R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

Similar documents
R&S FSV-K76 TD-SCDMA BS (DL) Measurements Specifications

R&S FSV-K73 3G FDD UE (UL) Measurements incl. HSUPA Specifications

R&S FSW-K144 5G NR Measurement Application Specifications

EUTRA/LTE Downlink Specifications

R&S SMBV-Z1 Reference Frequency Converter Specifications

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

R&S FSV-K8 Bluetooth /EDR Measurement Application Specifications

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S FSQ-K91/K91n/K91ac WLAN a/b/g/j/n/ac Application Firmware Specifications

EUTRA/LTE Measurement Application Specifications

R&S ZN-Z154 Calibration Unit Specifications

R&S HF907DC SHF Downconverter Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S FPS-K18 Amplifier Measurements Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

R&S GU221 Filter Control Unit Specifications

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

R&S FSV-K40 Phase Noise Measurement Application Specifications

R&S ZN-ZTW Torque Wrench Specifications

R&S ZN-Z85 Switch Matrix Specifications

Test and Communications Antennas for the R&S TS8991 OTA Performance Test System Specifications

WLAN IEEE802.11a/b/g/j/p/n/ac/ax Measurement Application Specifications

R&S ZVA110 Vector Network Analyzer Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S AVG050 DVB Satellite Receiver Specifications

R&S FS-Z60/75/90/110 Harmonic Mixers for the R&S FSP/FSU/ FSQ/FSUP/FSV

R&S VSE Vector Signal Explorer Base Software Specifications

R&S FPC1000 Spectrum Analyzer Specifications

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

EUTRA/LTE and LTE-Advanced Signal Analysis Transmitter measurements on LTE signals

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

R&S SGS100A SGMA RF Source Specifications

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

R&S RT-Zxx High-Bandwidth Probes Specifications

R&S VSE Vector Signal Explorer Base Software Specifications

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

R&S RT-Zxx High-Voltage and Current Probes Specifications

R&S RSC Step Attenuator Where precise signal levels count

Multi-port calibration by using a two port calibration unit. Application Note. Products: R&S ZVT R&S ZNB

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

R&S EDS300 DME/Pulse Analyzer Specifications

Iterative Direct DPD White Paper

R&S SGU100A SGMA Upconverter Specifications

Pre-5G-NR Signal Generation and Analysis Application Note

R&S DST200 RF Diagnostic Chamber Specifications

R&S RT-Zxx Standard Probes Specifications

R&S CONTEST ITS Test cases and applications

R&S ZND Vector Network Analyzer Specifications

R&S SFD DOCSIS Signal Generator Signal generator for DOCSIS 3.1 downstream and upstream

Dynamic re-referencing Microvolt-level measurements with the R&S RTO oscilloscopes

EX-IQ-Box Digital Signal Interface Module Specifications

R&S DDF200M Digital Direction Finder Specifications

R&S EFL110/EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks

Product Brochure Version R&S TSML-CW Radio Network Analyzer Powerful scanner for CW applications

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

R&S CA210 Signal Analysis Software Offline analysis of recorded signals and wideband signal scenarios

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

R&S Spectrum Rider FPH Handheld spectrum analyzer

R&S ELEKTRA EMI Test Software Easy to use software for measuring electromagnetic disturbances

RF amplifier testing from wafer to design-in

Be ahead in 5G. Turn visions into reality.

R&S EDST300 TACAN/DME Station Tester Specifications

R&S TS-PMB Switch Matrix Module High-density, 90-channel, full matrix relay multiplexer module

R&S ZNBT Vector Network Analyzer Specifications

W-CDMA Base Station Transmitter Tests According to TS Rel. 10

R&S FK2900M HF Antenna Tuning Unit For stationary and shipboard applications

LabWindows/CVI, VXIpnp driver history for the R&S Spectrum Analyzers Driver Documentation

R&S MDS-21 Absorbing Clamp Measurement of disturbance power and screening effectiveness on cables

R&S FPS Signal and Spectrum Analyzer Compact and fast for automated tests

<EDGE Looped based BER and TX measurements using ARB files on the R&S CMW 500> Products: R&S CMW500 R&S CMW- KW200 R&S CMW- KM200. <Application Note>

R&S TSMx Radio Network Analyzers Powerful scanner family for mobile applications

R&S TS-ISC In-System Calibration Kit On-site calibration solution for R&S CompactTSVP

R&S ZNrun Automated Test Software PC-based server platform for automated VNA tests

DOCSIS 3.1 Full channel loading Maximizing data throughput

Concise NFC Demo Guide using R&S Test Equipment Application Note

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

R&S PSL3 Industrial Controller The powerful industrial controller

Stream Libraries For broadcasting T & M equipment from Rohde & Schwarz

PXI UMTS DL Measurement Suite Data Sheet

R&S SGMA Product Family Compact fast reliable

R&S SLx8000 Family of UHF/VHF Transmitters Efficient solutions for analog and digital broadcasting standards

This application note is a simple step-by-step guide that introduces a practical method to perform reliable small cell planning.

