MASTER DIALOG ERM 8-20kVA three/single phase ERT kVA three/three phase

Similar documents
Chloride EDP Series Three-Phase UPS ( kva): The EDP Series UPS is designed

FN Series Scalable N+1 UPS 3kVA to 40kVA Tower

CONSUMER UPS SINGLE PHASE UPS UP TO 3000 VA THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

DA E: Series of Narrowband or Wideband Distribution Amplifiers

Programmable Power Supplies 188 W 384 W R&S HMP Series

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Typical applications:

Truck router (3Gbps/HD/SD/ASI)

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

X-Band Redundant LNB Systems

DA : Series of Narrowband or Wideband Distribution Amplifiers

Ku-Band Redundant LNB Systems

C-Band Redundant LNB Systems

Henkel Installation Handbook LINEGUARD 2001

Model KBF 115 Constant climate chambers with large temperature / humidity range

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

Rack mounted telephone- and leased line modem for industrial applications

SAPLING WIRED SYSTEM

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

IRT Eurocard. Type RWA RF Distribution Amplifier for 70 MHz IF signals

INVERTERS UPS FREQUENCY CONVERTERS. Land Sea Air MILITARY COMMERCIAL INDUSTRIAL AS Certificate No: US

Product Range Power Supplies

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

SOLID STATE UNINTERRUPTIBLE POWER SUPPLY

INSTALLATION & USER GUIDE

LAUREL ELECTRONICS, INC.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

multi-function meters

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Model KBF 1020 Constant climate chambers with large temperature / humidity range

I/A Series Hardware Fiber Optic LAN Converter

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Synthesized Block Up- and Downconverter Indoor / Outdoor

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

LED Driver Linear / area fixed output

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

1/3 RACK-MOUNTED BLOCK CONVERTERS

LED Driver Compact fixed output

HD-CM HORIZON DIGITAL CABLE METER

ABB i-bus EIB Universal dimmer 6155 EB for Installation

Process Transmitter RMA 422

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

SCALE & WEIGHT DISPLAYS

ED5229GT-E Series. Page 1 of 8

Modular Power System acc. VG MoFess Module for Military Ground Vehicles

Satellite Up- and Downconverter Indoor / Outdoor

ALPAN W Compact DTV Transmitters 3-4U 19 HE DIGITAL ANALOG

Model KT 53 Cooling incubators with thermoelectric cooling

Indoor Linear 80W Driver SI-C215280N2KR

FULLY STATIC electronic FREQUENCY CONVERTER Adjustable output voltage Static electronic voltage stabilizer G M M G T M G T T

LED Driver Compact fixed output

Q516 HIGH RES AUDIO DELAY ORDERING OPTIONS SUPPORT OPTIONS MANAGEMENT AND CONTROL HIGH PRECISION AUDIO DELAY FOR MICRO SECOND ACCURACY

Model KT 115 Cooling incubators with thermoelectric cooling

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

AMU2-2MHD+ Audio monitoring Unit

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

R-1580A Microwave Downconverter. Product Brochure

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

Stud Welding Equipment


INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

ED5229GT-E/GTRE Series

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

AVMU2-BHD+/3G Audio monitoring Unit

Innovation in Magnetic Field Measuring Instruments. Magnetometer Power Supplies

Model KBF P 240 Humidity test chambers with ICH-compliant light source

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

L-Band Block Up- and Downconverter Indoor / Outdoor

Engineered to meet your needs T he oldest name in stud welding,

DIGITAL SPEAKER MANAGEMENT UK

55 (54.6 viewable) Full HD Direct-lit LED Commercial Display CDE5502 Direct LED backlight technology for superior color performance

LED Driver Compact dimming

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

AF-300 E11 Adjustable Frequency Drive

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Durable and Reliable Design for 24/7 Use. Overview. Narrow Bezel Optimized for Video Walls. 42 Narrow bezel commercial LED display

Various regulation agencies require us to bring the following information to your attention. Please read carefully.

