Integration of the Zetasizer µv and OmniFACE into an SEC system

Similar documents
Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

Real-time ph and Conductivity Data Acquisition with the ACQUITY UPLC H-Class Bio System, Auto Blend Plus, and the GE Healthcare Monitor ph/c-900

P-2 Installing the monitor (continued) Carry out as necessary

Mortara X-Scribe Tango+ Interface Notes

ICS-3000 System Installation Qualification

DM1624, DM1612, DM812

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

BMW12N-H NTV-KIT791. Kit Contents. BMW12N-H Interface. Interface Power Harness

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

DX-10 tm Digital Interface User s Guide

BMW12N-DYNAMIC KIT NTV-KIT717

EVD-L04/100A1-960, EVD-L08/200A1-960 and. EVD-L16/400A1-960 DVRs. Quick Operation Guide

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

Installation Note. Agilent 89441A Option AYC Installation Kit

Auxiliary states devices

ipump 622 Streaming Media Decoder Installation Quick Start Guide

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Video Server SED-2100R/S. Quick Installation Guide

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

Quick Operation Guide of LTN7700/7600 Series NVR

Control Unit CU 2.1 User Manual V6850A HPLC

DINOX&Digital&Video&Recorder&

Digital Video Recorder

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

GWL/ Power Group Technology Solutions Stay Powered for the Future

GFT Channel Digital Delay Generator

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

Artistic Licence Engineering Ltd Firmware Version V3.03 Manual Revision V1-9

Instrument Control and Data Acquisition with Chromeleon

Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

EEG A1452 SCTE-104 Inserter Frame Card

FTC AGL System Controller Reference Manual Part Number

National Instruments SCB-68 Breakout Box

Quick Guide Book of Sending and receiving card

Cardioline Cube Stress Tango M2 Interface Notes

Camera Setup Instructions

User Manual V2.6. Omniksol WIFIKIT User Manual. Omnik New Energy Co., Ltd.

Pulse Biomedical QRS-Card Tango M2 Interface Notes

HP Media Center Extender Quick Start Guide Start Here

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SwiftMix Automation Safety

HawkEye 1500 Series Quick Start Guide V2.4.1, Nov 2008

AC335A. VGA-Video Ultimate Plus BLACK BOX Back Panel View. Remote Control. Side View MOUSE DC IN OVERLAY

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Philips StressVue Tango M2 Interface Notes

ASKING FOR ASSISTANCE

CytoFLEX Flow Cytometer Quick Start Guide

DTV742 Installation Quick Start Guide

Extremely high sensitivity Live Video Imaging using the SamBa SE-34

DVI to HD-SDI Conversion Box

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

TeamWork Installation Guide

3-DRX. AUTOMATIC THREE CHANNEL DIGITAL AES/EBU REPEATER and ANALOG AUDIO SWITCHER INSTALLATION AND OPERATING MANUAL

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

DTV744 Installation Quick Start Guide

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1.

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

TeamWork Kits Installation Guide

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

VIDEO ALARM VERIFICATION UNIT VIVER

Analog Output for the TSI DUSTTRAK Aerosol Monitor Model 8520

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

CI-218 / CI-303 / CI430

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

Dell Wyse 5030 PCoIP Zero Client

AC334A. VGA-Video Ultimate BLACK BOX Remote Control. Back Panel View. Side View MOUSE DC IN BLACK BOX ZOOM/FREEZE POWER

READ THIS FIRST. Morphologi G3. Quick Start Guide. MAN0412 Issue1.1

User Manual SM-7070WR

Booya16 SDR Datasheet

Document Part Number: Copyright 2010, Corelis Inc.

TransitHound Cellphone Detector User Manual Version 1.3

Configuration Vestas VMP3500

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

8753E, 8753ET, and 8753ES Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit. Applicable Upgrade Kit Model Number

Agilent Parallel Bit Error Ratio Tester. System Setup Examples

Modular Matrix Solution. Complete A/V Signal Control in One Expandable System.

