Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded stainless steel diaphragm up to independent contacts, configurable optionally: - analogue output - Ex-protection (for -wire) nominal pressure range from 0... 00 mbar up to 0... 0 bar intelligent pressure switch digital display and has been developed for process industry; especially for food industry and pharmacy. Besides the is suitable for applications with high requirements on hygienic process connections and a rugged housing which is easy to clean. As standard the offers a PNP contact and is optionally available with a second, independent contact. Additionally the device could be equipped with an analogue output. The -wire version is also available with Exprotection. Operating The display module, which is mounted rotatable in the ball housing, shows the system pressure and allows programming. The configuration is menu controlled and easy to handle without previous knowledge. Applications process industry food industry pharmacy Characteristics indication of measured values on a -digit LED display rotatable and configurable display module configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay) option analogue output: - -wire version:... 0 ma or 0... 0 V with turn-down :6 - -wire version:... 0 ma Ex-protection optionally special functions (access protection, min. / max. value memory) industrial standard in view of accuracy, thermal behaviour and long term stability
Input pressure range Nominal pressure gauge [bar] -... 0 0. 0.5 0..5 0 5 0 Nominal pressure abs. [bar] - - - -.5 0 5 0 Permissible overpressure [bar] 6 0 60 60 00 Number, type standard: PNP contact option: independent PNP contacts Max. switching current -wire: contact rating 5 ma, short-circuit resistant; V switch = V S V Accuracy of contacts -wire: contact rating 500 ma, short-circuit resistant IEC 60770 BFSL standard: nominal pressure > 0. bar: nominal pressure 0. bar: ± 0.5 % FSO ± 0.50 % FSO ± 0.75 % FSO ± 0.50 % FSO option: nominal pressure > 0. bar: ± 0.5 % FSO ± 0.5 % FSO Repeatability ± 0, % FSO Switching frequency -wire: max. 0 Hz / -wire: 50 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec. with Ex-protection max. contact possible Analogue output (optionally) / Supply -wire current signal... 0 ma / V S = 8... V DC = [(V S V S min ) / 0.0] Ω response time: < 0 ms -wire current signal with Ex-protection... 0 ma / V S = 7... 8 V DC = [(V S V S min ) / 0.0] Ω response time: < 0 ms -wire current signal... 0 ma / V S = V DC ± 0 % adjustable (turn-down of span :6) = 500 Ω response time: < 0 ms -wire voltage signal 0 0 V / V S = V DC ± 0 % adjustable (turn-down of span :6) permissible load: R min = 0 kω response time: < 0 ms Without analogue output V S = 5... 6 V DC Accuracy IEC 60770 BFSL standard: nominal pressure > 0. bar: nominal pressure 0. bar: ± 0.5 % FSO ± 0.50 % FSO ± 0.75 % FSO ± 0.50 % FSO option: nominal pressure > 0. bar: ± 0.5 % FSO ± 0.5 % FSO with turn-down of span the analogue signal is adjusted automatically to the new measuring range accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal errors (offset and span) / Permissible temperatures Nominal pressure P N [bar] -... 0 0. 0.5 0. > Tolerance band [% FSO] ± 0.75 ± ±.5 ± ± ± 0.75 TC, average [% FSO / 0 K] ± 0. ± 0. ± 0. ± 0. ± 0.5 ± 0. in compensated range [ C] 0... 70 0... 50 0... 70 Permissible temperatures medium: -5... 5 C 5 electronics / environment: -5... 85 C storage: -0... 85 C an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions 5 for vacuum ranges and nominal pressure abs. the max. medium temperature is 70 C; with optional cooling element its maximum permissible temperature is valid Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration Shock Filling fluids Standard Optional Materials 5 g RMS (0... 000 Hz) 00 g / msec. Silicon oil food compatible oil (with FDA approval) / Halocarbon and others Pressure port stainless steel.5 (6L) Housing stainless steel.0 (0) Viewing glass laminated safety glass Seals (media wetted) inch thread: standard: FKM (recommended for medium temperatures 00 C) optionally: FFKM (recommended for medium temperatures > 00 C); others clamp and dairy pipe: without Diaphragm stainless steel.5 (6L) Media wetted parts pressure port, seals, diaphragm pressure measurement
