Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Similar documents
Orbit TM DIGITAL SHAKERS

9070 Smart Vibration Meter Instruction Manual

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

SNG-2150C User s Guide

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

DH551C/DH550C/DL550C Double Sided Display User Manual

HDCVI Camera User s Manual

SIMET AVIKO D INSTRUCTION MANUAL SORTING Solutions, Ltd.

OM2000N INSTALLATION MANUAL

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Renishaw Ballbar Test - Plot Interpretation - Mills

Manual placement system MPL3100. for BGA, CSP and Fine-Pitch components

Color TFT LCD Monitor The Art of Surveillance

Tube Rotator. User Guide. Version 1.2

1. Please do not place the display screen towards the ground. 2. Please avoid heavy impact or drop onto the ground.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

User Manual 15" LCD Open frame SAW Touch Monitor KOT-0150US-SA4W. Table of Contents

QuickSpecs. Models RB146AA#ABA Standard Configuration RB146AT#ABA Promotional Part Number (SmartBuy) HP L5006tm 15-inch LCD Touchscreen Monitor

Capstone Experiment Setups & Procedures PHYS 1111L/2211L

PLL1920M LED LCD Monitor

MachineryMate 800 operating guide Handheld vibration meter

User Manual. Adjustable Speed Vortex. Fixed Speed Vortex

LED Thunder S-150 Code 1097

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Elcometer Circular Ball Type. Drying Time Recorder. Operating Instructions

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Business Display Solutions - Institutional Television Mirror TV. Installation Guide for 32PM8822 ( BDL3221M) 42PM8822 (BDL4221M)

SRV02-Series. Ball & Beam. User Manual

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

1. Please do not place the display screen towards the ground. 2. Please avoid heavy impact or drop onto the ground.

3.22 Finalize exact specifications of 3D printed parts.

TRF STEP-DOWN TRANSFORMER USER MANUAL

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

SyncGen. User s Manual

Signal Stability Analyser

Entry Level Wind System. English Français Deutsch Nederlands Espagñol Italiano

Magnetic Stirrers Magnetic Stirr

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

Operator s Manual. Ultegra. Health Scale. Fairbanks Scales by Fairbanks Scales Inc. All rights reserved. Revision 5 06/07

PRODUCT SPECIFICATION Date: VESTEL

Colour Explosion Proof Video Camera USER MANUAL VID-C

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

Product Manual. Designed and Manufactured in the UK by Optikinetics

1-Touch Vibratory Sieve Shaker SS-10

HDCVI Eyeball Camera Lite

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

MICROMASTER Encoder Module

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

SDC-500 Digital Optical Chopper Operating Instructions

VITEK VTM-TLM191 VTM-TLM240

Operating Instructions BTX-1 Series Digital Band Tension Meter

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

10.4" LCD Monitor with Aluminum Front Bezel YPM1040PHB

Product Guide. Analog Panel Meters for use in Electrical Engineering Systems. M Series. Instruments clamping to 35 mm DIN rails W/P/ LSP BWQ BGQ

22" Touchscreen LED Monitor USER'S GUIDE

Twin City Fan & Blower

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

TABLE OF CONTENTS Important Safety Instructions Package Content Setting Up the Display Trouble shooting Specifications Product Dimensions

HDCVI Camera User s Manual

Instruction manual. KUZMA 4POINT 14 inch TONEARM Serial Number:

BM-A1-2SHD MKII. Ver1.1 BM-A1-2SHD MKII. 2 Channel Digital Audio Monitor. User s Guide. Page 1

Monolith Turntable P/N User's Manual

DH5e-V2. Delta 5 On-Camera 4K HDMI Monitor with 3D LUTs. Quick Start Guide. What s Included

PicoScope 3000 Series Automotive User guide

FRQM-2 Frequency Counter & RF Multimeter

DH7-DK QUICKSTART GUIDE. DH7 4K Support HDMI On-Camera Field Monitor Deluxe Kit

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

Color Star Advanced Talking Color Identifier Light Detector and Light Analyzer

Catalogue. Rollers for belt conveyors

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

Delvcam DELV-TOUCH-10 User Guide

PicoScope 4000 Automotive PC Oscilloscopes

DGC-1000A CLAMP-ON GROUND RESISTANCE TESTER

35058-TE. PLJ-6LED-A LED Frequency Display Module Manual

Standard Operating Procedure of nanoir2-s

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Up to 85% higher Service Life due to efficient sealing method.

