DETAILED TEST RESULTS ON SEVEN TOWNSVILLE KONGSBERG TARGETS

Similar documents
TRACE 10 Electronic Shooting Assistant

Capstone Experiment Setups & Procedures PHYS 1111L/2211L

ECE 480. Pre-Proposal 1/27/2014 Ballistic Chronograph

Estimation of inter-rater reliability

Silver Mountain Targets V2 Software Reference Guide. July 22, 2015

SCHEDA TECNICA. Amarro per cavi 13,5mm Amarro per cavi 16,5mm. MS217F00 Amarro per cavi 13,5mm MS218F00 Amarro per cavi 16,5mm

Precision testing methods of Event Timer A032-ET

UC San Diego UC San Diego Previously Published Works

AP Statistics Sampling. Sampling Exercise (adapted from a document from the NCSSM Leadership Institute, July 2000).

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses. Unprecedented design freedom for solid state

Analysis of WFS Measurements from first half of 2004

Broken Wires Diagnosis Method Numerical Simulation Based on Smart Cable Structure

AP Statistics Sec 5.1: An Exercise in Sampling: The Corn Field

Innovative Rotary Encoders Deliver Durability and Precision without Tradeoffs. By: Jeff Smoot, CUI Inc

Chapt er 3 Data Representation

RST INSTRUMENTS LTD.

DRAFT. Proposal to modify International Standard IEC

Linear encoders without bearings incremental System for linear motion feedback

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

Chapter 5. Describing Distributions Numerically. Finding the Center: The Median. Spread: Home on the Range. Finding the Center: The Median (cont.

SAAV contains upgraded MEMS sensors that reduce power consumption and improve resolution.

Common assumptions in color characterization of projectors

R&D White Paper WHP 085. The Rel : a perception-based measure of resolution. Research & Development BRITISH BROADCASTING CORPORATION.

CS2401-COMPUTER GRAPHICS QUESTION BANK

Microbolometer based infrared cameras PYROVIEW with Fast Ethernet interface

CHAPTER 7 BASIC GRAPHICS, EVENTS AND GLOBAL DATA

APPLICATION OF PHASED ARRAY ULTRASONIC TEST EQUIPMENT TO THE QUALIFICATION OF RAILWAY COMPONENTS

JS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA

Creating the Perfect Colorbar

Color Reproduction Complex

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

MOBILE DEFENDERS : QUALITY GUIDE FEBRUARY 2019 MOBILE DEFENDERS QUALITY GUIDE. Shenzhen, China: Our second home.

Fiberglass - Technical Data

Section C Recorders. DPR mm Digital Strip Chart Recorder

LAUREL ELECTRONICS, INC.

Mechanical aspects, FEA validation and geometry optimization

EBU Digital AV Sync and Operational Test Pattern

E X P E R I M E N T 1

Avoiding False Pass or False Fail

The trigger for the New Electromagnetic Calorimeter NewCal

Experiment: Real Forces acting on a Falling Body

Skip Length and Inter-Starvation Distance as a Combined Metric to Assess the Quality of Transmitted Video

Graphing Your Motion

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

Practice makes less imperfect: the effects of experience and practice on the kinetics and coordination of flutists' fingers

User s ManUal NON-CONTACT TACHOMETER. Please read this manual carefully and thoroughly before using this product.

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE

ISOMET. Compensation look-up-table (LUT) and How to Generate. Isomet: Contents:

Assessing and Measuring VCR Playback Image Quality, Part 1. Leo Backman/DigiOmmel & Co.

DEX Fruit & Stem Growth Dendrometer User Manual

Hardcopy. Prerequisites. An understanding of the nature of color and visual communication, and an appreciation of what makes an effective image.

An Introduction to Vibration Analysis Theory and Practice

Statement Of Results For Sound Transmission Loss Tests Performed By Acoustics Laboratory At RMIT University On Behalf Of Polyphen.

Supplemental Material: Color Compatibility From Large Datasets

A quick and dirty magnet design for the magnetized beam LDRD proposal Jay Benesch 10/16/2015

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

DISCLAIMER. This document is current at the date of downloading. Hunter Water may update this document at any time.

Key Maths Facts to Memorise Question and Answer

Apply(produc&on(methods(to(plan(and( create(advanced(digital(media(video( projects.

In-process inspection: Inspector technology and concept

LCLS RF Reference and Control R. Akre Last Update Sector 0 RF and Timing Systems

WHAT'S HOT: LINEAR POPULARITY PREDICTION FROM TV AND SOCIAL USAGE DATA Jan Neumann, Xiaodong Yu, and Mohamad Ali Torkamani Comcast Labs

Spectrum Analyser Basics

THE OPERATION OF A CATHODE RAY TUBE

Overview. Teacher s Manual and reproductions of student worksheets to support the following lesson objective:

RST INSTRUMENTS LTD.

Bootstrap Methods in Regression Questions Have you had a chance to try any of this? Any of the review questions?

Optimization of Multi-Channel BCH Error Decoding for Common Cases. Russell Dill Master's Thesis Defense April 20, 2015

RTPC 12 Simulation. Jixie Zhang Aug 2014

Obtained from Omarshauntedtrail.com

More Info at Open Access Database Process Control for Computed Tomography using Digital Detector Arrays

CR7000. CRT Analyzer & Restorer. Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security.

AskDrCallahan Calculus 1 Teacher s Guide

Measurement Accuracy of the ZVK Vector Network Analyzer

pdf Why CbCr?

