400A, 8, C, AND D TYPE KEY TELEPHONE UNITS IDENTIFICATION, INSTALLATION, CONNECTIONS, AND MAINTENANCE

Similar documents
400A, B, C, AND D TYPE KEY TELEPHONE UNITS IDENTIFICATION, INSTALLATION, CONNECTIONS, AND MAINTENANCE

SPEAKERPHONE SYSTEM-3-TYPE 630-TYPE TELEPHONE SETS CONNECTIONS AND MAINTENANCE

A. E. CO. TYPE 10A2 KEY TELEPHONE SYSTEM DESCRIPTION AND OPERATION PAGE

1A AND l Al KEY TELEPHONE SYSTEM

VOICE CONNECTING ARRANGEMENTS RDL AND ROM KS-19522, LIST 1 OR LIST 2 RECORDER COUPLER USED WITH KS-16765, LIST 1 ANNOUNCEMENT SET

REFERENCE 2750-TYPE TELEPHONE SETS

TONE COMMANDER SYSTEMS, INC l'oth Ave. N.E., Redmond, WA 980'2, U.s.A Telephone: (206) , Telex:

Introduction 1. Green status LED, controlled by output signal ST. Sounder, controlled by output signal Q6. Push switch on input D6

GRANT RF CONTROL CENTER INSTALLATION INSTRUCTIONS Always disconnect battery while servicing or modifying the electrical system of the vehicle.

IL591 SECTION D Rev /2011. Tek-SAFE NC150R Area of Rescue Assistance System. Operation, Installation and Service Manual

QUIZ BUZZER KIT TEACHING RESOURCES. Version 2.0 WHO ANSWERED FIRST? FIND OUT WITH THIS

Introduction 1. Digital inputs D6 and D7. Battery connects here (red wire to +V, black wire to 0V )

A Versatile New Intercom System

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Azatrax Model Railroad Track Signal Control - Single Track

N3ZI Digital Dial Manual For kit with Serial LCD Rev 3.04 Aug 2012

Summit Systems Sound Board Modification

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

N3ZI Digital Dial Manual For kit with Backlit LCD Rev 4.00 Jan 2013 PCB

P.S.C. No. 2- Telephone. FRONTIER TELEPHONE OF ROCHESTER, INC. Section 7 Original Page No. 1

Introduction and Definitions

Introduction 1. Green status LED, controlled by output signal ST

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

INSTALLATION INSTRUCTIONS FOR

Lab 7: Soldering - Traffic Light Controller ReadMeFirst

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Light Emitting Diodes (LEDs)

STX Stairs lighting controller.

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

Bill of Materials: Super Simple Water Level Control PART NO

COLOUR CHANGING USB LAMP KIT

TKEY-K16. Touch CW automatic electronic keyer. (No moving parts no contacts) Assembly manual. Last review: March 15, 2018

INTERFACE TERMINATION JTC USED WITH ATTESTED CUSTOMER-PROVIDED NON-POWERED CONFERENCING DEVICES

Build A Video Switcher

Build your own: Track Display

LED Spere Direct Control 30 ORDERCODE 41125

Atlas Drop In Decoder

Documentation VFD clock 8 a clock

Lab 7: Soldering - Traffic Light Controller ReadMeFirst

Sign Illuminating Ballasts

DLP200M 2 Relay Module for Heating and Cooling Plants

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Owner's Manual LIGHTING CONTROL CONSOLE TEATRONICS LIGHTING CONTROLS, INC. PROCON II Los Osos Valley Rd., Ste. G Los Osos, CA 93402

RISER AND DISTRIBUTION TERMINALS

DLP600M 6+1 Relay Module for Heating and Cooling Plants

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7

TABLE OF CONTENTS. PROGRAMMING THE VOLUME Ringer Volume Handset Volume Speakerphone/Intercom Volume Headset Volume...

