RG NDT INTERNATIONAL INC

Similar documents
RG NDT INTERNATIONAL INC. Drill Pipe and Tubing Inspection System

Noise Detector ND-1 Operating Manual

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

DIGITAL TIME CLOCK. used with the Meal-Time Control Panel. AGRI-TIME TM Control Instruction Page 1

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

The Phono Box SUMIKO Fifth Street Berkeley, CA sumikoaudio.com

AM-4 Audio Monitor. Videoquip Research Limited 595 Middlefield Road, Unit #4 Scarborough, Ontario, Canada. MIV 3S2

Metal Electrode Meter

Warner Photoscanner MCS-836/836-1/836-2

Sprite TL Quick Start Guide

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

Warranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.

Winch Adjustable Feed Level Tubes for the Adult Turkey Feeder Installation & Operator s Instruction Manual MF /99

Access Control Keypad for MK-DV, JB-DV

16-BIT LOAD CELL/DUAL STATUS INPUT

Warner Photoscanner MCS-500 Series LED Photoelectric Control

SCALE & WEIGHT DISPLAYS

Model No. ST60-S (-SRN, -SRK, -DRN, -DRK)

ADINSTRUMENTS. making science easier. MA3300 Audio Monitor. Owner s Guide

STUDIO Q User Guide. Radial Engineering Ltd Kebet Way, Port Coquitlam BC V3C 5M5 Tel: Fax:

AS Telecommunication Watch Dog. Version 2.70

U SER S G UIDE. TS2002A Fiber Optic Test Kit

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

Warner Photoscanner MCS-836/836-1/836-2

VK-P10SE WARRANTY REGISTRATION FORM

Chore-Tronics 2 Breeder Edition Override Box

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

Flarm Speaker. Installation Manual Version 1.00

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

Cryoelectronics. MS-FLL User s Manual. Mr. SQUID Flux-Locked Loop. STAR Cryoelectronics 25 Bisbee Court, Suite A Santa Fe, NM U. S. A.

Installation And Programming Guide

LIGHT COPILOT II. elationlighting.com Internet:

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

For use with QED and hardwired control panels ONLY!

34MD Series. Motor/Driver Combination. User s Guide E. Landon Drive Anaheim, CA

Instruction Manual. Wireless Transmitters (Digital) RVS-550W. Reverse With Confidence 1

LUDLUM MODEL ALPHA-BETA SAMPLE COUNTER SERIAL NUMBER PR AND SUCCEEDING SERIAL NUMBERS. February 2016

HDTV Supply Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written

Model No. ST60-SPS (-SRN, -SRK, -DRN, -DRK)

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

M1020 Programmable Limit Switch (PLS)

User Manual. VGA to Component or Component to VGA Converter Scaler AT-VGA300CV

minihomer TM User s Guide

HTP1502W1 Remote Controlled Multicolor Lighting System

Installation and Tuning Manual DAC 7000 DAC 2X

TAC1 Telephone Entry System

LavryBlack Series Model AD10 Analog to Digital Converter

instruction manual model 307 horizontal video caliper

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

INSTRUCTION MANUAL. MODEL Downconverter

Introduction Congratulations and thank you for purchasing W Box Technologies 0E-HDMISPL2.

INSTRUCTION MANUAL DAFM2

UC1000 Universal Controller

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

PC/HDTV 2-Way Converter

HS-509 VIBRATION TRIP MODULE

Atlona 8x8 Component Matrix Switcher with Stereo Audio AT-COMP-88M

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

Product Identification

MWT-FM. Operation Manual. FM Single Channel Transmitter. man_mwtfm.

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

Digital Lighting Systems, Inc.

PH60B Phono Stage. User Guide

TC3005(LED/ELED/LASER) User's Manual

Instruction Manual Model # Block Upconverter

User Manual. AtlonA. 1 x 10 VGA with Stereo Audio Distribution Amplifier over CAT5/6 compatible with AT-VGA300RL AT-VGA10SS

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model BlockUpconverter

Viztrac AM200 User s Guide. Page 1 of 12

MAN FDAIP-CVH VER HDSDI

ES-450J2 Universal 2 Channel Jog/Shuttle Remote

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

WID-DL74 WID-DL74 BLP WID. Designed for. Installation guide for workitdesk interactive table for. BrightLink Pro

Digital Lighting Systems. DIGTAN4-PRO Converts 4 PROTOCOL channels to 4x 0.5 V to 10 VDC Analog

Owner s Manual. UHD 4Kx2K HDMI Splitters. Models: B UHD, B UHD, B UHD-WM, B UHD

Satellite Receiver. Chapter REMOTE CONTROL USING THE MENUS USING TEXT FIELDS. About Your Satellite Receiver. What you ll find in this chapter:

Operating Instructions

DMP3. Users Manuual. Ver. # DMP

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

Installation And Programming Guide

Owner s Manual. VGA + Audio to HDMI Adapter/Scaler. Model: P HDSC2

Owner's Manual DIGITAL TO ANALOG BROADCAST CONVERTER WITH REMOTE CONTROL. Model: CVD508 PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

STEREO OR MONO CONTINUITY TM POWER AMP

Table of Contents. Read This First.2. Introduction by Jim Fosgate...3. Unpacking..4. Tubes and Tube shield Installation 5. Product Placement...