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

DA CHANNEL AES AUDIO MIXER/ ROUTER MODULE

USER GUIDE FOR NETmc MARINE X-Ops

Operation/Reference Guide IRIS. Infrared/Serial Data Capture Unit. Control System Accessories

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

Installation & Operational Manual

MaxView Cinema Kit Quick Install Guide

DXP A0808 Quick Start

Scan Converter Quick Installation Guide

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

Instruction Manual for Electronic Blowers and Flashboards

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

LED Array Board.

RF Solution for LED Display Screen

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

SCALE & WEIGHT DISPLAYS

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

Operation Manual for the Refractive Index detector VE-3580

NX APPLICATION NOTE Led Guided Assembly Connector Pinning with Continuity

Transcription:

Integration of the Zetasizer µv and OmniFACE into an SEC system PARTICLE SIZE MOLECULAR WEIGHT Introduction The Zetasizer µv is a light scattering system capable of simultaneous dynamic (DLS) and static light scattering (SLS) measurements of size and molecular weight. It can be used as a stand-alone batch instrument and can also be integrated into a sizeexclusion chromatography (SEC) system. This allows the system to perform DLS and SLS measurements under chromatographic conditions for measurements of size and molecular weight independent of sample elution volume. The OmniFACE analogue/ digital interface allows the connection of electrical signals from up to two concentration detectors and a trigger signal from an autosampler. The data is all collected and analyzed in OmniSEC, the dedicated SEC software package. Figure 1: The Zetasizer µv and OmniFACE This technical note describes how to integrate the Zetasizer µv and OmniFACE into a third-party SEC system. The fluidic connections are described, as are general electrical connections along with a few specific examples. Finally, instructions on how to connect OmniFACE and the Zetasizer µv to the PC and how to begin data collection are provided. Malvern Instruments Worldwide Sales and service centres in over 65 countries www.malvern.com/contact 2014 Malvern Instruments Limited

Fluidic connections The flow cell may include opaque connectors and tubing that are not appropriate for chromatography. A second set of black PEEK connectors and 1/16 chromatography tubing should be provided with the cell and these should be used (figure 2). In a standard chromatography setup, the eluent will flow from a reservoir through a pump, an autosampler, a column, and finally one or two detectors before flowing to waste. The eluent generally travels through 1/16 tubing after the pump. The black headless PEEK nut should be pushed onto the 1/16 inch tubing. Then the blue or white flat bottom compression fitting provided should be pushed onto the tubing so it is flush with the end of the tube (figure 2). Figure 2: PEEK nut and ferrule connector on 1/16 inch tubing. The Zetasizer µv can be placed at any point in the detector series after the column. This should be done in accordance with the requirements of other detectors which have back-pressure limits that should be carefully followed. The outlet from the column or another detector on the SEC system should be connected to the inlet on the flow cell and then from the outlet of the flow cell to the next detector or to waste (figure 3). The inlet is indicated by an arrow (figure 3A). The cell should be inserted and the lid closed without putting too much tension on the tubing (figure 3B). Figure 3: A. Flow tubing connected to flow cell. B. Cell inserted into Zetasizer µv with tubing coming through side gap. Adding the Zetasizer µv to a third party chromatography setup should have no effect on the system. The flow cell can be removed from the Zetasizer µv, leaving it free 2 Integration of the Zetasizer µv and OmniFACE into an SEC system