2017 MICHIGAN SKILLS USA CHAMPIONSHIPS TASK AND MATERIALS LIST. SKILL OR LEADERSHIP AREA: Television Video Production

CALIBRATION OF SOLUTION SECONDARY CURRENT FOR 9180 controls with SC software PAGE 1 OF 5

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

Commissioning of the ATLAS Transition Radiation Tracker (TRT)

HDCVI Camera User s Manual

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

abc Mark Scheme Statistics 3311 General Certificate of Secondary Education Higher Tier 2007 examination - June series

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

onitoring Bearing Vibration with Seismic Transducers

Choosing an Oscilloscope

ENGINEERING COMMITTEE Interface Practices Subcommittee

Luminaire SIGNATURE SERIES

SCALE & WEIGHT DISPLAYS

RECOMMENDATION ITU-R BT

Axle Assembly Poke-Yoke

3.22 Finalize exact specifications of 3D printed parts.

EDDY CURRENT IMAGE PROCESSING FOR CRACK SIZE CHARACTERIZATION

Moving on from MSTAT. March The University of Reading Statistical Services Centre Biometrics Advisory and Support Service to DFID

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Why t? TEACHER NOTES MATH NSPIRED. Math Objectives. Vocabulary. About the Lesson

Fingerprint Verification System

Preparation of the participant. EOG, ECG, HPI coils : what, why and how

New Filling Pattern for SLS-FEMTO

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

Christie MicroTiles. Technical Frequently Asked Questions (FAQs)

Transcription:

DETAILED TEST RESULTS ON SEVEN TOWNSVILLE KONGSBERG TARGETS February, 06 Peter Smith and David Stewart With extra thanks to Denis Russell Dudley Ford Eric Christie Steve Durham Wayne Swift who put in a lot of time, work, and sweat to make the testing happen. Page

The purpose of the electronic target testing conducted at the Harvey Range Shooting Complex on the 0th February 06 was to :. Establish a rigorous testing method for electronic targets which can reliably assess other methods of target management. Established methods such as shot counts and target records will need modification as shooting styles and accuracy change, and without some standard way to monitor actual target accuracy these may be misleading.. Measure and compare the accuracy of targets of the same make and model in new, slightly degraded and very degraded condition. The targets tested were all Kongsberg Model HH purchased within the last two years. Testing Procedure The faces of the selected targets had a horizontal and vertical line marked through the respective centre points of the sides to indicate the geometric centre of the target. Test sheets were 00mm square sheets of white Corflute of 5mm thickness with a 400mm diameter black aiming mark fastened to the targets with double sided tape to allow easy removal of the aiming mark for measuring of the shot positions. The aiming mark used was a circle cut from an ICFRA 700 yard centre but the actual aiming mark used is irrelevant as long as the shooters can use it. Important was to duplicate the set up of the target so it was tested with identical layers of material on the front face as are used in competition. In addition to the aiming mark the test sheet was ruled into 6 squares of 0 mm using black marker pen to assist observers map shots. This ensured holes and monitor positions were never mismatched. Page

The Corflute sheet was fixed to the target using Velcro at positions around the edge. Centre lines on the target were transferred to the test sheets using a straight edge and red marker pen. The target identification number was written on the sheet and the top edge marked. During testing, temperature and humidity were recorded in the butts with a Kestrel 00 and reference marks were made on the Corflute to check its dimensional stability. The testing was undertaken from 800 metres using three different.8 rifles fitted with telescopic sights and fired from a rest. 800m (880 yards) was chosen to spread the shots across the entire test sheet. Carefully placing shots across the test sheet, not spilling any off the edges towards target sensors, yet with few shots close together is not easy. shots was chosen to ensure solid statistical results. A wind coach adjusted the sights to distribute the shots around the sheet. Most of the testing used NRAA issue.8 WHBC 55gn ammunition. Any other ammunition is noted in the results and representative muzzle velocities were recorded for each batch of ammunition using a LabRadar. On the mound the x-y coordinates of each shot were recorded independently by two people. Approximate shot position was relayed by radio to the butts where each observed shot was mapped on a sheet drawn up to mimic the test sheet. After each 0 shots the target was lowered and small numbered patches were placed over the shot holes. Thirty verifiable shots were fired on each test sheet. Any shots very close together in a sequence of ten were discounted and cut from the test with additional shots fired to make up the number. On the new targets only, shots that landed outside the test sheet were measured with a steel rule and included in the test data. The mound monitor data were recorded by two independent observers plus a video camera. This was a final double check in case of any dispute. Page 3

At the conclusion of the tests the Corflute sheets were stripped from the targets and the location of each hole measured on a purpose built machine using two electronic measuring scales to provide a simultaneous readout of the x and y coordinates of each numbered shot. The two scales were adjusted to be exactly orthogonal and the measuring head incorporated a crossed laser beam to allow precise positioning. The test sheets were adjusted on the machine so that the horizontal (red) centre line measured zero for y on both sides of the sheet, after which the head was moved to the centre of the sheet and both scales zeroed. Page 4

Each shot position was measured and recorded with the head being brought back to the centre for a check after every three to five shots. The resolution of the scales is 0.0mm but repeatability of hole centre measurements varied to a difference of mm. Both sets of measurements were entered into a spreadsheet for processing. The monitor data were entered from one set of records and then checked against the second set. The measured impact data were entered and then compared graphically against the monitor measurements after removing the acoustic centre error. Any significant variation triggered an examination of the mound video followed by a remeasure of the shot position. Results and Discussion At its most basic level the testing of an electronic target involves firing a number of shots into the target through a test sheet, measuring the actual shot positions and comparing them to the reported positions from the electronics. The resultant measured errors consist of :. A constant positioning error (acoustic centre vs geometric centre or centring error). A random error from the acoustic / electronic measuring system. The main focus of these tests is the random measuring error but to obtain this the centring error first has to be determined for each target and then subtracted from the measured errors. This is done by calculating the centre of the group (average shot position) for both the monitor and impact positions and then using the vector difference between them as the centring error. This is equivalent to sliding the test sheet until best fit is obtained with the reported shot positions. In general, the centring error was not large. centre error (horizontal) Varied from -.7 to +.7 mm centre error (vertical) Varied from - 6.6 to - 5. mm Page 5

