Cable Operator Inputs for 100G+ Beyond 10k

Similar documents
DOCSIS 3.1 Development and its Influence on Business

WDM Video Overlays on EFM Access Networks

Upgrade of 450/550 MHz Cable Systems to 600 MHz Using a Phase Area Approach. Robb Balsdon Vice President, Engineering Services Rogers Engineering

Analysis on Feasibility to Support a 40km Objective in 50/200/400GbE. Xinyuan Wang, Yu Xu Huawei Technologies

500 m SMF Objective Baseline Proposal

Review of the Comcast. Fort Collins Cable System. Technical Characteristics

1/31/2009. Technical highlights session PRODUCTS & SERVICES Summary. Sam Tagliavore PBN-FTTX

MEASUREMENT- BASED EOL STOCHASTIC ANALYSIS AND DOCSIS 3.1 SPECTRAL GAIN AYHAM AL- BANNA, DAVID BOWLER, XINFA MA

Meeting Minutes Group: IEEE P802.3ca 100G-EPON Task Force

SMF Ad Hoc report. Pete Anslow, Ciena, SMF Ad Hoc Chair. IEEE P802.3bm, Geneva, September 2012

Symmetrical Services Over HFC Networks. White Paper

Opti Max Nodes Digital Return System

MIGRATION TO FULL DIGITAL CHANNEL LOADING ON A CABLE SYSTEM. Marc Ryba Motorola Broadband Communications Sector

OPTICAL DISTRIBUTION STATION -

REGIONAL NETWORKS FOR BROADBAND CABLE TELEVISION OPERATIONS

An Effort to Create Multi-vender Environment for 100 Mb/s P2P optical Ethernet Access in Japan

40GBASE-ER4 optical budget

CHP Max Headend Optics Platform CHP CORWave II

December Spectrum Management and Telecommunications Policy

Hands-On Real Time HD and 3D IPTV Encoding and Distribution over RF and Optical Fiber

An Approach To 25GbE SMF 10km Specification IEEE Plenary (Macau) Kohichi Tamura

Cisco 10GBASE Dense Wavelength-Division Multiplexing XFP Modules

DOCSIS 3.1 roll Out First Lessons Learned DOCSIS 3.1 roll Out First Lessons Learned

Business Case for CloudTV

White Paper. Performance analysis: DOCSIS 3.1 cable TV headend combining systems

Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules

CABLE S FIBER OUTLOOK SURVEY REPORT

10GBASE-LRM Interoperability & Technical Feasibility Report

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

400G-FR4 Technical Specification

100G-FR and 100G-LR Technical Specifications

WHITE PAPER. Comprehensive Node Analysis Assures Big Upstream Gains For DOCSIS 3.0 Channel Bonding

THE SPECTRAL EFFICIENCY OF DOCSIS 3.1 SYSTEMS AYHAM AL- BANNA, DISTINGUISHED SYSTEM ENGINEER TOM CLOONAN, CTO, NETWORK SOLUTIONS

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

Further Clarification of FEC Performance over PAM4 links with Bit-multiplexing

Overcoming Nonlinear Optical Impairments Due to High- Source Laser and Launch Powers

Using SOAs as Booster and/or Pre-Amplifier for 4x25-Gb/s 40-km 1310-nm PMD

Prisma D-PON System ONT and Upstream Receiver

Cost Effective High Split Ratios for EPON. Hal Roberts, Mike Rude, Jeff Solum July, 2001

ESTIMATING DOWNSTREAM PERFORMANCE AND DOCSIS 3.1 CAPACITY IN CAA AND DAA SYSTEMS

100GBASE-DR2: A Baseline Proposal for the 100G 500m Two Lane Objective. Brian Welch (Luxtera)

200GBASE-DR4: A Baseline Proposal for the 200G 500m Objective. Brian Welch (Luxtera)