for batch use, without having to be disconnected from the fluid connections to other detectors unless desired. Figure 4: The backplate and electrical connections on the OmniFACE. Electrical connections external detectors Analogue cables from SEC systems are often provided by the manufacturer. If unavailable, the appropriate connections can usually be identified and created from the user manuals. On the back of each external detector should be connectors to output an analogue signal (e.g. 0-1V). The manual should help identify the signal out and ground connections from the external detectors. The signal out or + connection should be connected to the UV in HI or RI in HI on the OmniFACE depending on the detector used. The ground or should be connected to UV in LO or RI in LO on the OmniFACE. To test the connection, a run can be started in the OmniSEC software and the signal from the detectors monitored. Electronic connections start signal Many chromatography systems include an autosampler to enable multiple injections to be performed without the need for an operator to be present e.g. overnight. In order to synchronize the actions of the equipment used in this process, most chromatography equipment sends an electrical signal between injectors/pumps/detectors. The OmniFACE can recognize this signal in order to automatically start data collection. The OmniFACE requires that this signal is a contact closure The connector that sends the start signal can be identified by looking at the back of the autoinjector and pump and in the manual. This will be labeled inject start or start signal or trigger signal or similar. The + or signal socket is connected to TRIG SW; on the OmniFACE and the or ground to TRIG GND on the OmniFACE. To test this, a run with an autosampler should be started and then when OmniSEC is waiting for the trigger, an injection can be performed and the measurement should start. GE Healthcare (Amersham) AKTA system The AKTA chromatography system is in common usage throughout the life sciences market. The connections on this system are not standard but can still be connected to the Zetasizer µv. 3 Integration of the Zetasizer µv and OmniFACE into an SEC system

UV analogue signal The analogue signal comes from a 6-pin mini DIN socket located at the back of the instrument (figure 5) labeled Analogue out 0-1V. This contains analogue outputs and grounds for UV, conductivity and ph depending on the configuration of the instrument. A cable may have been provided with the AKTA system but may also need to be created. This will have an appropriate 6-pin mini DIN plug at one end and loose wires at the other. The black wire (1) corresponds to the UV signal out and the brown wire (2) corresponds to the appropriate ground. Connecting these two to the UV in HI and UV in LO sockets on OmniFACE should provide the analogue UV signal. Figure 5: 6-pin mini DIN socket on the monitor UPC-900 and cable required for connecting the analogue signals. When the signal becomes negative, the analogue output from the AKTA is reset to 1 V to show the decrease. To avoid this, an offset can be set into the instrument such that the output signal is 2% (0.02 V) above 0V. This is done on the Monitor UPC-900. Using the wheel select - Set Parameters: UV: Set UV Analogue Out: Set UV zero level. It is useful to include this step to avoid the analogue signal jumping to 1V at random intervals throughout the run. Start signal The start signal can be set to come from the remote socket on the back of the AKTA instrument (figure 6). This is an RS-232 type socket. Pins 6-9 correspond to AuxOut signals and pin 5 is a universal ground signal. 4 Integration of the Zetasizer µv and OmniFACE into an SEC system

Figure 6: 9-pin RS-232 socket for outputting a start signal on the GE AKTA FPLC pump and details for connecting the signals. A new cable should be made by connecting wires to pins 5 and 6 on a new RS-232 plug, or an existing cable can be cut and the wires connecting to pins 5 and 6 identified. The cable is plugged into the socket on the back of the AKTA instrument. The wire connected to pin 5 is connected to TRIG SW on the OmniFACE and the wire connected to pin 6 to TRIG GND on the OmniFACE. The Unicorn software controlling the customer s AKTA system is required to control the signal. Click on manual pump in the menu of the system control application. The menu should include a number of options including AuxOut 1 to 4. If the wire has been correctly connected, then AuxOut1 should act as the start signal. If the aux signals are not present, they need to be activated in the system settings. Go to the Unicorn manager application. Click on admin - system setup. Click on the diagram representing the chromatography system and click edit then on components. Check the box next to Auxiliary equipment and click Ok. The AuxOut signals should now be available in the manual pump options and in the method editor. Waters Alliance 2695 SEC autosampler and 2487 Dual Wavelength Detector The following connections are made between the Zetasizer µv, the Waters Alliance separation unit and the Waters 2487 Dual Wavelength Absorbance Detector (figure 7). 5 Integration of the Zetasizer µv and OmniFACE into an SEC system