SECTION INTERCOMMUNICATIONS AND PROGRAM SYSTEMS

Innovation in Magnetic Field Measuring Instruments. Magnetometer Power Supplies

LT-82 Stationary IR Transmitter

10MHz Source/Inserter

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. STV-4101: V 30A (18) IEC C13 + (6) IEC C19 Outlets

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Clamp 200 A AC/DC (+ V AC/DC + Ω)

P XGA TFT Monitor. User s Manual

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Instruction Manual Model BlockUpconverter

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

HDO750 OPTICAL AMPLIFIER FAMILY

ex 800 Series ematrix System

Transcription:

MASTER DIALOG ERM 8-20kVA three/single phase ERT 10-160kVA three/three phase The Master Dialog range uses advanced double-conversion on-line (VFI) technology with a transformer isolated inverter output to support loads up to 160kVA (1MVA for the maximum parallel system). ERM models provide a single output from a three phase input. ERT models provide a three phase output. The load is powered continuously by the inverter with an EMI filtered, stabilised and regulated sinewave supply. The Eco-Mode (100kVA upwards) helps to improve operating efficiencies (up to 98%) for security applications such as emergency lighting. The UPS is an outstanding long runtime solution for critical voice and data processing applications. Runtimes from several minutes to many hours can be achieved using matching battery extension packs (BEPs) or local standby generators. Master Dialog is supplied with the PowerShield 2 UPS management software package. W x D x H 555 x 720 x 1200 mm W x D x H 800 x 740 x 1400 mm W x D x H 1070 x 740 x 1400 mm 1 Language selection 2 Input/Output measurements 3 Controls/Settings/Customisation options 4 Event log 9 10 11 12 Digital display Bypass ON/Manual Bypass Inverter ON/Overload Mains supply present 5 6 7 8 Alarm reset Time/Date Scroll down Scroll up 13 On batteries/end of discharge pre-alarm

FEATURES Advanced double-conversion on-line (VFI) technology (EN50091-3) with EMI filters and a transformer isolated inverter output High reliability: microprocessor controlled static and manual bypass facility IGBT based power electronics Extremely high short circuit current (2.8In) Parallel and redundant (N+1) operation (up to 6 units) Dual input option High level diagnostics: states, modes, measurements and alarms Built-in front panel LCD with scroll function, RS232 and signal contact ports Low power consumption and maintenance costs (MTTR 30minutes) Low cost and simplified installation including; calibration of the output voltage from the front panel keypad to allow for voltage drop down long cable runs Ability to place the UPS on any distribution network (neutral not required on rectifier input) using input isolation transformers Separation of the rectifier/bypass power supplies Powering from different sources without Galvanic isolation Built-in battery test facility (automatic and manual), temperature compensating charger and deep battery discharge protection Cold-start facility to allow the UPS to power up without a mains supply for security applications such as emergency lighting APPLICATIONS Local Area Networks (LANs) Servers Data centres Internet centres (ISP/ASP/POP) Industrial PLCs Medical appliances Telecommunications devices Emergency applications (lights/alarms) ADVANCED COMMUNICATION Advanced, multi-platform communication, for all operating systems and network environments: PowerShield 2 monitoring and control software included, with SNMP agent, for Windows 95, 98, 2000, Me, NT 4.0, Novell operating systems. The UPS is supplied with a PC Communications cable for direct connection to a PC (Plug and Play) RS232 serial port Volt Free Signals EPO (Emergency Power Off) Contact for UPS shutdown using a remote panic button Input contact for remote bypass operation Digital or LED-based remote control panel

