Micro duct Cable with HDPE Sheath for Installation by Blowing

Similar documents
Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

TECHNICAL SPECIFICATION

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Number of Fiber 12 Core 24 Core 48 Core. Part Number

Number of Fiber 6 Core 12 Core. Part Number

1. General. 1. Scope. 2. Quality Assurance

TENDER SUMMARY. Tender Title:

Number of Fiber 6 Core 12 Core 24 Core 48 Core

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

Revision No. 4 Page No. Page 1 of 7

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

SPECIFICATION. Optical Fiber Cable

Detailed Specifications & Technical Data

LD Series High Performance Loose Tube Fiberoptic Cables

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

HERA RETICULATION FIBRE CABLE PRODUCT REQUIREMENTS

FREEDM Loose Tube Interlocking Armored Cables

OPTICAL FIBRE CABLE NETWORK 2004/1

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

ETSI ES V1.1.1 ( )

Ø 1000 * 588 mm 50 kg

Mining and Petrochemical Fiber Optic Cables

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

Product Catalogue. Fibre Optic Cable

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Empowering businesses through innovative network solutions.

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

SOLO ADSS Short-Span Cables, Fibers

Cable installation guidelines

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

Material Description Quantity UOM

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

OPTICAL CABLE FIBER-LAN INDOOR

1 1/2 13.5, 625 JCASS)

DOME OPTIC SPLICE CLOSURE

Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

TECHNICAL SPECIFICATION

Table of Contents. Open Matrix System (OMS) 1-2

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

SPECIFICATION. Spec No : VSS-1402-CS603B

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

We design, build, and manage web-scale networks for the needs of tomorrow. System Integration SERVICES

A IR-BL O W N SOLUTION C O D. M I C R O C O D. M I C R O D U C T

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE

Public Works Division Lighting District Fiber Optic Specifications April 2009

for FOSTEC INC. 1/ 15

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

Cables for robot applications

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

The advantages of using reduced coating diameter optical fibers (200µm) in ADSS cables for deployment in FTTx networks

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

SECTION 4 TABLE OF CONTENTS

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

PRO SERIES FIBRE-150M

Newsletter

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

Module 11 : Link Design

Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI CONTROLS AND INSTRUMENTATION/FB

Table of Contents. Teldor Cables and Systems Ltd.

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

Installation of Optical Fiber

Gear up for the future.

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

PM Couplers (Polarization Maintaining Couplers)

- Outdoor & Indoor Telephone Cables - Fiber Optic Cables - Electronic Control Cables - Control Cables - Data/LAN Cables - Coaxial Cables

Industry solutions: Broadcast

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

Underground Installation of Optical Fiber Cable by Pulling

Siam Pacific Electric Wire & Cable Co., Ltd.

The World Of Professional Fiber Optics. safe flexible reliable

White Paper. Next Generation of Fiber Optic Loose Tube Cable. ABSTRACT INTRODUCTION. Stephen Martin, Product Line Manager, RCDD

INDUSTRY SOLUTIONS: MINING

Transcription:

Optical Fiber Cable Technology Specification INTERNAL Optical Fiber Cable Specification Micro duct Cable with HDPE Sheath for Installation by Blowing GCYFY-12/24/36/48/72/96/144/288/432/576B1.3 V7.0 2018-3-20,CCopyright. Specifications subject to change without notice

1. General This specification covers the design and performance of the single mode optical cables to be used in air blown micro duct application. 1.1 Cable Description 12/24/36/48/72/96/144/192/216/288 /432/576G.652D SM-fibers. s SZ-stranded. Suitable for air blown cable in micro-duct installation. 1.2 Quality XCOM ensures a continuing level of quality in our cable products through several programs including ISO 9001. 1.3 Reliability XCOM ensures product reliability through rigorous qualification testing of each product family. Both initial and periodic qualification testing are performed to assure the cable s performance and durability in the field environment. 1.4 Reference ITU-T G.652D IEC 60794-1-1 IEC 60794-1-2 IEC 60794-3 IEC 60794-5 1.5 Working Condition Transportation and storage temperature:-30 ~+70 Installation temperature: -10 ~+50 Operation temperature: -30 ~+70 1.6 Minimum Allowable Bending Radius Static: 10D Dynamic: 20D D is the out diameter of the cable 1.7 Life Time Characteristics of a single-mode optical fiber Optical fiber cables- part1-1-generic specification-general Optical fiber cables- part1-2-generic specification-basic optical cable test procedure Optical fiber cables- part3-sectional specification- Outdoor cables Optical fiber cables- part5-sectional specification- Microduct cabling for installation by blowing Optical fiber cables supplied in compliance with the specifications can be capable of withstanding the typical service condition for a period of twenty-five (25) years without detriment to the transmission or operation and maintenance characteristics of the cable. 2. Optical Fiber In Cable(ITU-G652D) Optical properties of the SM fiber are achieved through a germanium doped silica based core with a pure

