arxiv: v1 [physics.ins-det] 15 Jan 2019

Similar documents
Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals

Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results

Silicon PhotoMultiplier Kits

CAEN Tools for Discovery

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment

arxiv:hep-ex/ v1 27 Nov 2003

Updates on the Central TOF System for the CLAS12 detector

An extreme high resolution Timing Counter for the MEG Upgrade

PoS(PhotoDet 2012)018

Production and Development status of MPPC

READOUT ELECTRONICS FOR TPC DETECTOR IN THE MPD/NICA PROJECT

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

An extreme high resolution Timing Counter for the MEG experiment Upgrade

The CALICE test beam programme

Test beam data analysis for the CMS CASTOR calorimeter at the LHC

A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe HADES CBM

Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade

Commissioning and Performance of the ATLAS Transition Radiation Tracker with High Energy Collisions at LHC

Tests of Timing Properties of Silicon Photomultipliers

TitleLarge strip RPCs for the LEPS2 TOF. Author(s) Chu, M.-L.; Chang, W.-C.; Chen, J.- Equipment (2014), 766:

Institute of Electrical and Electronics Engineers (IEEE)

arxiv: v1 [physics.ins-det] 1 Nov 2015

Realization and Test of the Engineering Prototype of the CALICE Tile Hadron Calorimeter

Status of the CUORE Electronics and the LHCb RICH Upgrade photodetector chain

First LHC Beams in ATLAS. Peter Krieger University of Toronto On behalf of the ATLAS Collaboration

Beam test of the QMB6 calibration board and HBU0 prototype

TORCH a large-area detector for high resolution time-of-flight

Report from the 2015 AHCAL beam test at the SPS. Katja Krüger CALICE Collaboration Meeting MPP Munich 10 September 2015

Compact Muon Solenoid Detector (CMS) & The Token Bit Manager (TBM) Alex Armstrong & Wyatt Behn Mentor: Dr. Andrew Ivanov

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

The hybrid photon detectors for the LHCb-RICH counters

THE ATLAS Inner Detector [2] is designed for precision

... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL*

THE TIMING COUNTER OF THE MEG EXPERIMENT: DESIGN AND COMMISSIONING (OR HOW TO BUILD YOUR OWN HIGH TIMING RESOLUTION DETECTOR )

Sensors for precision timing HEP

Development of Ultra-High-Density (UHD) Silicon Photomultipliers with improved Detection Efficiency

A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications

The ATLAS Pixel Detector

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

A Large-Area Timing RPC

Development of an Abort Gap Monitor for High-Energy Proton Rings *

Software Tools for the Analysis of the Photocathode Response of Photomultiplier Vacuum Tubes

Status of GEM-based Digital Hadron Calorimetry

Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds

Sensors for the CMS High Granularity Calorimeter

Photo Multipliers Tubes characterization for WA105 experiment. Chiara Lastoria TAE Benasque 07/09/2016

STUDY OF ANODE SELF-TRIGGER ABILITY OF ME1/1 CMS ENDCAP CATHODE STRIP CHAMBER

The CMS Detector Status and Prospects

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Systematic study of innovative hygroscopic and non-hygroscopic crystals with SiPM array readout

Status of the Timing Detector Plastic+SiPM Readout Option

The Silicon Pixel Detector (SPD) for the ALICE Experiment

Drift Tubes as Muon Detectors for ILC

li, o p a f th ed lv o v ti, N sca reb g s In tio, F, Z stitu e tests o e O v o d a eters sin u i P r th e d est sezio tefa ectro lity stem l su

Status of CMS and preparations for first physics

DAQ Systems in Hall A

Liquid Xenon Scintillation Detector with UV-SiPM Readout for MEG Upgrade

3-D position sensitive CdZnTe gamma-ray spectrometers

Solid State Photon-Counters

The ATLAS Tile Calorimeter, its performance with pp collisions and its upgrades for high luminosity LHC

Diamond detectors in the CMS BCM1F

Design of a Gaussian Filter for the J-PARC E-14 Collaboration

The Scintillating Fibre Tracker for the LHCb Upgrade. DESY Joint Instrumentation Seminar

SPE analysis of high efficiency PMTs for the DEAP-3600 dark matter detector

The Time-of-Flight Detector for the ALICE experiment

A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read-out

Lifetime of MCP-PMTs

A new Scintillating Fibre Tracker for LHCb experiment

Current status of Hamamatsu Si detectors mainly for High Energy Physics Experiments