single phase output models ERM MODEL 8KVA 10KVA 15KVA 20KVA RECTIFIER INPUT Rated power [kva] 8 10 15 20 Rated voltage Voltage range ±20% Frequency range 45-65Hz Soft start 0-100% in 10s RECTIFIER OUTPUT Nominal battery voltage 384Vdc Maintenance voltage Temperature dependant [-0.5V x C] Ripple < 1% INVERTER OUTPUT Rated power [kva/kw] 8/6.4 10/8 15/12 20/16 Rated voltage [V] 230 single-phase Rated current [A] 35 43 65 87 Regulation of the output voltage 200-244Vac phase/neutral (from control panel) Crest factor 3:1 Waveform Sinewave Static stability ±1% Dynamic stability ±5% in 5ms 50/60Hz (auto sensing or selectable) Frequency stability (mains supply failure ) ±0.05 % Frequency stability (mains supply present) ±2% (adjustable ± 1%/±5% from control panel) Overload 125/150/200% of the rated current for 10 /1 /7 s Inverter efficiency at rated load 92 93 93 93 BATTERY (Maintenance-free sealed lead-acid) Typical recharge time 8h BYPASS Rated current [A] 35 43 65 87 Rated voltage [V] 230 single-phase Permitted voltage range ±15% (adjustable ±10%, ±25% from front panel) 50/60Hz (auto sensing) Permitted frequency range ±2% (adjustable ±1%, ±5% from front panel) Overload capacity In x 10ms 18 14 12 14 Standard features Back Feed protection; separate bypass line INSTALLATION INFORMATION Efficiency 91 92 92 92 Compliance EN50091-1-1, EMC EN50091-2 Lev. A EC Directives 73/23-93/68-89/336 Air flow (m3/h) (for installations in a closed environment) 310 372 558 744 Remote signaling Volt-free contacts (mains power failure, UPS on bypass, end of discharge pre-alarm... output 12Vdc 80mA) Remote controls EPO and bypass Computer interface RS232/C Operating temperature 0-40 C Maximum relative humidity non condensing 95% Noise (dba) 48-54 48-54 53-60 53-60 Enclosure protection rating IP20 Colour Light grey RAL 7035 Rectifier maximum input current [A] 15 18 27 36 Bypass input current [A] 36 45 68 91 Differential input current* 100mA VALUE OF THE OUTPUT PROTECTION (FOR SELECTIVITY)** Normal fuses (GI) In (Rated current) / 5.5 Normal switches (Curve C) In (Rated current) / 5.5 Extra fast fuses In (Rated current) / 1.6 Cable infeed Bottom/rear * This value must be added to the differential current of the equipment. Special applications on request ** Complying with these values, the UPS will be able to provide the power required to interrupt the output protection if a short-circuit occurs, without switching the load to the mains supply

Model No Power Back-up Dimensions Weight at full load (W x D x H) mm Kg ERM8KVA31/01 8kVA/6k4W 0m 555 x 720 x 1200 190 ERM8KVA31/02 10m 555 x 720 x 1200 280 ERM8KVA31/03 20m 555 x 720 x 1200 311 ERM8KVA31/05 35m 555 x 720 x 1200 401 ERM8KVA31/04 50m 555 x 720 x 1200 432 ERM10KVA31/01 10kVA/8kW 0m 555 x 720 x 1200 200 ERM10KVA31/02 6m 555 x 720 x 1200 290 ERM10KVA31/03 15m 555 x 720 x 1200 321 ERM10KVA31/05 30m 555 x 720 x 1200 411 ERM10KVA31/04 40m 555 x 720 x 1200 442 ERM15KVA31/01 15kVA/12kW 0m 555 x 720 x 1200 220 ERM15KVA31/02 10m 555 x 720 x 1200 341 ERM15KVA31/04 15m 555 x 720 x 1200 431 ERM15KVA31/03 20m 555 x 720 x 1200 462 ERM20KVA31/01 20kVA/16kW 0m 555 x 720 x 1200 240 ERM20KVA31/02 10m 555 x 720 x 1200 451 ERM20KVA31/03 15m 555 x 720 x 1200 482 TYPICAL BATTERY EXTENSION PACKS UPS Back-up Battery Extension Packs Qty Dimensions Weight Model No at full load Model No (W x D x H) mm Kg ERM8KVA31/01 1h5 BEP384038AB/01 1 555 x 720 x 1200 537 2h BEP384065AC/01 1 860 x 720 x 1200 861 ERM10KVA31/01 1h5 BEP384038AB/01 1 555 x 720 x 1200 537 2h10 BEP384065AC/01 1 860 x 720 x 1200 861 ERM15KVA31/01 40m BEP384038AB/01 1 555 x 720 x 1200 537 1h15 BEP384065AC/01 1 860 x 720 x 1200 861 ERM20KVA31/01 30m BEP384038AB/01 1 555 x 720 1200 537 55m BEP384065AC/01 1 860 x 720 x 1200 861 OPTIONS 10 year design life, 5 year warranty batteries USB signal converter SNMP network adaptor Remote status panel with LCD or LEDs Wall mounted maintenance bypass with manual and automatic transfer Isolation (Galvanic) pack for the bypass supply Harmonic filter pack (THD < 5%) Battery cabinets, cladded racks, internal trays and cables Parallel/redundant operation cards PowerShield2 UPS monitoring and control software, and SNMP solutions Service and maintenance plan

