A new generation of access control.

Similar documents
2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

what s in the Box? Camera transmitter with power cable 3M sticker 2 RVS SYSTEMS

SAPLING WIRED SYSTEM

CGA0101 Wireless Cable Gateway Quick Installation Guide

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Universal Wireless HDTV Adapter

HTE Owner s Manual. HDMI, RS-232, IR & Ethernet Extender over HDBaseT with 3D, 4K, POE Support

AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

Dell Wyse 5030 PCoIP Zero Client

TAC1 Telephone Entry System

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Dissolved Oxygen Transmitter

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

PoE Over Coax Extender Kit

User Manual. VGA and Audio Cat-X AV Extender V1.0 AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T AVE-304TR AVE-308TR


SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

4, 8, 16 Port VGA and Audio Extender / Splitter with Audio over Single CAT5

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

POC2052-4P-1CX PoE Over Coaxial Extender User Manual

Quick Operation Guide of LTN7700/7600 Series NVR

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Omega 4K/UHD Three-Input Switcher. Introduction. Applications. for HDMI and USB-C with HDBaseT and HDMI Outputs

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

LBC-H2CS-T/R-Lite LINK BRIDGE TM HDBASET HDMI 2.0 EXTEDER 4 PLAY

NanoStation NanoStation. NanoStation. Compact, Hi-Power, 2x2 MIMO AirMax TDMA Station. *Respaldo y Garantía. Datasheet

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

LBC-HDBT LINK BRIDGE TM HDBASET HDMI TRANSMITTER SYSTEM

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

Absolute Encoders Multiturn

Cat5 DVI-D Extender. User s Guide Avenview Inc. All rights reserved.

Dissolved Oxygen Transmitter

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

Video Extender DS128 DSRXL. Instruction Manual. 8-Port Cat5 VGA Digital Signage Broadcaster with RS232 and Audio

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

Assembly. Front view. LEDs. Parametrization interface. Power Bus

FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

EZ-LIGHT K30L Series With Independent Push Button Contact

Datasheet IVU.box.touch

Introduction Congratulations and thank you for purchasing W Box Technologies 0E-HDMISPL2.

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

HexPort Multi-Band Antenna

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

User Manual. AtlonA. Passive VGA Extender with Wall Plate or Box options up to 330ft over 1 x CAT5/6/7 Cable AT-VGA100-SR and AT-WPVGA-SR AT-WPVGA-SR

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Multi-Format AV Scaler with DisplayPort

ex 800 Series ematrix System

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

VGA & RS232 Extender SET over Single CAT5 with RGB Delay Control

Supply voltage 230 V AC Service button 1. Power connector Light track contacts Service LED 1, red

Instruction Manual. Wireless Transmitters (Digital) RVS-550W. Reverse With Confidence 1

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

Mini Gateway USB for ModFLEX Wireless Networks

DM-TX-201-C DigitalMedia 8G+ Transmitter. Supplemental Guide Crestron Electronics, Inc.

User Guide. HDMI Active Cable Extender. DVI-7370c

PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter. User s Guide. Made in Taiwan

S6-R READER. Installation and Operating Instructions

VideoEase HDMI 3x1 Switcher Kit (110V) Installation Guide

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

MARCO CORNER, 19/ THIENE (VI) ITALIA

VBOX III 100Hz GPS Speed Sensor. User Guide. Page 1 of 21. VBOX III SPS User Guide

ТМ-04 Multichannel long range UHF alarm transmitter Operating manual. Sectron Ltd.

ZIPABOX2. Modular smart home server. Quick-Start Guide. v1.3

LD OEM/LD PDS/LD PeCo

TC3301. User's Manual

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

ZIG-POC-100. HDBaseT HDMI Extender

Simple View TM. From the beginning to the end. We leave nothing out when it comes to your satisfaction.

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

HCE II Owner s Manual HDMI, and IR Extender over HDBaseT with 3D, 4K Support

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

Introduction. Package Contents. Installation Requirements

KACO-display. Wireless Solar Monitoring System. Operating Instructions KACO-display. full of energy...

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

DLP200M 2 Relay Module for Heating and Cooling Plants

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

User Guide. HDMI Fiber Optic Extender. DVI-7350a

NanoBridge. NanoBridge. Hi-Performance & Cost-Effective MIMO Bridging. Datasheet. Models: NBM9, NBM2, NBM3, NBM365, NBM5. Hi-Performance, Long Range

H.264. Mobile DVR 4CH

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Extender w/ RS-232 and 2-way IR

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

MS2540 Current Loop Receiver with RS485 Communication

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

HDMI Extender over UTP Cable

CH-1605RXV 4K UHD+ HDMI over HDBaseT 2.0 Receiver (PD) with HDR/ARC

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

CH-1602TX & CH-1602RX HDMI/Audio over CAT5e/6/7 Extender with 48V PoE

PRELIMINARY. Orbis CU. Preliminary Data Sheet!

