Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

Similar documents
Madero Ote. 686, Centro Histórico, C.P Morelia, Michoacán México. #300, Col. Cuauhtémoc, C.P Morelia, Michoacán, México

Understanding CT image quality

IAEA RER/9/135 COURSE ON OPTIMIZATION IN COMPUTED TOMOGRAPHY Sofia, Bulgaria, Tube current modulation and dose reduction : How TCM works

Comparison of Measured Values of CTDI and DPL with Standard Reference values of Different CT Scanners for dose Management

2

A simple anthropomorphic phantom used to demonstrate the effectiveness of CT dose modulation functions.

Iterative Reconstruction with Philips idose Characterising Image Quality in Attempting to Realise its Potential

RSNA 2006 November 26 to December 1 Chicago. Guest author for ImPACT Dr. Koos Geleijns, Medical Physicist, Leiden University Medical Center.

A method for calculating the dose length product from CT DICOM images

Equipment Quality Control for Digital Radiography February 22, Imaging Physics CancerCare Manitoba

QUALITY CONTROL AND PATIENT DOSES FROM X-RAY EXAMINATIONS IN SOME HOSPITALS IN THAILAND

What do we mean by workload? Number of scans Type of scans/mix of scans? Total mas Total dip

In recent years, CT technology has undergone profound

NEMA XR 25 COMPUTED TOMOGRAPHY DOSE CHECK

Request for Proposals

Scope: All CT staff technologist

2017 Computed Tomography

2012 Computed Tomography

Standard. Substitute Test or Procedure. Required Test or. 1 Scan Increment Accuracy. Initially and Annually Initially and Annually

Brilliance CT 64-channel configuration

Vascular. Development of Trinias FPD-Equipped Angiography System. 1. Introduction. MEDICAL NOW No.73 (2013.2) Yoshiaki Miura

Imaging diagnostico in Sanità Stato attuale e prospettive

using the Scott A Speakman, Ph.D Center for Materials Science and Engineering at MIT

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

Precision, power, and productivity

Quality Assurance Implementation at the Roberts Proton Therapy Center. James McDonough 3 August 2013

UArm. Series. Analog or Digital U-Arm System

CT Numbers: Think of a number, double it, add 20, divide by 4. Jane Edwards Royal Free Hospital, London

Staff dose and good prac/ces in CT guided IR procedures. Jonas Andersson Medical Physicist, Ph.D.

HV/PHA Adjustment (PB) Part

-Technical Specifications-

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

X-Ray Machines, CT Scanners, MRIs: The Pivotal Role of the GE Research and Development Center

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Ergonomic design packed with powerful performance MULTIMOBIL 5C. Answers for life.

Operating Procedures for RECO1 & RECO2

CNC872 Series CNC System Application for Cutting Machines

Guidelines for Quality Assurance in Radiation Protection for Diagnostic X-Ray Facilities: Large X-Ray Facilities

True comfort and flexibility with the power of 3T.

Performance Evaluation of Industrial Computed Radiography Image Display System

Overview. ACR Accreditation Update in Mammography. ACR Topics. Requirements Today. What s Coming For Tomorrow

Phantom Test Guidance for Use of the Small MRI Phantom for the MRI Accreditation Program

Data Collection Using APEX3. March 30, Chemical Crystallography Laboratory

Physics Requirements for the CXI Ion Time-of-Flight

DOSE DELIVERY SYSTEM OF THE VARIAN PROBEAM SYSTEM WITH CONTINUOUS BEAM

FDA MAMMOSCAN FULL FIELD DIGITAL MAMMOGRAPHY SYSTEM MAMMOGRAPHY

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

A new shielding calculation method for X-ray computed tomography regarding scattered radiation

Imaging solutions for any size patient and any size budget.

More Info at Open Access Database Process Control for Computed Tomography using Digital Detector Arrays

LightSpeed 16 With Xtream CT Scanner System

Collimation and Light Field Brightness

Practix. Mobile Radiography. All a Bucky station needs plus mobility. Practix 400

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING

RADIOGRAPHIC PERFORMANCE OF CYGNUS 1 AND THE FEBETRON 705

CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide

THE OPERATION OF A CATHODE RAY TUBE

There are many ham radio related activities

Procedures for conducting User QA on the scanner

Dental Line. High frequency intraoral x-ray unit. radiology ahead

X-ray Tube Housing Assembly H1076X H1076Y Print No.HA Release Date:

INSTRUMENT CATHODE-RAY TUBE

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

Intra-oral X-ray unit with high frequency DC generator. Product Data

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

High Frequency X-Ray Technology. Wide Screen Control with Touch-Technology

Assessment of the Impact of Dark Signal on Image Quality in Computerized Mammography. Introduction