16 Stage Bi-Directional LED Sequencer

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002

Ringing in multi-party telephone lines

8 PIN PIC PROGRAMMABLE BOARD (DEVELOPMENT BOARD & PROJECT BOARD)

Crimp & Cleave Termination Instructions for SEL ST Connectors

MONO AMPLIFIER KIT ESSENTIAL INFORMATION. Version 2.2 CREATE YOUR OWN SPEAKER DOCK WITH THIS

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

REGO Start&Go USER MANUAL

Atari PICO Composite Mod Board Installation Instructions:

Special Applications Modules

SECTION INTERCOMMUNICATIONS AND PROGRAM SYSTEMS

NX APPLICATION NOTE Led Guided Assembly Connector Pinning with Continuity

INSTRUCTION BOOK FOR. Lectern

r.link Video-inserter RL5-MIB-STD2

User Guide. Centrex Recording Interface

Description Diagram Page

ELECTRONIC GAME KIT TEACHING RESOURCES. Version 2.0 BUILD YOUR OWN MEMORY & REACTIONS

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

TECHNOLOGY WILL SAVE US: THE LUMIPHONE

CR-6 MIXER USER MANUAL ENGLISH. Order Code: MIXE01

Master Time Clock MTC Users Manual

VK-P10SE WARRANTY REGISTRATION FORM

4320 SS-25 Self-Strip Terminating Block

9216e. Installation and User Guide

( InfoSystems Translation )

r.link Video-inserter RL5-UCON7-500 Compatible with Fiat vehicles with Uconnect 7inch infotainment

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

APPLICATION NOTE # Monitoring DTMF Digits Transmitted by a Phone

Access Control Keypad for MK-DV, JB-DV

Mal-2 assembly guide v1.0

"Sophisticated Model Railroad Electronics"

Turnout Decoder TD Maxi. User Manual - version 0.1.6

Build Your Own Clone Relay Bypass Board Instructions

Low output Magnetic types R1 or R7 High output Magnetic types R2 Crystal types R13

INTRODUCTION INSTALLATION LIGHTNING RETARDING LOOPS. Figure 1. Relay Box Antenna Connections. Relay Box Cable Connections

Service Call: Fiber Optic Installation and Repair

16A Announcement System Description and Operating Procedures

THE NOVA PHONOMENA MUSICAL SURROUNDINGS PRESENTS: PHONOGRAPH PREAMPLIFIER OWNER S MANUAL. Musical Surroundings. status

DIY Guide - Building Franky v1.1, the SEGA Audio and Videocard for MSX

AUTOMATIC VIDEO LOSS A/B SWITCH

Station-User Guide For Single Line Telephones

Multi-Key v2.4 Multi-Function Amplifier Keying Interface

6A KEY TELEPHONE SYSTEM IDENTIFICATION AND INSTALLATION

Conettix D6600/D6100IPv6 Communications Receiver/Gateway Quick Start

MUK REAR PANEL ASSEMBLY ASSEMBLY INSTRUCTIONS

K9123, K9134, K9135 Remote Programming Instructions and Specifications

OPERATOR S MANUAL MICRO SEVEN, INC MODEL LS15-C1 TELEPHONE LINE SIMULATOR

CR Signals Price List (N Gauge & General) April 2010

EAGLE RE-1 CONTROLLER

15A Announcement System Description and Operating Procedures Common Systems

Transcription:

BELL SYSTEM PRACTCES Plant Series SECTON 51-220-400 ssue 2, September, 1966 AT&TCo Standard 400A,, C, AND D TYPE KEY TELEPHONE UNTS DENTFCATON, NSTALLATON, CONNECTONS, AND MANTENANCE 1. GENERAL 1.01 These key telephone units (KTUs) are designed for use as CO or PBX line circuit units in a 1A2 key telephone system. 1.02 This section is reissued to: Change title of section. Change resistor values in the 400D short time-out control circuit. nclude information concerning the Manufacture Discontinued (MD) 400A, 400B, and 400C KTU s. Since this reissue covers a general revision, arrows ordinarily used to indicate changes have been omitted. 2. DENTFCATON 2.01 The 400A(MD), 400B(MD), 400C(MD) and 400D KTU line circuits are mechanically and electrically interchangeable for use in 501-, 502-, 550-, and 551-type key service units, or 53- and 54-type panels, or a 259-type KTU. 2.02 Each KTU is an 1-contact plug-in unit with circuit components mounted on an epoxy-coated metal board interconnected by printed wiring on one side. The printed wiring for the 400D KTU is on both sides of the board. 2.03 The printed wiring is extended to the plugend of the board. The plug-end allows each unit to be mounted into a receptacle which has a matching contact arrangement. The plug-end is slotted in two places to orient for proper seating in the receptacle. 2.04 The KTUs provide the means for, or the control of, the following key system service and operational features: CO or PBX line pickup and hold. Flashing line lamp. Wink (or steady) hold lamp indications. ndividual line time-out with optional short or extended release time interval. Common audible signal on incoming calls. Talking circuit maintained during local power failure. Line circuit released by the switching equipment from a hold condition when the held party abandons the call ( 400D KTU only). 2.05 A plastic option block on each KTU permits a quick change of circuit options as required. See Table A for the various features provided by the options for each unit. 400A and 400B Key Telephone Units 2.06 The 400A and B KTUs (Fig. 1) are identical units with the exception of an additional diode (CR4) connected on the 400B KTU. This diode serves to prevent a system from falsely indicating an incoming call at a station following a momentary power interruption. 2.07 Each KTU is equipped with a U-shaped metal grip handle to assist in the insertion and removal of the KTU from its mounting receptacle. 400C Key Telephone Unit 2.0 The 400C KTU (Fig. 2) is designed specifically for use on CO or PBX lines subject to 60-cycle induction above 12 volts rms. n all other aspects, it is equivalent to the 400B unit. 2.09 The additional circuit components of this unit provide protection against false ringup due to longitudinal and transverse induced foreign potentials. American Telephone and Telegraph Company, 1966 Printed in U.S.A. Page 1

SECTON 51-220-400 TABLE A WRNG OPTONS FEATURE OPTON WRNG STRAP ON TERMNALS PROVDED BY 400A, B, 400D FACTORYt AND C KTU KTU Long Time Delay * ne Time-Out Short Time Delay z 1 to 2 Control Reduction of t 1 to 2 (1st lead) Short Time Delayt 3 (2nd lead) Visual Hold Lamp Wink y to 9 7 to 10 Signal Lamp Steady X 7 to 9 nterrupted Ring w 5 to 6 5 to Audible Steady Ring T 4 to 6 6 to Signaling Common, With v 3 to 6 4 to Relay Control Common, With s 5 to 6 5 to Matrix Control Yes Yes Yes * Long time delay is effective only when the Z option strap is removed. t When changing options, remove factory or existing option straps. t For 400D KTU only. See Table B. TABLE B RESSTANCE REQURED FOR DECREASNG SHORT TME-OUT NTERVAL ON 400D KTUt DESRED FRACTON OF MEGOHM RESSTOR EXSTNG TME-OUT RESSTOR* COLOR CODE 3/4 1.20 BROWN-RED-GREEN 2/3.75 VOLET-GREEN-YELLOW 1/2.39 ORANGE-WHTE-YELLOW 1/3.20 RED-BLACK-YELLOW 1/4.13 BROWN-ORANGE-YELLOW * KS-13490, List 1 or equivalent 1/2-watt resistor. t When the duration of the machine ringing is 1. 0 seconds, the time-out shall not be reduced more than 50% of the original time-out. Page 2