three phase output models ERT MODEL 10KVA 15KVA 20KVA 30KVA 40KVA RECTIFIER INPUT Rated power [kva] 10 15 20 30 40 Rated voltage Voltage range ±20% 50/60Hz auto-sensing Frequency range 45-65Hz Soft start 0-100% in 10s RECTIFIER OUTPUT Nominal battery voltage 384Vdc Maintenance voltage Temperature dependant [-0.5V x C] Ripple < 1% INVERTER OUTPUT Rated power [kva/kw] 10/8 15/12 20/16 30/24 40/32 Number of phases 3+N Rated voltage [V] 400 Rated current [A] 14 22 29 43 58 Regulation of the output voltage Adjustable from 348Vac to 424Vac (from control panel) Crest factor 3:1 Waveform Sinewave Static stability ±1% Dynamic stability ±5% in 5ms 50/60Hz (auto-sensing or selectable) Frequency stability (Mains supply failure) ±0.05% Frequency stability (Mains supply present) ±2% (adjustable ±1% / ±5% from control panel) Overload 25/150/200% of the rated current per 10 /1 /7 s Efficiency of the inverter at rated load 91 91 92 92 93 BATTERY (Maintenance-free sealed lead-acid) Typical recharge time 8h BYPASS Rated current [A] 14 22 29 43 58 Rated voltage [V] Voltage range ±15% (adjustable ±10%, ±25% from control panel) 50/60Hz ( auto-sensing) Permitted frequency range ±2% (adjustable ±1%, ±5% from control panel) Overload capacity In x 10ms 14 15 14 15 14 Standard features Back Feed protection; separate bypass line INSTALLATION INFORMATION Efficiency 90 90 91 91 92 Compliance EN50091-1-1, EMC EN50091-2 Lev. A Directives 73/23-93/68-89/336 EEC Remote signalling Volt-freecontacts (mains p failure, UPS on bypass, end of discharge pre-alarm... - output 12Vdc 80mA) Remote controls EPO and remote bypass Standard interface RS232/C Operating temperature 0-40 C Maximum relative humidity non condensing 95% Noise (dba) 48-54 48-54 53-60 53-60 53-60 Enclosure protection rating IP20 Colour Light grey RAL 7035 Air flow (m3/h) (for installations in a closed environment) 496 682 868 1240 1488 Maximum input current rectifier [A] 18 28 37 55 72 Bypass input current [A] 15 23 30 45 61 Differential input current* 100mA VALUE OF THE OUTPUT PROTECTION (FOR SELECTIVITY)** Normal fuses (GI) In (Rated current) / 5.5 Normal switches (Curve C) In (Rated current) / 5.5 Fast-blow fuses In (Rated current) / 1.6 Cable infeed bottom / rear * This value must be added to the differential current of the equipment. Special applications on request ** Complying with these values, the UPS will be able to provide the power required to interrupt the output protection if a short-circuit occurs, without switching the load to the mains supply

