Innovations in PON Cost Reduction

Similar documents
DOCSIS 3.1 Development and its Influence on Business

Automated Connector Processing Tackles Exploding FTTP Connector Market

Cost Effective High Split Ratios for EPON. Hal Roberts, Mike Rude, Jeff Solum July, 2001

Re: Implementation of Section 304 of the Telecommunications Act of 1996, Commercial Availability of Navigation Devices, CS Docket 97-80

Technology and Status Summary. Burlington Telecom Advisory Board March 11, 2015

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

ED5229GT-E Series. Page 1 of 8

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

Datasheet. Licensed Backhaul Radio. Models: AF-11FX-L, AF-11FX-H. Full-Duplex, Point-to-Point Radio. 11 GHz Frequency Operation

DOCSIS 3.1 roll Out First Lessons Learned DOCSIS 3.1 roll Out First Lessons Learned

Hands-On Real Time HD and 3D IPTV Encoding and Distribution over RF and Optical Fiber

Development of optical transmission module for access networks

Paper review on Mobile Fronthaul Networks

Illinois Telephone Users Group. Peoria, IL June 6, 2007

Opti Max Nodes Digital Return System

ED5229GT-E/GTRE Series

Market- versus Technology-Driven R&D in Optical Communications Industry. Winston I. Way, April 23, 2008

TriAccess Solutions. Advanced CATV & High-Speed Data

Fronthaul solutions

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

THE FUTURE OF NARROWCAST INSERTION. White Paper

OpticalProducts. Illuminating Your Network. Testing the World s Networks

Proposed NG-EPON wavelength planning decision flow. Ed Harstead, member Fixed Networks Division CTO, Alcatel-Lucent January 2014

REPORT/GATE FORMAT. Ed Boyd, Xingtera Supporters: Duane Remein, Huawei

METHOD, COMPUTER PROGRAM AND APPARATUS FOR DETERMINING MOTION INFORMATION FIELD OF THE INVENTION

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

PIN-PD based ONU for 10GE-PON (3)

International Trends in Broadband Service. ICTC International Forum Hangzhou, China October 20, 2016

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

Agilent 81600B Tunable Laser Source Family

RF RETURN OPTIONS AN ENABLENCE ARTICLE WRITTEN BY JIM FARMER, CTO. September,

Integra series. Integra series comparison, v1.43, November All data are subject to change without prior notice Page 1

Symmetrical Services Over HFC Networks. White Paper

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

Fiber to the Home. the New Empowerment. Paul E. Green, Jr May 19, Ref.: Book of same title, John Wiley and Sons, 2005

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

GPON ONU Triplexer Transceiver

Verizon New England Inc. Application for a Compliance Order Certificate for Rhode Island Service Areas 1 and 4. Exhibit 3

PROMAX NEWSLETTER Nº 22

CABLE MODEM. COURSE INSTRUCTOR Prof.Andreas Schrader

How to overcome/avoid High Frequency Effects on Debug Interfaces Trace Port Design Guidelines

100g cfp Health check Jean-Marie Vilain, Product Specialist, Transport and Datacom

CHP Max Headend Optics Platform CHP CORWave II

REGIONAL NETWORKS FOR BROADBAND CABLE TELEVISION OPERATIONS

WDM Video Overlays on EFM Access Networks

PROMAX NEWSLETTER Nº 25. Ready to unveil it?

Adding the community to channel surfing: A new Approach to IPTV channel change

Sharif University of Technology. SoC: Introduction

FOGGY DOCSIS AN ENABLENCE ARTICLE WRITTEN BY JIM FARMER, CTO APRIL,

Key Performance Metrics: Energy Efficiency & Functional Density of CMTS, CCAP, and Time Server Equipment

BUSINESS SYSTEMS MONITORING

EPON ONU Triplexer Transceiver

UTAH 100/UDS Universal Distribution System

Challenges of Launching DOCSIS 3.0 services. (Choice s experience) Installation and configuration

1/31/2009. Technical highlights session PRODUCTS & SERVICES Summary. Sam Tagliavore PBN-FTTX

