RIDA GENE Color Compensation Kit I

Similar documents
LEGEND MAX Human α-synuclein ELISA Kit with Pre-coated Plate Catalog No.: (Previously Covance Cat. No. SIG-38974)

Fragment Analyzer Genomic DNA Analysis Kit

Fragment Analyzer CRISPR Discovery Gel Kit

MANUAL Real time one step

Fragment Analyzer Genomic DNA Analysis Kit

Amplification Setup Methods for the Maxprep TM Liquid Handler Technical Manual

Digital PCR Analysis Software version 3

Fragment Analyzer SS NGS, HS NGS & RNA Analysis Kits

QUICK REFERENCE INSTRUCTIONS For use with Sofia and Sofia 2.

Q-Rex Absolute Quantification HID Plug-in User Manual

USER GUIDE. for. Automated purification of DNA from Plant leaves and seeds with

Real-Time PCR System TC

Sofia Strep A FIA Page 1 of 5

USER GUIDE. for. Automated purification of DNA from cells or tissue samples with

SediVue Dx * Urine Sediment Analyzer User Guide

USER GUIDE. for. Automated purification of DNA from human or animal blood samples with

Members QUICK REFERENCE GUIDE

ab FirePlex Immunoassay Human Key Cytokines 17-plex Protocol Booklet

SECTOR Imager Performance Qualification Kit

Quick Start Guide. Multidimensional Imaging

RQflex 10. Manual English

bio bas.1 USER S MANUAL

How-to Setup Motion Detection on a Dahua DVR/NVR

HV/PHA Adjustment (PB) Part

Vinmetrica SC-200 User Manual

Analysis and sorting of cells with FACSAria II flow cytometer Tiina Pessa-Morikawa / Revised

Import and quantification of a micro titer plate image

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

AU5800 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU5800 Weekly (Analyzer and ISE) Maintenance

User Manual OVP Raman

1. Add Capture Antibody diluted in coating buffer. 4. Add standards, controls and samples to the plate in duplicate.

FACSAria I Standard Operation Protocol Basic Operation

What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven

Deltasoft Services M A N U A L LIBRARY MANAGEMENT. 1 P a g e SCHOOL MANAGEMENT SYSTEMS. Deltasoft. Services. User Manual. Aug 2013

Calibrating and Profiling Your Monitor

extra Liquid Handling Precision Laboratory ConsumablesV 5 : Proline Plus Mechanical Pipettes Ask about our Pettecheck pipette service & calibration!

Confocal Application Notes Vol. 2 May 2004

Standard Operating Procedure Of The CytoFLEX S Flow Cytometer At The Institute Of Virology

My XDS Receiver- Affiliate Scheduler

Standard Operating Procedure II: EDS (Bruker Flat-Quad)

MR.SPOT Processor REF User Manual

APP USE USER MANUAL 2017 VERSION BASED ON WAVE TRACKING TECHNIQUE

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

SIDRA INTERSECTION 8.0 UPDATE HISTORY

EndNote Web Getting Started

MR.SPOT Processor REF User Manual

NimbleGen Arrays User s Guide. CGH Analysis. For life science research only.

Checking the fluids of the cart

EndNote X6 Workshop Michigan State University Libraries

CytoFLEX Flow Cytometer Quick Start Guide

READ THIS FIRST. Morphologi G3. Quick Start Guide. MAN0412 Issue1.1

Silver Mountain Targets V2 Software Reference Guide. July 22, 2015

QuantaSoft Version 1.7 Regulatory Edition Software

Operating Instructions for Scanmark insight 4ES Scanner with QuickScore

rekordbox TM LIGHTING mode Operation Guide

Mitsubishi Electric Air Conditioning Network System Integrated centralized control software TG-2000A Operation Manual (Management)

Practicality and Performance

Ministry of Transportation. WBCMS Manual. Inspector s Guide. Contract Management and Operations Branch

OPERATION MANUAL. TECHNOS Co.,Ltd. Total Reflection X-ray Fluorescence Spectrometer

CFlow User Guide. Science is hard. Flow cytometry should be easy.

Mendeley Basics. Get Mendeley. Get Articles and Documents into Mendeley. Import Citations from a Website

CA Outbound Dialer Module. Operation Manual v1.1

rekordbox TM LIGHTING mode Operation Guide

FD400Multi Function Decoder. User Manual. 04/2013

MR.SPOT Processor REF User Manual

SR-D8-M, SR-D8-S. (Ver ) SOFTWARE INSTRUCTIONS

FEI FIB Focused Ion Beam

GVD-120 Galvano Controller

Calibration Using i1 probe with CalMan and Resolve

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework

Release Notes for LAS AF version 1.8.0

Standard Operating Procedure Aria III - Irchel

OLED THE PERFECT HIGH-RESOLUTION DISPLAY

Source/Receiver (SR) Setup

IPTV Smarters - TV Box Customization. Good News for IPTV Smarters TV Box Users!