silica cladding which meets ITU-T G652D, UV curable acrylate protective coating is applied over the glass cladding to provide the necessary maximum fiber lifetime. Geometrical, optical, and mechanical characteristics of fiber in cable as the following table: Category Description Specification Before cable After cable Cladding diameter 125.0 1 m Cladding non-circularity 1.0 % Geometrical Core concentricity error 0.6 m Characteristics 245 10 m(before Colored) Coating diameter 250 15 m (Colored) Coating/cladding concentricity error 12 m Mode field diameter at 1310 nm 9.2 0.4 m Point discontinuity 0.05dB Attenuation at 1310 nm 0.34 db/km 0.36 db/km Attenuation at 1383 nm 0.34 db/km 0.35 db/km Attenuation at 1550 nm 0.21 db/km 0.22dB/km Attenuation at 1625 nm 0.23 db/km 0.24dB/km Dispersion in 1288 1339 nm 3.5 ps/(nm km) Optical Characteristics Mechanical Specification Dispersion in 1271 1360 nm Dispersion at 1550 nm Zero dispersion wavelength Zero dispersion slope Cable cut-off wavelength Polarization mode dispersion individual fiber Polarization mode dispersion design link value (M=20, Q=0.01%) Macro-bend loss (100 turns, 30mm radius, 1550/1625nm) Proof stress level Coating strip force(peak value) Fiber curl (Radius) 5.3 ps/(nm km) 18 ps/(nm km) 1300 1324 nm 0.092 ps/(nm 2 km) 1260 nm 0.2 ps/ km 0.1 ps/ km 0.1 db 100kpsi (0.69 GPa) 1.3~8.9N 4 m 3. Optic Cable 3.1 General Design Optical fibers are housed in loose tubes that are made of high-modulus plastic and filled with waterproof compounds. FRP is applied as central strength member. s are SZ-stranded around the strength member. s are used in and over the cable core to prevent it from water ingress. Polyethylene sheath is applied over the cable core as the outer sheath. 3.2 Construction 3.2.1 Cross Section of Cable

GCYFY-12/72B1.3 GCYFY-96B1.3 Centralstrength member GCYFY-144B1.3 GCYFY-192B1.3 GCYFY-216B1.3 GCYFY-288B1.3 GCYFY-432B1.3-24F/T GCYFY-576B1.3-24F/T

Item Loose tube 3.2.2 Dimensions and Descriptions of Cable Constructions contents Value 12 24 36 24 48 72 96 144 192 216 288 144 192 288 432 576 Number 2 4 6 2 4 6 8 12 16 18 24 6 8 12 18 24 Outer diameter 1.2 1.45 2.1 ±0.1mm Filler Number 4 2 0 4 2 0 0 0 2 0 0 0 counts per G.652D 6 12 24 Material Central Diameter strength (mm) member Diameter of PE lay Material Outer Color sheath Thickness (mm) Cable diameter(± 0.2mm) Max. tensile strength (N) For micro duct inside (mm) Blown distance (m) Cable weight(kg/km) Approx. FRP 1.2 1.6 2.4 2.4 1.6 2.8 2.25 2.8 2.8 2.25 2.8 / / /- 4.1 / / / 3.5 6.1 / 4.1 HDPE Black Approx.0.5 4.5 5.4 6.1 7.9 9.3 7.3 8.8 11.4 11.4 13.4 200 600 800 600 1000 800 1000 1200 800 1200 6~8 8~12 8~12 10~14 12~14 1200m test field 2*50m 10~ 14 12~14 14~16 16~20 16 26 36/ 29 52 52 80 42 76 110 105 140 3.2.3 Mechanical Performance of Cable Tensile performance(n) Crush(N/100mm) Short term Long term Short term Long term 1.0G 0.3G 500 150 G is the weight of cable per kilometer, the unit is Newton (N). 3.2.4 Color Code of the Fiber Each fiber can be identifiable throughout the length of the cable in accordance with the following color sequence. Fiber color in each tube starts from No. 1 Blue. Fiber color code 6 fibers per tube 12 fibers per tube 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 Red Black Yellow Purple Pink Aqua