An Effort to Create Multi-vender Environment for 100 Mb/s P2P optical Ethernet Access in Japan

OMNISTAR GX2. GX2-LM1000E Series 1310 nm Broadcast Transmitter DATA SHEET BENEFITS. 1 GHz bandwidth

FORWARD PATH TRANSMITTERS

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Course Title: High-Speed Wire line/optical Transceiver Design

TriAccessTM. Solutions for Advanced CATV & High-Speed Data

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

Ponderosa is expandable by 8 input and/or 8 output increments up to 64x64 in a 4RU frame. Typical Configurations:

Ultrafast Fibre UFB Services Agreement. Price List

DROP HARDENING. January 21, 2015

SFP-Bxx-ttrr. Up to 80km Sinlge-Mode SFP Transceiver. Features. Applications. Benefits

Module 7. Video and Purchasing Components

Altera's 28-nm FPGAs Optimized for Broadcast Video Applications

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

INTERNATIONAL TELECOMMUNICATION UNION

GIVING HFC A GREEN THUMB

Alcatel-Lucent 5620 Service Aware Manager. Unified management of IP/MPLS and Carrier Ethernet networks and the services they deliver

UCR 2008, Change 3, Section 5.3.7, Video Distribution System Requirements

Appendix J: New Generation Networks C NGNs. 2 Major Bell Strategies. 2. AT&T: aggressive DSL+, Fiber to the neighborhood. 1.

MAPON digital video distribution in the European ACTS CRABS Project: simulation and experiment

WaveReady WRT Gbps Extended-Reach DWDM Tunable Transponder with XFP Client Interface

XRAN-FH.WP.0-v01.00 White Paper

3G-SDI Video SFP Rx Optical Receivers

Mitsubishi Electric Optical Devices: The Key to Connecting Information Networks in the Future.

Datasheet. Full-Duplex, Point-to-Point Gigabit Radio. Models: AF-24, AF-24HD, AF-5, AF-5U. High Performance Wireless Backhaul

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

TEPZZ 889A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2017/35

Prisma D-PON System ONT and Upstream Receiver

System Evolution with 100G Serial IO

Winning Metro 100G. 100G Price Challenge. Daryl Inniss, PhD. ECOC 2013, Market Focus. 23 September 2013

Front End Electronics

TAHOMA opengear frame

Power over Coaxial Extender Kit VC-205PT & VC-205PR

Amplifiers STARLINE 2000 Broadband Telecommunications Distribution Amplifier [BT*/*]

SYSTEM DESIGN - NEXT GENERATION HFC

Prisma D-PON System 1550 nm Downstream Transmitter and EDFA

Casa Systems C3200 CMTS

MTS/T-BERD 8000 Platform

CWDM / 3 Gb/s Medium Power SM Video Digital Diagnostic SFP Transceiver

Innovative Fast Timing Design

THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO

Datasheet. Full-Duplex, Point-to-Point Gigabit Radio. Tel: +44 (0) Fax: +44 (0)

Headend Optics Platform (CH3000)

Transcription:

Innovations in PON Cost Reduction Abstract Passive Optical Network (PON) deployments become a reality only when the promised price of a Fiber To The Premise (FTTP) network met the carrier s objectives for a viable business. Since the number one feature for PON is cost, equipment vendors had to aggressively forward price their products to win the carrier s business. This has resulted in pressure to drastically cost reduce the products through design and manufacturing innovations. For a healthy, long-term industry, everyone in the PON food chain must be profitable. Can component technology alone satisfy the costs demand as well as the performance requirements? Are there product architectural improvements or network enhancements that are worth the effort to meet the cost targets? This paper will address the PON and PON component technology that can reduce the cost of the current equipment implementation by up to 50%. Aspects that this paper will address are the Optical Network Termination (ONT) Bill Of Material (B.O.M.) and the PON itself. Since the optical components have the largest B.O.M. impact, integration of the various optical and PON chip functions as well as some common ONT functions can offer up to a 20% cost reduction to the ONT. The encouragement is that such innovations can be realized within the next two years. Regarding the PON itself, an increase in PON speed, efficiency and split ratio can provide up to 40% overall cost reduction. Although some carriers have already established their Optical Distribution Network (ODN) policy based on previous technology, the largest market opportunity for PON, China, has yet to be established its ODN policy. Such details pertaining to speed and split ratios will influence such carriers for planning their PON ODN and selecting their technology. PON System Factors There are three key system factors that affect the total cost of a PON solution: PON Split ratio for Optical Line Terminal (OLT) cost efficiency PON Speed for more subscribers per PON and/or higher speed services per subscriber PON Protocol - for efficient use of PON capacity Although much focus is put on the direct per subscriber cost associated with ONT, figure 1 shows that the OLT is a contributing factor even in split ratios higher than 32. Setting the cost for an OLT at $900 and an ONT at $100, figure 1 shows that going from a 32 to 64 split ratio, an 11% cost reduction for the subscriber cost is realized. This simple calculation of OLT cost split + ONT cost illustrates how much of an effect the OLT will have on per subscriber costs. Carriers currently looking at PON ought to consider supporting high split ratios provided that the Optical Distribution Network (ODN) distance requirements can be achieved cost effectively. The PON s speed becomes a significant cost factor as the total sustained rate for subscribers start to approach the maximum capacity of the OLT. To illustrate the effect of PON downstream speed and efficiency on cost, the downstream sustained speed per subscriber in a 10,000 FTTP network will be modeled. The cost of the OLT and ONT equipment will be the same for each PON speed at $900 and $100 respectively. The result of the model is illustrated in figure 2-1 -

whereby the subscriber cost difference is significant. The reason is highlighted in figure 3 where the number of OLTs required for each subscriber data rate for each PON speed has a direct bearing on the per subscriber costs. As seen in figure 3, the outline of the number of OLTs tracks the per subscriber costs in figure 2 for each PON speed. $600 $500 $400 $300 $200 $100 $0 45% 40% 35% 30% 25% 20% 15% 10% 5% 0% 2 4 8 16 32 64 128 Split Ratio Cost per subscriber % Cost reduction from previous split Figure 1 Effect of Split Ratio. OLT = $900, ONT = $100 $300 $250 $200 $150 $100 0.5 Gbps PON 1 Gbps PON 2 Gbps PON $50 $0 10 20 30 40 50 60 70 80 90 100 Mbps per Subscriber Figure 2 PON Speed Subscriber Cost. OLT = $900, ONT=$100-2 -

2500 2000 1500 1000 0.5 Gbps PON 1 Gbps PON 2 Gbps PON 500 0 10 20 30 40 50 60 70 80 90 100 Mbps per Subscriber Figure 3 PON Speed OLT Requirements for Sustained Subscriber Rates Using the same 10,000 home model for a 1Gbps PON and fixing the subscriber downstream data rate at 100 Mbps, the PON s efficiency bearing on cost can be determined. As shown in figure 4, improving the downstream efficiency form 75% to 95% yields a cost savings of $29 (i.e $229 - $200) or 13% per subscriber. Once again, the cost impact is due to the number of OLTs required to service the network of 10,000 homes. 2500 $300 2000 1500 1000 500 0 55% 60% 65% 70% 1Gbps PON Efficiency 75% 80% 85% 90% 95% 100% $250 $200 $150 $100 $50 $0 OLTs Costs/Sub Figure 4 1Gbps PON Efficiency Effect. OLT = $900, ONT = $100. Subscriber rate = 100 Mbps. Modeling all variations for the effects of PON speed, efficiency and split ratio and putting them on to a single diagram would yield a many axis graph that would be very difficult to interpret. Rather, a simple comparison of BPON, EPON and GPON has been done. As a result of the three factors just considered, it was shown that GPON can be as much as 40% cheaper than EPON for 100 Mbps downstream subscriber service. 1 1 GPON Gets Ready for Primetime. Parsons. FTTH Council North America Annual Conference 2005. - 3 -

