120cm (4x36 Watt) incl. Splitter Instruction Manual

Similar documents
Instruction Manual. from software version 1.0 (instruction version 1.3) Internet:

LED Spot 300W. Please read this user manual before your operation

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

LED Thunder S-150 Code 1097

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

LED IP65 Slimline Par RGBWA +UV 7x12W

1440/2880 HP RGB+WW+CW

Truss Light COB LED 30W

Cyclo Series. user manual. MartinArchitectural

HEX16 Strip User Manual

Operating Instructions Dimmer for V Incandescent Lamps

Design LED 36. Elation Professional 4295 Charter Street Los Angeles, Ca Rev. 11/17/06

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

QLOCKTWO CLASSIC. Instructions for use

SquareLED - Aura Bar & Matrix Beam Light 100

Led Dynamic DMX Tri Curtain Manual

Mini LED Pin Spot Light Model: PLS00571

DMX Operator 192-channel lighting controller

LED PAR 64 floor 12x8W RGBWAUV incl. remote

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

Spectra Batten (Order code: LEDJ95)

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

Figure 1: Device components

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Instruction Manual. from software version 1.00/30 (Instruction version 1.00) Internet:

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Design LED 36WA. Elation Professional 4295 Charter Street Los Angeles, Ca Rev 3/08/07

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

USER MANUAL. TS-3 DMX-Scanner. For your own safety, please read this user manual carefully before you initial start-up.

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc..

USER MANUAL Full HD Widescreen LED Monitor L215ADS

LED Spere Direct Control 30 ORDERCODE 41125

USER MANUAL Full HD Widescreen LED Monitor L215IPS

LED MODULES READYLINE DL

Instruction Manual. from software version 1.07 (instruction version 1.11) Internet:

Instruction Manual. from software version: 1.0 (Instruction version: 1.0) Internet:

Galaxias. Flex LED display. User Manual

LED-PAR200B USER MANUAL. COLORsplash 200B

Instruction Manual. from software version: 1.18/18/12/10/n (Instruction version: 1.0) Internet:

Instruction Manual. from software version: 1.48 (Instruction version: 1.3)

USER MANUAL Table of Contents

Electro Magnetic Compatibility (EMC) Warning. Important notes for users in the U.K. FCC declaration. Caution. Fuse

Design LED 60 Strip WA. Elation Professional 6122 S Eastern Ave Los Angeles, Ca Rev.

TVAC20000 User manual

Yoke Safety cable loop. Up Light Bulb

PLL2210MW LED Monitor

IPS LED Monitor. (LED Monitor*) OWNER S MANUAL

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

FiliBuster. User Manual

LED LCD MONITOR. (LED Monitor*) OWNER S MANUAL

6X3W TRICOLOUR LEDS COMPACT PROJECTOR

Model KT 53 Cooling incubators with thermoelectric cooling

USER MANUAL Full HD Widescreen LED Monitor L236VA

4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL. Please read this manual thoroughly before use, and keep it handy for future reference.

Quick Reference Guide

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

3B SCIENTIFIC PHYSICS

Model KBF 115 Constant climate chambers with large temperature / humidity range

DMX LED light effect with 4 lenses

Table of Contents Precautions... 2

TECHNICAL INFORMATION

PL2410W LCD Monitor USER'S GUIDE.

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

PLL1920M LED LCD Monitor

ETC Quick Guide. Source Four LED Profile

LED Pixel Track Pro ORDERCODE 42205

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

USER MANUAL Table of Contents

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT

Model KT 115 Cooling incubators with thermoelectric cooling

PRODUCT SPECIFICATIONS

LIGHT COPILOT II. elationlighting.com Internet:

LCD Thermometer / Clock S No. 1253

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

PART 1 PRODUCT (GENERAL)...1.