R&S BBL200 Broadband Amplifier Specifications

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

Your partner in testing the Internet of Things

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz

LabVIEW driver history for the R&S RTH Handheld Digital Oscilloscope Driver Documentation

R&S FSW Signal and Spectrum Analyzer Resolving Security Issues When Working in Secure Areas

R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas

Mastering Phase Noise Measurements (Part 3)

R&S NRP Power Sensor Family Specifications

Oscilloscopes for debugging automotive Ethernet networks

Fast. Accurate. USB-capable. Power sensors from Rohde & Schwarz

R&S SFC Compact Modulator and R&S SFC-U Compact USB Modulator Test signals for TV and audio broadcasting handy and economical

LabWindows/CVI, VXIpnp driver history for the R&S SGMA Vector RF Source

Transcription:

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications Test & Measurement Data Sheet 01.00

CONTENTS Definitions... 3 Specifications... 4 Frequency... 4 Level... 4 Signal acquisition... 4 Measurement parameters... 4 Result diagrams... 5 Measurement specification (nominal)... 6 Specifications for R&S FSW-K76... 6 Specifications for R&S FSW-K77... 7 Ordering information... 7 Specifications apply to the: R&S FSW-K76 3GPP TD-SCDMA BS Measurement Application R&S FSW-K77 3GPP TD-SCDMA UE Measurement Application They are based on the R&S FSW signal and spectrum analyzer data sheet specifications and have not been checked separately. They are not verified during instrument calibration. Measurement uncertainties are given as 95 % confidence intervals. The specified level measurement errors do not take into account systematic errors due to reduced signal to noise ratio (S/N). 2 Rohde & Schwarz R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications

Definitions General Product data applies under the following conditions: Three hours storage at ambient temperature followed by 30 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <,, >,, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable. Specifications without limits Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design. Typical data (typ.) Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean value. Nominal values (nom.) Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to typical data, a statistical evaluation does not take place and the parameter is not tested during production. Measured values (meas.) Characterize expected product performance by means of measurement results gained from individual samples. Uncertainties Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account environmental conditions, aging, wear and tear. Device settings and GUI parameters are designated with the format parameter: value. Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz. Rohde & Schwarz R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications 3

Specifications Frequency Frequency range RF input same as for R&S FSW 1 Level Level range RF input 60 dbm to +30 dbm 1 Signal acquisition Supported standards 3GPP TDD 1.28 Mcps option release 8 Capture length up to 283500 slots Sweep time spectrum mask, ACLR max. 16000 s, auto (adjacent channel leakage power ratio) Sweep count 1 to 32767 Trigger modes code domain analysis free run, external, IF power (only R&S FSW-K77) RF measurements free run, external, IF power 1, RF power 1, time, power sensor Time synchronization in code domain R&S FSW-K76 based on DwPTS analysis R&S FSW-K77 based on first detected uplink slot Measurement parameters Link mode R&S FSW-K76 downlink (DL) R&S FSW-K77 uplink (UL) Scrambling code 0 to 127 Maximum number of users (K cell ) 2, 4, 6, 8, 10, 12, 14, 16 Phase synchronization R&S FSW-K76 P-CCPCH midamble of selected slot R&S FSW-K77 code channel of selected slot midamble of selected slot Channel table search mode predefined and autosearch. The predefined channel table allows configuring the complete channel setup for the code domain analyzer. Normalize I/Q offset on/off Inactive channel power threshold channel table auto search 100 db to 0 db relative to total data power Maximum data modulation channel table auto search QPSK, 8PSK, 16QAM, 64QAM Spectrum emission mask standard in line with standard user defined the spectrum emission mask is measured in line with either the manual user setting or a user specified XML file. 1 Restricted IF overload, IF power trigger and auto level functionality depending on carrier frequency and bandwidth at carrier frequencies < 50 MHz. 4 Rohde & Schwarz R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications

Result diagrams Result summary general results chip rate error, trigger to frame results for selected slot data power, midamble power, averaged relative code domain error, number of active channels, carrier frequency error, I/Q imbalance, I/Q offset, ρ, composite EVM, peak code domain error results for selected channel absolute power, relative power, symbol EVM, data rate, modulation type Code domain power code domain power versus channel (relative to total power and absolute) Code domain error power code domain error power versus channel Peak code domain error peak code domain error power versus slot Channel power versus slot power versus slot for selected channel (relative to total power and absolute) Channel table numeric result table for all midambles and channels including the following readings: channel type, channel number, spreading factor, data rate, modulation type, absolute power, relative power, midamble shift, midamble to data power ratio Composite EVM EVM versus slot EVM versus symbol EVM versus symbol for selected channel and slot Power versus symbol power versus symbol for selected channel and slot Channel bit stream clear/write, bit stream for selected channel and slot Channel constellation clear/write, constellation diagram for selected channel and slot Composite constellation clear/write, constellation diagram for composite signal Output power, blank integrated signal power over channel bandwidth Adjacent channel power, multicarrier adjacent channel power, blank absolute and relative adjacent channel power Spectrum emission mask, blank spectrum mask limit check, peak list evaluation Occupied bandwidth, blank occupied bandwidth measured in frequency domain Power versus time transmit on/off time mask limit check, blank CCDF clear/write,, blank complementary cumulative distribution function Rohde & Schwarz R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications 5

