STALLATION GUIDE.4 Inch TFT Terminal Time Attendance & Access Control
Optional accessories Safety Precautions The following precautions are to keep user s safe and prevent any damage. Please read carefully before installation Do not install the device in a place subject to direct sun light, humidity, dust or soot. Wiegand Card Reader Prox Card Do not place a magnet near the product. Magnetic objects such as magnet, CRT, TV, monitor or speaker may damage the device. Do not place the device next to heating equipment. Be careful not to let liquid like water, drinks or chemicals leak inside the device. FR00 FP Reader K- Exit Button Do not let children touch the device without supervision. Do not drop or damage the device. Do not disassemble, repair or alter the device. Door Lock Door Sensor Do not use the device for any other purpose than speci ed. Clean the device often to remove dust on it. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. Contact your supplier in case of a problem.
I I 3 4 Product P Diagram Camera.4-Inch TFT LCD pin Cable connectors 4 pin Cable connectors (TCP/IP) 7 pin Cable connectors Wiegand Out Beep, LED Wiegand In Power Out Keypad Doorbell & LED Indicator Fingerprint Sensor & Card Reader USB Storage Device Port Reset Button Lock Bell Auxiliary In Wiegand In Power Out pin Cable connectors pin Cable connectors Tamper alarm button Lock Exit Button Door Sensor Doorbell Auxiliary In Speaker Security Screw holes (for securing the device onto the back plate) Lock Bell Auxiliary In I I
5 6 Product Dimension Cables and Connectors.07in (05mm) 7.34in (6.5mm) Digital input and Relay output Red Black 3 4 Black 5 6 Blue 7 Red Yellow 9 Orange 0 Green Purble Aux Brown Lock Exit Button Door Sensor Doorbell Auxiliary In 3.39in (6mm).7in (45.mm) 3.0in (76.mm) Wiegand output and Yellow Blue 3 Black 4 Purple 5 6 Black 7 Green Wiegand Out 7 Wiegand input and Power out Brown 3 Blue 4 I Green 5 I 6 Black 7 Red Beep LED Wiegand Input Power Out 4 Power 3 4 5 6 7 RJ 45 Black Red 3 Green 4 Yellow Black Red TCP/IP
I I I I 7 Mounting the device onto the Wall Power Connection Fix the back plate onto the wall using wall mounting screws Without UPS We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam cannot be found, then use the supplied drywall plastic mollies (anchors). V DC V DC Adaptor With UPS (Optional) V DC V DC Adaptor Inserting the device to backplate Use security screws to fasten the device to back plate Recommended power supply V ± 0%, at least 500mA. To share the power with other devices, use a power supply with higher current ratings
I I 3 4 56 7 I I 3 4 56 7 9 0 Connection LAN Connection Direct Connection 4 4 Network Cable Adaptor Network Cable Adaptor RJ 45 RJ 45 Cable Cable Black ZKBiosecurity 3.0 Red ZKBiosecurity 3.0 3 Green 4 Yellow Black Red 3 Green 4 Yellow
I I Connection Connection ZKBiosecurity 3.0 B A Yellow Blue 3 Black 4 Purple 5 6 Black 7 Green # BioPro SA30 # BioPro SA30 #63 BioPro SA30 Do not use Incorrect RS 45 connections x B A Important Notes:. communication wires should be a shielded and twisted pair cable.. communication wires should be connected in a bus cascade instead of a star form, to achieve a better shielding e ect by reducing signal re ection during communications. x # BioPro SA30 # BioPro SA30 #63 BioPro SA30 3. Adjust the communication speed as needed. The signal quality vary depending on wiring conditions, and it maybe necessary to lower the baudrates. 4. The Signal may be omitted if and only if the potential di erence is less than ±5V B A # BioPro SA30 # BioPro SA30 #63 BioPro SA30
I I 3 4 Connection FR00 Connection System Settings Brown 3 Blue 4 I Green 5 I 6 Black 7 Red Do not use Yellow Blue 3 Black 4 Purple 5 6 Black 7 Green Select > Comm Select > Serial Comm 7 Select > /45 Change > to (master unit) 00 FC R0HS DIP Settings. There are six DIP switches on the back of FR00, switches -4 is for address, switch 5 is reserved, switch 6 is for reducing noise on long cable.. If FR00 is powered from ProCapture terminal, the length of wire should be less than 00 meters or 330 ft. 3. If the cable length is more than 00 meters or 600 ft., the number 6 switch should be ON as below FR00 ON 3 4 5 6 Distance: More than 00 meters ON 3 4 5 6
I I I I 5 6 Lock Relay Connection Device does not Share Power With The Lock Device Shares Power With The Lock V DC V DC V DC Adaptor 7 Red Black 3 4 Black 5 6 Blue 7 Red Yellow 9 Orange 0 Green Purble Aux Brown Do not use Sensor - FR07 Diode + Red Black 3 4 Black 5 6 Blue 7 Red Yellow 9 Orange 0 Green Purble Aux Brown Do not use Sensor - FR07 Diode + Normally Closed Lock Notes:. The system supports LOCK and LOCK. For example the LOCK (normally open at power on) is connected with '' and '' terminals, and the LOCK (normally close at power on) is connected with ''and '' terminals.. When electrical lock is connected to the Access Control System, you must parallel one FR07 diode (equipped in the package) to prevent the self-inductance EMF a ecting the system.! Do not reverse the polarities. Normally Closed Lock