The vertical error is considerably larger than the horizontal and the fact that all are negative indicates that the horizontal line used to locate the geometric centre should have been approximately 0mm lower on all the targets. This is a greatly exaggerated illustration of portion of an uncentred group. This error is constant and should not be ignored but it is automatically catered for by a shooter when he adjusts his sights in any shoot where each shot position is relayed to the shooter and the error is not excessive. Shot Position in Black, Monitor Position in Colour What remains after removing centring error is a representation of the variability of the target. Usually the errors are too small to see in this type of Graphic. The Random Error error is shown vividly for each shot in the following Graphic. This represents a very poorly maintained target. Page 6

This in contrast is a very good result from one of the used NQRA targets. Note that these errors show approximately real size and are almost trivial. The targets tested were: Three new targets : Three used targets: One badly degraded target: NQRA 9, NQRA 0, NQRA NQRA, NQRA, NQRA 3 TMRC It should be noted that the TMRC target was allowed to degrade past the normal refurbishment point to provide the required comparison. For the purposes of testing and comparison the targets will be considered as a measuring machine so the target error is the linear distance between the actual shot position and the reported shot position. Of the new targets NQRA 9 and were almost identical with average errors of.6mm and.7mm. The average for target NQRA 0 was.3mm but this increase was entirely caused by the mm error in shot No. 9. See below. The monitor record and the position measurements for this shot have been rechecked and there is no mistake. At more than five standard deviations away from the average, the probability of this error is approximately once in 0 million shots. It is far more likely to be caused by a glitch in the electronics. The used targets NQRA and 3 were indistinguishable from the new ones giving average errors of.6mm and.4mm respectively. Page 7

Target returned an average error of 3.9mm, two and a half times the average of the good targets. The majority of this increase is due to shots 4, 5, and 3. See Below. It is significant that these three shots are reasonably close to the target centre, the area that sustains the heaviest damage from shooting and suggests early stages of target degradation. Target TMRC had degraded well past the point where it should have been repaired and this is reflected in the errors which averaged 4.mm and were now larger and fairly uniformly distributed across the entire test area. Unfortunately at the time of writing no data was available for the number of shots that had been recorded on each of the targets although this is being sought, and it is hoped this information shows a direct correlation between shots fired and loss of accuracy. There is also going to be a strong influence from the type of shooting (Target Rifle vs F Class) and also the ranges at which the targets are used. Shorter ranges and F Class shooters concentrate more damage near the centre of the target and accelerate the degradation of accuracy. It is strongly recommended for the future that accurate records be kept of the number of shots fired on each target and that matches be organised so that F Class shooters are not concentrated on a small number of targets. Page 8

Full testing of the type done in this exercise is hard work, time consuming and expensive and would be impractical on a large number of targets. A system needs to be developed to allow assessment of the need for repair based on usage, type of shooting, and visual appearance of the target, plus a limited amount of testing. Based on the results presented it may be possible to asses degradation from a more limited test concentrated closer to the centre of the target and possibly undertaken as part of a normal club shoot. Because the tests were so detailed, and possibly unique, they represent a wealth of information which should be reported in full. The following two page concise report for each target gives particulars in excruciating detail. The table of errors represents CENTRED errors and is reported in various ways, each one best suited to a particular application. The (horizontal) and (vertical) errors are components of the total ACTUAL error. This is a convenient way to divide up errors to simplify measurement and analysis which shooters should relate to. Radial error is also tabulated because it relates directly to scoring. Most of the Radial errors on all targets except TMRC have a small negative value which indicates that the targets show most shots slightly closer to the centre rather than further away. Since on good targets this is a small error in all cases, and all targets show a similar trend, the effect on ranking order of shooters in a competition is benign. Badly degraded targets are another story. Some Standard Deviations are given in the Concise reports for completeness but you may gain more by examining the Graphics for each Target. SDs are metrics of target variability useful for predicting the probability of different errors which is a complex topic all by itself and is left out of this basic report. The only thing to note is that probability is usually predicted from a knowledge of BOTH MEAN and STANDARD DEVIATION. Because the and errors have already been corrected for centre error, by definition the mean of both the and the error is zero. Thus SDx and SDy are unique in that they stand alone as good predictors of errors within a Normal distribution. Which begs the question do all or most of the errors fit a Normal distribution? This report is intended to be objectively about what was measured so that will be left to another discussion. Page 9