Model No Power Back-up Dimensions Weight at full load (W x D x H) mm Kg ERT10KVA33/01 10kVA/8kW 0m 555 x 720 x 1200 210 ERT10KVA33/02 6m 555 x 720 x 1200 300 ERT10KVA33/03 15m 555 x 720 x 1200 331 ERT10KVA33/05 30m 555 x 720 x 1200 421 ERT10KVA33/04 40m 555 x 720 x 1200 452 ERT15KVA33/01 15kVA/12kW 0m 555 x 720 x 1200 220 ERT15KVA33/02 10m 555 x 720 x 1200 341 ERT15KVA33/04 15m 555 x 720 x 1200 431 ERT15KVA33/03 20m 555 x 720 x 1200 462 ERT20KVA33/01 20kVA/16kW 0m 555 x 720 x 1200 240 ERT20KVA33/02 10m 555 x 720 x 1200 451 ERT20KVA33/03 15m 555 x 720 x 1200 482 ERT30KVA33/01 30kVA/24kW 0m 555 x 720 x 1200 285 ERT40KVA33/01 40kVA/32kW 0m 555 x 720 x 1200 330 TYPICAL BATTERY EXTENSION PACKS UPS Back-up Battery Extension Packs Qty Dimensions Weight Model No at full load Model No (W x D x H) mm Kg ERT10KVA33/01 1h5 BEP384038AB/01 1 555 x 720 x 1200 537 2h10 BEP384038AB/01 2 555 x 720 x 1200 537 ERT15KVA33/01 40m BEP384038AB/01 1 555 x 720 x 1200 537 1h15 BEP384065AC/01 1 860 x 720 x 1200 861 ERT20KVA33/01 30m BEP384038AB/01 1 555 x 720 x 1200 537 55m BEP384065AC/01 1 860 x 720 x 1200 861 ERT30KVA33/01 8m BEP384024AA/01 1 270 x 720 x 1200 302 15m BEP384038AB/01 1 555 x 720 x 1200 537 32m BEP384065AC/01 1 860 x 720 x 1200 861 40m BEP384038AB/01 2 555 x 720 x 1200 537 1h BEP384038AB/01 1 555 x 720 x 1200 537 - BEP384065AC/01 1 860 x 720 x 1200 861 ERT40KVA33/01 10m BEP384038AB/01 1 555 x 720 x 1200 537 25m BEP384065AC/01 1 860 x 720 x 1200 861 30m BEP384038AB/01 2 555 x 720 x 1200 537 55m BEP384065AC/01 2 860 x 720 x 1200 861 OPTIONS 10 year design life, 5 year warranty batteries SNMP network adaptor Remote status panel with LCD or LEDs Wall mounted maintenance bypass with manual and automatic transfer Isolation (Galvanic) pack for the bypass supply Harmonic filter pack (THD < 5%) Battery cabinets, cladded racks, internal trays and cables Parallel/redundant operation cards PowerShield 2 UPS monitoring and control software, and SNMP solutions Service and maintenance plans

