MS-32 Oscilloscope Mixed Signal Option Add 32 Digital Channels to a 4 Channel Oscilloscope
4 Analog + 32 Digital Channel Capability LeCroy introduces the first oscilloscope solution to combine 4 analog channels with 32 digital channels. This is ideal for the most efficient testing of 16-bit embedded controllers, where all 16 ADDR and 16 DATA lines can be viewed at one time. Or, a multitude of ADDR and DATA lines can be viewed, in addition to control lines and low-speed serial data lines (SPI, I2C, etc.). Testing and debugging efficiency is greatly enhanced by eliminating the need to continuously disconnect/reconnect signals to observe different behaviors. 2 4 1 5 6 3 1
Enhanced Test and Analysis Capabilities for Mixed Signal Environments Finally, the ultimate solution for mixed signal oscilloscopes enough channels. LeCroy s MS-32 and a WaveSurfer or WaveRunner oscilloscope provide 4 analog and 32 digital channels for powerful measurement capability. LeCroy now offers the perfect solution for embedded controller testing where Users can capture all their signal there are multiple analog signals information using long memory, coincident with digital signals. Analog or set up digital or analog trigger signals include comparators, voltage conditions to capture the event of sources, sensor/actuator signals, etc.; interest. Signal debug is simple, while digital signals include address using standard oscilloscope tools, or data lines, control signals, or such as cursors, measurement peripheral serial data signals. parameters, and zooming. Leading Features: 32 digital channels Long capture time (1 Mpts/Ch of digital memory) Ability to capture up to 125 MHz digital clocks Simple oscilloscope setup and user interface
Use the MS-32 with Most 4 Channel WaveRunner or WaveSurfer Oscilloscopes 1. Cursors Cursors will read time or bus information, as appropriate. 2. Parallel Bus Definition The digital information obtained by viewing parallel ADDR or DATA bus information can be defined as a bus display. Users can also define a digital trigger for a particular bus value. Up to 4 different buses can be defined. 3. User Interface A familiar interface eliminates the need to spend a lot of time learning a new tool. 4. Resize/Reposition Digital lines can be resized and repositioned anywhere on the oscilloscope grid by using the front panel controls or software menus. 5. Flexibly Trigger Select from a number of different analog triggers; or create a digital trigger by defining a digital trigger pattern, logic bus value, or interval. 6. Long Digital Capture Time Up to 1 Mpts of digital memory/channel ensures that users can capture their area of interest. Quick Setup Unlike a traditional Logic Analyzer, the MS-32 is easy to use. A single module consolidates all of the MS-32/Oscilloscope interconnections, so users can start viewing signals and debugging quickly. In addition, all standard oscilloscope tools are readily accessible. WaveRunner 6000A Series Its higher performance capabilities and longer standard and optional memories are intended for customers who need to perform analysis on long records, or have specific application problems (such as CAN Bus testing). WaveSurfer 400 Series (350 and 500 MHz only) Designed for those customers requiring a basic oscilloscope for signal viewing and for performing basic timing measurements.
MS-32 System Components Available for 6030A, 6050A, 6100A, 6200A Bandwidth Range 350 MHz 2 GHz # Analog Channels 4 6 Analog Sample Rate 5 GS/s per Channel (500 MHz) 10 GS/s max. (6100A and 6200A only) Analog Memory Digital Memory 2 Mpts/Ch standard Options up to 12 Mpts/Ch 1 Mpts/Ch (with MS-32) 2 Application Packages CAN Bus Trigger and Decode Power Measure and Analysis Disk Drive Measure Serial Data Mask Ethernet USB 2.0 Display Size 8.4" 1 4 3 Operating System Windows XP 5 Available for WS434, WS454 Bandwidth Range 350 MHz 500 MHz # Analog Channels 4 Analog Sample Rate 2 GS/s max. Analog Memory 250 kpts/ch Digital Memory 1 Mpts/Ch (with MS-32) Application Packages None Display Size 10.4" Operating System Windows XPe 1 Oscilloscope Interface Module 2 Power Supply 3 USB 2.0 Cable 4 32 Channel Digital Logic Pod 5 10.5" Digital Lead Set 6 Foam Lined Soft Accessory Case 5x Magnifying Glass (not pictured) Small, medium, or large micrograbbers are available as accessories. These are sold in sets of 10, are color coded, and allow easy probing of a variety of IC pin pitches.