YXLON Cougar EVO PLUS

Department of Medical Physics, Graduate School of Nuclear and Allied Science, University of Ghana, Accra - Ghana, West Africa

THE OPERATION OF A CATHODE RAY TUBE

Introduction. Edge Enhancement (SEE( Advantages of Scalable SEE) Lijun Yin. Scalable Enhancement and Optimization. Case Study:

Non-Destructive Examination Benches and Analysis Laboratories in support to the Experimental Irradiation Process in the Future Jules Horowitz MTR

XRD-DSC Sample Alignment (BB) Part

ISOMET. Compensation look-up-table (LUT) and How to Generate. Isomet: Contents:

Built to do More. Brivo CT slice CT product data sheet

Initial Experience With Automatic Image Transmission to an Intensive Care Unit Using Picture Archiving and Communications System Technology

MPKOMNP. kéï=~ë=çñw== d^ifiblp. j~áåíéå~ååé=fåëíêìåíáçåë=d^ifiblp=`çãñçêí=mirp. båöäáëü. Cover page

The Black Piranha Easy & Fast X-ray Quality Control

From Autonomous Subsystems to Integrated System

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Cosmos2 The Economical X-ray Solution with the Best Image Quality and High Reliability

Mechanical Considerations in the Outer Tracker and VXD. Bill Cooper Fermilab

Contents. 1. System Description 3. Overview 3 Part Names 3 Operating Conditions 7 Start-up Procedure 7. 2.

3B SCIENTIFIC PHYSICS

Selection Criteria for X-ray Inspection Systems for BGA and CSP Solder Joint Analysis

Biograph Vision See a whole new world of precision

Lesson 07: Ultrasound Transducers. This lesson contains 62 slides plus 16 multiple-choice questions.

Academic and Research Staff. Prof. John G. King Dr. John W. Coleman Dr. Edward H. Jacobsen. Norman D. Wittels

National Institute of Radiological Sciences. Naoya Saotome

Implementing a Proton Beam Scanning System within an Operating Clinical Facility

OSCILLOSCOPE AND DIGITAL MULTIMETER

Scanning Electron Microscopy (FEI Versa 3D Dual Beam)

New Rotary Magnetron Magnet Bar Improves Target Utilization and Deposition Uniformity

Promises and Perils of Proton Therapy Beam Delivery (Implications) or Towards Cost Effective Particle Therapy

Corrigendum-II. Up to 30 th October 2018 till 17:00 Hrs. 31 st October 2018 till 17:00 Hrs. 2 nd November 2018 till 14:00 Hrs.

Optima CT660 Optima CT660

Personal Protective Equipment Wear nitrile gloves, lab coat, and safety glasses as a minimum protection, unless otherwise indicated.

Commissioning of the ATLAS Transition Radiation Tracker (TRT)

Polygon Scanners Capabilities, Applications and System integration. considerations

New Medical Light Source using NTT s Communication Laser Technology

Transcription:

2033-17 Joint ICTP/ Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation 11-15 May 2009 Dosimetry for CT 3: Practical Experiences Claire-Louise Chapple Freeman Hospital Newcastle UK

Joint ICTP- Advanced school on Dosimetry in Diagnostic Radiology: And its Clinical Implementation 11-15 May 2009; Miramare, Trieste, Italy Dosimetry for CT (3) Practical Experiences Claire-Louise Chapple Regional Medical Physics Department Freeman Hospital Newcastle upon Tyne, UK International Atomic Energy Agency

Practical issues Dosemeter calibration & correction coefficients Setting scanner up Collecting data interpreting parameters Scan projection radiography Worked examples for patient dosimetry

CT chamber calibration factors CoP assumes CT chambers calibrated in terms of dose length product (mgy cm / digit) eg at SSDL Many are calibrated in terms of mgy /digit If this is the case, the chamber length (10cm) needs to be included extra factor of 10 in equations, or in cal coeff

Beam quality correction coefficient Factor k Q may not be available Should know the beam quality at calibration If calibration quality inappropriate for CT, user determination of k Q may be necessary Ensure correct uncertainty scenario used

Setting scanner up for measurements Single axial slices required may need to be in engineer mode password usually required look for axial / sequential protocol and change number of slices May need to adapt chamber support for in air measurements Overscan needs to be switched off (if possible)

Effect of overscan Distribution of air kerma in peripheral slots may not be uniform voltage ramping overscan If position of maximum air kerma constant, position phantom with 1 peripheral slot in this position If variable, either fix start angle or take multiple measurements

Correction for helical overscan Correction factor can be measured using the CT ionization chamber as described by IPEM Obtained by scanning slightly more than the entire length of the chamber in axial and then helical mode same collimated beam width is used for both scans axial scans should be contiguous and the helical scan should have a pitch of 1 measurement is made with the chamber positioned along the scanner axis and free-in-air

Collecting patient data For multi-slice (multi-detector) CT, care should be taken to correctly interpret parameters N, the number of simultaneously acquired slices per rotation (also referred to as the number of data channels used during the acquisition) T the nominal thickness of each acquired slice (which is not necessarily the same as the nominal width of the reconstructed slice). Product NT should reflect the total nominal width of the X ray beam.