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

HAPD and Electronics Updates

Atlas Pixel Replacement/Upgrade. Measurements on 3D sensors

Commissioning and Initial Performance of the Belle II itop PID Subdetector

SciFi A Large Scintillating Fibre Tracker for LHCb

R&D on high performance RPC for the ATLAS Phase-II upgrade

Calibration of photomultiplier tubes for the large-angle beamstrahlung detector at CESR

Performance and aging of OPERA bakelite RPCs. A. Bertolin, R. Brugnera, F. Dal Corso, S. Dusini, A. Garfagnini, L. Stanco

Progress Update FDC Prototype Test Stand Development Upcoming Work

Comparison Between DRS4 Chip-Based Boards and ADCs for a Flexible PET Electronics

Single Photoelectron timing resolution of SiPM

Investigation of time-of-flight PET detectors with depth encoding

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

Imaging TOP (itop), Cosmic Ray Test Stand & PID Readout Update

Citation X-Ray Spectrometry (2011), 40(6): 4. Nakaye, Y. and Kawai, J. (2011), ED

Synchronization of the CMS Cathode Strip Chambers

arxiv: v1 [physics.ins-det] 2 Dec 2008

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 5, OCTOBER

This work was supported by FINEP (Research and Projects Financing) under contract

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

DEPFET Active Pixel Sensors for the ILC

First evaluation of the prototype 19-modules camera for the Large Size Telescope of the CTA

High ResolutionCross Strip Anodes for Photon Counting detectors

Proposed STAR Time of Flight Readout Electronics and DAQ

A pixel chip for tracking in ALICE and particle identification in LHCb

LHC Beam Instrumentation Further Discussion

Study of the performances of the ALICE muon spectrometer

RF Testing of A Single FPIX1 for BTeV

Removing the Pattern Noise from all STIS Side-2 CCD data

Data Acquisition System for Segmented Reactor Antineutrino Detector

Transcription:

Time resolution studies for scintillating plastics coupled to silicon photo-multipliers arxiv:1901.04964v1 [physics.ins-det] 15 Jan 2019 Mauricio Alvarado 1, Alejandro Ayala 1,2, Marco Alberto Ayala-Torres 3, Wolfgang Bietenholz 1, Isabel Dominguez 4, Marcos Fontaine 3, P. González-Zamora 5, Luis Manuel Montaño 3, E. Moreno Barbosa 6, Miguel Enrique Patiño Salazar 1, V. Z. Reyna Ortiz 6, M. Rodríguez Cahuantzi 6, G. Tejeda Muñoz 6, Maria Elena Tejeda-Yeomans 7, Luis Valenzuela-Cázares 8, C. H. Zepeda Fernández 1,6 1 Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Apartado Postal 70-543, CdMx 04510, Mexico 2 Centre for Theoretical and Mathematical Physics, and Department of Physics, University of Cape Town, Rondebosch 7700, South Africa 3 Centro de Investigación y Estudios Avanzados del IPN, Apartado Postal 14-740, CdMx 07000, Mexico 4 Facultad de Ciencias Físico-Matemáticas, Universidad Autónoma de Sinaloa, Av. de las Américas y Blvd. Universitarios, Cd. Universitaria, C.P. 80000, Culiacán, Sinaloa, Mexico 5 Departamento de Ingeniería Industrial, Universidad de Sonora, Avenida Universidad S/N, Edificio 5K, Planta Baja, Colonia Centro, 83000 Hermosillo, Sonora, Mexico 6 Facultad de Ciencias Físico Matemáticas, Benemérita Universidad Autónoma de Puebla, Av. San Claudio y 18 Sur, Edif. EMA3-231, Ciudad Universitaria 72570, Puebla, Mexico 7 Facultad de Ciencias-CUICBAS, Universidad de Colima, Bernal Díaz del Castillo No. 340, Colonia Villas San Sebastián, 28045 Colima, Mexico 8 Departamento de Investigación en Física, Universidad de Sonora, Boulevard Luis Encinas J. y Rosales, Colonia Centro, Hermosillo, Sonora 83000, Mexico We present results for time resolution studies performed on three different scintillating plastics and two silicon photo-multipliers. These studies are intended to determine whether scintillating plastic/silicon photo-multiplier systems can be employed to provide a fast trigger signal for NICA s Multi Purpose Detector (MPD). Our results show that such a system made of cells with transverse dimensions of order of a few cm, coupled to silicon photo-multipliers, provides a time resolution of about 50 ps, which can be even further improved to attain the MPD trigger requirements of 20 ps. Keywords: Time resolution, scintillating detectors, Silicon photo-multipliers. I. INTRODUCTION Scintillating detectors are used for a wide range of purposes, from medical imaging and radiation security to nuclear and high-energy physics. Scintillating detectors are commonly coupled to photo-multiplier tubes (PMTs) that can serve as the readout part of the detectors. However, in recent times there has been great interest in the use of silicon photo-multipliers (SiPMs) as an alternative to PMTs, due to their high photon detection efficiency and good time resolution. SiPMs are low cost devices which have the advantage of being compact and magnetic field resistant, see e.g. Ref. [1]. Detectors made of scintillating material with SiPMs readout are also promising to obtain a competitive time resolution [2]. These systems are used in high-energy experiments mainly to detect charged particles. The common choice for the scintillation material is either a crystal or a plastic. These materials produce light when subatomic charged particles traverse them. In general, the emitted light has a frequency in the high end of the visible region. The produced photons are collected by the SiPMs that in turn generate electrical signals by means of photoelectric processes. These systems have a distinctive Corresponding author, email:hzepeda@fis.cinvestav.mx time resolution that makes them ideal to be used as part of wake-up triggers in high energy collider experiments. One such experiment, which is currently under construction, is the Multi Purpose Detector (MPD) of the Nuclotron-based Ion Collider facility (NICA) at the Joint Institute for Nuclear Research (JINR) [3]. The main goal of the MPD is to study the properties of strongly interacting matter at high temperature and high baryon density [4] and in particular to locate the possible critical end point in the QCD phase diagram [5]. For these purposes, NICA will provide a wide range of hadron beams, including heavy and light nuclei as well as protons with center of mass energies between 4 and 11 GeV for Au+Au collisions and up to 27 GeV for p+p collisions. The design of the MPD includes, as its detector systems, the Inner Tracker (IT), the Time Projection Chamber (TPC), the Zero Degree Calorimeter (ZDC), the Electromagnetic Calorimeter (ECal), the Time of Flight (TOF) and the Fast Forward Detector (FFD) [6, 7]. A magnetic field of 0.5 T will be provided by a Magnetic Solenoid. The barrel region is designed to cover a pseudorapidity range η 1.2 with the end caps and the FFD extending the coverage to 1.2 η 2 and 3 η 3.9, respectively. The TPC, ECal, TOF, ZDC, FFD and the Magnet are the detector systems planned to be included in the first run, which is scheduled for 2020. The IT will be added in a second run. Two Forward Spectrometers (FS-A and FS-B) based on toroidal magnets,