NQRA SHOTS 8 WIN MV 900 f/s 55 grain projectiles Estimated Velocity at target 460 f/s Air Temperature 3.5 deg C. Humidity 65 % Test Sheet Stability < mm movement over 800 mm. at 880 ards SPAN 003.80 m m SPAN 995.63 m m CENTRE FITTED REPORT CENTRE SHIFT -0.9 m m CENTRE SHIFT -0.87 m m Show n Furthe r fr om Ce ntr e 0 Show n Clos e r to Ce ntr e RAW MEASUREMENTS No Im pact Im pact M onitor M onitor 58.3-45.0 58.8-403.5 9. -33.0 7.8-30.5 3 53.5 96.9 5.9 06. 4 7.6 60.4 70.5 70.8 5 8. 57.0 6.3 66.7 6 97. 483. 96. 49.3 7-97.0 59. -95.6 540. 8-455.8 388.6-453.0 398. 9-58. 45.6-57. 45. 0-44.8-4.0-43.9 -.6 05. -7.6 04.6-05.9-0. -73. -9.5-6.5 3-587.9-380.0-586. -368. 4-7. -40.9-69.6-9.9 5-44.3-359.0-43.3-348. 6-66.8-466.6-66. -455.3 7 6.0-387.3 5.5-375.7 8 97.4-43.0 97. -4 9 57. -35.9 55.4-3.3 0 87.3-7. 86.6-5.9-7.0 55.6-7.5 66.0-464.7 86. -46.0 95.4 3-369. -48.7-366.6-37. 4-0. 4.5-07.6 5.9 5 3.6 -.3.9 8.8 6-4. 43.7-39.8 53.8 7 -.8-69.6 - -58.8 8 69.6-57.9 68.4-46.6 9 45.9-66. 43.7-54.3 346.4 39.3 344.3 49.4 SHOT POSITIONS Grid in minutes and half minutes (880 yards) CENTRED ERRORS, 6, 5, 4, 3 indicate Score or how far shot is from the centre. BARS ARE REAL ERROR SIZE ACOUSTIC CENTRE SHIFT Depends on how accurately Aiming Marks are fixed to target. - 0.9 mm - 0.87 mm Page 0 No 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 -.4-0.8 -.3 -. -...6 0.9-0.8 0.4.5.4 0.8 0.4 - -0.5 -.9-0.9.5.4.4-0.9. 0.9 -.4 -.4 -.3 Rad Lin 0.6-0.5.7 -.. -.6 -.8.8-0.5 -..3 -. -.4.4 -.6 -.9.0 0. 0.0. -.3 -.8.9 -.4 -.6.7 0.5 0.0 0.8 0.8 -.. -0.8 0.8.0 -.8.8 0. -..4 0.0-0.5 0.8 0.4-0.5 0.6 -.0.0 0.5-0.6.7 -.5.5 0.4 -.0.0-0.5-0.5 0.6 -.5 -.9.9 0.6 -.5.5-0.4 -.3.4 0. -0.8.0 - -.4.4-0. -0.8 0.9 0.5 -.5.5. -.6.6-0.8 -.3.4

Target Errors have been broken into an (Horizontal) and (Vertical) component. Shooters instinctively think this way, we have measured the target this way, and it is a very convenient way to simplify calculations. AVERAGE mm (880 ards) SD component.50 mm component 0.9 mm Actual Direct (Lin).60 mm 0.007 minute 5 mm (880 ards) 0.006 minute 0.004 minute 0.003 minute SD values may be used to predict the probability of future errors which is left to another document. NOTE however, that maximum predicted errors in a number of shots is a multiple of the SD value. RED is expansion, GREEN contraction of reported shot positions. AVERAGE RADIAL SHIFT is.46 mm INWARDS Errors are usually too small to show with a very good target on a map of this type. See previous Graphic. Being a direct distance, this error is always positive. The SD if often greater than the Average. See Footnote. When it is impossible for an error distribution close to zero to spill into the negative region, the distribution is not a Normal Distribution. This is usually the case with Actual Direct Errors which are always positive. It now becomes a FOLDED NORMAL DISTRIBUTION. Calculation and use of SD now becomes complex. Many have wrongly applied the rules for a Normal Distribution to this case. Often the results only differ slightly but it really should be avoided. Applying this to make predictions is complex and best avoided. Page

NQRA 3 SHOTS 8 WIN MV 90 f/s 55 grain projectiles Estimated Velocity at target 470 f/s Air Temperature 3.5 deg C. Humidity 67 % Test Sheet Stability < mm movement over 800 mm. at 880 ards SPAN 89. m m SPAN 056.00 m m CENTRE FITTED REPORT CENTRE SHIFT.70 m m CENTRE SHIFT -9.9 m m Show n Furthe r from Ce ntre 8 Show n Clos e r to Ce ntre 4 RAW MEASUREMENTS No Impact Impact Monitor Monitor 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 3 3 39.6 9.5 34.3 34. 68.8-44.5-65. -85.5-539.5-8.8-77. 8.0 348. 35.7 49.5 93.9-63.7-64.0-355.3-43.9-399.4-33.7-348. -40.8-54. 9. 64.7 56. -79.9-03.6-54. -8.0-393.7-38.3-87.4-77. -37.9-570.5-0.8-0.6 -.5 384.6 98.9 36.0 69.6 43.8 335.9 434.9 40.5 485.5 479.9 33.7-99. 48.5-54.7 37. -9. 390.6-00.6-36.3-33. 05.0 35. 6.3 37.7 90. 3.4 3.8 65.7-44.4-65.8-84.8-540.0-8.5-77.3 79. 344.6 348.7 47.5 90.9-64.9-63.5-354. -43.0-399.3-3.7-347.5-4.4-67.5 8.8 6.7 54.0-79.9-04. -53.5-94.7-384.5 -.5-78. -68.5-36.4-56. -. 7.8-3.7 39. 07.0 44.3 76.5 4.0 34.8 443.6 40.5 49.8 485.5 339.9-90. 57. -45.6 7. -69.6 398. -90.8-6.4-4.5 3. 43.3 38.0 SHOT POSITIONS Grid in minutes and half minutes (880 yards) CENTRED ERRORS, 6, 5, 4, 3 indicate Score or how far shot is from the centre. BARS ARE REAL ERROR SIZE ACOUSTIC CENTRE SHIFT Depends on how accurately Aiming Marks are fixed to target..70 mm - 9.9 mm Page No -0. 3 -. 4-0.6 5 -.4 6.8 7.0 8.4 9. 0.0.5 -. 3 -.8 4 -.3 5-6 -.3 7 0.5 8. 9.8 0.6.8.7 3.4 4. 5 -.7 6.3 7-8 -0.4 9.7. 3.3 3 -.0 Rad -0.8 0.6 -.. - - -.3 0.6-0.5-0.5 -.5.0 -.3 0.5 -.5 -.0 -. -0.5 -.5-3. -.8 -.9 -.7 -. -3. -3.0 -.7 -. -3.0 -.9 -. -.7 -.9 -.9 -.7-3.3-4.3-5. -.7-3.7-0.9-0.6 -.3 -.7-0.8 -. 4. 3.7.7-3. -.4 -. -0. 0.0 0.0-0. -. -0.8 -.8 -. -.8 -.9.8.0 Lin 0.8..4.5.4.4.6.8.4 3..4.0 3.5. 3.0.8.0 3.5 5. 3.8.0 3.0.6 4. 7.3.7 0.4...9 6.

