FRONT VIEW 1 2 15 3 4 14 13 5 12 6 7 11 10 8 9 1 F CONNECTOR Downstream input 6 Cursor keys 11 Power input 2 F CONNECTOR Upstream input 7 Selection key 12 Speaker 3 LCD display 8 Alphanumeric keypad 13 Main menu key 4 USB connector 9 Battery charging status 14 Softkeys 5 ETHERNET connector 10 ON/OFF key 15 Upstream / Downstream status led PROMAX-37 PDF Find the user's manual on the download area at: www.promaxelectronics.com USER MANUAL DOWNLOAD
ANALYSER EXT.MODEM DOWNSTREAM ANALYSER FR: 4.00 MHz CH:S39 CCIR DBG: 5 CARRIER: 1 / 8 (P) 1 01 : : 13 98 38 db 2.0 10 Ksym/s QAM64 PreBER: 0. 0E+00 PostBER: 0. 0E+00 Interleaver:I=12 J=17 Offset: 17 khz DS SINCHRONIZED MEASURING UP/DOWN IQ SPECTRUM LOGGER DBG CARRIER /EURO RANGING 02 : 12 : DOWNSTREAM 3. 0 UPSTREAM ATT 98 38 db 84 24 db FR: 4. 00 MHz UCD: 1 CH: S39 CCIR FREQ ( MHz):. 00 DBG: 5 BW ( MHz): 3. CARRIER: 1 / 8 SR ( Ksym/s): 24 Ksym/s QAM64 MOD: QPSK PreBER: 0. 0E+00 RANGING COMPLETE PostBER: 0. 0E+00 MEASURING DOWN REGISTER SPECTRUM DBG CARRIER IQ MEASUREMENT 98 38 db FR: 4. 00 MHz CH: S39 CCIR DBG: 5 CARRIER: 1 / 8 10 Ksym/s DVB-C QAM64 PreBER: 0. 0E+00 PostBER: 0. 0E+00 SYNCRONIZED ALL DOWN SPECTRUM DBG CARRIER QUADRANT MODEM MEASURES 0 13 : 04 : 29 10-06-12 LOGGER00 1 13 : 16 00 11-06-12 LOGGER01 3 17 : : : 00 11-06-12 LOGGER03 NEW DELETE VIEW DOWN /EURO REGISTER 02 : 12 : DOWNSTREAM UPSTREAM CH FR MHz db MOD P UC FR/BW MHz ATT SR db MOD. 00. 00 S39 4 98 38 64 1 3. REGISTERED MEASURING DOWN UP/DOWN SPECTRUM LOGGER IPCFG...... 84 24 QPSK - - - DOWNSTREAM SPECTRUM 01 : 13 : 01 70 65 86 MARKER: FR: 4. 00 MHz S39 CH: / CCIR 439. 15 MHz 4. MEASURING MED UPSTREAM PEAK FREQ AVG MAX PEAK STORE MODEM LOGGER This measure will be stored as: LOGGER01 STORE 01 : 43 : 12 MODEM MEASURES 02 : 12 : 0 13 : 04 : 29 10-06-12 LOGGER00 NEW DE LETE VIEW DOWN /Euro REGISTRATION FR: 4. 00 MHz IP CABLE MODEM: IP GATEWAY: NETMASK: IP DHCP SERVER: IP TFTP SERVER: REGISTRATION IP CONFIG SET DOWN REGISTER VoIP IPTV 010. 000. 017. 104 010. 000. 017. 001 2. 2. 2. 000 010. 000. 017. 003 010. 000. 017. 003 02 : 12 : UPSTREAM SPECTRUM 01 : 13 : 10 51 86 MARKER: FR: 5. 00 MHz 5.00 FULL 2. MEASURING: MAX DOWNSTREAM CLEAR ERASE MODEM LOGGER Do you want to erase? : LOGGER00 DELETE 01 : 43 : VoIP QoS ANALYSER (UGS) IP ADDRESS: 010. 000. 017. 003 PLR R Value: MOS: 0. 0 % 93. 2 MIN AVG 4. 41 MAX Latency 0. 0 ms 0. 3 ms 5. 0 ms REGISTER DONE SEND CONFIG 02 : 12 : G711+PLC Jitter 0. 3 ms 0. 5 ms 4. 8 ms LOGGER00 db FR: 90. 00 CH: AUST - Ksym/s - PreBER: - PostBER: - Interleaver: - - Offset: - KHz 01:43: BONDING GROUP CH FREQ AUST MHz........ IPTV QoS ANALYSER (RTPS) S 0. 4 0. 3 0. 2 02 : 12 : IP ADDRESS: 010. 000. 017. 003 NODE: 1/1 IP:010. 000. 017. 003 LATENCY: 11. 6 ms JITTER: 3. 5 ms PLR 0. 0 % 0. 1 TOTAL PLR:.- % REGISTER 0. 0 DONE SEND CONFIG -NODE +NODE