2 II. EXPERIMENTAL SET UP Figure 1. Telescope arrangement. The figure shows the representation of the test scintillating plastic and reference scintillating plastic (BC408). (a) side view. (b) front view. may be installed for the third run and they are planned to cover the region 2 η 4. Given the absence of the IT for the first run, the FFD is supposed to provide the trigger for the TOF. Simulations show that for the large multiplicity environment in Au+Au collisions, the FFD provides a good time resolution to serve as such a trigger. This may not be the case, however, for the lower multiplicities produced in collisions of lighter systems [8]. The need to find an adequate trigger for the TOF has prompted research with the purpose to design a fast detector component which may also serve as a redundant element and perhaps to extend the rapidity coverage of the originally planned MPD elements. A possibility for such a detector element has been put forward in Ref. [9]. This is a beam-beam counter consisting of two discs made of hexagonal scintillating plastic tiles. Each disc is planned to be located 2 m away on either side of the interaction point along the beam pipe. Details of its design and capabilities can be found in Ref. [9], which also shows the time resolution for one kind of plastic tile coupled to either a PMT or a SiPM, obtained in a pion beam test made at the T10 facility at CERN. In order to complement these time resolution studies, here we present the results of laboratory tests using a telescope array triggered both by cosmic rays and charged particles coming from radiation sources, to measure the time resolution of several kinds of plastic tiles coupled to different SiPMs. We show that a time resolution similar to the one obtained in the pion beam test is achieved. This work is organized as follows: In Sec. II we describe the experimental set up. In Sec. III we outline the way we carried out the data acquisition and present the analysis of the results. In Sec. IV we discuss these results and present our conclusions. The study was performed using tiles made of two different scintillating commercial plastics: BC404 R Bicron, BC408 R Bicron. In addition, we also tested one scintillating plastic developed at Facultad de Ciencias Físico- Matemáticas, Benemérita Universidad Autónoma de Puebla (BUAP), México [10] (BUAP-SP). We tested the performance of two different SiPMs: (C-60035-4P-EVB) R SensL [11] and (S10985-050C) R Hamamatsu [12], which were coupled to the scintillating plastics to compare their light acquisition and time response performance. We placed these SiPMs at different locations over each plastic surface in order to identify the optimal geometrical configuration for the signal acquisition. We also implemented some improvements in the data readout by testing different configurations for the electronics that send the light sensor signals to the acquisition set up. The improvements were meant to obtain a low noise fast signal (reaching a peak time in less than 30 ns) using common electronic devices and materials. The BC408 and BC404 where taken as square tiles with dimensions 10 10 2 cm 3, whereas for the BUAP-SP we use a hexagon tile 5.6 cm high and 1.5 cm thick. To test the performance of the three scintillating plastic tiles, we used a telescope arrangement consisting of two BC408 scintillating plastics as the time references (5 2 1 cm 3 ). This arrangement is depicted in Fig. 1. The telescope arrangement is used as the trigger that selects events hitting the two references and the tested scintillating plastics within a time window of 20 ns. The charged particles passing through the array were either cosmic rays or they came from radioactive sources. For the latter we used Na-22, Mn-54, Co-57, Fe-55, Co-60, Cs-137, Ba-133 and Cd-109, in order to choose the optimal source that provided the best statistics. III. ANALYSIS In order to test the performance of the three scintillating plastics, we first connected the Hamamatsu SiPM using a bias around 72 V. We tested the different radioactive sources and chose to use Na-22 that provides the highest number of counts. The radioactive source was located at the center of each scintillating plastic. We increased the voltage from 70 V to 72 V in steps of 0.5 V. This range corresponds to the SiPM operating voltage. For the electronics, we used a logic unit (Lecroy 365AL) and a Scaler (CAEN N1145). For each operating voltage we allowed five minutes for the light acquisition time. We observed that the BC404 is the most efficient material for the operating conditions. The comparison between the performance of our three scintillating plastics is shown in Fig. 2, from where we infer that the BC404 achieved the best light acquisition performance for the optimal bias voltage of the Hamamatsu light sensor. The output signal through the bias circuit had the orig-

3 Figure 2. Comparison between the three tested scintillating plastics. BC404 achieved the best light acquisition performance for the adequate bias voltage of the Hamamatsu light sensor. inal shape shown by the upper curve in Fig. 3. This Figure 3. Comparison between the output signal from the light sensor before (upper signal) and after (lower signal) the electronic circuit modification. signal had a recovery time of around 200 ns. After modifying the circuit, we obtained a signal having a peak time around 5 ns, and a recovery time of less than 30 ns. This is shown by the lower curve in Fig. 3. The improvement consists of adding a low value capacitor and a 50 Ω resistance to the bias circuit. The modification had the purpose to attain the same impedance for both, the bias circuit s output and the oscilloscope s input. Further improvements using similar electronic devices are shown in Fig. 4 where the complete signal is faster than 25 ns. The final bias circuit scheme is shown in the lower panel of Fig. 4. To test which of the two SiPMs leads to a better time resolution, we used a Time to Digital Converter (TDC, CAEN V775N) with VME technology to measure the time that the light produced by a charged particle (from cosmic rays) took to pass from the scintillating plastic to the light sensor. Based on calibration, we converted the TDC units to time; one TDC unit (TDCU) is equivalent Figure 4. (Top) Further improvements to the shape of the signal. (Bottom) Scheme of the circuit used to bias the light sensors, where R, C, CH, Gnd and PHD stand for Resistance, Capacitor, Channel, Ground and Photo-diode, respectively. to 0.05 ns. For the time resolution measurement, we used the BC404 scintillating material, which, according to our results, gave the best light acquisition. In addition, we used the two sensors (Hammamatsu and SensL) which were placed in three configurations on the scintillating plastic: both sensors in the middle of the same surface, one sensor on each surface, or both sensors at opposite sides. We observed that the latter configuration gives the best light acquisition. Figure 5 shows the comparison between the output signals for the two sensors for this last configuration. The analysis was performed based on the light acquisition distribution obtained when using the telescope array. As shown in Fig. 5, each of the signals