Toward Baseline for 400GBASE-ZR Optical Specs

Automated Connector Processing Tackles Exploding FTTP Connector Market

Extended Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, DWDM, 3R Transponder WaveReady Transponder 740 XLR

from ocean to cloud ADAPTING THE C&A PROCESS FOR COHERENT TECHNOLOGY

FORWARD PATH TRANSMITTERS

DROP HARDENING. January 21, 2015

A Ptolemy Based Optical Network Simulator

SYSTEM DESIGN - NEXT GENERATION HFC

from ocean to cloud CORRELATION BETWEEN AGING MARGIN AND REPAIR MARGIN IN UNREPEATERED SUBMARINE SYSTEMS

Enabling home networking for digital entertainment TM. IEEE Presentation. March 2005

Project: IEEE P Working Group for Wireless Personal Area Networks (WPANs)

Prisma D-PON System 1550 nm Downstream Transmitter and EDFA

GIVING HFC A GREEN THUMB

WaveReady WRT Gbps Extended-Reach DWDM Tunable Transponder with XFP Client Interface

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE STANDARD SCTE

DOCSIS 3.1: PLANS AND STRATEGIES. December 18, 2013

NETWORK MIGRATION DEMYSTIFIED IN THE DOCSIS 3.1 ERA AND BEYOND

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

Impacts on Cable HFC Networks

HRF-xRx RETURN PATH HEADEND SIGNAL ORGANIZATION

COMMISSIONING AND ACCEPTANCE

SWITCHED INFINITY: SUPPORTING AN INFINITE HD LINEUP WITH SDV

MODE FIELD DIAMETER AND EFFECTIVE AREA MEASUREMENT OF DISPERSION COMPENSATION OPTICAL DEVICES

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

40G SWDM4 MSA Technical Specifications Optical Specifications

High Density Optical Platform for FTTx and HFC

EVLA Fiber Selection Critical Design Review

LEARN TO BE AN EXPERT FROM THE EXPERTS IN CABLE TECHNOLOGY.

The current state of multimode OTDR and Light Source and Power Meter (LSPM) Insertion Loss (IL) testing is as follows:

Click to edit Master title style

Proposal for 400GE Optical PMD for 2km SMF Objective based on 4 x 100G PAM4

DOCSIS 3.1 Operational Integration and Proactive Network Maintenance Tools

Module 11 : Link Design

Challenges of Launching DOCSIS 3.0 services. (Choice s experience) Installation and configuration

FiberLink 3350 Series

40G SWDM4 MSA Technical Specifications Optical Specifications

AN INTRODUCTION TO FIBER OPTICS SYSTEMS - PART II

Emerging Subsea Networks

Meeting Minutes Group: IEEE P802.3ca 100G-EPON Task Force

BACKGROUND. Big Apple Case Study 2

Pluggable Transceivers Installation Guide

This presentation will give you a general idea of the subjects on the 18 CATV-HFC seminars that are available from:

RF RETURN OPTIONS AN ENABLENCE ARTICLE WRITTEN BY JIM FARMER, CTO. September,

CFPQD010C10D CFP Dual Fibre 1310nm* / 10km / 100GBASE-LR4 & OTN OTU4

MARGINS ON SUBMARINE SYSTEMS

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

Long Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, CWDM, 3R Transponder WaveReady Transponder 740 LR CWDM

Buildings. Barry Walton Senior Advisor - Access FTTP

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

LEARN TO BE AN EXPERT FROM THE EXPERTS IN CABLE TECHNOLOGY.

TriAccess Solutions. Advanced CATV & High-Speed Data

Dual Link DVI Receiver Implementation

LEARN TO BE AN EXPERT FROM THE EXPERTS IN CABLE TECHNOLOGY.