three phase output models ERT MODEL 60KVA 80KVA RECTIFIER INPUT Rated power [kva] 60 80 Rated voltage Voltage range ±20% 50/60Hz auto-sensing Frequency range 45-65Hz Soft start 0-100% in 10s RECTIFIER OUTPUT Nominal battery voltage 384Vdc Maintenance voltage Temperature dependant [-0.5V x C] Ripple <1% INVERTER OUTPUT Rated power [kva/kw] 60/48 80/64 Number of phases 3+N Rated voltage [V] 400 Rated current [A] 87 115 Regulation of the output voltage Adjustable from 348Vac to 424Vac (from control panel) Crest factor 3:1 Waveform Sinewave Static stability ± 1% Dynamic stability ±5% in 5ms 50/60Hz (auto-sensing or selectable) Frequency stability (mains supply failure) ±0.05% Frequency stability (mains supply present) ±2% (adjustable ± 1% / ±5% from control panel) Overload 125/150/200 % of the rated current per 10 /1 /7 s Efficiency of the inverter at rated load 93 93 BATTERY (Maintenance-free sealed lead-acid) Typical recharge time 8h BYPASS Rated current [A] 87 115 Rated voltage [V] Permitted voltage range ±15% (adjustable ±10%, ±25% from control panel) 50/60Hz (auto-sensing) Permitted frequency range ±2% (adjustable ± 1%, ±5% from control panel) Overload capacity In x 10ms 12 11 Standard features Back Feed protection; separate bypass line INSTALLATION INFORMATION Efficiency 92 92 Compliance EN50091-1-1, EMC EN50091-2 Lev. A Directives 73/23-93/68-89/336 EEC Remote signalling V0lt-free contacts (mains supply failure, UPS on bypass, end of discharge pre-alarm... - output 12Vdc 80mA) Remote controls EPO and remote bypass Standard interface RS232/C Operating temperature 0-40 C Maximum relative humidity non condensing 95% Noise (dba) 53-62 Enclosure protection rating IP20 Colour Light grey RAL 7035 Air flow (m3/h) (for installations in a closed environment) 2232 2960 Maximum input current rectifier [A] 100 125 Bypass input current [A] 91 121 Differential input current* 100mA VALUE OF THE OUTPUT PROTECTION (FOR SELECTIVITY)** Normal fuses (GI) In (Rated current) / 5.5 Normal switches (Curve C) In (Rated current) / 5.5 Fast-blow fuses In (Rated current) / 1.6 Cable infeed bottom/rear * This value must be added to the differential current of the equipment. Special applications on request ** Complying with these values, the UPS will be able to provide the power required to interrupt the output protection if a short-circuit occurs, without switching the load to the mains supply

Model No Power Back-up Dimensions Weight at full load (W x D x H) mm Kg ERT60KVA33/01 60kVA/48kW 0m 800 x 740 x 1400 450 ERT80KVA33/01 80kVA/64kW 0m 800 x 740 x 1400 555 TYPICAL BATTERY EXTENSION PACKS UPS Back-up Battery Extension Packs Qty Dimensions Weight Model No at full load Model No (W x D x H) mm Kg ERT60KVA33/01 6m BEP384038AD/01 1 555 x 740 x 1400 552 12m BEP384065AE/01 1 860 x 740 x 1400 876 18m BEP384100AE/01 1 860 x 740 x 1400 1000 36m BEP384065AE/01 2 860 x 740 x 1400 876 ERT80KVA33/01 5m BEP384038AD/01 1 555 x 740 x 1400 552 8m BEP384065AE/01 1 860 x 740 x 1400 876 14m BEP384100AE/01 1 860 x 740 x 1400 1000 24m BEP384065AE/01 2 860 x 740 x 1400 876 OPTIONS 10 year design life, 5 year warranty batteries USB signal converter SNMP network adaptor Remote status panel with LCD or LEDs Wall mounted maintenance bypass with manual and automatic transfer Isolation (Galvanic) pack for the bypass supply Harmonic filter pack (THD < 5%) Battery cabinets, cladded racks, internal trays and cables Parallel/redundant operation cards PowerShield 2 UPS monitoring and control software, and SNMP solutions Service and maintenance plans

