XT-17M-B relay - Delay-off, 1 C/O, 16 A

Similar documents
M-relays, 2, 3 or 4 pole, 7-12 A Datasheet

GR circuit breaker - hydraulic magnetic, Datasheet

GR circuit breaker - hydraulic magnetic, Datasheet

D-B relay - High DC breaking capacity, Datasheet

02/11/2015

Magnecraft Power Relays

Datasheet - SRB301LC 24VAC/DC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Ordering details. Approval. Classification

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil


Wall-/Pipe-Mount Level Indicator

Datasheet - SRB-E-201ST

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Process Transmitter RMA 422

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

02/11/2015

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

POWER. DA10-M Series. 10 Watts. Data Sheet. Total Power: 10 Watts Input Voltage: Vac # of Outputs: Single, 5 Volts SPECIAL FEATURES

LED Driver Compact fixed output

IP Roombox. Hotel Room Management

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

2-output DALI controller

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

Generator protection relay

Kuhnke Technical Data. Contact Details

Emergency lighting units EM powerled

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

High performance circuit breakers

LED Driver Compact fixed output

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Modular pulse operated latching relay 16 A

Series CT7N Bimetallic Overload Relays

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Single Point Flow Monitor SW118 SW119

Electrical Specifications

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Pluggable interface relays CR-M Miniature relays

Standard RS232 RS ma

LED Driver Linear / area fixed output

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Solid-State Digital Timer

AS09..S 3-pole Contactors - Spring Terminals

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Contactors and Contactor Assemblies

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Emergency lighting units EM powerled

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

Model IQ4-PC User Manual Revision Date:

HS-509 VIBRATION TRIP MODULE

Process transmitter RMA422

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Time-Lag Relays. User s Handbook (General Model)

LONWORKS Fibre Optic Converter

SH2RE16A4. Output relay module. Benefits. Description

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Interface Relays and Optocouplers Product group picture

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

LED Driver Compact dimming

Type Contact form Model

VAT 20 Adjustable Frequency Drive

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Warner Photoscanner MCS-500 Series LED Photoelectric Control

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Programmable time switches Multiple function - daily/weekly

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Selection guide siemens.com/sirius-modular-system

ABB EQmatic Energy Analyzer, M-Bus QA/S , 2CDG110226R0011, QA/S , 2CDG110227R0011

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

K-BUS Dimmer Module User manual-ver. 1

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

LED control gear Compact fixed output

Photoelectrics Through-beam Type PA18C.T..., DC

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

AF-300 E11 Adjustable Frequency Drive

Type: DILM12 10(24VDC) Article No.:

Lt DELTA USA, Inc

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Bulletin 190 IEC Modular Starter System

Transcription:

- Delay-off, 1 C/O, 16 A Datasheet Features Delay-off Single function Time ranges: XT-17M-B1 0.1...1 s XT-17M-B2 1...10 s XT-17M-B3 6...60 s XT-17M-B4 1...10 min XT-17M-B5 6...60 min XT-17M-B6 1...10 h 1 C/O contact 16 A / AC1 35 mm rail mounting LED indicator red and green Universal supply voltage 12..240 VAC Modular housing, 1 module Benefits Description The is a single function and single-time relay with possibility of fine timing by a potentiometer (within the frames of a particular range). To be controlled be supply voltage or control input. 6 times ranges available: 0.1...1 s 1...10 s 6...60 s 1...10 min 6...60 min 1...10 h Universal supply voltage 12...240 VAC/DC 50/60 hz and 1 change-over contact 16 A, AC1. Visual output indication by a red LED, 1 module wide, 35 mm rail mounting. Rated current 16 A / AC1 Long term availability 17.6 mm wide No maintenance Industry compliancy All our relays and accessories are designed according to regulations: EN 60255-6 EN 61010-1 CE Application Single function delay-off time relay. Suitable for applications where function and time requirements are known. For example to be used for pump delay time, after switching off heating or fan. 1

Technical specifications Connection diagram Time range Time range Time setting Time deviation Repeat accuracy Temperature coefficient 0.1 s...10 h in 6 alternates Potentiometer 5 % mechanical setting 0.2 % set value stability 0.01 % / o C, at 20 o C Control Load between A2 - on/off Control terminals Max. capacity of cable control Impulse length Reset time Yes A1 - on/off 9 nf (AC 230 V), max 20 pcs (1 pc - 1 ma) 12 nf without connected glow-lamps Min. 25 ms / Max. unlimited Max. 150 ms Output Number of contacts Rated current Breaking capacity Inrush current Switching voltage Min. breaking capacity DC Output indication Mechanical life Electrical life (AC1) 1x change-over contact /SPDT (AgNi/Silver alloy) 16 A / AC1 4000 VA / AC1, 384 W / DC 30 A / < 3 s 250 V AC1 / 24 V DC1 500 mw Red LED 30 x 10 6 operations 7 x 10 4 operations Supply and measuring Supply terminals Supply voltage Burden Power consumption Supply voltage tolerance Supply indication A1 - A2 12...240 VAC/DC (50/60 Hz) AC 0.7...3.0 VA/DC 0.5...1.7 W AC 0.025...0.2 VA / DC 0.5...1.7 W 0.85...1.1 Un Green LED 2