Transcription:

TM A new generation of access control. 2 or 4 Door Expandable Controller INSTALLATION MANUAL

Installation overview: Installation Diagram Switch Alpha 4 Alpha 4 + PoE Alpha 4 + PoE Alarm central Accessory module Cable specifications and distances Cable type and max. distance for an eventual RS485 BUS between Alpha centrals: 1 UTP cable 4 x 2 AWG23 (0.6 mm) Cat. 6 or UTP cable is a 4 x 2 AWG24 (0.5 mm) Cat. 5 type - max. dis-tance 1000 m Distance from Alpha central to online door and cable type 164 ft 246 ft 328 ft 656 ft Nexus reader (RA/RB, Supply, RE & DM) Lock type: elec-trical strike - consumption 200 ma In a UTP Cat. 6 1 or a UTP cat. 5 2 cable - 1 pair for RA/RB, 1 RE and 1 pair for DM. In a UTP Cat. 6 1 or a UTP cat. 5 2 cable - 1 pair for + and (this can be the same cable as the reader if there is a free pair). In a UTP Cat. 6 1 or a UTP cat. 5 2 cable - 1 pair for RA/RB, 1 RE and 1 pair for DM. In a UTP Cat. 6 1 or a UTP cat. 5 2 cable - 1 pair for + and (this can be the same cable as the reader if there is a free pair). 1 The recommended UTP cable is a 4 x 2 AWG23 (0.6 mm) Cat. 6 type 2 The recommended UTP cable is a 4 x 2 AWG24 (0.5 mm) Cat. 5 type In a UTP Cat. 6 cable 1-1 pair for RA/RB, 1 pair for +, 1 pair for and 1 pair left for RE or DM. If both functions are needed free pairs in the lock cable can be used. In a UTP Cat. 5 cable 2-1 pair for RA/RB, 1.5 pair for + and 1.5 pair for. If RE or DM functions are needed free pairs in the lock cable can be used. In a UTP Cat. 6 1 or a UTP cat. 5 2 cable - 1 pair for + and 1 pair for. In a UTP Cat. 6 cable 1-1 pair for RA/ RB, 1 pair for +, 1 pair for and 1 pair left for RE or DM. If both functions are needed an extra cable has to be used. In two UTP Cat. 5 cables 2-1 pair for RA/RB, 1 pair for RE and 1 pair for DM in cable no. 1 as well as 2 pairs for + and 2 pairs for in cable no. 2. In a UTP Cat. 6 1 or a UTP cat. 5 2 cable - 2 pairs for + and 2 pairs for. Note a The calculations of voltage drop are based on an output from the back-up battery on 12 VDC. During normal operation on 230 VAC the central supply the lock and the lock with 13.9 V. Note b Wiring for most door phones can also be included in the same UTP cable as the reader or the lock if there are free pairs available. DIN-rail mounting box with Alpha Central, and back-up battery: Alpha central Free space for other devices Battery on the shelf

Installation diagram for Alpha 2 and 4 door centrals (incl. installation of a standard Nexus reader) Specifications on sockets Empty space for writing real doorname on hardware 10/100 MBIT Ethernet interface RJ45 Socket CA & CB is a RS485 BUS for connecting several Alpha centrals on a local BUS Input 1: Can be used as tamper input (voltage free) from a sensor in the mounting box or as input 2 Input 2 is a voltage free general input e.g. alarm integration or similar. It can activate outputs on any Alpha + PoE central in the system through the Nova software 14.4 VDC from Supply to reader 13.9 VDC, max 500 ma RS485 BUS to communication with reader Doorlock output- transistor output on 12 VDC, max 500 ma Doorlock output - NO-N-NC relay for max 30 VDC, 5A Empty space for writing IP adress on the hardware Input/output to battery back-up 12 VDC battery Request to exit from inside Door monitor to check if the door is closed after opening The central s pre-loaded IP-adress is written on the sticker on the backside of the central 12 VDC max 500 ma Green light indicates that door 2 is open Red light indicates a short cut. The over current protection is on. BEFORE installation please contact your IT/network administrator to get usable IP-addresses Green light indicates that door 1 is open Green light indicates that door 3 is open Green light indicates that door 4 is open Warning: Reset to original IP adress - If pushed for more than 10 seconds the central will reset to its original (pre-loaded) IP-adress (192.168.1.100) Amber LED indicates controller heartbeat. It blinks slowly, when the controller is alive and on 230 V. When powersupply comes from the battery, it blinks fast Warning: Reset button - resets the central. If pushed for more than 30 seconds the central will reset completely. All current settings will be deleted. The central s original (pre-loaded) IP-adress (192.168.1.100), settings and original passwords will be loaded.