4 Figure 5. Light acquisition distribution as a function of time in TDC units for C-60035-4P-EVB (top) and S10985 (bottom) SiPMs. The comparison shows a better time resolution for the S10985 SiPM which is around 2.4 TDCU = 120 ps. consist of two peaks. This is due to the telescope-trigger used for the measurements. The procedure to clean up the signal is discussed further down in this section. From the analysis, we observe that the Hammamatsu SiPM signal is better than the SensL SiPM. The time resolution is obtained from the standard deviation of the time difference distribution between the trigger and the light sensor signal. A Gaussian fit to the first peak provides a better time resolution analysis. We infer that the SensL SiPM enables a signal with better statistics, albeit the Hamamatsu SiPM provides a better time resolution. The reason is that the peak for the BC404 emission spectrum (410 nm) is located near the Hamamatsu SiPM s maximum value for photo-detection efficiency at 450 nm [12]. Next, we focused solely on the Hamamatsu S10985 SiPM and performed further tests to improve the system s time resolution. In this analysis, we used as a trigger the coincidence between one of the telescope s scintillating detectors and the BC404-S10985 system. When using only one reference scintillating plastic we were able to obtain better statistics. The measurement and the analysis fit for the system s time resolution are shown in Figure 6. Upper pannel: Light acquisition distribution as a function of the time difference between the trigger and the SiPM s delay signal in TDCU. Lower pannel: Gaussian fit to the light acquisition distribution as a function of the time difference from where we obtained a time resolution around 97 ps. Fig. 6. We found a time resolution of 97.12±3.43 ps. Figure 7. The upper signal is the trigger when the two signals in coincidence were 4 ns wide. The lower signal shows the final width of the light sensor digital signal occurring during the trigger time.

5 Figure 8. Top: Light acquisition distribution as a function of time in TDCU, using the telescope array with the radioactive source near one sensor with the BC404 as the scintillating material. Bottom: Gaussian fits to the light acquisition distribution from where we obtained a standard deviation around 68 ps. Note the presence of the second peak (see discussion at the end of Sec. III). σ 1 and σ 2 are the sigma values of the fit for the first and second peak, respectively. In order to perform the analysis, we optimized the digital signals that define the trigger to make them finer. These signals were originally some 10 ns wide and produced a variation of the time difference that depended on the time interval when both trigger signals were in coincidence. This variation could be about 1 or 2 ns. The width of both trigger signals was finally reduced to around 4 ns. These signals are illustrated in Fig. 7. For the last measurement, the source was placed near the surface where the sensors were located in both scintillating plastics. Figure 8 shows the results of the analysis, which reveals a time resolution of 58.95±4.49 ps. Notice that the time resolution in this configuration is better than the one shown in Fig. 6. This is expected since in this configuration, the produced photons arrive faster to the sensors than for the first configuration. To summarize our time resolution measurements: For the configuration where the source is located Figure 9. Top: Light acquisition distribution as a function of the time difference between the light sensor trigger and the delay of the light sensor signal itself, in TDCU. Bottom: Gaussian fit to the light acquisition distribution from where we obtain a standard deviation σ 49.35 ps. in the middle of each scintillating plastic, the time resolution is 97.12±3.43 ps. For the configuration where the source is located near each sensor, the time resolution is 58.95±4.49 ps. The second peak in the distribution of the number of counts as a function of time has been previously studied in Ref. [13]. In order to understand the nature of this second peak, we performed tests varying the trigger conditions. When triggering only with the sensor signal, that is, without using any coincidence, the histogram shown in Fig. 9 was obtained, from where we observe that the second peak disappears and the time resolution amounts to 49.35±0.95 ps. Therefore, we attribute this second peak to the electronic trigger set up. This test gives also an estimate of the limits to the precision for the measurement of the time difference for the detection of the charged particles between the trigger and the tested scintillating plastic and sensor systems.