TABLE OF CONTENTS. Instructions:

Label Applicator HERMA 400

BM-A2-4SHD MKII. Ver Channel Digital Audio Monitor. User s Guide. Page 1

E X P E R I M E N T 1

Safety Precautions and Maintenance

NEO-STB-0004 Neo-Flash 300 RGB User Manual

Model KBF 1020 Constant climate chambers with large temperature / humidity range

CTC Series. Compact Temperature Calibrator

IMPORTANT SAFETY INSTRUCTIONS

UltraTwist. Product Description. Instruction Guide

Tube Roller Shakers. User Guide. Version 1.2

USER MANUAL. EMF Meter. Model EMF510. Additional User Manual Translations available at

VXF17 QUICKSTART GUIDE. 17" Full HD 3G-SDI/HDMI Rackmount Studio and Field Monitor

2013, 2014 Hewlett-Packard Development Company, L.P.

Photovoltaic Module Installation Manual (IEC)

Marshall. M-CT5 Camera-Top Monitor Owner s Manual M-CT5. Camera-Top Monitor. Owner s Manual

LED Spot 300W. Please read this user manual before your operation

QuickSpecs. Models RB146AA#ABA Standard Configuration RB146AT#ABA Promotional Part Number (SmartBuy)

Transcription:

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Please read the user manual before operation. PAGE 1

Content 1. Company Profile... 3 2. Product Introduction... 3 3. Operation Instruction... 4 4. Calibration... 15 5. Maintenance... 16 6. Order Information... 17 PAGE 2

1. Company Profile BEVS Industrial Co., Ltd. is a leading developer & manufacturer that specializes in coatings, ink, painting, resin testing instruments and laboratory whole solution. We offer the complete and unique products in this field to meet customer's challenging demands of today and tomorrow, the products are complied with the standards of ISO, ASTM, DIN, BS, EN etc. With strong supports and hard work by lots of end-users and worldwide agents, BEVS become more and more famous in the world and provides more competitive values for our customers. 2. Product Introduction BEVS 1306 Intelligent Pendulum Hardness Tester is a fully automatic, touch-screen controlled instument for the measurement of flat test panels for coatings, paints, etc. The Persoz pendulum or Konig pendulum used in this product is measured according to the standard ASTM D 4366, BS 3900 E5, DIN 53157, ISO 1522, NF T30-016, GB / T1730. The test principle is as follows: The pendulum rod is placed on the test surface of the test panel. The two steel pendulums of the pendulum are in contact with the test surface. The pendulum motion is performed. The test surface with different hardness reflects different swing times, and the harder the coating is, the more the damping is. Features: * The test process is fully automated. The organic glass cover is automatically raised up and down. The test panel platform automatically lifts and hangs the swing bar. The shift lever mechanism automatically sets the swing bar to the corresponding angle and automatically releases the swing bar for testing. * Automatically identify the pendulum type and start counting. * Digital recognition of level conditions makes sure high precision. * With temperature and humidity sensors. PAGE 3

* High-precision guide rail ensures smooth movement and low noise. * 4.3 inch touch screen and user-friendly interface. * Data saved, and can be connected to a computer for output. 2.1 Technical Specification Dimension: L445*W350*H750mm(with cover open: 1270mm) Mass: 30kg Test Panel: L(70-200mm)*W(80-100mm)*H(1.5-10mm) Voltage: 100-230V(50/60HZ) Power: Max 50W Type Persoz König / Mass 500±0.1g 200±0.2g Ball Diameter SØ8mm SØ5mm Distance between Ball 50mm 30mm Deflection Angle 12 ~4 6 ~3 Oscillation period 1±0.01s 1.4±0.02s 3. Operation Instruction 3.1 Note 3.1.1 Please keep the package for future use if possible. 3.1.2 Please read this manual before operation and keep it 3.1.3 Do not open the instrument housing or motion mechanism housing. 3.2 Safety Instruction PAGE 4

3.2.1 Please read all warnings on the instrument. 3.2.2 Ensure the voltage right. 3.2.3 Do not tear down the instrument on you own. 3.2.4 Organic glass cover can t be move manually. 3.2.5 Be careful while taking the pendulum, it is sharp. Keep it good and get a new one while damaged. 3.2.6 Ensure cover inside clear to operate. 3.3 Operation Environment Ensure the instrument at a proper environment, temp.: 10 ~35, humidity 15~85%, no condensation, wind speed: 0-0.2m/s. 3.4 Placement Ensure the instrument at a horizontal level and enough space for the operator. Calibrate the level every time while moving the instrument. 3.5 Power Supply Ensure earth line connected, input voltage: 100~230V, 50~60HZ 3.6 Operation Steps 3.6.1 Product Structure PAGE 5