Installation diagram for Alpha 2 or 4 + PoE centrals (only extra functions are shown on the central) + installation of 2 readers in one cable and a Nexus P reader with external antenna Reader housing (art. no. 802-000-4100) to be mounted inside the door. The external antenna can be mounted behind a Stainless steel shield (art. no 802-000-4103) Reader rills in a stainless steel doorstation panel (art. no. 802-000-4102) In a PES06 --> 20 & a PDS01 doorstation from TCS (art. no. 802-000-4101) In an info-module from for example Siedle or similar doorstations (art. no. 802-000-4103) The antenna is delivered with 3 m cable, which may not be extended. External antenna with diodes and buzzer in some variants) 10/100 MBit Ethernet interface with PoE - RJ 45 socket. The Alpha central, connected readers, and locks can be supplied through PoE from the switch. According to the PoE + IEEE 802.3at standard, the central is only supplied with 25W in total. You need to be aware that 25 W only have the capacity to supply a single Alpha central with 4 readers (in/out passage) at 2 locks (doors), as long as the locks power consumption is less than 15 W. If the conditions are met, a 25 W PoE supply can allow the central to keep doors open for a longer period of time, e.g. the opening hours of a firm. If the Alpha + PoE is not supplied by a PoE switch it has to be supplied by a 14.4 VDC. This article is bought as an accessory to the Alpha + PoE central. One cable with 10 wires 1 One cable with 4 wires 1 In case of PoE supply and the switch is backed up by a central UPS a local battery backup is not necessary in case of power failure. The Alpha + PoE versions are equipped with an USB socket. This socket allows for use of: A Wifi antenna (available in 1. qty 2012) enabling the central to be connected to a wireless LAN network To take a back-up of the system set-up and memory with a USB memory stick Accessory moduls which extend the functions of the Alpha central extensively. Examples of accessory moduls are extra input module, extra output module and I/O combined module (All available in 2. qty 2012). These modules makes it possible to have for example elevator control, multi-alarmzone integration, parking control, and more. The readers has to be connected in serie on the CA & CB BUS in order for it to work Relay 1 & 2 are controlled by the Nova Software (version available in 1. qty 2012). The relays can for example be used for alarm bypassing, alarm activating or similar. The relays can through the Nova software be triggered by an input on any Alpha central in the system, by an event in the software, an action of a user and so on. If the readers have the same MODBUS adress on the same RS485 BUS it will give a search error in the software. Then connect only one of the readers and change the MODBUS adress with the software. Note 1: If you want to have more doors on the same cable, you need more wires to accommodate for the functions at the door. Alternatively, if you do not need doormonitor and/or exit call button, you can reduce the number of wires. The cable diameters and the distances mentioned in the cable specification on pages 1 is no longer applicable due to higher consump tion. Diameters and distances has to be calculated and measured on the place of installation.