Target Errors have been broken into an (Horizontal) and (Vertical) component. Shooters instinctively think this way, we have measured the target this way, and it is a very convenient way to simplify calculations. AVERAGE mm (880 ards) SD component 3.4 mm component 5.56 mm Actual Direct (Lin) 3.89 mm 0.06 minute 5. mm (880 ards) 0.04 minute 0.04 minute 0.0 minute SD values may be used to predict the probability of future errors which is left to another document. NOTE however, that maximum predicted errors in a number of shots is a multiple of the SD value. RED is expansion, GREEN contraction of reported shot positions. AVERAGE RADIAL SHIFT is 0.95 mm INWARDS Errors are usually too small to show with a very good target on a map of this type. See previous Graphic. Being a direct distance, this error is always positive. The SD if often greater than the Average. See Footnote. When it is impossible for an error distribution close to zero to spill into the negative region, the distribution is not a Normal Distribution. This is usually the case with Actual Direct Errors which are always positive. It now becomes a FOLDED NORMAL DISTRIBUTION. Calculation and use of SD now becomes complex. Many have wrongly applied the rules for a Normal Distribution to this case. Often the results only differ slightly but it really should be avoided. Applying this to make predictions is complex and best avoided. Page 3

NQRA3. SHOTS at 880 ards 8 WIN MV 900 f/s 55 grain projectiles Estimated Velocity at target 460 f/s Air Temperature 3 deg C. Humidity 70 % Test Sheet Stability < mm movement over 800 mm. SPAN 009.60 m m SPAN 69.00 m m CENTRE FITTED REPORT CENTRE SHIFT -0.44 m m CENTRE SHIFT -6.66 m m Show n Furthe r from Centre Show n Clos e r to Ce ntre 8 RAW MEASUREMENTS No Impact Impact Monitor Monitor -67.3 58.6-66.0 64.0-38. 35.9-36.8 358. 3 348.8-37.8 347.6 -.7 4 6.0 604.5 6.6 6.4 5 9. 7.0 9.7.6 6 38.3 3.6 380.8 0.4 7 0. 434.5 9. 439.4 8 45.7 95.7 44.6 0. 9 8.8 457.9 8 463.0 0 79.0-8.6 77.9-75.5 4.4.6 4.6 9. -34-87.3-338.0-80.5 3-5.5-87.6-5. -80.8 4-77.0-8.8-75. -74. 5-35.6-05.5-35.0-98.7 6 86. -60.5 86. -5.3 7-84.9-397.8-84.0-390.6 8-4.9-3.8 -.5-4.8 9-38.5-564.5-37. -558. 0-486. -506. -484.5-498.8-3. -85.6 -. -77.9 67.9-393. 68. -385.8 3 377.8-33.0 377.7-35.8 4 64. 46.8 64.0 53.0 5 48.5.5 47.7 8.6 6 498. 0. 496.5 6.6 7 4.8-5. 6.3-44.7 8 9.5 4.8 0.4 3. 9-3.8 84.3 -. 90. -36.9-5. -33.9.0 SHOT POSITIONS Grid in minutes and half minutes (880 yards) CENTRED ERRORS, 6, 5, 4, 3 indicate Score or how far shot is from the centre. BARS ARE REAL ERROR SIZE ACOUSTIC CENTRE SHIFT Depends on how accurately Aiming Marks are fixed to target. - 0.44 mm - 6.66 mm Page 4 No 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0.9.0 -.6 0. 0.0 -.9 -.5 -.5 -.9 -.6 -.. -0..3 0. -0.6 0.5.9.0.3-0. -0.5-0.5 -. -..0 0.5..6 -.3 -.4 0.5 0. -.0 0. -.7-0. -.5 0.4-0. 0. 0..0 0..6 0.6-0.4 0.6. 0.6 0.5-0.4 0.4 - -0.4-0.8 0.4 Rad Lin -.6.6 -.6.7 -.7.7-0.4.0 -.9.9 -..3 -.4.5 -..4 -.6.6 -.. -.. 0. 0. -.6.7-0. 0. -.7.7-0.8 -.9.9 0..0 -.4.4 -.3.3-0.6 0.6 - -0.5 0.6 -..3 -.0. -.. -0.5 0.6 -.5.5 -.6.6

Target Errors have been broken into an (Horizontal) and (Vertical) component. Shooters instinctively think this way, we have measured the target this way, and it is a very convenient way to simplify calculations. AVERAGE mm (880 ards) SD component.9 mm component 9 mm Actual Direct (Lin).36 mm 0.006 minute 0.65 mm (880 ards) 0.006 minute 0.003 minute 0.003 minute SD values may be used to predict the probability of future errors which is left to another document. NOTE however, that maximum predicted errors in a number of shots is a multiple of the SD value. RED is expansion, GREEN contraction of reported shot positions. AVERAGE RADIAL SHIFT is.3 mm INWARDS Errors are usually too small to show with a very good target on a map of this type. See previous Graphic. Being a direct distance, this error is always positive. The SD if often greater than the Average. See Footnote. When it is impossible for an error distribution close to zero to spill into the negative region, the distribution is not a Normal Distribution. This is usually the case with Actual Direct Errors which are always positive. It now becomes a FOLDED NORMAL DISTRIBUTION. Calculation and use of SD now becomes complex. Many have wrongly applied the rules for a Normal Distribution to this case. Often the results only differ slightly but it really should be avoided. Applying this to make predictions is complex and best avoided. Page 5

