DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Similar documents
DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 331i / DMP 333i LMP 331 i

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Pressure transmitter For applications in hazardous areas Model IS-3

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Selection matrix for electronic pressure switches

Pressure transmitter COMPACT IO-Link,

Single Point Flow Monitor SW118 SW119

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI3-EG08K-Y1-H1341

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor BI1.5-EG08K-Y1

Mechanical flow switch for On/Off control

PROPORTIONAL VALVES Sentronic plus

Micro-Machined Silicon Transducers

Panel-mounting thermostats, type series EM

Quality products from a single source

TFRN Industrial RTD temperature sensor. CombiTemp TM

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Photoelectrics Through-beam Type PA18C.T..., DC

Inductive sensor With analog output BI15-M30-LI-EXI

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

TFRH Hygienic RTD temperature sensor. CombiTemp TM

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Absolute Encoders Multiturn

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

APPLICATIONS. Automatic warehouse. Trasportation lines

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

TFRN Industrial RTD temperature sensor. CombiTemp TM

Linear encoders without bearings incremental System for linear motion feedback

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

TFR5 Room or outdoor temperature sensor. CombiTemp TM

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Process transmitter RMA422

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Process Transmitter RMA 422

RSCC. Load cells. Special features. Data sheet

Panel-Mounted Thermostat

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Level Measurement silometer FMC 420, FMC 423

Linear flow control with actuator IFC

Electrical connection

SPACESCAN SERIES SS 02

Capacitive sensor BCT5-S18-UP6X2T-H1151

SERIES 400 SERIES 620

Capacitance Level Measurement Electronic insert FEC 12

APPLICATIONS. Automatic warehouse. Trasportation lines

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Standard signal metering in wall-mounting case

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Signet 2250 Hydrostatic Level Sensor

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

The full range of performance

Speed sensor MiniCoder GEL 2471

Linear flow controls VFC Linear flow controls with actuator IFC

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

IONIVAC Transmitter ITR 90

Eddy Current Probe System

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Flow Switch. Flow Switch

82540/ /2-way diaphragm valves

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

Electrical connection

Photoelectric Sensors E3F2

ATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Transcription:

Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded stainless steel diaphragm up to independent contacts, configurable optionally: - analogue output - Ex-protection (for -wire) nominal pressure range from 0... 00 mbar up to 0... 0 bar intelligent pressure switch digital display and has been developed for process industry; especially for food industry and pharmacy. Besides the is suitable for applications with high requirements on hygienic process connections and a rugged housing which is easy to clean. As standard the offers a PNP contact and is optionally available with a second, independent contact. Additionally the device could be equipped with an analogue output. The -wire version is also available with Exprotection. Operating The display module, which is mounted rotatable in the ball housing, shows the system pressure and allows programming. The configuration is menu controlled and easy to handle without previous knowledge. Applications process industry food industry pharmacy Characteristics indication of measured values on a -digit LED display rotatable and configurable display module configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay) option analogue output: - -wire version:... 0 ma or 0... 0 V with turn-down :6 - -wire version:... 0 ma Ex-protection optionally special functions (access protection, min. / max. value memory) industrial standard in view of accuracy, thermal behaviour and long term stability

Input pressure range Nominal pressure gauge [bar] -... 0 0. 0.5 0..5 0 5 0 Nominal pressure abs. [bar] - - - -.5 0 5 0 Permissible overpressure [bar] 6 0 60 60 00 Number, type standard: PNP contact option: independent PNP contacts Max. switching current -wire: contact rating 5 ma, short-circuit resistant; V switch = V S V Accuracy of contacts -wire: contact rating 500 ma, short-circuit resistant IEC 60770 BFSL standard: nominal pressure > 0. bar: nominal pressure 0. bar: ± 0.5 % FSO ± 0.50 % FSO ± 0.75 % FSO ± 0.50 % FSO option: nominal pressure > 0. bar: ± 0.5 % FSO ± 0.5 % FSO Repeatability ± 0, % FSO Switching frequency -wire: max. 0 Hz / -wire: 50 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec. with Ex-protection max. contact possible Analogue output (optionally) / Supply -wire current signal... 0 ma / V S = 8... V DC = [(V S V S min ) / 0.0] Ω response time: < 0 ms -wire current signal with Ex-protection... 0 ma / V S = 7... 8 V DC = [(V S V S min ) / 0.0] Ω response time: < 0 ms -wire current signal... 0 ma / V S = V DC ± 0 % adjustable (turn-down of span :6) = 500 Ω response time: < 0 ms -wire voltage signal 0 0 V / V S = V DC ± 0 % adjustable (turn-down of span :6) permissible load: R min = 0 kω response time: < 0 ms Without analogue output V S = 5... 6 V DC Accuracy IEC 60770 BFSL standard: nominal pressure > 0. bar: nominal pressure 0. bar: ± 0.5 % FSO ± 0.50 % FSO ± 0.75 % FSO ± 0.50 % FSO option: nominal pressure > 0. bar: ± 0.5 % FSO ± 0.5 % FSO with turn-down of span the analogue signal is adjusted automatically to the new measuring range accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal errors (offset and span) / Permissible temperatures Nominal pressure P N [bar] -... 0 0. 0.5 0. > Tolerance band [% FSO] ± 0.75 ± ±.5 ± ± ± 0.75 TC, average [% FSO / 0 K] ± 0. ± 0. ± 0. ± 0. ± 0.5 ± 0. in compensated range [ C] 0... 70 0... 50 0... 70 Permissible temperatures medium: -5... 5 C 5 electronics / environment: -5... 85 C storage: -0... 85 C an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions 5 for vacuum ranges and nominal pressure abs. the max. medium temperature is 70 C; with optional cooling element its maximum permissible temperature is valid Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration Shock Filling fluids Standard Optional Materials 5 g RMS (0... 000 Hz) 00 g / msec. Silicon oil food compatible oil (with FDA approval) / Halocarbon and others Pressure port stainless steel.5 (6L) Housing stainless steel.0 (0) Viewing glass laminated safety glass Seals (media wetted) inch thread: standard: FKM (recommended for medium temperatures 00 C) optionally: FFKM (recommended for medium temperatures > 00 C); others clamp and dairy pipe: without Diaphragm stainless steel.5 (6L) Media wetted parts pressure port, seals, diaphragm pressure measurement