Figure 1 1 Shell 6 KONIG Pendulum 2 Touch Screen 7 Hanging seat for pendulum 3 Organic glass cover 8 PERSOZ Pendulum 4 Device of offsetting pendulum angle and 9 Hanging seat for standard glass releasing 5 Device of lifting the pendulum 10 Adjustable footpad 11 Power input 3.6.2 Explanation Under normal circumstances, König pendulum's result time is close to half of the PERSOZ pendulum's. From this point of view, the PERSOZ pendulum is considered to have a better resolution than the König pendulum; however, the PERSOZ pendulum slips on hard coatings due to its lower center of gravity. It will affect the actual measurement accuracy to some extent. It is generally believed that the König pendulum is more suitable for the PAGE 6

determination of hard coatings, and the PERSOZ pendulum is more suitable for the determination of soft coatings. Due to the differences in structure, weight, size, oscillation period and swing between the two pendulums, and the complex elastic and viscous changes under the interaction between the pendulum and the coating, the two pendulums do not have equivalent conversion relationship of measurement results. 3.6.3 Steps 1) Power on Place the instrument properly according to 3.2-3.5 and turn the switch on. 2) Main Interface After booting, the instrument enters the main interface as shown below. Click Settings to set and adjust the related parameters, up and down button controls the cover. Press the start button, the instrument will automatically determine if the test conditions have been reached or not. (Like with cover closed or not). The instrument warns when not reaching the operation conditions. The stop button can stop all the current operations at any time. 3) Open Cover Click Up button to open it. Figure 2 4) Place test panel and pendulum There are two holes on both sides of the steel balls of the two pendulums. When placing the PERSOZ pendulum, ensure the holes mount onto the pins on the hanging shelf as shown below (KONIG pendulum, the same way to hang). Place the test panel on the test platform from right to left. PAGE 7

Figure 3 5) Level adjustment Note: It is not necessary to adjust the level every time, instrument can be self-tested whether it is in the horizontal state or not. If there is a warning, please adjust it. BEVS 1306 adopts high-precision electronic level meter to monitor the horizontal status. It can display the status of deviation from four foots. Adjust the four footpads to control the horizontal status. Figure 4 Click Settings button on the main interface to enter the setup page of level adjustment as pic below. Adjust the footpads to make each value as close to 0 as possible. 0 means that there is no deviation, and it reaches the full level status. The bigger value is, the bigger deviation is. PAGE 8

Figure 5 Figure 6 6) Pendulum type setting Please see below, choose the type you need. It is no need to set it when auto mode on. Figure 7 PAGE 9

Figure 8 Auto mode will detect the pendulum type automatically. When the pendulum is placed correctly, the system will recognize and do the measurement accordingly. 7) Close the cover by clicking Down button. 8) Start measurement Start measurement (the instrument will check whether the above step has been executed), when the self-test passes, the test panel platform will be lifted, and test panel will hold up the pendulum to a limited height, pendulum separates from pins. Figure 9 PAGE 10

When the test panel platform rises to a limited height, the waiting time (called the Y axis delay time) can be set up, and the free automatic dialing rod motor is then started to load the corresponding pendulum to a certain angle. Here we can set the waiting time (called the X axis delay time), then release the pendulum to start the swing motion of the pendulum. As shown in Figure 10 (can be set from Figure 6, click system settings and click system data (Figure 16)), this page can set whether to automatically store test data and instrument vibration alerts. Figure10 When the instrument is tested automatically after the waiting time, the test process of the PERSOZ pendulum is shown as shown in Figure 11. The lever device will dial the swing pointer to 12 degrees, then release the pendulum, the pendulum will swing freely, and the counter and the timer begin to calculate at the same time. The pendulum gradually decays until the amplitude of the pendulum is reduced to 4 degrees, counting and timing are completed, and the measurement results are obtained. Figure 11 PAGE 11