Figure 7: External connectors on the Waters Alliance system. UV analogue signal The detector measures at two wavelengths (A & B). One of these can be connected as the UV detector on the OmniFACE. The analogue outputs on this device are screw fittings. UV in HI on the OmniFACE is connected to socket B1 and UV in LO on the OmniFACE to socket B3 for the wavelength A. Start signal The start signal from the separations module can be connected to the Zetasizer µv. The 2695 module has 2 connections for an inject start output labelled B1 and B2. These should be connected to TRIG SW and TRIG GND, respectively. Agilent 1100 and 1200 and HP 1050, 1100 series system These HPLC systems are the white stackable systems. The individual units communicate with each other using CAN connectors that look like Ethernet connectors. HP/Agilent s Variable Wavelength Detector (VWD) and RI At the back of the detector a BNC connector is used to output an analogue signal. The outside is the ground. This should be connected to UV in LO on the OmniFACE and the core of the BNC connector to UV in HI on the OmniFACE as desired. Using the software, the BNC analogue output can be configured to send either the VWD or the dri signal for the RI detector. HP/Agilent s pump The pump has a DB-9 connector at the back labeled REMOTE. Pin 1 connects to TRIG GND on the OmniFACE, while pin 3 from the APG remote goes to the TRIG SW on the OmniFACE. Figure 8 shows the two relevant sockets. 6 Integration of the Zetasizer µv and OmniFACE into an SEC system

Figure 8: Sockets on the rear of the HP/Agilent SEC system Data Collection The Zetasizer µv connects directly to the PC via USB while the OmniFACE connects via a RS-232. The drivers for the Zetasizer µv will be installed with either the Zetasizer or the OmniSEC software. In OmniSEC, the OmniFACE should be connected first. This is done in the Acquire-Search for Devices menu, found under the? menu. TDA 302 Family should be selected and the search started. The software should identify the com port to which the OmniFACE is attached. Click OK (figure 9A). 7 Integration of the Zetasizer µv and OmniFACE into an SEC system

Figure 9: A. Connecting the OmniFACE. B. Connecting the Zetasizer. C. Starting a measurement. Connection of the Zetasizer µv is performed in the Acquire-Configure menu; found under the? menu. Configure is selected next to the in-line DLS. The use DLS box must be checked in order to run the Zetasizer µv. The other options in this box allow the DLS settings and thresholds to be set. Click OK (figure 9B). To start a run, the quick-run button with the play symbol is clicked. The details of the run are filled in and the quick-run button clicked. The software will initialize the Zetasizer and the measurement will be started. If an autosampler is connected, the system will wait for the trigger signal before starting (figure 9C). ÄKTA is a trademark of GE. Healthcare Bio-Sciences AB. Waters Alliance is a registered trademark of Waters Corporation. Agilent, HP and 1050, 1100, 1200 are trademarks of Agilent Technologies Corp. Malvern Zetasizer Nano is a trademark of Malvern Instruments. All other trademarks are acknowledged. 8 Integration of the Zetasizer µv and OmniFACE into an SEC system

Malvern Instruments Limited Grovewood Road, Malvern, Worcestershire, UK. WR14 1XZ Tel: +44 1684 892456 Fax: +44 1684 892789 www.malvern.com Malvern Instruments is part of Spectris plc, the Precision Instrumentation and Controls Company. Spectris and the Spectris logo are Trade Marks of Spectris plc. All information supplied within is correct at time of publication. Malvern Instruments pursues a policy of continual improvement due to technical development. We therefore reserve the right to deviate from information, descriptions, and specifications in this publication without notice. Malvern Instruments shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Malvern Instruments owns the following registered trademarks: Bohlin, FIPA, Insitec, ISYS, Kinexus, Malvern, Malvern 'Hills' logo, Mastersizer, Morphologi, Rosand, 'SEC-MALS', Viscosizer, Viscotek, Viscogel and Zetasizer. 2014 Malvern Instruments Limited