NQRA9 3 SHOTS at 880 ar ds 8 WIN MV 960 f/s 55 grain projectiles Estimated Velocity at target 500 f/s Air Temperature 34.5 deg C. Humidity 60 % Test Sheet Stability < mm movement over 800 mm. SPAN 004.50 m m SPAN 34.00 m m CENTRE FITTED REPORT CENTRE SHIFT 0.53 m m CENTRE SHIFT -0.6 m m Show n Fur the r from Ce ntre 3 Show n Clos e r to Ce ntre 8 RAW MEASUREMENTS No Im pact Im pact Monitor Monitor 4.0 78.0 4. 793.9 06.9-59.3 04.6-48.6 3-59.3-76. -58.7-65.3 4-47.6 48.7-45.9 59.7 5-68.9 34. -67.9 33.5 6-3.5 369.9 -.8 378.9 7-33. 3.7-39.5 33.0 8 -.3 09. -.6 9.7 9-7.8 33. -8.3 43.9 0 58.6 9.8 57.3.4 46.7-98.0 44.9-86.6 34. -74. 339.7-6.5 3 587.0.5 586.3. 4 0.8 86.8 00. 97.3 5 378.9 08.4 376. 8. 6 34. 67.8 338.5 76.9 7 43.0 33.4 4 33. 8-4.3 9.4 -.8 39.3 9 46. 437.7 46.4 446.6 0 69.5 84. 69.5 93.5 8.4.8 79. 40.6-87.5 -.5-87.0-90.6 3 43.0-4.9 4.0-3. 4-5. 6-50.9 70.8 5-4.7-46.5-4.9-35. 6 46.8-378.6 46. -366.5 7 77.5-77.9 76.0-66.8 8 06.9-39.3 04.7-8. 9-64.5-533.0-63.3-5. -34.6-334.0-34.4-3.3 3 49.3-55.6 48.6-505.5 SHOT POSITIONS Grid in minutes and half minutes (880 yards) CENTRED ERRORS, 6, 5, 4, 3 indicate Score or how far shot is from the centre. BARS ARE REAL ERROR SIZE ACOUSTIC CENTRE SHIFT Depends on how accurately Aiming Marks are fixed to target. - 0.53 mm - 0.6 mm Page 6 No 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 3 -.7...6.3 3. 0. 0.0-0.8 -. -.0-0. -.0 -. -. -.8.0 0.5 -.7.0-0.4 0.9-0. -.0 -.6.7-0. Rad Lin.3.4.4 0. -.5.7 -.. 0.4 -.. -. -.8.0 -.6 -.8.0 -.4-3.4 3.4-0. - 0. 0.0 0. 0.0 0.5 0.8 0.8 -.5.5.0 -.. 0. -0. 0. -0. -.0. -0.8 -.4.4 -.5 -.6.6-0.9 -.9.0-0.8 -.7. -.7 -.7.8 -. -..3-0.8 -.9.9.3 -.7.7. -.. -0.5 -.0.0-0.8.5 -.5.5 0.5 -.. 0.5 -.4.7.3 -.0.. -.3.3-0.6 0.6 0.6

Target Errors have been broken into an (Horizontal) and (Vertical) component. Shooters instinctively think this way, we have measured the target this way, and it is a very convenient way to simplify calculations. AVERAGE mm (880 ards) SD component.39 mm component.0 mm Actual Direct (Lin).55 mm 0.007 minute 4 mm (880 ards) 0.005 minute 0.004 minute 0.003 minute SD values may be used to predict the probability of future errors which is left to another document. NOTE however, that maximum predicted errors in a number of shots is a multiple of the SD value. RED is expansion, GREEN contraction of reported shot positions. AVERAGE RADIAL SHIFT is.4 mm INWARDS Errors are usually too small to show with a very good target on a map of this type. See previous Graphic. Being a direct distance, this error is always positive. The SD if often greater than the Average. See Footnote. When it is impossible for an error distribution close to zero to spill into the negative region, the distribution is not a Normal Distribution. This is usually the case with Actual Direct Errors which are always positive. It now becomes a FOLDED NORMAL DISTRIBUTION. Calculation and use of SD now becomes complex. Many have wrongly applied the rules for a Normal Distribution to this case. Often the results only differ slightly but it really should be avoided. Applying this to make predictions is complex and best avoided. Page 7

