x hour Counts/Kev x hour 1. Introduction Compact X-rays detectors based on crystals with SiPM array readout may find application in many fields such as TOF PET imaging [1], fundamental physics such as the FAMU measurement at Riken-RAL of the Zemach proton radius [2] and homeland security. For our aims it is essential to detect low-energy X-rays in the range 100-700 KeV. PrLuAG [3] and CeCAAG [4] crystals with respect to more conventional LaBr 3 :Ce, CeBr 3 [5] and NaI(Tl) crystals, have the advantage to be non hygroscopic and thus do not need encapsulation. Their main properties are shown in table 1. Table 1: Main characteristics of the crystals under test. Typical energy resolutions (FWHM in %), from published data, are measured at the Cs 137 peak with a PMT readout. Scintillators PrLuAG Ce:GAGG Ce:LaBr 3 CeBr 3 NaI(Tl) Density (g/cm 3 ) 6.73 6.63 5.08 5.18 3.67 Light yield (γ/mev) 22,000 57,000 75,000 47000 38000 Decay time (ns) 20 88 (91 %) 30 25 250 258 (9 %) Peak emission (nm) 310 520 375 370 415 Energy resolution 4.3 5.3 2.6 4.0 7.0 Hygroscopicity no no yes yes yes As one isotope (Lu 176 ) of naturally occurring lutetium is unstable 1 an intrinsic activity for PrLuAg crystals may be expected. The same is true for Ce:LaBr 3 crystals, due to the presence of La 138, that emits conversion electrons and β particles with energy up to 1.7 MeV. The intrinsic activity for all crystals under test was measured with a HpGe detector. The measured intrinsic activity spectrum is shown in figure 1. While the intrinsic activity of PrLuAg crystals is not negligible ( 36 Bq/g), the intrinsic activity of CeCAAG crystals is minimal ( 1.5 10 3 Bq/g). The activity of Ce:LaBr 3 ( 0.2 Bq/g) is half-way between the two. Background PrLUAG LaBr3:Ce CeCAAG CeBr3 Background PrLuAG LaBr3:Ce CeCAAG CeBr3 Energy (KeV) Energy (KeV) Figure 1: Intrinsic activity of the crystals under test, as measured with a HpGe detector, with a standard spectroscopic chain, based on a Ortec 672 spectroscopy amplifier and a MCA analyzer. The 1/2 " crystals under test are read by 4 4 SiPM arrays made of 3 3 mm 2 SiPM from SenSL, Advansid or Hamamatsu. Operating voltages (V op ) are set according to manufacturer s specs. Their response (PDE) to light of different wavelength depends also on the type of window used, as shown in figure 2 for Hamamatsu S13361 SiPM arrays. Most of our results were obtained 1 τ 1/2 = 3.78 10 10 years, 2.59 % abundance 1

3) 4) ) 1) 2) Figure 2: Left panel: response of Hamamatsu S13361 SiPM arrays to incident photons of different wavelengths and with different windows [courtesy of Hamamatsu Italia]. Right panel: crystal mounting. 1) is the PCB; 2) the crystal under test; 3) the crystal holder and 4) the cover to ensure light-tightness. with Hamamatsu S13361 arrays, based on a TSV ( through silicon via ) technology. For PrLuAg (with emission in the near UV) and LaBr 3 crystals SiPM arrays with a Silicone window were used to increase response at NUV wavelengths. The output from each pixel of the 4 4 SiPM array is summed up on a custom PCB ( basette ). The crystal and the basette are mounted inside a light-tight housing printed with a 3D printer (see the right panel of figure 2 for details). The optical coupling between the crystal and the SiPM array was obtained with a Bicron BC630 optical grease 2. Five out of six faces of the crystal were covered with an optical reflector. As the PrLuAg emission is around 310 nm it was difficult to find a proper optical diffuser or reflector. The best solution was to use the water based Avian-B optical coating (mainly based on BaSO 4 ) that has a 97%(93%) reflectance in the range 400-850 (250-400) nm. An Al diffuser was used instead for CeCAAG crystals. 2. Experimental results Detectors response has been studied at room temperature, using a standard spectroscopic chain based on various types of amplifiers 3 and a CAEN N957 MCA. The acquired data, written in ASCII format, were then analyzed with the ROOT package. Temperature excursions in the test setup were monitored with a precision thermometer 4. The best results were obtained with the Ortec 672 Spectroscopy amplifier, with a 3 µs shaping time. In the other cases energy resolutions were a 10-30 % worse. Figure 3 shows a typical MCA spectrum obtained from a PrLuAg (LaBr 3 :Ce) crystal read by a S13361 Hamamatsu SiPM array, using a Cs 137 source. With a PrLuAg (CeCAAG) crystal the best resolution obtained is around 7% (6%). The result obtained for PrLuAg is worse as compared with what obtained with a PMT readout in reference [3], but is better compared with what obtained with a SiPM array readout in reference [6]. Probably this is due to the lower dark noise of the new TSV S13361 Hamamatsu SiPM arrays used. As a reference, with LaBr 3 :Ce crystals we obtain at the Cs 137 peak a resolution better than 4%. Typical results obtained for the crystals under test, with SiPM array readout, are resumed in table 2. 2 with a nearly flat transmission (95%) between 280 and 700 nm 3 Ortec 672, Ortec 579, Phillips Scientific PLS774 and CAEN A1423 amplifiers were used 4 Hanna Checktemp 1 with 0.1 0 C resolution and ±0.3 0 C accuracy 2