Technical specifications Connection Environmental conditions Operating temperature -20 C... +55 C Storage temperature -30 C... +70 C Electrical strength 4 kv (supply - output) Operating position Any Mounting 35 mm rail EN 60715 Protection degree IP40 front panel / IP20 terminals Overvoltage category III Pollution degree 2 Max. cable size Solid wire max.1 x 2.5 mm 2 or 2 x 1.5 mm 2 / with sleeve max. 1 x 2.5 mm 2 Mechanical data Dimensions (d x w x h) 90 x 17.6 x 64 mm Weight 62 g Standard EN 61812-1, EN 61010-1 3

Technical specifications Description Supply teminals Control input Output indication Supply indication Time setting Output contacts Functions U S t t t Time setting 1 s 10 s 1 min 10 min 1 h 10 h Min. 0.1 s 1s 6s 1 min 6 min 1 h Max. 1 s 10 s 60 s 10 min 60 min 10 h 4

Odering codes Art. no. Type Time range Function Contacts Voltage range 326001001 XT-17M-A1 0.1-1 s Delay-on 1 C/O 12-240 VAC/DC, 50/60 Hz 326001009 XT-17M-A2 1-10 s Delay-on 1 C/O 12-240 VAC/DC, 50/60 Hz 326001010 XT-17M-A3 6-60 s Delay-on 1 C/O 12-240 VAC/DC, 50/60 Hz 326001011 XT-17M-A4 1-10 min Delay-on 1 C/O 12-240 VAC/DC, 50/60 Hz 326001012 XT-17M-A5 6-60 min Delay-on 1 C/O 12-240 VAC/DC, 50/60 Hz 326001013 XT-17M-A6 1-10 h Delay-on 1 C/O 12-240 VAC/DC, 50/60 Hz 326001002 XT-17M-B1 0.1-1 s Delay-off 1 C/O 12-240 VAC/DC, 50/60 Hz 326001014 XT-17M-B2 1-10 s Delay-off 1 C/O 12-240 VAC/DC, 50/60 Hz 326001015 XT-17M-B3 6-60 s Delay-off 1 C/O 12-240 VAC/DC, 50/60 Hz 326001016 XT-17M-B4 1-10 min Delay-off 1 C/O 12-240 VAC/DC, 50/60 Hz 326001017 XT-17M-B5 6-60 min Delay-off 1 C/O 12-240 VAC/DC, 50/60 Hz 326001018 XT-17M-B6 1-10 h Delay-off 1 C/O 12-240 VAC/DC, 50/60 Hz 326001003 XT-17M-C1 0.1 s - 10 d Multifunction 1 C/O 12-240 VAC/DC, 50/60 Hz 326001004 XT-17M-C3 0.1 s - 10 d Multifunction 3 C/O 12-240 VAC/DC, 50/60 Hz 326001025 XT-17M-C1/6 0.1 s - 10 h Multifunction 1 C/O 24-240 VAC, 50/60 Hz or 24 VDC 326001019 XT-17M-D 0.1 s - 10 min Delay-on / Delay-off* 2 C/O 12-240 VAC/DC, 50/60 Hz 326001020 XT-17M-L - Latching 2 C/O 12-240 VAC/DC, 50/60 Hz 326001005 XT-17M-P 0.1 s - 100 d Recycler 1 C/O 12-240 VAC/DC, 50/60 Hz 326001006 XT-17M-S 0.1 s - 100 d Star-delta 2 C/O 12-240 VAC/DC, 50/60 Hz 326001021 XT-17M-2XA 0.1 s - 10 d Delay-on 2x 1 C/O 12-240 VAC/DC, 50/60 Hz 326001026 XT-35M-DC2 Weekly Digital time 2 C/O 12-240 VAC/DC, 50/60 Hz 326001028 XT-35M-DCL1 Daily - weekly Digital twilight switch 1 C/O 230 VAC, 50/60 Hz * without auxiliary supply 5

DS- V1.2 Dec 2013 Mors Smitt France SAS Tour Rosny 2, Avenue du Général de Gaulle, F - 93118 Rosny-sous-Bois Cedex, FRANCE T +33 (0)1 4812 1440, F +33 (0)1 4855 9001 E sales@msrelais.com Mors Smitt Asia Ltd. # 807, Billion Trade Centre, 31 Hung To Road Kwun Tong, Kowloon, HONG KONG SAR T +852 2343 5555, F +852 2343 6555 E info@morssmitt.hk Mors Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht, NETHERLANDS T +31 (0)30 288 1311, F +31 (0)30 289 8816 E sales.msbv@wabtec.com Mors Smitt Technologies Inc. 1010 Johnson Drive, Buffalo Grove, IL 60089-6918, USA T +1 847 777 6497, F +1 847 520 2222 E salesmst@wabtec.com Mors Smitt UK Ltd. Doulton Road, Cradley Heath West Midlands, B64 5QB, UK T +44 (0)1384 567 755, F +44 (0)1384 567 710 E sales.msuk@wabtec.com (c) Copyright 2013 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Mors Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Mors Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. Mors Smitt does not warrant that any of the information contained herein is complete, accurate, free from potential errors, or fit for any particular purpose. Mors Smitt does not accept any responsibility arising from any party s use of the information in this document.