three phase output models ERT MODEL 100KVA 120KVA 160KVA RECTIFIER INPUT Rated power [kva] 100 120 160 Rated voltage Voltage range ±20% 50/60Hz auto-sensing Frequency range 45-65Hz Soft start 0-100% in 10s RECTIFIER OUTPUT Nominal battery voltage 432Vdc 480Vdc Maintenance voltage Temperature dependant [-0.5V x C] Ripple < 1% INVERTER OUTPUT Rated power [kva/kw] 100/80 120/96 160/128 Number of phases 3+N Rated voltage [V] 400 Rated current [A] 145 174 232 Regulation of the output voltage Adjustable from 348Vac to 424Vac (from control panel) Crest factor 3:1 Waveform Sinewave Static stability ±1% Dynamic stability ±5% in 5ms 50/60Hz (auto-sensing or selectable) Frequency stability (mains supply failure) ±0.05% Frequency stability (mains supply present) ±2% (adjustable ±1% / ±5% from control panel) Overload 125/150/200% rated current for 10 /1 /7 s Efficiency of the inverter at rated load 94 94 95 BATTERY (Maintenance-free sealed lead-acid) Typical recharge time 8h BYPASS Rated current [A] 145 174 232 Rated voltage [V] Permitted voltage range ±15% (adjustable ±10%, ±25% from control panel) 50/60Hz (auto-sensing) Permitted frequency range ±2% (adjustable ±1%, ±5% from control panel) Overload capacity In x 10ms 12 10 10 Standard features Back Feed protection; separate bypass line INSTALLATION INFORMATION Efficiency 93 93 93 Compliance EN50091-1-1, EMC EN50091-2 Lev. A Directives 73/23-93/68-89/336 EEC Remote signalling Volt-free contacts (mains power failure, UPS on bypass, end of discharge pre-alarm... - output 12Vdc 80mA) Remote controls EPO and remote bypass Standard interface RS232/C Operating temperature 0-40 C Maximum relative humidity non condensing 95% Noise (dba) 54-62 Enclosure protection rating IP20 Colour Light grey RAL 7035 Air flow (m3/h) (for installations in a closed environment) 3700 4400 5800 Maximum input current rectifier [A] 160 190 250 Bypass input current [A] 152 182 243 Differential input current* 100mA VALUE OF THE OUTPUT PROTECTION (FOR SELECTIVITY)** Normal fuses (GI) In (Rated current) / 5.5 Normal switches (Curve C) In (Rated current) / 5.5 Fast-blow fuses In (Rated current) / 1.6 Cable infeed bottom / rear * This value must be added to the differential current of the equipment. Special applications on request ** Complying with these values, the UPS will be able to provide the power required to interrupt the output protection if a short-circuit occurs, without switching the load to the mains supply

Model No Power Back-up Dimensions Weight at full load (W x D x H) mm Kg ERT100KVA33/01 100kVA/80kW 0m 1070 x 740 x 1400 650 ERT120KVA33/01 120kVA/96kW 0m 1070 x 740 x 1400 730 ERT160KVA33/01 160kVA/128kW 0m 1070 x 740 x 1400 900 TYPICAL BATTERY EXTENSION PACKS UPS Back-up Battery Extension Packs Qty Dimensions Weight Model No at full load Model No (W x D x H) mm Kg ERT100KVA33/01 7m BEP432065AG/01 1 860 x 740 x 1800 1017 11m BEP432100AG/01 1 860 x 740 x 1800 1280 20m BEP432065AG/01 2 860 x 740 x 1800 1017 30m BEP432100AG/01 2 860 x 740 x 1800 1280 ERT120KVA33/01 5m BEP480065AG/01 1 860 x 740 x 1800 1108 10m BEP480100AG/01 1 860 x 740 x 1800 1560 15m BEP480065AG/01 2 860 x 740 x 1800 1108 20m BEP480100AG/01 2 860 x 740 x 1800 1560 ERT160KVA33/01 8m BEP480100AG/01 1 860 x 740 x 1800 1560 12m BEP480065AG/01 2 860 x 740 x 1800 1108 17m BEP480100AG/01 2 860 x 740 x 1800 1560 OPTIONS 10 year design life, 5 year warranty batteries USB signal converter SNMP network adaptor Remote status panel with LCD or LEDs Wall mounted maintenance bypass with manual and automatic transfer Isolation (Galvanic) pack for the bypass supply Harmonic filter pack (THD < 5%) Battery cabinets, cladded racks, internal trays and cables Parallel/redundant operation cards PowerShield 2 UPS monitoring and control software, and SNMP solutions Service and maintenance plans Riello Galatrek Ltd - Unit 68 Clywedog Road North, Wrexham Industrial Estate, Wrexham LL13 9XN Telephone: 01978 729 297 - Sales (UK): 0800 269 394 - Service: 01978 729 281 - Fax: 01978 729 290/91 Website: www.riello-ups.co.uk - Email: riello@riello-ups.co.uk Registered in England & Wales No. 4582458