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

Stratos Duo RGB. User Manual. Order code: EQLED371

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

Model KBF 1020 Constant climate chambers with large temperature / humidity range

VGA & Audio over CAT5 Distribution Series

Waterfall 250 Pro. Elation Professional 4295 Charter Street Los Angeles, Ca Rev. 12/28/05

User s Guide L1718S. LCD Computer Monitor

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

Transcription:

120cm incl. Splitter Instruction Manual

Table of contents 1 Description of Device and Functions... 3 1.1 Safety Instructions... 4 2 Preparation and Installation... 5 2.1 Mounting... 5 2.2 Secure the... 5 2.3 Connections... 5 2.4 Adjust the DMX- Address... 6 2.5 Channel configuration and operation mode... 7 2.6 DMX-Table... 7 3 Operating... 7 4 Maintenance / Tube change... 8 5 Technical Specification... 8 5.1 Startube 4 HiRes... 8 5.2 Assembly and dimensions... 9 5.3 General view... 9 5.4 Accessory: Splitter... 10 2 Version 1.1 GLP German Light Products GmbH

1 Description of Device and Functions - The is a fluorescent tube lighting concept for professional architecture and stage lighting. - The system consists of 4x T8 fluorescent tubes 36W in the colors red, green, blue and white. - Each of the 4 tubes of the is individually controllable over a DMX- 512 channel. - Internal high resolution control electronics allows a continuously and smooth dimming between 0% and 100%. - By means of additive color mixing with a very high resolution, one receives a homogeneous color mixing behavior with very high luminous efficiency. - Moreover the tubes show a very fast responding behavior, with which the system suits also application like fast running light programs and stroboscope-similar effects. - In Seven-Channel-Mode the possibility exists to turn off the pre-heating of the tubes, to choose between two dimmer curves, to turn on a stroboscope effect and to regulate the maximum brightness of all tubes. - The DMX start address is adjusted simply over keys at the system and directly indicated over the display. In Seven-Channel-Mode the Display goes out 10 seconds after the last key press to enable operation in darker settings. - The mode switchover takes place by pushing two keys of the Display simultaneously. (100 and 10: Four-Channel-Mode, 100 and 1: Seven-Channel- Mode ) - The fourth fluorescent tube serves the background brightness increase in the white color. Furthermore also the possibility exists to exchange this tube by another color to obtain there a higher brightness. - A further advantage is the lockable single-connector-system and the very low power consumption, which is reached by a very good compensation. Thus it is possible to attach up to 15 Splitter at each single 16A phase. in a row connected to one - Integrated threaded bushes M10 for a clamp, a CAMLOC quick-lock-system, a fitting for a safety rope and the removable feet simplifying the handling within the tour exercise. GLP German Light Products GmbH Version 1.1 3

- By the possibility to mount the devices both, lengthwise as well as in transversal direction without any gaps, large coherent shining surfaces can be constructed. - As accessories, cable connections are available in the lengths 1m, 2m, 5m, 10m and 20m. 1.1 Safety Instructions The is a High-Tech product. To guarantee a smooth operation it is necessary to keep the following rules. The manufacturer of this device will not take responsibility of damages through disregard of the information given in this manual. Warranty adjustments will be canceled. 1. Never try to repair or to dismantle the yourself. Opening the internal housing can lead to current impacts or other injuries. Turn for arising problems always to an authorized specialist dealer or directly to GLP. 2. The is exclusively meant for the use in the internal area. Never use or store the system out of doors. 3. When installation the devices attention is to be paid to a sufficient temperature heat sink. Take advised from the GLP - support if an installation in restrained or badly ventilated conditions is planned. 4. Protect the equipment against humidity and wetness as well as against increased vibrations. 5. Unplug the from the AC outlet before any service. 6. To allow a secure operation, follow also the installation guide described in chapter 2.1. Operating the without suited safety aids like Safety cables or clamps/hooks can increase the risk of accident. 7. The installation should be done by qualified staff only. You need to pay attention to the common rules of technology that are not explicit mentioned in this manual. 8. Use only original spare parts. Any structural modification will cancel all warranty adjustments. 4 Version 1.1 GLP German Light Products GmbH

2 Preparation and Installation 2.1 Mounting The can be mounted in any arbitrary position without any gaps. To ensure a safe installation under all circumstances, the system offers various possibilities like screw-on standings and assembly angle, different attaching by means of a hook, classical M10 hook or CAMLOC quick-lock-systems. 82 2.2 Secure the Regardless of the rigging of the 835 770 640 700 4x M10 you have to use a stipulated safety wire. Therefore you have to thread a safety wire through the intended application at the fixture and connect it with the truss-support. Pay attention to a safe and proper fastening. 2.3 Connections Pay attention to the regulations of: BGV C1 (former VBG 70) and DIN VDE 0711-217! The installation should be done by qualified staff only. You can connect up to 15 in one row. The Splitter is therefore connected to a single 16A phase. Also the DMX signal for all 15 is attached directly to this device. Power and the DMX signal will be both transmitted over the multi-core cable, connected firmly with the system. For forwarding the power and DMX signal, differently manufactured cables are available as accessories. During mounting and dismounting, the system must be disconnected from the mains supply. Otherwise the connectors can by damaged! GLP German Light Products GmbH Version 1.1 5