I I 45+ 45- S V+ V- 45-45+ PWR RUN ACT GRD 7 Connection Standalone Installation ZKBiosecurity 3.0 ZKBiosecurity 3.0 Yellow Blue 3 Black 4 Purple 5 6 Black 7 Green Do not use PWR /45 Converter Sensor ALARM EXT CARD R LAN SWITCH OUT OUT OUT3 OUT4 LOCK LOCK LOCK3 LOCK4 LOCK POWER Advanced Access Control Best Security Solution for the World EXT CARD RUN POWER 3 4 EXT STATE READER TON 3 READER 3 TON 4 READER 4 READER TON 3 READER 3 BU GRD Lock No Touch EXIT Exit Button Doorbell
LAN 3 4 EXT STATE TON READER TON READER TON 3 READER 3 TON 4 READER 4 Best Security Solution for the World SWITCH OUT EXT OUT OUT3 OUT4 LOCK LOCK CARD LOCK3 RUN LOCK4 LOCK V+ V- POWER POWER 9 0 Third Party Controller How Does BioPro SA30 work Connection Fingerprint must be registered rst by any nger print reader ZKBiosecurity 3.0 Fingerprint Database Identi cation Finger Registration 45+ 45- S 45-45+ PWR RUN ACT GRD Event Log Stored Veri cation failed Advanced Access Control Please try again! Veri cation Granted Wiegand Wiegand Wiegand Wiegand Thank You Door Opens Outside Inside Lock CARD R READER TON 3 READER 3 BU Lock Inside Outside
How to Place a Finger on Scanner ZKTecos ngerprint readers will give optimal results for ngerprint matching if the following recommendations and suggestions are followed. Select a nger to enroll It is recommended to use an index nger or a middle nger. Thumb, ring or little nger are relatively di cult to place in the correct position DO T place the nger in the following positions Upright Skewed If a nger is placed as shown on the left, only a small area of a nger is captured. So it is recommended to place a nger as shown on page. How to place a nger on a sensor Place a nger such that it completely covers the sensor area with maximum contact. Place core of the ngerprint at the center of the sensor. The core of a ngerprint is a center where the spiral of ridges is dense. (Usually core of ngerprint is the opposite side of the lower part of a nail.) Place a nger such that the bottom end of a nail is located at the center of a sensor. Sideways Tips for di erent ngerprint conditions ZKTecos ngerprint products are designed to verify ngerprints with highest security irrespective of the conditions of the skin of the nger. However, in case a ngerprint is not read on the sensor, please refer to the followings tips. If a nger is stained with sweat or water, scan after wiping moisture o. If a nger is covered with dust or impurities, scan after wiping them o. If a nger is too dry, please blow some warm air from your mouth on the nger tip. Tips for ngerprint enrollment Partial In ngerprint recognition, enrollment process is very important. When enrolling a ngerprint, please try to place the nger correctly with utmost care. In case of low acceptance ratio, the following actions are recommended. Delete the enrolled ngerprint and re-enroll the nger. Try another nger if a nger is not easy to enroll due to scar or cuts. In case of an enrolled ngerprint cannot be used due to injury or if the hand is full, it is recommended to enroll more than two ngers per user.
3 Troubleshooting. Fingerprint can not be read or it takes too long. Check whether a nger or ngerprint sensor is stained with sweat, water, or dust Retry after wiping o nger and ngerprint sensor with dry paper tissue or a mildly wet cloth. If a ngerprint is too dry, blow on the nger and retry.. Fingerprint is veri ed but authorization keeps failing. Check whether the user is restricted by group or time zone. Check with administrator whether the enrolled ngerprint has been deleted from the device for some reason. 3. Authorized but door does not open. Check whether the lock open duration is set to appropriate time, which opens the lock. Check whether anti-passback mode is in use. In anti-passback mode, only the person who has entered through that door can exit. 4. Why device display system broken and the alarm is ringing. Check whether the device and back plate are securely connected to each other. If not, a tamper switch is activated which triggers the alarm and keeps it ringing. 5. How to set ProCapture used as ngerprint reader on inbio access controller. Reeference the Connection on page 7. Enroll personnel s P in inbio panel as a card