Nominal slice width in multi-slice scanning Multiple narrow beams eg 4 x 1mm 4 x 2mm 4 x 5mm 4 x 10mm 4 mm 8 mm 20 mm 40 mm Nominal slice width is total beam width for 1 rotation

Tube current modulation Many scanners now use tube current modulation techniques to reduce patient dose so that the tube current may vary continuously as the scanner rotates or may change for each successive rotation. When calculating the air kerma length product, P KL,CT, it is important to use the actual values of the tube loading for the complete helical scan or for each axial scan as appropriate. Alternatively, for helical scans, the product of the average tube current and total scan time can be used.

Effective mas (P IT ) Care should be taken when recording values of tube current as some scanners give values of an effective tube current which varies with pitch rather than the actual tube current. P ITeff = P ITrot / pitch

Calculation of P KL,CT P KL,CT = C VOL x scan length = nl C VOL = nl n C w P ITeff = nl n C w P IT NT/l = NT n C w np IT = NT n C w P ITtot =l n C VOL P ITtot l is the distance moved by the couch per scanner rotation n number of rotations P ITeff effective mas/slice P IT mas/rotation P ITtot total mas/scan (= ma x total scan time) NT nominal slice width NB Units mgy cm

Extra Note (just to complicate things..) Siemens Sensation 64 uses dual focus technology for all 0.6mm detector settings This produces 2 sets of overlapping data using same detector bank Thus, 64 x 0.6mm corresponds to a nominal slice width of 32 x 0.6mm (extra slices are from second focal spot not additional detectors)

Dosimetry for Scan Projection Radiograph Typically 3% total dose Use the CT ionisation chamber to measure the incident air kerma for the SPR Done in absence of patient or phantom using the CT ionisation chamber supported at the appropriate height above the couch top and aligned parallel to the axis of rotation of the scanner Scanner settings should be those for the SPR and the scan length should exceed the length of the ionization chamber (100 mm)

Example 1 : Single slice scanner Abdomen CT 10mm slice width, 15mm increment 200 mas / rotation, 25 slices nc w 0.008 mgy/mas C VOL = n C VOL P IT C n VOL = n C W NT l C vol = 0.008 x 200 x 1x10 15 = 1.07 mgy

Example 1 : Single slice scanner Abdomen CT 10mm slice width, 15mm increment 200 mas / rotation, 25 slices nc w 0.008 mgy/mas C vol = 1.07 mgy P KL,CT = nl C VOL P KL,CT = 1.07 x 25 x1.5 = 40 mgycm P KL,CT = NT n C w P ITtot P KL,CT = 1.0 x 0.008 x 200 x 25 = 40 mgycm

Example 2 :Siemens Multislice Scanner Abdomen CT 4x5mm slices, Pitch 1.2 220 effective mas, total mas 9240 nc w 0.008 mgy/mas C VOL = n C w P ITeff C vol = 0.008 x 220 = 1.76 mgy

Example 2 :Siemens Multislice Scanner Abdomen CT 4x5mm slices, Pitch 1.2 220 effective mas, total mas 4240 nc w 0.008 mgy/mas C vol = 1.76 mgy P KL,CT = NT n C w P ITtot P KL,CT = 4x5 x 0.008 x 4240= 68 mgycm 10

Example 3 :Philips Multislice Scanner Abdomen CT 4x5mm slices, Pitch 1.2 220 effective mas, Scan length 400mm nc w 0.008 mgy/mas C VOL = n C w P ITeff C vol = 0.008 x 220 = 1.76 mgy

Example 3 :Philips Multislice Scanner Abdomen CT 4x5mm slices, Pitch 1.2 220 effective mas, Scan length 400mm nc w 0.008 mgy/mas C vol = 1.76 mgy P KL,CT = C VOL x scan length P KL,CT = 400 x 1.76= 70 mgycm 10

Final tips Know your scanner! Collect scanner displayed values of DLP, but check/calibrate them Adjust data collection forms for scanner type (so radiographers understand clearly which parameters to record) Total mas / DLP likely to be most accurate for helical multi-slice scanners (includes extra slices & hopefully ma modulation)