Explosion protection (optionally for 0 ma / -wire) Approval AX-DS 00P Safety technical maximum values Max. switching current 6 Permissible temperatures for environment Connecting cables (by factory) zone 0: II G EEx ia IIC T U i = 8 V, I i = 9 ma, P i = 660 mw 70 ma in zone 0: -0... 60 C with p atm 0.8 bar up to. bar in zone : -5... 70 C cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m 6 the real switching current in the application depends on the power supply unit Miscellaneous Display Current consumption (without contacts) Ingress protection IP 67 Installation position any 7 Weight Operational life -digit, 7-segment-LED display, visible range 7. x mm; digit height 0 mm, range of indication -999... +9999; accuracy 0.% ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) -wire signal output current: max. 5 ma -wire signal output current: approx. 0 ma + signal current -wire signal output voltage: approx. 0 ma min. 500 g (depending on mechanical connection) > 00 x 0 6 cycles 7 Pressure switches are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviation in the zero point for pressure ranges bar. Therefore installation position has to be given in this case. Wiring diagrams -wire-system (current) p -wire-system (current / voltage) p V S V S Signal + A / V I Contact I/U Contact Pin configuration Electrical connection Signal + (only -wire) Contact Ground Mx metal (5-pin) 5 plug housing / pressure port cable colours (DIN 700) white brown green grey pink yellow / green (shield) Electrical connection (dimensions in mm) Mx (5-pin) cable outlet 8 8 different cable types and lengths available

Designs 9 side display 5 display () top display () 9 all designs in horizontal rotatable housing as standard Mechanical connections (dimensions in mm) G flush (DIN 85) Dairy pipe (DIN 85) Clamp (ISO 85) Cooling element flush diaphragm D dimensions in mm size DN 5 DN 0 DN 50 A.5 B.5 C 56 68.5 D 5 flush diaphragm D dimensions in mm size / A B C 50.5 50.5 6 D 5 Total length of devices with Ex-protection increases by 0 mm! temperature range 50 C 00 C size A number of cooling fins This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. pressure measurement

Ordering code DS 00P DS 00P - - - - - - - - - - - Pressure gauge 7 A 5 absolute, 7 A 6 Input [bar] 0,0 0 0 0 0,5 5 0 0 0,0 0 0 0,0 0 0,5 5 0,0 0 0 0 0 0 5 5 0 0 0 0-0 X 0 9 9 9 9 Design (side display) (5 display) K H K (top display) K V Analogue output without 0 ma / -wire 0 0 V / -wire, adjustable 0 ma / -wire, adjustable 0 7 Intrinsic safety 0 ma / -wire E 9 Contact contact contacts Accuracy standard for P N > 0, bar 0,5 % standard for P N 0, bar 0,5 % 5 option for P N > 0, bar 0,5 % 9 Electrical connection Mx (5-pin) / metal version N 0 Cable outlet T A 0 9 9 9 Mechanical connection G" with flush welded diaphragm (DIN 85) Clamp " (ISO 85) Clamp /" (ISO 85) Clamp " (ISO 85) Z C 6 C 6 C 6 Dairy pipe DN 5 (DIN 85) 5 M 7 Dairy pipe DN 0 (DIN 85) 5 M 7 5 Dairy pipe DN 50 (DIN 85) 5 M 7 6 9 9 9 Diaphragm Stainless steel.5 (6L) 9 Seals for clamp or dairy pipe: none 0 for inch thread: FKM FFKM 7 9 Filling Fluids Silicon oil food compatible oil 6 Halocarbon C 9 Special version standard with cooling element up to 50 C with cooling element up to 00 C 0 0 0 5 0 0 0 9 9 9 absolute pressure possible from bar for vacuum and nominal pressure abs. the max. medium temperature is 70 C with Ex version max. contact is possible different cable types and lengths deliverable (not encluded in the price); code for PVC cable without ventilation tube 5 The cup nut for dairy pipe has to be mounted by production of pressure transmitter. The cup nut for dairy pipe has to be ordered as separate position. 6 Name of oil: Mobil DTE FM ; Category Code: H; NSF Registration No.: 066 0008 This ordering code contains product specification; properties are not guaranteed. Subject to change without notice.