Product specifications on Alpha centrals and Nexus readers Alpha centrals Nexus readers Specifications Supply voltage Battery backup Real time clock backup capacitor 200MHz CPU with 64MB RAM 512 MB Flash 100.000 users 1.000.000 events log 14.4 VDC +/- 10%, when used with battery backup supply volmust be between 13.9 VDC and 14.6 VDC. The central s consumption without external loads is 150mA at 14.4 VDC (2W). Maximal consumption is limited to 60W. 12 VDC, 2.1 Ah Minimum 24h Operating temperature 4 F to 185 F If used with battery backup, please check battery limitations. Communications 1x J45 10/100 MB Ethernet port 1x RS485 central communications port 1, distance up to 1000m 1x USB host port 3 Readers 2x or 4x RS485 ports 1 supports up to 4 or 8 readers using MODBUS protocol. Maximal power output for each reader port is 500mA at 13.9VDC. Outputs 2x or 4x lock outputs each as relay (max. 30VDC, 5A) and transistor MOSFET output (13.9 VDC at max. 500mA 2 ). 2x auxiliary output relays (max. 30VDC, 5A) Alarm output Use auxiliary relay output 3 Inputs 2x or 4x requests to exit (voltage free) 2x or 4x door monitors (voltage free) 2x auxiliary inputs (voltage free) Galvanic isolation is provided on all input channels with optocouplers. Tamper switch (Art.no.: 800-000-9001) Optional, use auxiliary input PoE (only +PoE models) Powers up to 25 W, according to standard for PoE+ IEEE 802.3at 3 Dimensions Central housing is 8-3/8 long, 3-1/2 wide and 2-1/2 high for 35mm DIN-rail. System housing for power supply, central, and battery holder is 11-1/4 long, 14-1/4 wide and 4--3/8 high, IP 40, 2 rows of 12 modules Weight 230g Standards and certificates CE Installation Installation of equipment must be done by a professional electrician on restricted access location Color White Material Central housing is made of self-extinguishing blend PC ABS, system housing is made of Acrylonitrile Butadiene Styrene (ABS) Warranty 2 years Note 1 Use AWG23 (0.6mm) Cat. 6 or AWG24 (0.5mm) Cat. 5 Note 2 Maximal overall power consumption of all readers and all transistor outputs is limited to 4A at 13.9 VDC (55.6W). When central is powered over PoE, maximal overall power consumption is 25W. Note 3 PoE, USB, auxiliary inputs and outputs are only available on centrals Alpha2+PoE and Alpha4+PoE. Specifications Cortex M3 CPU Supply voltage Min 9V DV - Max 24V DC Typical supply current 72mA at 14V DC, 1W, with keypad 180 ma at 14V DC, 2.5W Peak current 150mA at 14V DC, 2.1W, with keypad 200 ma at 14V DC, 2.8W Operating temperature 20 C to 70 C Storage temperature 45 C to 85 C Communications RS485 port, using MODBUS protocol with encrypted data 1 LED indicator Two color: red for locked door and green for open door Buzzer Short beep if access is granted and longer error beep for otherwise. For each key pressed, you will hear short click sound and see blink of green LED Transmit frequency 13,56 Mhz (Nexus M or MK) or 125 khz (Nexus P or PK) Reading distance Nexus Prox - ISO card: typical 40mm Nexus Prox - Tag: typical 30 mm Nexus Mifare - ISO card: typical 30mm Nexus Mifare - Tag: typical 20 mm Recommended mounting 130-160 cm height Cable length 3m Max cable distance from central 50m - Check cable specifications for details Wiring Orange + 9-24V DC input Orange/White - Ground Green RA RS-485 BUS Green/White RB RS-485 BUS Anti-sabotage protection (tamper switch) Optical, integrated Dimensions Width:54mm x length:149mm x height: 15mm Weight 165g Standards and certifications CE IP protection IP 65 Color Black Material Self-extinguishing material PC-ABS (V0) Warranty 2 years Note 1 Available with firmware update Table for location notes Location IP-adress MAC-adress

TRANSMITTER SOLUTIONS WARRANTY The warranty period of the Prima Controller is twenty -four (24) months. This warranty shall begin on the date the controller is manufactured. During the warranty period, the product will be repaired or replaced (at the sole discretion of Transmitter Solutions) if the product does not operate correctly due to a defective component. This warranty does not extend to (a) the product case, which can be damaged by conditions outside the control of Transmitter Solutions, or (b) battery life. This warranty is further limited by the following disclaimer of warranty and liability: EXCEPT AS SET FORTH ABOVE, TRANSMITTER SOLUTIONS MAKES NO WARRANTIES REGARDING THE GOODS, EXPRESS OR IMPLIED, INCLUDING WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS, EXPRESS OR IMPLIED, WITH REGARD TO THE GOODS AND ACCEPTS THEM AS-IS/WHERE-IS. TRANSMITTER SOLUTIONS SELLS THE GOODS TO BUYER ON CONDITION THAT TRANSMITTER SOLUTIONS WILL HAVE NO LIABILITY OF ANY KIND AS A RESULT OF THE SALE. BUYER AGREES THAT TRANSMITTER SOLUTIONS SHALL HAVE NO LIABILITY FOR DAMAGES OF ANY KIND, WHETHER DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING INJURIES TO PERSONS OR PROPERTY, TO BUYER, ITS EMPLOYEES OR AGENTS, AS A RESULT OF THE SALE. BUYER ALSO AGREES TO HOLD TRANSMITTER SOLUTIONS HARMLESS FROM ANY CLAIMS BUYER, OR ANY THIRD PARTY, MAY HAVE AS A RESULT OF BUYER S USE OR DISPOSAL OF THE GOODS. BUYER HAS READ THIS DISCLAIMER AND AGREES WITH ITS TERMS IN CONSIDERATION OF RECEIVING THE GOODS.