TV ANALOGICA ANALOGUE TV EXT. MODEM VIDEO METER 01 : 28 : 41 FR: 243. 5 MHz CH: S39 /CCIR 72 LVL V/A 15 db C/N db 70 80 90 100 110 1 AUDIO SCAN SPECTRUM LOGGER CHAN AUDIO METER 72 FR: 243. MHz LVL AF: 248. MHz CH: S14 / CCIR F: -0. MHz SOUND: FM V/A 15 db 70 80 90 100 110 1 VIDEO SCAN SPECTRUM LOGGER CHAN F SOUND VOLUME SCAN S SCAN 01 : : 27 65 FR:4. 00 MHz BW:8. 00 MHz 47. 00 FULL 862. 00 TILT SPECTRUM TV SPECTRUM ANALYSER 01 : : 53 65 FR: 465. 00 MHz CH:S39 / CCIR MEASURING: PEAK 4. 00 15 MHz 465. 00 SCAN FAST MAX SLOW PEAK FAST MAX TILT MEASUREMENT 01 : 56 : 10 TILT -7 db 0. 01 db/mhz P1: 100. 00 MHz 48 P2: 0. 00 Mhz P3: 0. 00 MHz 42 P4: 700. 00 MHz.00 7.00 +REF -REF P2 P3 P4 P1 P2
TV DIGITAL EXT.MODEM TV DIGITAL POWER METER 01 : 19 : 41 FR: CH: BW: 4. 00 MHz S31 / CCIR 7. 00 MHz 88 C/N 12 db NOISE : 9. 00 MHz 65 75 85 95 105 115 1 1 IQ SCAN SPECTRUM LOGGER CHAN BW FRECUENCIA CANAL 88 01 : : 36 36 db PreBER: 1. 0E-8 PostBER: 3. 0E-6 4.00 MHz/7.00 MHz S31 / CCIR QAM64 / ksym/s DVB-C ALL Unlocked SCAN SPECTRUM RESET BW MODULATIÓN ANNEX QUADRANT BW TV S SCAN 01 : : 27 65 FR:4. 00 MHz BW:8. 00 MHz 47. 00 FULL 862. 00 TILT SPECTRUM TV SPECTRUM ANALYSER 01 : : 51 65 FR: 465. 00 MHz CH:S39 / CCIR MEASURING: PEAK 4. 00 15 MHz 465. 00 SCAN FAST MAX SLOW PEAK FAST MAX TILT MEASUREMENT 01 : : TILT -7 db 0. 01 db/mhz P1: 100. 00 MHz 48 P2: 0 00 MHz P3: 0 00 MHz 42 P4: 700 00 MHz. 00 7. 00 +REF -REF P2 P3 P4 P1 P2
EXT. MODEM EXTERNAL MODEM SIGNAL METER EXT.MODEM SIGNAL METER FR: 243. 00 MHz CH: S31 /CCIR LVL 72 01 : 44 : 21 70 80 90 100 110 1 AM SCAN SPECTRUM LOGGER VOLUM FM OFF TONO AM OFF VOLUME EXT UPSTREAM SPECTRUM 01 : 43 : 21 42 86 MARKER: FR: 5. 00 MHz MEASURING: MAX 5. 00 FULL 2. DOWNSTREAM CLEAR TV S SCAN 01 : : 22 27 65 FR:4. 00 MHz BW:8. 00 MHz 47. 00 FULL 862. 00 TILT SPECTRUM EXT DOWNSTREAM SPECTRUM 70 65 01 : 43 : 59 86 MARKER: FR: 4. 00 MHz 439. 4. MEASURING: PEAK UPSTREAM FAST MAX SLOW PEAK FAST MAX TV SPECTRUM ANALYSER 4. 00 15 MHz 4. 01 : 46 : 52 65 FR: 4 00 MHz CH:S39 / CCIR MEASURING: PEAK SCAN FAST MAX SLOW PEAK FAST MAX TILT MEASUREMENT 01 : 44 : TILT -7 db 0. 01 db/mhz 80 75 P1: 100. 00 MHz 70 74 65 P2: 0. 00 MHz 69 P3: 0. 00 MHz 67 P4: 700. 00 MHz 65. 00 7. 00 +REF -REF P2 P3 P4 P1 P2