Fiber color code 24 fibers per tube 1 2 3 4 5 6 7 8 9 10 11 12 Red Black Yellow Purple Pink Aqua 13 14 15 16 17 18 Blue with Red with Orange with black ring Green with Brown with black ring Slate with White with 19 20 21 22 23 24 Purple Yellow Nature with Pink with with black black ring ring Notes: No.13-24 fibers with except the black fiber which is nature color in stead Aqua with 3.2.5 Color Code of the Loose Tube and Filler The loose tubes will be identifiable in accordance with the following color sequence. Tube color code 1 2 3 4 5 6 7 8 9 10 11 12 Red Black Yellow Purple Pink Aqua Tube color code 24 tube Inner1 Inner 2 Inner 3 Inner 4 Inner 5 Inner 6 Inner 7 Inner 8 Inner 9 Inner 10 Inner 11 Inner 12 Red Black Yellow Purple Pink Aqua Outer 13 Outer 14 Outer 15 Outer 16 Outer 17 Outer 18 Green Brown Slate with White Blue with Orange with with black with black black with black black Stripe black Stripe Stripe Stripe Stripe Stripe Outer 19 Outer 20 Outer 21 Outer 22 Outer 23 Outer 24 Red with black Stripe The color of the fillers will be natural. Black with white Stripe Yellow with black Stripe Purple with black Stripe Pink with black Stripe Aqua with black Stripe

3.3 Mechanical, Electrical and Environmental Test Characteristics The finished cables can be subjected to the following mechanical, electrical and environmental conditions. Item Test Method Requirements Tensile performance Crush Bend Repeated bending Torsion Temperature cycling Water Penetration Compound flow IEC 60794-1-2-E1 Load: according to short term tensile described in 3.2.3 Cable length under tension: Not less than 50m. Duration of load sustain: 1min. Velocity of transfer device: 10mm/min IEC 60794-1-2-E3 Load: 500N Duration of load: 1min IEC 60794-1-2-E11A Mandrel radius: 10 times cable diameter Turns:10 Cycles:5 IEC 60794-1-2-E6 Bending radius: 20 times cable diameter Cycles: 25 Load: 25N Duration of cycle: Approximately 2s. IEC 60794-1-2-E7 Cycles:5 Length under test: 1m Turns: 180 Load: 40N IEC 60794-1-2-F1 Sample length: at least 1000m Temperature range: -30 ~+70 Cycles: 2 Temperature cycling test dwell time: 12 hours IEC 60794-1-2-F5B Time : 24 hours Sample length : 3m Water height : 1m IEC 60794-1-2-E14 Sample count:5 Sample length:300 5 mm, Remove length: 130 2,5 mm, Time:24h The maximum increase in attenuation less than 0.1dB. No change in attenuation after test at 1550nm. Under visual examination without the cable elements after test. No change in attenuation after test at 1550nm. Under visual examination without the cable elements. The imprint of the striking surface on the sheath is not considered mechanical damage. No change in attenuation at 1550nm after test. Under visual examination without the cable elements. No change in attenuation at 1550nm after test. Under visual examination without the cable elements. The variation on attenuation for each fiber less than 0.05dB at 1550nm Under visual examination without the cable elements. No permanent change in attenuation after test There is no change in attenuation coefficient at 1550nm after the test. No water leakage No filling compound dripped.

Other According to IEC 60794,YD/T 1460.4-2006 parameters Remark: No attenuation changes is considered as the attenuation changes 0.05 db. 4. Cable Sheath Marking Unless otherwise specified, the cable sheath marking shall be as follows: Color: white Contents: XCOM, the year of manufacture, the type of cable, length marking Interval: 1m 5. Packaging and Shipping 5.1 Reel Length Standard reel length: 2/4/6 km/reel 5.2 Cable Drum The cables are packed in wooden drums The minimum barrel diameter of the drum shall be more than 30 times of the nominal diameter for armored cable, and 25 times of the nominal diameter for unarmored cable. 5.3 Labeling The direction of rotation of the color scheme is shown by marking the clockwise and anti-clockwise ends with red and green adhesive tape respectively. The markings are on both sides of the flanges as follows: Cable Type/Size Cable Length Gross Weight. XCOM. Shipping mark. 5.4 Cable Packing Both cable ends are provided with protections against water penetration and firmly secured to the drum, so the cable cannot move and the turns cannot slide when it is moved, handled or laid. the inner end has at least 3 meters of accessible length to perform reception tests in the cables.