ONT Cost Reduction Directions The best investment in PON cost reduction is done at the ONT whereby a dollar saved per ONT is a dollar saved per subscriber. Two critical factors affecting subscriber costs are volume and the ONT design reflected in the Bill Of Material (BOM). ONT volume going from 100K units to 1M units can reduce ONT costs by 30%. For the ONT BOM, a breakdown of the functional blocks and their relative cost for a GPON ONT is shown in figure 5. As can be seen, the dominant ONT cost is associated with the optical transceiver accounting for up to 30% of the B.O.M. With the availability of auto-tuning burst mode laser drivers, it is now possible to design the optical transceiver module in a flattened approach, directly on the PCB of the ONT. This design approach eliminates several items off the cost of the transceiver module; PCB, controller, non-volatile memory for calibration data (Flash memory, or EPROM), packaging, pins and/or socket connector as well as the test and manufacturing costs of the module. The profit of the transceiver vendor, otherwise known as its margin, is also eliminated. The optical block is now be part of the overall test and manufacturing cost of the ONT. It is estimated that this can contribute 30% cost reduction for the GPON ONT optical interface, providing of approximately 10% on ONT cost. Flatten design of the ONT optical interface has not been possible so far. But there are new highly-integrated ASICs coming to the market with ability to automatically compensate for a wide range of aging, temperature and other variables of the lasers & diodes. These GPON PHY ASICs are an essential building block for the design of the flat ONT, eliminating the risks associated with discrete designs. With a burst mode laser driver, a continuous limiting amplifier, a built-in controller and all associated support functions such as PRBS generation, temperature meters, current and voltage drivers, as well as voltage and current digitizers, the advanced GPON PHY ASIC adds the ability to self-calibrate the optical interface after producing the ONT and provide a rich set of monitoring and diagnostic capabilities in the field. Figure 5 ONT Cost of Functional Blocks - 4 -

The promise of high volume is an incentive for chip companies to provide further cost reduction through integration of common functional blocks such as memory, physical layer devices (PHY) and interfaces. The ONT SoC is already a highly integrated component made up of high speed mixed signal technology for the optical interface, PON MAC, control processor, packet processor, Ethernet MAC, and others functions. Although memory is common element across all ONTs, the amount is not. Also, the integration of memory does not offer a significant cost savings since memory is quite inexpensive. Integrating it would also limit flexibility. Functions worthy of integration for the high-volume residential market are common interfaces such as voice and data. The common interface configuration is two ports of voice and one port of data per single home. As a result, the integration of the voice digital signal processor (DSP) function can be done with the subscriber line interface circuits (SLICS) left outside the SoC. This integration will provide approximately a 5% costs savings to the ONT B.O.M. Integration of the 10/100/1000 Mbps Ethernet PHY would provide an additional 4% savings yielding a total savings of 9% to the ONT B.O.M. for the subscriber interface integration. With the integration of common subscriber interfaces as well as the PON PHY, a total ONT B.O.M. cost savings of almost 20% can be achieved. This new optically flattened highly integrated ONT is shown in figure 6. Figure 6 High Integration Flattened ONT - 5 -

The Next 2 Years ITU-T G.984 GPON has emerged as the fastest available TDM PON technology offering a highly efficient 2.5 Gbps transport featuring split ratios up to 128 subscribers resulting in significant network cost savings over BPON (~ 500 Mbps downstream) and EPON (~ 1 Gbps downstream). With interoperability initiatives underway and large service providers promising volume deployment, achieving technology advancements for cost reduction is a natural business evolution. This is precisely what has happened with all standards based broadband deployment namely cablemodem, DSL and WiFi. The first step towards GPON cost reduction has already happened with highly integrated GPON ONT SoC entering the market. Some of the SoC have integrated voice DSPs already. ONT PON PHY chips are now available and flattened optical designs are being evaluated. With further integration of the PON PHY in the SoC, achieving a 20% cost reduction to a typical GPON ONT within the next two years can readily be realized. Dan Parsons is Director of Marketing at BroadLight Inc. (www.broadlight.com). He can be reached at dan.parsons@broadlight.com. - 6 -