ARS x4 MATRIX SWITCHER Instruction Manual

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Sphinx II. Owner s Manual. Tube Hybrid Integrated Power Amplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 08/01/16

MaxView Cinema Kit Quick Install Guide

Room Control. Installation & Operations Guide. cambridgesound.com

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

MP-204D Digital/Analog Stereo Monitor Panel

OPERATING INSTRUCTIONS. Single Function Timers Model No. 740-T, 740-TJ & 740-TSeries ELECTRICAL TABLE OF CONTENTS

Transcription:

RG NDT INTERNATIONAL INC User Manual 165 Oates Road Houston, Texas 77013 Phone: 713-673-5928 Fax: 713-673-5957

GENERAL OVERVIEW Features two (2) inline inspection stations for the detection of: 1. Transverse and three dimensional flaws, and 2. Wall or metal loss. The flaw detecting station employs air actuated shoes that contact the product surface. The shoes contain small coils to detect flux leakage caused by flaws. The detected signals are amplified and processed via a Z2120 single board computer. The largest indication at any given time is scaled and transferred to a laptop computer that serves as a display and recorder. A second means of recording is provided through the use of a four (4)- channel thermal chart recorder. Odd channels are displayed on one trace (trace Number 3), while even channels are displayed on a second trace (trace Number 4). The electronics also feature preamplifiers and peak-detectors to assure that the computer recognizes the significance of every indication. The wall monitoring station employs an encircling array of Hall devices that monitor the product traveling through the station. These non-contact transducers detect metal loss or gain. Changes in metal thickness are detected and processed via a second Z2120 single board computer. When tubing is inspected the computer provides two (2) outputs, the first output indicates the average wall thickness (trace Number 1) and the second output indicates the smallest wall (trace Number 2). When sucker rod is inspected, one output indicates total metal loss and the second its smallest diameter. Tubing metal hardness alter magnetic wall thickness monitoring. These two (2) computers, flaw detection preamplifiers, flaw peak detectors, an interface card for magnetic wall, electronic power supply, and relays to control magnetizing point are housed in the electronic desk. The controls allow the operator to set sensitivity and linearity. Alarms are both audible and visual. Tracking numbers can be placed on the chart through the keyboard and streamlined to memory. Four (4) photo eyes control the pinch rolls, the activation of the flaw shoes, and the magnetization point. 2

THE FLAW DETECTING AND PROCESSING SYSTEM The Z2120 has the following seven (7) control keys: 1. A right arrow key to move the a cursor to the right, 2. A left arrow key to move the cursor to the left, 3. An Up arrow key to move the cursor up, 4. A down arrow key to move the cursor down, 5. A + key to increase the gain, 6. A - key to decrease the gain, 7. An enter key to lock the desired setting. In addition: 1. A ten (10) turn potentiometer labeled REJECT allows linear rejection of small noise indications from the thermal recorder and the laptop computer screen, 2. A switch labeled ALARM enables the audible alarm, 3. A switch labeled FAST enables fast operation while disabling the display screen. The display (122x32 LCD) screen. is both graphical and alpha numeric. Vertical bars labeled 1 through 8 indicate the flaw signal levels. A vertical bar labeled R, with a dashed line on top indicates the REJECT threshold. The right hand of the display contains the alpha numeric information. The first line indicates the program version inspect 3. The second line allows moving from the RUN mode to the reset (RST) mode, to the calibrate (CAL) mode. This is accomplished when the RUN/FAST switch is in the RUN mode and the cursor is addressed through the UP, DOWN, RIGHT, and LEFT keys. The third item on the right hand indicates the overall gain of the system as N=1.00. This overall gain can be raised or lowered with the + and - keys. A RETURN key is used to lock the new setting. The bottom line of the alpha numeric display allows monitoring of individual channel gain and reject threshold. The RIGHT and LEFT keys allow moving from one channel to the other. The respective gain is displayed and can be increased or decreased with the + and - keys only when the channel is selected. A RETURN key should be used to lock any setting. The Questionable and REJECT threshold level settings are to the right of channel 8. When a small diameter tube or a sucker rod is inspected four (4) shoes are engaged with the product after it passes through the second photo eye. When a larger diameter tube is inspected eight (8) shoes are engaged with the product after it passes through this photo eye. The photo eye detects the incoming product and activates a timer, at the end of the timing interval the air head 3