2.4 Adjust the DMX- Address To adjust the DMX- (Start) Address please use the three keys underneath the display. Key 100 for the 100 digits. Key 10 for the 10 digits. Key 1 for the 1 digits. Counting upwards. Each Channel 1 = white Channel 2 = red Channel 3 = green Channel 4 = blue Example: unit uses four or seven DMX channels. in Seven-channel-mode: Channel 5 = pre-heating off, dimmer curve selectable Channel 6 = Stroboscope effect Channel 7 = superior dimmer In Four-channel-mode In Seven-channel-mode no. 1 DMX Channel 001 DMX Channel 001 no. 2 DMX Channel 005 DMX Channel 008 no. 3 DMX Channel 009 DMX Channel 015 6 Version 1.1 GLP German Light Products GmbH

2.5 Channel configuration and operation mode The comes with two operation mode which vary in functionality and number of DMX channels. In the compatibility mode (Display Key 100 and 10 pushed simultaneously; Display shows H0 ) four DMX channels are needed. Thereby each channel controls the brightness of a tube. Thereby the pre-heating of the tubes is on durably. In Seven-channel-mode (Display Key 100 and 1 pushed simultaneously; Display shows H1 ) channel 5 is intended to be used to turn of the pre-heating of the tubes and choose between old and new dimmer curve. Channel 6 conduces to adjust the stroboscope effect. Channel 7 controls the maximum brightness of all tubes. Thereby the brightness depends on the settings of channel 1-4. 2.6 DMX-Table Channel 1 Channel 2 Channel 3 Channel 4 In Seven-channel-mode Brightness of the first tube in 255 steps Brightness of the second tube in 255 steps Brightness of the third tube in 255 steps Brightness of the fourth tube in 255 steps Channel 5 0-99 linear dimmer curve 100-199 dimmer curve softer in lower sector 200-255 pre-heating of the tubes off Channel 6 0-15 tubes OFF Channel 7 3 Operating During operating the 16-239 strobe; frequency: 0.2Hz - 50Hz 240-255 tubes ON Maximum brightness of all tubes in 255 steps the following points are to be considered: a) After the system is switched on, the tubes need a certain time (a few minutes) to reach their operating temperature. Easy flickering is not to be avoided in this time. b) After this period the system should operate smooth. If you have still those flickering and glowing effects at DMX value 000, please turn around the main plug at the Splitter by 180 (zero-lead and phase exchange). GLP German Light Products GmbH Version 1.1 7

4 Maintenance / Tube change Dependent on the operating conditions you should clean the in regular intervals. Make sure that the system is disconnected from the mains supply. The housing can simply be cleaned with a dampish cloth. The fluorescent tubes should be abraded with a lint-free cloth very carefully. For your own protection it is recommendable to wear safety gloves. To change a fluorescent tube turns it carefully by approx. 90 in the socket. For this e.g. loop a narrow band leather around the tube ends and slue it around carefully. If the vertical slot of the socket is visible the tube can be then removed. Insert the tube in reverse order again. New tubes should be operated approx. 100 hours for reaching an optimal operational behavior on full efficiency. Only fluorescent tubes of the type T8, 36W must be used! 5 Technical Specification 5.1 Startube 4 HiRes Power consumption RGB- Color mixing system DMX-512 control max. ambient temperature 45 C Dimensions WxLxH Weight CAMLOC- quick-lock-systems each system 4x T8 fluorescent tubes 36W red, green, blue, white 4 DMX channels each 0-100% dimming 1237mm x 133mm x 104mm (with mounted feet +65mm) 11 kg Connecting system over multi-core cables and Splitter system 8 Version 1.1 GLP German Light Products GmbH

5.2 Assembly and dimensions 82 5.3 General view A 835 770 640 700 4x M10 1237 1302 A B 93 B 130 161 GLP German Light Products GmbH Version 1.1 9

5.4 Accessory: Splitter 10 Version 1.1 GLP German Light Products GmbH

GLP German Light Products GmbH Version 1.1 11