The correct placement of the König pendulum is the same as that of the PERSOZ pendulum. Please refer to the 3.6.3.4 instructions. The effect is shown in Figure 12. Figure12 König Pendulum test process is shown in Figure 13. The lever device will dial the swing pendulum to the position of 6 degrees, and then release the pendulum after the static setting, the pendulum will swing freely, and the counter and the timer begin to calculate at the same time. The pendulum gradually decays until the amplitude of the pendulum is reduced to 3 degrees, counting and timing are completed, and the measurement results are obtained. Figure13 9) Testing Result In the main interface, the pendulum type will be displayed in real time, and the working state and test results are shown in Figure 14. If the data is automatically stored, you can also view all the test data shown in Figure 15 at the setting of the interface. PAGE 12

Figure14 Figure15 Factors that affect the results of the testing: *The level of the platform will affect the stability of the pendulum, and the level must be set as far as possible. *The presence of air will affect the oscillating period of the pendulum. The cover must be closed and keep the environment free from wind when working. *Planeness of the test panel, if the surface of the test panel is not smooth, the horizontal condition is invalid. PAGE 13

*The swinging steel ball remains clean. Dirt or oil stains will affect the normal damping effect of the coating on the swing of the pendulum. 10) System Setting Click the setting button in main interface to enter the setting interface (Figure 6) click the system button to enter the system settings (Figure 16) to set the screen brightness and open or close the buzzer and open or close automatic energy saving Figure16 Click on the system to view the serial number and software version of the instrument and date of production. (Figure17) Figure17 PAGE 14

3.7 Instrument verification The verification of the instrument shall be carried out according to the requirements of the 3.6 operation guide, and the standard glass panel shall be used for operation. 3.7.1 The whole testing should be carried out under the conditions of laboratory temperature and humidity (temperature 23±2 C, relative humidity 50±5%). 3.7.2 Clean the surface of the standard glass panel, clean the surface with a small amount of clean alcohol with cotton cloth. No oil stains or dirt can be found on the cleaning surface. 3.7.3 Put the standard glass panel on the test panel platform 3.7.4 Select the required pendulum, use cotton cloth to clean the surface of steel ball on the rotating shaft, test by 3.6 operation guide. The following table data are standard parameters. The test must be carried out in three different positions on the same standard glass panel. Finally, the average value is taken. PERSOZ Pendulum König Pendulum Swings period 1±0.01s 1.4±0.02s Damping time 430±15s 250±10s on a standard glass panel The number of oscillations on a standard glass panel 430±15 172-185 If there are obvious different results in the case of verification, it is necessary to check whether all the components are clean, the position is correct, and whether there are external causes affecting the operation (including temperature, humidity, level, air flow, vibration, etc.). 4. Calibration 4.1 BEVS1306 Pendulum Hardness Tester has been calibrated before the factory. 4.2 The calibration cycle is recommended for one year under normal use. 4.3 The Pendulum Hardness Tester takes the number of times and the time as the measurement result, and the state of the two pendulums directly determines the accuracy of the result. Calibration is used only by reference to standard parameters. 4.4 The calibration operation is calibrated according to the operation guide of the test PAGE 15

before the test of instructions 3.6. If the deviation between the test results and the standard parameters is large, check whether the two pendulums are deformed or loosened, and any loosening of the pendulum or the abnormal connection will lead to a certain degree of change in the pendulum. If there is any looseness, then it cannot meet the standard requirement after locking. Please contact us for after sale service. 4.5 KONIG pendulum changes the swing period. The upper cylinder is a counterweight. As shown in the figure below, adjusting its height can change the swing interval. 4.6 The swings period cannot be changed by the pendulum. 5. Maintenance The regular maintenance is required for BEVS 1306 Intelligent Pendulum Hardness Tester. This responsibility is borne by the customer, not a warranty obligation. 5.1 The two steel ball of Pendulum is wiped only when it needs cleaning. 5.2 After one day's operation, the two Pendulums should be placed on the dedicated idle rack, and avoid excessive collision when placed, don t leave the testing panel in the machine. 5.3 After a day's test, it is necessary to clean up the workspace, avoid leaving foreign objects, and ensure that the sensors are not damaged. 5.4 The instrument must be kept clean, dirt or oil stains must be cleaned in time. 5.5 Ensure the lubrication state of each operating mechanism of the instrument, and use the lithium grease lubricating oil once every 1 year. PAGE 16

6. Order Information BEVS 1306 Intelligent Pendulum Hardness Tester (K and P) BEVS 1306 /1 Intelligent Pendulum Hardness Tester (K) BEVS 1306 /2 Intelligent Pendulum Hardness Tester (P) PAGE 17