shoes are lowered. Activation of the shoes can be disabled, enabled or executed automatically by a manual switch labeled AIRHEAD. In the AUTO position the airhead is activated a short time after the pipe passes through photo eye Number 2. In the OPEN position the shoes will not activate, and in the close position the shoes are forced down. Signals from the coils in the shoes are cabled to preamplifiers via a 17 pin plug, processed via a peak detector and scaled by the computer. The operator can select any specific channel and alter its sensitivity with the + or - keys. A RETURN assures that the selected sensitivity is maintained. The sensitivity of a channel is shown as G1=010, for example. This label can be read as Gain of channel 1 is set to 10%. A display indication of G3=015 shows that the Gain of channel 3 is set to 15%. Address the channel, and increase or decrease the sensitivity with the + and - keys, locking the sensitivity with the RETURN key. The N= 1.0 allows raising or lowering the sensitivity of all channels. Two alarm thresholds are provided. One is the yellow Y= threshold and the second is the red R= threshold. The threshold levels are shown on the display. The threshold level are changed with the + and - keys and should be locked with the return key. After the sensitivity, and two (2) alarm thresholds are set the screed can be switched to the FAST mode to speed up processing of data. Switches are provided to disable/enable individual channels and LEDs are featured to indicate when a signal exceeds the red threshold values. The led is timed to flash for 2 seconds on each detected flaw. When all the channels are adjusted a reject potentiometer allows rejection of noise (unwanted signals) from the thermal recorder and the laptop computer. In the CAL mode the reset sequence of individual channels is disrupted and the computer will display the largest indication for each channel until the curser is moved to the RUN position. A RST cursor position followed by the ENTER key resets all gain to the default settings of the computer (10% of each channel gain and the overall gain N to l.00). This is indicated, for example, as G1=010, N=1.00. The gain can be changed at 1% increments from 1% to 99% (G1=001 to G1=099). Once the desired gain setting is reached it should be secured with the RETURN key and the computer will remember the settings (until in a RESET position followed by the RETURN button is activated). In a four (4) shoes arrangement G1, G2, G3, G4 are used. In an eight (8) shoe arrangement G1, G2, G3, G4, G5, G6, G7, G8 are used. When a four (4) shoe system is employed the operator is to de-activate the unused channel with the individual switches. The Y (questionable) and R (bad) threshold are set via the keyboard by addressing the Y (to the right of channel 8) and selecting the Yellow alarm level with the + and - buttons, securing it with the RETUN key. 4

The R (reject) alarm level is to the right of the Y alarm level. Only when an indication exceeds the R alarm level does the respective LED and sound alarm activate. The N= allows overall gain adjustments by increasing the sensitivity with the + button or decreasing the sensitivity with the - button. The RETURN key is to be activated to secure the reading. An audible alarm is activated when the switch is the ALARM position and a flaw exceeds the reject threshold. Use the RUN or (preferably) the FAST mode while inspecting. The ALARM light are timed to come on for two seconds for each flaw that causes a signal that exceeds the R threshold. A toggle switch enables/disables the audible ALARM. A REJECT potentiometer allows removal of small stray signals. Make sure that the desired signals are at least twice the size of the rejected noise. Calibration Suggestion: Set the Mag current to 1 amp for every.100 of wall thickness. (2 amp for wall of 0.200, 3 amp for wall of 0.300 etc.). Increase the voltage of the power supply and reduce the current to this level. Pass the standard tubing at the specified speed of (45 to 60 fpm or13 to 18 mps) in the CAL mode. Adjust individual channel sensitivity to indicate bars that are about 90% of the screen. Set the questionable level to 50% of screen and the reject level to 70% of the screen. Move to the RUN mode and verify calibration. Switch to the FAST position. 5