Explosion protection (optionally for 0 ma / -wire) Approval AX-DS 00P Safety technical maximum values Max. switching current 6 Permissible temperatures for environment Connecting cables (by factory) zone 0: II G EEx ia IIC T U i = 8 V, I i = 9 ma, P i = 660 mw 70 ma in zone 0: -0... 60 C with p atm 0.8 bar up to. bar in zone : -5... 70 C cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m 6 the real switching current in the application depends on the power supply unit Miscellaneous Display Current consumption (without contacts) Ingress protection IP 67 Installation position any 7 Weight Operational life -digit, 7-segment-LED display, visible range 7. x mm; digit height 0 mm, range of indication -999... +9999; accuracy 0.% ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) -wire signal output current: max. 5 ma -wire signal output current: approx. 0 ma + signal current -wire signal output voltage: approx. 0 ma min. 500 g (depending on mechanical connection) > 00 x 0 6 cycles 7 Pressure switches are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviation in the zero point for pressure ranges bar. Therefore installation position has to be given in this case. Wiring diagrams -wire-system (current) p -wire-system (current / voltage) p V S V S Signal + A / V I Contact I/U Contact Pin configuration Electrical connection Signal + (only -wire) Contact Ground Mx metal (5-pin) 5 plug housing / pressure port cable colours (DIN 700) white brown green grey pink yellow / green (shield) Electrical connection (dimensions in mm) Mx (5-pin) cable outlet 8 8 different cable types and lengths available
Designs 9 side display 5 display () top display () 9 all designs in horizontal rotatable housing as standard Mechanical connections (dimensions in mm) G flush (DIN 85) Dairy pipe (DIN 85) Clamp (ISO 85) Cooling element flush diaphragm D dimensions in mm size DN 5 DN 0 DN 50 A.5 B.5 C 56 68.5 D 5 flush diaphragm D dimensions in mm size / A B C 50.5 50.5 6 D 5 Total length of devices with Ex-protection increases by 0 mm! temperature range 50 C 00 C size A number of cooling fins This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. pressure measurement
Ordering code DS 00P DS 00P - - - - - - - - - - - Pressure gauge 7 A 5 absolute, 7 A 6 Input [bar] 0,0 0 0 0 0,5 5 0 0 0,0 0 0 0,0 0 0,5 5 0,0 0 0 0 0 0 5 5 0 0 0 0-0 X 0 9 9 9 9 Design (side display) (5 display) K H K (top display) K V Analogue output without 0 ma / -wire 0 0 V / -wire, adjustable 0 ma / -wire, adjustable 0 7 Intrinsic safety 0 ma / -wire E 9 Contact contact contacts Accuracy standard for P N > 0, bar 0,5 % standard for P N 0, bar 0,5 % 5 option for P N > 0, bar 0,5 % 9 Electrical connection Mx (5-pin) / metal version N 0 Cable outlet T A 0 9 9 9 Mechanical connection G" with flush welded diaphragm (DIN 85) Clamp " (ISO 85) Clamp /" (ISO 85) Clamp " (ISO 85) Z C 6 C 6 C 6 Dairy pipe DN 5 (DIN 85) 5 M 7 Dairy pipe DN 0 (DIN 85) 5 M 7 5 Dairy pipe DN 50 (DIN 85) 5 M 7 6 9 9 9 Diaphragm Stainless steel.5 (6L) 9 Seals for clamp or dairy pipe: none 0 for inch thread: FKM FFKM 7 9 Filling Fluids Silicon oil food compatible oil 6 Halocarbon C 9 Special version standard with cooling element up to 50 C with cooling element up to 00 C 0 0 0 5 0 0 0 9 9 9 absolute pressure possible from bar for vacuum and nominal pressure abs. the max. medium temperature is 70 C with Ex version max. contact is possible different cable types and lengths deliverable (not encluded in the price); code for PVC cable without ventilation tube 5 The cup nut for dairy pipe has to be mounted by production of pressure transmitter. The cup nut for dairy pipe has to be ordered as separate position. 6 Name of oil: Mobil DTE FM ; Category Code: H; NSF Registration No.: 066 0008 This ordering code contains product specification; properties are not guaranteed. Subject to change without notice.