NQRA0 3 SHOTS at 880 ards 8 WIN MV 900 f/s 55 grain projectiles Estimated Velocity at target 460 f/s Air Temperature 33 deg C. Humidity 6 % Test Sheet Stability < mm movement over 800 mm. SPAN 94.80 m m SPAN 94.00 m m CENTRE FITTED REPORT CENTRE SHIFT -.78 m m CENTRE SHIFT -8.96 m m Show n Furthe r from Ce ntre 4 Show n Clos e r to Ce ntre 7 RAW MEASUREMENTS No Im pact Im pact Monitor M onitor 7.66-6.73 0. -07. 74.63 7.7 76. 36.4 3 4 68 6. 693.7 4 5.35 55.37 6.5 64.4 5-8.5 364.55-78.9 373 6-36.8 9. -357.9 38. 7-0.96 76.68-97.5 84.8 8-0. 8.05-96.8 9.5 9-5.46-4.37-48.7-5. 0-77.73-34.4-73.5-33.9-38.64-63.44-34. -54. -49.85-33.39-47. -33.5 3-59. -66.4-55.9-56.4 4 0.4-53.4-503. 5 3.8-07.53 3.9-97.6 6 580-74 58.7-65. 7 9.36-05.99.6-95.8 8 86.9 7.48 88. 8.4 9-89.37-3. -85.6-4. 0-4.8-34.37-38.8-4.6 8.08 6.9 8. 6-90.44 45.9-87. 54.8 3 40 6.0 40.4 7.7 4 3.64 09.9 3.9 7.8 5 6.37 08.98 63.3 8.3 6 345.07 6.6 345. 5.6 7 407.9 79.68 407.3 88. 8 67.59 493.5 68.8 505. 9 07.09 7.77 94.7.7 466.46 59.08 466.7 68.4 3 557.5 0.5 559.8 0.4 SHOT POSITIONS Grid in minutes and half minutes (880 yards) CENTRED ERRORS, 6, 5, 4, 3 indicate Score or how far shot is from the centre. BARS ARE REAL ERROR SIZE ACOUSTIC CENTRE SHIFT Depends on how accurately Aiming Marks are fixed to target. -.78 mm - 8.96 mm Page 8 No 0.8-3 4-0.6 5.8 6 3. 7.7 8.5 9.0 0.5.8.0 3.5 4 0. 5-6 -0. 7-0.5 8 0. 9.0 0. -.8.5 3 -.4 4 -.5 5 0. 6 -.8 7 -.7 8-0.6 9-4. -.5 3 0.5 Rad Lin 0.6-0.8.0 - -0. 0.4 3.7 3.7 3.8 0. -0. 0.6-0.5 -.6.9 0.0-3. 3. -0.8 -.6.8 0.5 -.5.6 -.0.0 -.9.5 -.7.8 0.9 -..3 0.8 -.5.7 0.8-0.8 0.9.0 -.. -0. 0.0 0.. -.3.4 0.0 0.0 0. 0. -.0.0 0.8 -.5.5 0. -.8.8 0.6 -.5.6 -.4.6-0.4 -.6.6 0.4 0.4 0.4 0.5 -.8.8-0.5 -.8.8.6.5.7-5.0-5.9 0.4 -.4.6 0.9 0.6.

Target Errors have been broken into an (Horizontal) and (Vertical) component. Shooters instinctively think this way, we have measured the target this way, and it is a very convenient way to simplify calculations. AVERAGE mm (880 ards) SD component.97 mm component.88 mm Actual Direct (Lin).6 mm 0.009 minute 3.46 mm (880 ards) 0.03 minute 0.03minute 0.05 minute SD values may be used to predict the probability of future errors which is left to another document. NOTE however, that maximum predicted errors in a number of shots is a multiple of the SD value. RED is expansion, GREEN contraction of reported shot positions. AVERAGE RADIAL SHIFT is.5 mm INWARDS Errors are usually too small to show with a very good target on a map of this type. See previous Graphic. Being a direct distance, this error is always positive. The SD if often greater than the Average. See Footnote. When it is impossible for an error distribution close to zero to spill into the negative region, the distribution is not a Normal Distribution. This is usually the case with Actual Direct Errors which are always positive. It now becomes a FOLDED NORMAL DISTRIBUTION. Calculation and use of SD now becomes complex. Many have wrongly applied the rules for a Normal Distribution to this case. Often the results only differ slightly but it really should be avoided. Applying this to make predictions is complex and best avoided. Page 9

NQRA 3 SHOTS at 880 ards 8 WIN MV 940 f/s 55 grain projectiles Estimated Velocity at target 480 f/s Air Temperature 34 deg C. Humidity 60 % Test Sheet Stability < mm movement over 800 mm. SPAN 348.50 m m SPAN 357.00 m m CENTRE FITTED REPORT CENTRE SHIFT.00 m m CENTRE SHIFT -3.5 m m Show n Furthe r from Centre 7 Show n Close r to Centre 5 RAW MEASUREMENTS No Im pact Im pact M onitor M onitor 69.43 8 67.8 9.7 8.3 67.39 80.8 79.8 3 48.8-8.96 47.6-69.7 4 448.8-3.98 445. -0.9 5 3.74.39 37.7 4.9 6 595.5-9 594.9-06.9 7 33.7 40.93 3.5 53 8 38. 33.9 378.6 35.8 9 369.57 434.07 367 446.3 0-7.68 465.08-6.9 477.3-753 67-755.3 69-34.69 83.34-33.5 97. 3 9.3-93.37 8.4-79.9 4-5.78 94.74-5.5 08.5 5 6.4 6.8 5.7.7 6-98.03 6.43-97.9 39.4 7-80. 54.5-78.9 58.8 8-4.38-4.33-4. -7.8 9-383.94-9.39-383.4-4.7 0-3.45-97.6-3.5-83. -35.0-69.4-34.4-55 -97.49-454.09-98. -439.7 3-06.45-39.58-06.5-5. 4-5.5-44.69-53 -47.5 5 33.76-83.7 38.6-69.5 6 357.4-8. 353.8-04.3 7 508-685 508.5-675.4 8 8.43-77.4 80.5-63. 9 86.7-93.77 85. -80 55.94-58.78 53.8-45.3 3 3.4-3.3.6-09.6 3-39.4 09. -39.6.9 SHOT POSITIONS Grid in minutes and half minutes (880 yards) CENTRED ERRORS No, 6, 5, 4, 3 indicate Score or how far shot is from the centre. BARS ARE REAL ERROR SIZE ACOUSTIC CENTRE SHIFT Depends on how accurately Aiming Marks are fixed to target..0 mm - 3.5 mm Page 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 3 3-0.6-0.4-0. -.0 -.0 0.4-0. -.6 -.6.8 -.3..3...3.5.0.6 0.4.0-0.5 -. -.3.5-0.9-0.5 -. -0.8 0.6 -.5 -. - -0.4 -.0 -.4 -.5 -.6 -.3 -.3 5.5-0. 0. 0.4-0.6 0.8.0. 0.9 0.9 0.9 0.9 0.4-3.9 0.0 0. Rad -.6 -. 0. -.0 -.3 -.4 -.3 -.0 -.5 4.5 -.8 0.0 - -0. -. -0. -.6 -.6 -.3 -.8 -.0 -. -0.6 -. -. 4. -. -0.4 -.0-0.6-0.4 Lin.7..0.3.5.5.3.0. 5.6..3 0.5.3.3.6.9.3.8.0.3 0.8.3.4 4.. 0.6. 0.8