D-901 PC SOFTWARE Version 3

X-Sign 2.0 User Manual

ST9100C User Guide. Features

FOR MEDIA SAMPLING INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

SNR Playback Viewer SNR Version 1.9.7

Rapid Solutions for Processing Swabs & Punches PunchSolution and SwabSolution Kits 5X AmpSolution Reagent

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

MicroMax 384. Operation Manual Rev Fax: (33) 1/ U.K.: 020/

Precautions and Disclaimers What You Can Do with Geometry Manager Pro Check Your Computer System requirements...

Initially, you can access the Schedule Xpress Scheduler from any repair order screen.

Amazon Account 3/14 TM 1

Manual. Kingpad mc-edition light-module. Bus system control pad for installation in the Graupner mc-16 / mc-20 / mc-26 / mc-28 transmitter

eblot L1 Protein Transfer System Fast Wet Transfer System for Mini Gels

InPlace User Guide for Faculty of Arts, Education and Social Sciences Staff

Differential Scanning Calorimetry (DSC) Of Powder Coating Materials

Tools, Tips, and Workflows Monochromatic/Hillshade Displays in LP360 LP360,

Troubleshooting the CTS 1100

... read The Art of Tap Tuning by Roger H. Siminoff (Hal Leonard Publishing).

Cisco Spectrum Expert Software Overview

ZX-44XL Liquid Fuel Analyzer. User s Manual Version 1.2

OPERATING INSTRUCTIONS TOM-0431IP

CLIPSTER. 3D LUT File Generation with the Kodak Display Manager. Supplement

Ultra 4K Tool Box. Version Release Note

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

FACTORY AUTOMATION. MANUAL VAZ-ANALYZER Innovation Step 2

Transcription:

RIDA GENE Color Compensation Kit I Art. No.: PG0001 3 reactions -20 C R-Biopharm AG, An der neuen Bergstraße 17, D-64297 Darmstadt, Germany Tel.: +49 (0) 61 51 81 02-0 / Telefax: +49 (0) 61 51 81 02-20

1. Intended use RIDA GENE Color Compensation Kit I is intended for generating a Color Compensation File for multiplex real-time PCR experiments on the LightCycler 480. The generated Color Compensation File can be applied to analyze multiplex real-time PCR experiments of RIDA GENE real-time PCR kits on the LightCycler 480. 2. Explanation of the test In a multiplex real-time PCR, the wavelengths of light emitted by the reporter dyes may overlap, causing one channel to pick up signals (crosstalk) from a dye measured by another channel. This crosstalk of fluorescence signal can result in incorrect data unless a correction is made by using a Color Compensation File. Color compensation is used to subtract fluorescence crosstalk from a reporter dye into inappropriate channels outside of its dominant emission channel. 3. Kit components Tab.1: Reagents provided (Reagents provided in the kit are sufficient for 3 Color Compensation experiments) Kit Code Reagent Volume Lid color 1 Blank 1x 400 µl white 2 Dye 1 1x 400 µl green 3 Dye 2 1x 400 µl yellow 4 Dye 3 1x 400 µl orange 5 Dye 4 1x 400 µl red 2 RIDA GENE Color Compensation Kit I 11-10-31

4. Storage instructions Protect RIDA GENE Color Compensation Kit I from light and store at -20 C. RIDA GENE Color Compensation Kit I can be used until the expiration date printed on the label. After expiry the quality guarantee is no longer valid. Carefully thaw RIDA GENE Color Compensation Kit I reagents before use (e.g. in a refrigerator at 2-8 C). During Color Compensation preparation all the reagents should be stored cold in an appropriate way (2-8 C). 5. Additional equipment and materials LightCycler 480I, LightCycler 480II or LightCycler 480z (Roche) Real-time PCR consumables (plate, foil) Pipettes (0.5 20 µl, 20 200 µl, 100 1000 µl) Filter tips 6. Precautions for users This test must only be performed by laboratory personnel trained in molecular biology methods. Strictly follow the working instructions. When handling samples, wear disposable gloves. After finishing the test, wash your hands. Do not smoke, eat or drink in areas where samples or test reagents are being used. Do not use the kit after the expiration date. RIDA GENE Color Compensation Kit I 11-10-31 3

7. Protocol for creating a Color Compensation File on the Light Cycler 480 7.1 Preparation of the Color Compensation plate For a color compensation experiment it is necessary to pipette 5 reactions with 20 µl of each dye and also of the background (blank) into a microwell plate (s. Fig.1). Fig.1: Pipetting scheme for Color Compensation experiment Thaw, mix gently and centrifuge briefly the reagents before use. Keep reagents appropriately cold during working step (2-8 C). Tab.2: Preparation of the Color Compensation Kit Code Reagent Volume per reaction Pipette 20 µl into the following wells 1 Blank 20 µl B2, C2, D2, E2, F2 2 Dye 1 20 µl B4, C4, D4, E4, F4 3 Dye 2 20 µl B6, C6, D6, E6, F6 4 Dye 3 20 µl B8, C8, D8, E8, F8 5 Dye 4 20 µl B10, C10, D10, E10, F10 Cover the microwell plate with an optical sealing foil after pipetting the reagents. Start the real-time PCR according to LightCyler 480 Set-up. 4 RIDA GENE Color Compensation Kit I 11-10-31