1400 hist Entries 938 Mean 528.9 1200 RMS 106.5 Constant 1427 ± 6.9 Mean 601.1 ± 0.1 Sigma 18.62 ± 0.06 1000 Counts 800 600 400 200 Counts 700 600 500 400 300 200 100 hist Entries 480 Mean 263.8 RMS 41.63 Constant 632.6 ± 10.1 Mean 308.9 ± 0.1 Sigma 3.952 ± 0.038 0 400 500 600 700 800 900 Channel 0 200 220 240 260 280 300 320 340 Channel Figure 3: Energy spectrum of the 662 kev gamma rays, as measured with the 14 14 13 mm 3 PrLuAg (left) and LaBr 3 (right) crystals coupled to the MPPC array (Hamamatsu S13361 with a Silicone window). MCA counts are reported on the abscissa. Plots are not corrected for linearity. Table 2: Obtained FWHM energy resolutions (in %) at the Cs 137 peak for some specimen of the crystals under test. H/A refers to the used Hamamatsu S13361/Advansid ASD-P-4-TD NUV SiPM arrays. resolution LaBr 3 (H) LaBr 3 (A) CeBr 3 (H) CeCAAG (H) PrLuAg (H) NaI(Tl) (H) Ortec 672 3.1 % 3.8 % 4.7 % 6.4 % 7.2 % 8.4 % Ortec 579 3.4 % 4.3 % 5.0 % - - 8.9 % As LaBr3:Ce crystals with a SiPM array readout give a sizeable signal in the 100-200 mv range, a simple FADC readout scheme may be implemented. The signal is either shaped by an Ortec 672 spectroscopic amplifier and then fed to a CAEN V1730 FADC( 12 bit, 500 Ms/s) or directly fanned into the FADC. Bias to the SiPM is common for all the 16 cells of an array and is given by an ISEG NHS 6001 NIM module. Figure 4: Left top panel: energy resolution (FWHM) dependence for LaBr 3 :Ce crystals from the operating voltage (V op ). Left bottom panel: dependence of the detector response from temperature, at fixed V op = 53.8 V. Right panel: linearity and energy resolution of a typical LaBr 3 crystal, at room temperature. The variation of energy resolution at the Cs 137 peak for LaBr 3 crystals with Hamamatsu readout, as a function of the operating voltage V op, is shown in the left panel of figure 4 together with 3

the dependence of the response from temperature, measured inside a Memmert IPV30 climatic chamber. The right panel of figure 4 shows instead the linearity and the resolution (FWHM) for a typical LaBr 3 crystal under test at V op = 53.8V using Na 22, Cs 137, Ba 133 and Co 57 exempt sources. For effective use in experimental conditions, one has to take into account the SiPM gain drift with temperature. In the present setup, a thermistor is mounted on the basette, to make an offline correction afterwards. In the near future, we plan to correct online the SiPM gain drift by using a NIPM-12 SiPM power module from Nuclear Instruments srl Lambrugo (IT) that integrates a temperature HV loop, to regulate the SiPM bias voltage as a programmable function of the SiPM temperature coefficient. 3. Conclusions Preliminary results for the used crystals with a SiPM array readout show that they are promising for what regards energy resolution, even if performances for PrLuAg are not yet optimal. Their possible use with low-energy X rays needs further optimization. Good results are obtained with more conventional LaBr 3 :Ce crystals using the new low-noise NUV SiPM arrays from Hamamatsu and Advansid, making this our best choice for the time being. A simple electronics front-end based on CAEN V1730 FADC, without an amplification stage, gives resolution (FWHM) at the Cs 137 peak better than 4%, comparing well with the best available results. Acknowledgements We acknowledge the help of S.Banfi and F. Chignoli (INFN Milano Bicocca) for mechanics and electronics setup mounting. We would like to thank also Dr. E. Vallazza (INFN Trieste) for his friendly help in implementing the data acquisition for the test setup. References [1] K. Kamada et al., Basic experiments on radiation imaging by using Pr : Lu 3 Al 5 O 12 (LuAG) small crystalline pixels with various reflectors, IEEE Trans. Nucl. Science N24-208 (2007) 1417. [2] A. Vacchi et al., Measuring the size of the proton, SPIE Newsroom (2012); doi: 10.1117/2.1201208.004274; A. Adamczak et al., Steps towards the hyperfine splitting measurement of the muonic hydrogen ground state: pulsed muon beam and detector system characterization, JINST 11/5 P05007 (2016); doi: 10.1088/1748-0221/11/05/P05007. [3] W. Drozdowski et al., Scintillation Properties of Praseodymium Activated Lu 3 Al 5 O 12 Single Crystals, IEEE Trans. Nucl. Science 55 (2008) 2429 [4] J.Y. Yeom et al., First Performance Results of Ce:GAGG Scintillation Crystals With Silicon Photomultipliers, IEEE Trans Nucl Science 60, no.2 (2013) 988. [5] F.G.A Quarati et al., Scintillation and detection characteristics of high-sensitivity CeBr 3 gamma-ray spectrometers, Nucl. Instr. Meth. A729 (2012) 596; doi: 10.1016/j.nima.2013.08.005. [6] T. Kato et al., Development of a large-area monolithic 4x4 MPPC array for a future PET scanner employing pixelized Ce:LYSO and Pr:LuAg crystals, Nucl. Instr. Meth. A638 (2011) 83; doi: 10.1016/j.nima.2011.02.049. 4