SS 2, SECTON 51-220-40( Fig. 1-400 Key Telephone Unit Fig. 2-400C Key Telephone Unit 2.10 The 400C KTU can be used in place of a 400A or when necessary. However, it should only be used when false ringup problems are being experienced with existing 400B KTUs. 400D Hey Telephone Unit 2.11 The 400D is functionally similar to the 400A, B, and C KTUs (Fig. 3). n addition to the option features of earlier KTUs, the combination option block and finger-grip handle of the 400D provide the means for field installation of a resistor to reduce the short time-out interval, if required. 2.12 The 400D KTU should be used as a maintenance replacement for the 400A, B, or C KTUs if the latter units fail to meet customer operating requirements. 3. NSTALLATON 3.01 f customer requirements are different from factory-furnished options indicated in Table A, these options should be changed on the KTU s before inserting into mounting receptacle. Bare 24-gauge wire should be used for strapping purposes. Use long-nose pliers for insertion or removal of strapping. 3.02 On early production models of 400B and C KTU s, the wire clips on the option blocks require that small (P-4F76) C-clamps be slipped over the clips to assure option strap retention and good circuit continuity (Fig. 4). 3.03 Later production models of the 400B and C and all 400D KTUs are equipped with flat stamped option block terminals that do not require use of C-clamps (Fig. 5 and 6). Page 3

SECTON 51-220-400 3.06 Shortening the time-out interval will reduce the length of time that the audible and flashing visual signals will continue after the call has been answered or abandoned externally to the key system. This continuance of signals creates distractions at the key station. te: Within the key system the audible and visual signals will stop immediately when the pickup key associated with the line being run is operated and the handset is removed from its mounting. 3.07 The factory-furnished Z option on the 400B and C KTU s provides a short time-out interval of 15 seconds after the first or second ring. Subsequent ringing within this 15-second interval resets the timing cycle to about 9 seconds. Modifying the units will reduce these intervals to about one-half their original periods. 3.0 To modify the 400B and C KTUs, connect a 1/2-watt, 100,000-ohm resistor electrically in parallel with the C5 capacitor. Physically, place, connect, and solder the resistor between points C and D as shown in Fig. 4. Fig. 3-4000 Key Telephone Unit 3.04 When inserting a KTU, grasp the unit by the handle, and with a vertical rocking motion use sufficient force to seat it fully in its receptacle. The plug-edge of each KTU is treated with a lubricant to assist in removal from or inserting in its mounting receptacle DO NOT WPE OFF LUBR CANT. 3.09 To reduce the short time-out interval (Z option) on the 400D KTU, proceed as follows: ( 1) Determine in seconds, the existing short time-out interval. Do this by dialing one line from another line at the same station, and counting the number of flashes on the called line lamp after hanging up on the calling line. Count one second for each flash of the lamp. (2) Select a resistor from Table B which will provide the time-out interval desired. The resistor selected will reduce the original timeout interval to the fractional value shown. Modifications To Reduce Short Time-Out nterval 3.05 When desired, the 400-type KTUs may be modified to provi9e a reduction of the short time-out interval (Z option). (3) Remove the Z option strapping. ( 4) Connect one lead of the selected resistor to terminal 3 on the option block. Connect the other lead to both terminals 1 and 2 (Fig. 6). Page 4

SS 2, SECTON 51-220-400 A B Fig. 4- Modification of 400 or C KTU Page 5

SECTON 51-220-400 X OPTON Y OPTON { FURNSH ED) W OPTON (FURNSHED) V OPT ON T OPTON Z OPT ON (FURNSHED) Fig. 5- Option Block, 400A, B, and C KTUs Page 6