7.2 LightCyler 480Set-up Note: Login as administrator to set up the detection format in the LightCyler 480 software. 1. After opening the LightCycler 480 software, it is necessary to click the Tools icon to program the detection format. RIDA GENE Color Compensation Kit I 11-10-31 5

2. The following window opens. Select Detection formats in the Tools window. Click the New button and set-up the detection format (see Tab.3). Save the detection format as R-Biopharm. Click the Close button to exit the Tools window. Tab.3: Detection Channels Set-up for LightCycler 480 Filter Combination LightCycler 480I LightCycler 480II LightCycler 480z 450 / 500 465 / 510 465 / 510 523 / 568 533 / 580 540 / 580 558 / 610 533 / 610 540 / 610 615 / 670 618 / 660 610 / 670 Note: Set the value for Quant Factor, Melt Factor as well as the Integration Time to 1. 6 RIDA GENE Color Compensation Kit I 11-10-31

3. After programming the detection format, click the New Experiment button. 4. The following window will open. Select detection format R-Biopharm and enter a reaction volume of 20 µl. 20 RIDA GENE Color Compensation Kit I 11-10-31 7

5. Program the LightCycler 480 according to the real-time PCR profile (see Tab.4). Click the Plus button to program the four protocol steps. Tab.4: LightCycler 480 real-time PCR profile Program Cycles / Analysis Mode Target [ C] Acquisition Mode Temperature targets Hold [hh:mm:ss] Ramp rate [ c/s] Initial Denat. 1 / none 95 none 00:00:30 4.4 Cycling TM-Analyse 5 / Quantification 1 / Color Compensation 95 none 00:00:15 4.4 60 single 00:00:30 2.2 95 none 00:00:01 4.4 50 none 00:00:30 2.2 70 continuous 0.14 (Acquisitions per C = 1) Cooling 1 / none 50 none 00:00:01 2.2 Note: Ensure the correct setting of the number of Analysis Mode and of the Cycles. 6. After completion of the programming the LightCycler experiment should look like the picture below. 8 RIDA GENE Color Compensation Kit I 11-10-31

7. To select the right PCR layout click the Subset Editor button. 8. Click on the Plus icon to create a new subset and enter a unique name for the layout (e.g. CC Layout). Press the Strg-key as well as the left mouse button simultaneously and mark all wells of the microwell plate with reagents. Click on the Apply button to finish the subset. The final screen should look like the screenshot below. RIDA GENE Color Compensation Kit I 11-10-31 9

9. Click the Sample Editor button. Select Color Comp from the Step 1: Select Workflow field. Then select the created subset (CC Layout) in the Step 2: Select Samples field. To finish the layout select in the Dominant Channel dialog field for the reagents ( Dye 1, Dye 2, Dye 3, Dye 4) the corresponding dominant channel (see Tab.5). Select for the samples with the reagent Blank the dominant channel Water. It is not necessary to enter a Sample Name. Tab. 5: Dominant Channel setting for reagents Dominant Channel Reagent LightCycler 480I LightCycler 480II LightCycler 480z Blank Water Water Water Dye 1 450 / 500 465 / 510 465 / 510 Dye 2 523 / 568 533 / 580 540 / 580 Dye 3 558 / 610 533 / 610 540 / 610 Dye 4 615 / 670 618 / 660 610 / 670 10 RIDA GENE Color Compensation Kit I 11-10-31

10. Place the PCR plate with the prepared reactions into the LightCyler 480. Click the Experiment icon and start the experiment by clicking the "Start Run" button in the experiment window. RIDA GENE Color Compensation Kit I 11-10-31 11

7.3 Evaluation and creation of a Color Compensation File After the experiment ends click the Analysis button to open the Create New Analysis dialog box and select Color Compensation. Select in the appearing dialog box the appropriate subset (e.g. CC Layout) and confirm your selection. Click the button Calculate in the analysis window to perform color compensation analysis. Click the Save CC Object button to save the Color Compensation file as R-Biopharm in the CCC folder. The created Color Compensation File can now be applied for other LightCycler 480 experiments. 12 RIDA GENE Color Compensation Kit I 11-10-31

To apply Color Compensation open the multiplex assay and click the Analysis button to select the appropriate filter combination. Select in Database from the Color Compensation drop-down menu and choose the stored Color Compensation file you want to apply to the experiment. Click the Color Compensation (Off) button, and select the appropriate Color Compensation File. The Color Compensation (Off) button switches to Color Compensation (On) to confirm that Color Compensation is active. The multiplex real-time PCR experiment can now be analyzed. Note: The Color Compensation File is specific for every LightCycler 480 instrument. A new Color Compensation File has to be created if the LightCyler 480 instrument is changed or after the optical system has been repaired. RIDA GENE Color Compensation Kit I 11-10-31 13