Specifications and Ordering Information MS-32 Specifications Digital Channels Number 32 Memory Probe Inputs Threshold Levels Sampling Rate Minimum Input Voltage Range Digital Channel Grouping Triggering Digital Trigger Setup Type Logic Setup Logic Bus Setup Interval Accuracy Certifications 1 Mpts/Ch 240 kω // 10 pf TTL, ECL, CMOS (2.5, 3.3, 5 V), PECL, or User Defined. 1 ks/s to 500 MS/s ±300 mv around the threshold voltage setting 4 digital groups can be defined. Each group may use any combination of 32 digital lines. Groups can be displayed as individual lines, or collapsed into a bus view. User selectable analog (i.e., std. oscilloscope trigger) or digital trigger Physical Dimensions Pod Dimensions (WxLxD) 3.8" x 6.3" x 1.2" (9.6 x 16 x 3 cm) Pod Weight 14 oz. (397 g) Complete System Dimensions (WxLxD) 12.5" x 9.75" x 2.5" (32 x 25 x 6.4 cm) Logic, Logic Bus, or Interval Up to 32 digital lines, with any combination of 0, 1, or X (don t care). In addition, a Rising Edge, Falling Edge, or Either Edge condition may also be set (Note: multiple edges are OR combined). Up to 32 digital lines, defined in hexadecimal format Define a single digital line, the slope, the condition, and the time period in which the second occurrence of that digital line should occur. Available conditions are <, >, In Range, Out of Range. +/-1 digital sample (based on digital sample rate) CE Approved. Conforms to EN61326-1 and EN61010-1, EN Customer Service LeCroy scopes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our digital oscilloscopes are fully warranted for three years. This warranty includes: Calibration No charge for return shipping Long term 7-year support Upgrade to latest software at no charge M D N M Pr Th Sa M D Tr D Se Lo Lo In A C Ph Po Po C C Le th Oscilloscope Mixed Signal Option Product Code 32 Digital Channel Oscilloscope Mixed Signal Option for MS-32 LeCroy WaveSurfer 400 Series and WaveRunner 6000A Series Oscilloscopes Included with MS-32 32 Digital Channel Logic Pod with Power Supply 10.5" (27 cm) Lead Set 6 ft. (1.8m) USB 2.0 Cable Oscilloscope Interface Module with 5 ft. (1.5 m) Cables Soft Accessory Case Magnifying Glass (5x) Printed Operator s Manual (English) Quick Reference Guide (English) CE Conformance Certificate Accessories for MS-32 14" (35 cm) 32 Digital Channel Lead Set (for clock speeds < 25 MHz) MS-32-StdLeads-L Large gripper probe set for 0.10" (2.54 mm) pin pitch, includes 10 probes with color-coded leads PK400-1 Medium gripper probe set for 0.04" (1.0 mm) pin pitch, includes 10 probes with color-coded leads PK400-2 Small gripper probe set for 0.008" (0.2 mm) pin pitch, includes 10 probes with color-coded leads PK400-3 Mictor connection cable, 3" long (7.6 cm), 38-pin MS-32-Mictor-S Mictor connection cable, 14" long (35.6 cm), 38-pin (for clock speeds < 100 MHz) MS-32-Mictor-L 1-800-5-LeCroy www.lecroy.com Local sales offices are located throughout the world. To find the most convenient one visit www.lecroy.com 2005 by LeCroy Corporation. All rights reserved. Specifications subject to change without notice. DCMS32 WEB1 02/05