Measurement specification (nominal) For 700 MHz < center frequency < 2.7 GHz and with external reference frequency applied. P total > 20 dbm. Specifications for R&S FSW-K76 Valid for 10 active DPCH, SF 16, modulation type QPSK. Code domain power Level uncertainty, total power P total > 20 dbm < 0.3 db Level uncertainty, channel power P total > 20 dbm, relative < 0.1 db Peak code domain error Measurement range AWGN channel 62 db to 25 db Residual PCDE < 62 db Composite EVM Measurement range AWGN channel 0.2 % to 20 % Residual EVM < 0.2 % Frequency error Measurement range sync to midamble ±14 khz Measurement uncertainty 3 Hz + reference frequency uncertainty (see R&S FSW frequency uncertainty) Occupied bandwidth Measurement uncertainty 99 % power bandwidth, span 4.8 MHz < 10 khz Spectrum emission mask Dynamic range (P total > 20 dbm ) 2 > 80 db Adjacent channel leakage ratio Dynamic range (P total > 20 dbm ) 3 with noise correction on > 79 db 2 3 The specified dynamic range is the ratio of the channel power to the power at an offset of 815 khz, measured with 30 khz integration bandwidth. The specified dynamic range is the ratio of the channel power to the power at an offset of 1.6 MHz, measured with 1.28 MHz integration bandwidth. 6 Rohde & Schwarz R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications

Specifications for R&S FSW-K77 Valid for 1 active DPCH, SF 16 in slot 1, modulation type QPSK Code domain power Level uncertainty, total power P total > 20 dbm < 0.3 db Level uncertainty, channel power P total > 20 dbm, relative < 0.1 db Peak code domain error Measurement range AWGN channel 58 db to 25 db Residual PCDE < 58 db Composite EVM Measurement range AWGN channel 0.2 % to 20 % Residual EVM < 0.2 % Frequency error Measurement range sync to midamble ±14 khz Measurement uncertainty 3 Hz + reference frequency uncertainty (see R&S FSW frequency uncertainty) Occupied bandwidth Measurement uncertainty 99 % power bandwidth, span 4.8 MHz < 14 khz Spectrum emission mask Dynamic range (P total > 20 dbm ) 4 > 80 db Adjacent channel leakage ratio Dynamic range (P total > 20 dbm ) 5 > 79 db Ordering information Designation Type Order No. 3GPP TD-SCDMA BS Measurement Application R&S FSW-K76 1313.1445.02 3GPP TD-SCDMA UE Measurement Application R&S FSW-K77 1313.1451.02 Signal and Spectrum Analyzer R&S FSW8 1312.8000.08 Signal and Spectrum Analyzer R&S FSW26 1312.8000.26 Recommended options and extras see the R&S FSW data sheet (PD 5214.5984.22) For product brochure, see PD 5214.5984.12 and www.rohde-schwarz.com 4 5 The specified dynamic range is the ratio of the channel power to the power at an offset of 815 khz, measured with 30 khz integration bandwidth. The specified dynamic range is the ratio of the channel power to the power at an offset of 1.6 MHz, measured with 1.28 MHz integration bandwidth. Rohde & Schwarz R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications 7

Service you can rely on Worldwide Local and personalized Customized and flexible Uncompromising quality Long-term dependability About Rohde & Schwarz Rohde & Schwarz is an independent group of companies specializing in electronics. It is a leading supplier of solutions in the fields of test and measurement, broadcasting, radiomonitoring and radiolocation, as well as secure communications. Established more than 75 years ago, Rohde & Schwarz has a global presence and a dedicated service network in over 70 countries. Company headquarters are in Munich, Germany. Environmental commitment Energy-efficient products Continuous improvement in environmental sustainability ISO 14001-certified environmental management system Certified Quality System ISO 9001 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com Regional contact Europe, Africa, Middle East +49 89 4129 12345 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia/Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China +86 800 810 8228/+86 400 650 5896 customersupport.china@rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners Printed in Germany (as) PD 3606.7724.22 Version 01.00 October 2012 R&S FSW-K76/-K77 Subject to change 2012 Rohde & Schwarz GmbH & Co. KG 81671 München, Germany 3606772422