6 IV. DISCUSSION AND CONCLUSIONS In this work we reported on tests made for three different scintillating plastics and two SiPMs to explore what configuration provides the best time resolution to detect fast moving charged subatomic particles. We found that out of the three tested plastics, the BC404 is the most efficient. The best time resolution was obtained with the Hammamatsu SiPM. For this set of scintillating plastic/sipm combination, we performed the time resolution measurement for two configurations using a telescope trigger arrangement and a radioactive source of charged particles. We also observed that when using this trigger, it is sufficient to work with only one reference plastic. The two configurations for the time resolution measurement were: a) Sources located in the middle of each scintillating plastic and b) sources located next to each SiPM. We obtained time resolutions in the range from 58.95±4.49 ps to 97.12±3.43 ps. In addition, in order to figure out the origin of the second peak in the charge count distribution vs. time, we repeated the measurement without considering the telescope arrangement, which removes the second peak. In fact, with this configuration the time resolution improves to 49.35±0.95 ps. Based on these results, we conclude that it is possible to obtain a time resolution below 50 ps, for example, using two SiPMs or reducing the dimensions of the scintillating plastics. These results can be used to improve the design for the SiPM distribution on the scintillating plastic surface to obtain the optimal signal acquisition for the MPD beam-beam counter detector. As shown in Ref. [9], a time resolution around 45 ps can be achieved for the 5 cm heigh, 2 cm wide hexagonal tested plastic cell coupled to one SiPM. The results of this work agree with those of Ref. [9] when accounting both for the larger dimensions of the tested plastic cells and for the fact that lower energy charged particles, such as the ones obtained from the Na-22 radioactive source, are less efficiently detected [8]. Finally, we notice that the second peak in the charge distribution vs. time when using the telescope array is due to the set up electronic trigger. In order to get rid of this second peak, one can use a Constant Fraction Discriminator instead of the simple discriminator. The results of this work will be used for the final design and construction of a trigger system to be employed as part of MPD at NICA. ACKNOWLEDGMENTS Support for this work has been received in part by Consejo Nacional de Ciencia y Tecnología grant number 256494 and by UNAM-DGAPA-PAPIIT grant numbers IN107915 and IG100219. M.E.T-Y and L.V-C acknowledge the support provided by Universidad de Sonora in the initial stages of this work and the continuing support and commitment provided now by Universidad de Colima. M.R.C. thankfully acknowledges computer resources, technical advise and support provided by Laboratorio Nacional de Supercómputo del Sureste de México (LNS), a member of the Consejo Nacional de Ciencia y Tecnología network of national laboratories, with grant number No.53/Primavera 2017 and VIEP-BUAP grants 100524451-VIEP2018 and 100467555-VIEP2018. [1] F. Simon, Silicon Photomultipliers in Particle and Nuclear Physics, e-print: arxiv:1811.03877 [physics.insdet]. [2] P. W. Cattaneo et al., Development of High Precision Timing Counter Based on Plastic Scintillator with SiPM Readout, IEEE Trans. Nucl. Sci. 61, 2657-2666 (2014). [3] D. Blaschke et al., Topical issue on Exploring Strongly Interacting Matter at High Densities - NICA White Paper, Eur. Phys. J. A 52, 267 (2016). [4] V. Kekelidze, A. Kovalenko, R. Lednicky, V. Matveev, I. Meshkov, A. Sorin, G. Trubnikov, Feasibility study of heavy-ion collision physics at NICA JINR, Nucl. Phys. A 967, 884 (2017). [5] For a recent survey on theoretical studies for the location of the QCD critical end point see: A. Ayala, S. Hernández-Ortiz, L. A. Hernández, QCD phase diagram from chiral symmetry restoration: analytic approach at high and low temperature using the Linear Sigma Model with Quarks, Rev. Mex. Fis., 64, 302-313 (2018). [6] V. Golovatyuk et al., The Multi-Purpose Detector (MPD) of the collider experiment, Eur. Phys. J. A 52, 212 (2016). [7] L. Yordanova and V. Vasendina, MPD Detector at NICA, J. Phys. Conf. Ser. 503, 012041 (2014). [8] V. I. Yurevich et al., Fast forward detector for MPD/NICA project: Concept, simulation, and prototyping, Phys. Part. Nucl. Lett. 10, 258-268 (2013). [9] M. Alvarado et al. (2018), A beam-beam monitoring detector for the MPD experiment at NICA, e-print: arxiv:1809.10553 [physics.ins-det]. [10] M. I. Martínez et al., Measurement of the cosmic ray rate as a function of the altitude and atmospheric variables using a portable detector, Proc. of Sci. ICRC2017, 346 (2018). [11] SensL sense light. C-Series Low Noise, Blue- Sensitive Silicon Photomultipliers DATASHEET, http://sensl.com/downloads/ds/ds-microcseries.pdf [12] Hammamatsu MPPC (multi-pixel photon counter) Datasheets 360 powered by IEEE GlobalSpec, https://www.datasheets360.com/pdf /3352880521758237526 [13] A. Stoykov et al., A time resolution study with a plastic scintillator read out by a Geiger-mode Avalanche Photodiode, Nucl. Instrum. Meth. A, 695, 202-205 (2012).