GENERADOR CONFIG CONFIGURATION SETUP SETUP 01 : 43 : 00 EXT.MODEM TEST SIGNAL RECEIVE READY :. 0 MHz POWER: 110 MODULATION: QAM64 : ksym/s SWEEP 01 : 44 : 09 GENERAL CONFIGURATION SYSTEM CONFIGURATION 01 : 44 : 16 POWER MODULATION POWER PLAN EDIT PLAN POWER AT UNITS THRESHOLD NOISE MEAS. MODE NOISE STEP DIGITAL LOGGER TYPE CCIR 70 F 8. 00 MHz 2. 00 MHz BER TIME DATE LANGUAGE BEEP AUTO POWER OFF CONTRAST MAC ADDRESS BATTERY FIRMWARE SERIAL NUMBER 01 : 43 14-03-12 ENGLISH ON OFF 3 00 : : 36 : 10 : CA : 00 8. 15 V 1. 10 123678 TEST SWEEPER RECEIVE - START FREQ.: 5. 0 MHz LAST FREQ.: 85. 0 MHz POWER: 110 MODULATION: QAM64 :51 ksym/s TRANSMITTER 01 : 44 : 27 F.FREQ POWER MODULATION START FREQ. LAST FREQ. EDIT PLAN:CCIR 01 : 43 : 22 NAME OFFSET TYPE ACT D3 C02. MHz +0. 00 MHz D S C03 57. MHz +0. 00 MHz D S C04 64. MHz +0. 00 MHz D S S01 107. MHz +0. 00 MHz D S 05 S02 114. MHz +0. 00 MHz D S 05 S03 121. MHz +0. 00 MHz D S 05 S04 128. MHz +0. 00 MHZ D S 05 S05 1. MHz +0. 00 MHz D S S06 142. MHz +0. 00 MHz D S S07 149. MHz +0. 00 MHz D S S08 156. MHz +0. 00 MHz D S S09 163. MHz +0. 00 MHz D S DBG ALL DIG. EDIT TEST SIGNAL RECEIVER UPSTREAM FR: MOD: SR: db. 0 MHz QAM64 ksym/s TRANSMI RESET S.R. MODULATION EDIT BONDING GROUP: 1 ADD: S01 / 107. MHz S39-4. 00 MHz S - 8. 00 MHz S41-466. 00 MHz C21-474. 00 MHz C22-482. 00 MHz C23-490. 00 MHz C24-498. 00 MHz C - 6. 00 MHz X 01 : 43 : ADD PRIMARI DELETE GROUP ADD EDIT PLAN BW MODULATION SYSTEM 01 : 43 : 53 CCIR C02. MHz 8. 00 MHz +0. 00 Mhz QAM64 ksym/s DVB-C
01:43:09 EXT. MODEM ANALYSER 3.0 This function allows checking the response of a /EURO data transmission system. It works for both Upstream and Downstream. It can store measurements and display a QAM constellation modulation. It can test applications that use VoIP or IPTV protocol, if the cable modem can be registered in the network. 01:43:09 EXT. MODEM This function generates a test signal for testing Upstream traffic and, on the other hand, it can analyse the test signal at the opposite end. It also has a Sweep mode, which makes a sweep within a frecuency range selected by the user 01:43:09 EXTERNAL MODEM EXT. MODEM This function connects the equipment to an external cable modem. It extracts a sample of the Downstream and Upstream signal, displaying their spectrums on screen. EXT.MODEM
01:43:09 ANALOGUE TV EXT.MODEM This function performs an analysis of analogue video and audio carriers. 01:43:09 EXT. MODEM LIGHT CONFIG SETUP ON This function performs an analysis of QAM digital carriers for the standard: - DVB-C (ITU J83 A) - ITU J83 B / C 01:43:09 EXT. MODEM LIGHT CONFIG SETUP ON SIGNAL METER This function measures the level power of the received signal. PROMAX-37 PDF 0 DG0093 Find the user's manual on the download area at: www.promaxelectronics.com USER MANUAL DOWNLOAD