Target Errors have been broken into an (Horizontal) and (Vertical) component. Shooters instinctively think this way, we have measured the target this way, and it is a very convenient way to simplify calculations. AVERAGE mm (880 ards) SD component.33 mm component.47 mm Actual Direct (Lin).67 mm 0.006 minute.06 mm (880 ards) 0.006 minute 0.006 minute 0.005 minute SD values may be used to predict the probability of future errors which is left to another document. NOTE however, that maximum predicted errors in a number of shots is a multiple of the SD value. RED is expansion, GREEN contraction of reported shot positions. AVERAGE RADIAL SHIFT is 9 mm INWARDS Errors are usually too small to show with a very good target on a map of this type. See previous Graphic. Being a direct distance, this error is always positive. The SD if often greater than the Average. See Footnote. When it is impossible for an error distribution close to zero to spill into the negative region, the distribution is not a Normal Distribution. This is usually the case with Actual Direct Errors which are always positive. It now becomes a FOLDED NORMAL DISTRIBUTION. Calculation and use of SD now becomes complex. Many have wrongly applied the rules for a Normal Distribution to this case. Often the results only differ slightly but it really should be avoided. Applying this to make predictions is complex and best avoided. Page

TMRC 3 SHOTS at 880 ards SPAN 0.0 mm SPAN 00.60 mm CENTRE FITTED REPORT CENTRE SHIFT -.73 mm CENTRE SHIFT -5. mm Shown Further from Centre 9 Shown Closer to Centre 3 8 WIN MV 960 f/s 55 grain projectiles Estimated Velocity at target 500 f/s Air Temperature 3.5 deg C. Humidity 65 % Test Sheet Stability < mm movement over 800 mm. RAW MEASUREMENTS No Im pact Im pact M onitor M onitor -03. 80.5 -. 08.4-38.8 5.8-33.3 3.9 3-363.5-3.4-357.4 3.0 4-454. -7-449.8-53.8 5-7.9-98.4-37. -95.5 6-88.0-375.3-08.4-384.6 7-376. -378.5-400.9-39.3 8-04.4-399.0-00.8-38.8 9-44.8 -.6-55.3-0.8 0 9.7-50.0 49.8-6.4 3.8-54.5 38. -5.6 479.4-35.5 494.0-3.5 3 98.6 6.8.6 90.0 4 406.4 5.3 406.9.7 5 5.0 38.6 53.6 49. 6 38.8 3. 5.0 348.3 7 7.9 3. 86.4 39.5 8 8.4 4..5 55.6 9 -. 45.6-07.0 6.8 0-490. 89.3-483.8 05.9-50. 478. -508.6 506.9-30.9 85.7-34.6 0.8 3-97. 37.4-06.8 357.9 4 5.7 9.7 66.0 9.5 5-80.9 58. -90.5 88. 6-8.5-74.0-76.3-57.4 7-43.8 6.6-57. 49.8 8 66.9 64.9 8.7 93.0 9 6.5 8. 80.5 6. 4. -49.3 4.0-67.4 3. 386.3.3 400.5 3 399.6-56. 40-39. SHOT POSITIONS Grid in minutes and half minutes (880 yards) CENTRED ERRORS, 6, 5, 4, 3 indicate Score or how far shot is from the centre. BARS ARE REAL ERROR SIZE ACOUSTIC CENTRE SHIFT Depends on how accurately Aiming Marks are fixed to target. -.73 mm - 5. mm Page No 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 3 3 -.7 3.4.7 -. -3. -7.4 0.9-3. 7.4.7.9.3 -. -0. 0.5 0.8 0.4.5 3.7-0. 3.6 -.4.5 -.3 3.5-6.0. 6.3 -.9 -.5 -.6.8.0.3.8 -.3-4.4-8.0. -3.3-7.6 -. -. 3..3-4.6.0.3-0.6..5 3.7.0 5.4.7 4.9.4 8. 3.0 7.9-33. -.0.9 Rad 6.7 -.4-3.4 -.4 7. 3.7 39. -. 8.7 38.0 6.6 5.9 4.8 -. -.0 5.5 5.6-0.5 -. -3.3 6.9-3. 9.3 6.4 9.0-3.7 7.5 9.8 0. -.6 -. Lin 6.7.9 3.7.5 7. 33.6 39.. 8.7 38.9 6.9 6. 7.3.6 4.6 6.0 5.6.7 4.0 7.0 3.7 9.8 6.4 9.3 3.7 4. 7.8 4. 33.3.8.5

Target Errors have been broken into an (Horizontal) and (Vertical) component. Shooters instinctively think this way, we have measured the target this way, and it is a very convenient way to simplify calculations. AVERAGE mm (880 ards) SD component.7 mm component 3.79 mm Actual Direct (Lin) 4.3 mm 0.06 minute 0.47 mm (880 ards) 0.05 minute 0.06 minute 0.05 minute SD values may be used to predict the probability of future errors which is left to another document. NOTE however, that maximum predicted errors in a number of shots is a multiple of the SD value. RED is expansion, GREEN contraction of reported shot positions. AVERAGE RADIAL SHIFT is. mm OUTWARDS Errors are usually too small to show with a very good target on a map of this type. See previous Graphic. Being a direct distance, this error is always positive. The SD if often greater than the Average. See Footnote. When it is impossible for an error distribution close to zero to spill into the negative region, the distribution is not a Normal Distribution. This is usually the case with Actual Direct Errors which are always positive. It now becomes a FOLDED NORMAL DISTRIBUTION. Calculation and use of SD now becomes complex. Many have wrongly applied the rules for a Normal Distribution to this case. Often the results only differ slightly but it really should be avoided. Applying this to make predictions is complex and best avoided. Page 3