THE WALL DETECTING AND PROCESSING SYSTEM The Z2120 has the following seven (7) control keys: 1. A right arrow key to move the a cursor to the right, 2. A left arrow key to move the cursor to the left, 3. An Up arrow key to move the cursor up, 4. A down arrow key to move the cursor down, 5. A + key to increase the gain, 6. A - key to decrease the gain, 7. An enter key to lock the desired setting. In addition: 1. A ten (10) turn potentiometer labeled BIAS allows bringing various thicknesses to the operating range of the computer, 2. A switch labeled ALARM enables the audible alarm, 3. A switch labeled FAST enables fast operation while disabling the display screen. When a small diameter tube or a sucker rod is inspected four (4) non- contact arrays are engaged positioned around the product in a constant magnetic field. Signals from the array of Hall elements are preamplifiers at the inspection station and cabled to be processed and scaled by the computer. The operator can select any specific channel and adjust the wall readings when a standard product is within the magnetic field. The CAL_HI position allows for such individual adjustments. The CAL_LO position allows for calibration using a reduced body wall section. Addressing the desired channel with the cursor and altering the reading to a number related to the thickness with the + or the - buttons will serve as a calibration procedure. A return key activation secures the selected sensitivity. The BIAS potentiometer allows the adjustment needed to bring various different thicknesses to the operating range of the computer. Changes in wall thickness can be monitored on a small 122x32 LCD screen when in the RUN mode. In the FAST mode the display screen is deactivated to allow for faster processing. The graphic display part of the screen is deactivated also in the CAL_HI and CAL_LO modes. An ALARM level is selected at the R= position. Inputs below this alarm level will trigger the audible and visual alarms for the duration of the occurrence. Switches are provided to disable/enable individual channels. The scale of the screen is automatically adjusted to 120% of the NOMINAL pipe thickness that was selected at the N= position. The default value of the R= is calculated to be 80% of the 6

nominal wall thickness. The R= default level can be altered with the + and - buttons. Note to secure the number with the RETURN key. One toggle switch controls the audible ALARM, and another toggle switch allows selection of the FAST mode (when the computer is completely engaged in the inspection process and the screen is not updated) or the RUN mode (when the graphic display is activated). The keys of the Z2120 computer are similar to the keys of the previously described Flaw Detector system. 7

DESK CONTROLS Two (2) Elgar/Sorenson power supplies furnish the current for the two magnetizing coils. It is recommended to operate them in the constant current mode. The voltage controlled potentiometer should be higher so that when the coil is hot the current does not change. A Minarik regenerating power supply furnishes the power to the product translating motors. The conveyor speed is adjusted with an on board potentiometer. A bi-directional switch allows reversal of product direction. The pipe is translated with four (4) motors. Two (2) are mounted on the entry and exit conveyers, and two (2) are mounted on the pinch-rolls. As the Flaw detecting shoes and the pinch rolls are not protected by the photocells in the reverse direction, make sure that the shoes are disengaged when the pipe/ sucker rod are reversed. The Exit conveyor is furnished with an air activated kick-out. The direction of the exiting product and the kick-out timing are operator controlled. The Sub desk contains two (2) sets of breakers. A dual breaker to limit the 220 VAC current to magnetizing supplies and a single breaker to limit the 110VAC current to conveyor supply. The Desk contains one (1) breaker limit the current to the electronics. 8

DIRECTION OF MAG CURRENT The proper direction of magnetic current is so that the initial readings on the display are decreased in amplitude with an increase in magnetic current. If the readings are increasing with an increase in magnetic current, turn off magnetic supply and reverse the magnetic current direction by switching the two leads from supply to the coil. Turn on magnetic supply and verify that the readings are decreasing with an increase in magnetic current. 9

Computer programs are sole property of RG NDT Int., inc. Houston, Texas. Any change or abuse voids all warrant. RG NDT INT. INC. warrant that the InSpect 3 will be free from defects in material and workmanship and that it will perform substantially in accordance with this written document for a period of ONE YEAR from the day of purchase. The warranty for the inspection heads, transducers and cables is limited to 60 DAYS from day of purchase. RG NDT will repair or replace, at its sole option and free of charge to the original customer, any equipment that is found to be defective provided that the customer returns the defective instrument or system to RG NDT with transportation prepaid. This warranty is void if the defects, based on the sole judgment of IST, resulted from misapplication, accident, abuse, negligence, tampering or modification of the product by persons not authorized by RG NDT. Within the ONE YEAR warranty period RG NDT will repair returned equipment that was damaged accidentally or by misapplication, at cost plus 30%. Equipment damaged due to abuse, tampering, or modification to the electronics will not be repaired and will be shipped back to customer. In no event will RG NDT be liable for any indirect, incidental or consequential damage or loss of revenue arising from the use or failure of this product. Purchaser agrees to indemnify, hold harmless and defend, including but not limited to attorney s fees, court costs travel cost, RG NDT from any claims or lawsuits that arise from the use of this product. RG NDT reserves the right to make any changes in design or construction without incurring any obligation to retrofit units previously delivered. This Equipment is NOT certified to be used in hazardous areas. 10