SS 2, SECTON 51-220-400 Fig. 6 - Option Block - Handle, 4000 KTU Page 7

SECTON 51-220-400 ( 5) Check the modified time-out interval by repeating procedures outlined in ( 1). f a 400D KTU is being installed in equipment associated with a 235A or 236A KTU station line concentrator, the 235A and 236A KTUs must be modified as outlined in Section 51-310-405 to prevent a false-hold condition and possible permanent damage to the 400D KTU. The 235A and 236A KTU s do not require this modification when associated with equipment using the 400 and C KTUs. 4. CONNECTONS 4.01 The printed circuit wiring extends to the contacts of the KTUs, which are on one side of the circuit board along the plug-end (Fig. 1, 2, and 3). See Table C for lead designations. TABLE C TERMNAL ASSGNMENT FOR 400-TYPE KTU TERM. NO. 5. MANTENANCE LEAD DESG 1 RC 2 LW 3 4 10V± 5 ST 6 LG 7 LF L 9 R (CO) 10 105V± 11 RN 12 T (STA) 13 R (STA) 14 T (CO) 15 GRD B 16 A 17 BAT. B 1 5.01 When circuit trouble is encountered with a 400-type KTU, interchange it with one known to be working properly to determine whether the trouble is in the KTU itself or external to it. f the KTU is proved defective, replace with a good unit. te: Exercise care when inserting or removing the KTU to avoid damage to the printed wiring and other circuit components. 5.02 Line circuit failure can occur as a result of improper seating of the 400B or C KTU in its receptacle. On early production models of these units, the ends of the U -shaped handle may strike the receptacle and prevent the unit from being fully seated (point A on Fig. 4). Should this condition exist, bend the outer ends of the handle sufficiently to permit passage over the ends of the receptacle (point B on Fig. 4). After bending, the arms of the handle should be sufficiently pretensioned (squeezed together at the base of the U) to rest snugly against the ends of the option block. Later models have the option block insert extended at each end sufficiently to hold unbent U-handle arms in order to allow proper insertion in a mounting receptacle. Handles should not be flared on these KTUs (see Fig. 5). 5.03 The miniature relays used in the KTUs are factory adjusted. Field adjustments shall not be attempted. Do not remove the relay dust covers. 5.04 Operational sequence charts are shown in Fig. 7 and. 5.05 Refer to CD- and SD-69513-01 for detail description and schematic drawings. ft These units can be easily damaged by attempting field measurements without proper instruments. Such measurements should not be attempted. During periods when the local de supply is inoperative, outgoing calls may be originated at any time. ncoming calls to the KTUs operate connected line ringers in the usual manner, although common audible signals and all visual signals are inoperative. To avoid damage, use blister pack when transporting or storing a 400-type KTU. Over-pack when necessary. Page

SS 2, SECTON 51-220-400 400A,B 400C KTU OR KTU SC NCOMNG CALL CO OR PBX RNG SC4 STATON ANSWERS HELD CALL C FROM SC2 02 TRANSSTOR OFF CR ZENER DODE g~~g~gt:y~u2eb~~nrjsfu 1 ~N~~L6~~E CONDUCTS DUE TO NEGATVE BAS THROUGH CR A 01 TRANSSTOR B LAMPS STEADY NTERRUPTER * LAMP(S) FLASH RNGNG TO STATONS SC2 STATON ANSWERS NCOMNG CALL SC5 PERMANENT SGNAL DUE TO HOLD ON LNE LNE MOMENTARLY OPENED AT CO OR PBX ROH 01 TRANSSTOR OFF 0 TRANSSTOR CO OR PBX RNG TRPS B NTERRUPTER * B NTERRUPTER * LNE LAMPS CHANGE FROM FLASHNG TO STEADY 02 TRANSSTOR SC6 NCOMNG CALL S NOT ANSWERED, CALLNG PARTY HANGS UP TME-OUT NTERVAL STARTS ROH FROM SC2 SC3 STATON OPERATES RELEASES HOLD KEY HOLD KEY HOLD KEY A LAMP(S) WNK O TRA~~STOR HOLDS"C" B OPERATED NTERRUPTER * HOLD KEY OPENS TSR OF CO OR PBX LNE LAMPS +CO OR PBX RNGNG STOPS TME-OUT NTERVAL TABLE D C 5 CAPACTOR DSCHARGES 02 TRANSSTOR ON 01 TRANSSTOR OFF Bl NTERRUPTER * TABLE D TYPE OF RNGNG MACHNE TME-OUT NTERVAL SHORT OPTON @FURNSHED NTAL RNG 15 SEC SUBSEQUENT RNGS 9 SEC t MANUAL LONG @REMOVED 26 SEC 16 SEC t *UNLESS OPERATED BY ANOTHER LNE CRCUT. t PROVDED THE SUBSEQUENT RNG S APPLED WTHN THE PREVOUS TME-OUT NTERVAL. Fig. 7- Sequence Charts (SCl to SC6) Showing Operational Sequence of 400A, B, and C KTUs Page 9