RFO RF VIDEO EXTENDER REACH FARTHER, SPEND LESS EXTEND YOUR RF OVERLAY COVERAGE WITH A LOW COST SOLUTION

TEPZZ 889A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2017/35

100G MMF 20m & 100m Link Model Comparison. John Petrilla: Avago Technologies March 2013

P802.3av interim, Shanghai, PRC

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

Transcription:

Cable Operator Inputs for 100G+ Beyond 10k Matt Schmitt, CableLabs 5/21/18 1

Supporters David Claussen Charter Phillip Chang Comcast Brian Soloducha Shaw Steve Burroughs CableLabs Alberto Campos CableLabs Curtis Knittle CableLabs Steve Jia CableLabs Jing Wang CableLabs 5/21/18 2

Background Have been discussing a black-link style approach in SG Define requirements for the end-points, and not on the channel in between Concern expressed in prior meetings that this requires engineering of the system, does not allow plug and play type solution Have been working with cable operators to understand Types of network scenarios to be supported What type of solutions are desirable This deck summarizes some of those cable operator inputs, and identifies ways to ensure solutions address their needs 5/21/18 3

Previous Contributions Backhaul for Distributed Architectures in MSOs from Fernando Villarruel (http://www.ieee802.org/3/b10k/public/17_09/villarruel_b10k_01b_0917.p df) Outlined MSO transition from analog to digital fiber links for distributed architectures Key point: MSOs plan to re-use existing fiber in analog to digital transition Beyond 10km PHYs MSO Reference Channels from Curtis Knittle, Matt Schmitt, and Fernando Villarruel (http://www.ieee802.org/3/b10k/public/18_01/knittle_b10k_01_0118.pdf) Provided more detail on MSO use cases and network environment, including example reference channels Key points: 1-2 fibers available, variety of distances and network designs 5/21/18 4

MSO Optical Distance Survey (from Beyond 10km PHYs MSO Reference Channels) Surveyed CableLabs member companies for information on current optical link distances from headend/hub to current fiber node 12 cable operators from Europe and North America responded Weighted average of survey results based on number of subscribers per operator <30km: 69% <40km: 88% <60km: 94% <80km: 98% <120km: 100% 5/21/18 5

Additional MSO Plant Survey Results Number of optical channels 1 channel: 50% 2 to 15 channels: 37% 16+ channels: 13% Future trend: shifting to more optical channels per fiber (roughly 1/3 each) Optical amplification No amplification: 81% Hub only: 12% Other: 7% Bidirectional transmission method Single fiber: 21% Fiber pair: 79% Future trend: expecting single fiber percentage to grow 5/21/18 6

MSO Feedback on Optical Amplification Generally deploy optical amplifiers when attenuation on link is greater than approximately 12-17dB Varies between operators Each link is unique Getting these links to work requires an engineer with appropriate expertise Adjustments made as appropriate Amplifiers added if/when needed While common components are generally used, some amount of adjustment to get each link to work is normal and expected, given range of different channels they operate in 5/21/18 7

General MSO Objective for Beyond 10k Solution Solution needs to be robust enough to work on existing optical plant This will allow for some degree of drop in Should work with most of existing optical equipment/setup May allow removal of optical amplifiers in some cases (for example, if final solution has better reach/link budget performance) However, some degree of engineering of each deployment is expected Plant engineering expertise always needed to deploy 5/21/18 8

How Do We Get There? Define transmitter and receiver specifications for key parameters For example: power levels, OSNR, etc. Sufficient to support compliance testing of solutions Evaluate proposed requirements against example reference channels For example, as in http://www.ieee802.org/3/b10k/public/18_01/knittle_b10k_01_0118.pdf Ensures solution meets key MSO needs Comprehensive set of Tx/RX optical parameters plus common framing and FEC requirements ensures multi-vendor interop over nominal links IEEE strength Enables broad adoption 5/21/18 9

Summary MSO optical plants vary significantly Wide range of scenarios, although defining some examples is possible MSOs expect some degree of engineering to deploy Solutions robust enough for existing optical plant, with engineering expertise to make it work Desire multi-vendor interoperable solutions to drive scale Achievable by developing common requirements in IEEE Black-Link type approach To include appropriate transmitter and receiver requirements 5/21/18 10