SECTON S 1-220-400 SC NCOMNG CALL CO OR PBX RNG + l FOLLOWS RNGNG 0.5 SEC CT CAPACTOR (CHARGES TO BV BY NEGATVE HALF-CYCLES OF RNGNG) Q TRANSSTOR OFF Q2 TRANSSTOR ON Q3 TRANSSTOR ON NTERRUPTER* SC4 STATON ANSWERS HELD CALLS A(HOLDS C RELAY OPERATED) L Q TRANSSTOR ON Q2 TRANSSTOR OFF Q3 TRANSSTOR OFF NTERRUPTER* C FROM SC2 LAMP(S) FLASH RNGNG TO STATONS SC2 STATON ANSWERS NCOMNG CALLS A c CT CAPACTOR DSCHARGES Q TRANSSTOR ON Q2 TRANSSTOR OFF Q3 TRANSSTOR OFF NTERRUPTER* LNE LAMPS CHANGES FROM WNK TO STEADY LNE MOMENTARLY OPENED c SC5 RELEASE OF HOLDNG BRDGE BY CO OR PBX L Ql TRANSSTOR ON Q2 TRANSSTOR OFF Q3 TRANSSTOR OFF REVERSAL OF LNE BATTERY NTERRUPTER* c L Ql TRANSSTOR ON Q 2 TRANSSTOR OFF Q3 TRANSSTOR OFF l (Q S HELD ON BY FEEDBACK FROM 03 THROUGH RB) LAMPS L NTERRUPTER* LAMPS CO OR PBX RNGNG STOPS OPERATES HOLD KEY A SC3 STATON l (LNE CURRENT THROUGH TEL SET) Q TRANSSTOR OFF Q2 TRANSSTOR ON Q3 TRANSSTOR ON (HOLD C RELAY OPERATED) NTERRUPTER* LNE LAMPS CHANGES FROM FLASHNG TO STEADY RELEASES HOLD KEY HOLD KEY (STATON S DSCONNECTED FROM LNES) SC6 CALLNG PARTY ABANDONS UNANSWERED NCOMNG CALL- TME-OUT NTERVAL STARTS +CO OR PBX RNGNG STOPS TME-OUT NTERVAL TABLE E CT CAPACTOR DSCHARGES Q TRANSSTOR ON Q2 TRANSSTOR OFF Q 3 TRANSSTOR OFF NTERRUPTER* LAMPS LAMP(S) WNK HOLDNG PATH CREATED THROUGH L RELAY AND Rl RESSTOR * THE NTERRUPTER S A COMPONENTOFKEYSERVCE UNT. t PROVDED THE SUBSEQUENT RNG S APPLED WTHN THE PREVOUS TME-OUT NTERVAL. TYPE OF RNGNG TME-OUT NTERVAL OPTON NTAL RNG SUBSEQUENT RNG TABLE E MACHNE MANUAL SHORT LONG @FURNSHED @ REMOVED 13 SEC 35 SEC 12 SEC t 35 SEC t Fig. - Sequence Charts (SCl to SC6) Showing Operational Sequence of 4000 KTU Page 10 10 Pages