USER MANUAL FOR EXPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE PLFM -.

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

EXPlora. Introduction

LED Driver Compact fixed output

LED Driver Compact dimming

Datasheet - SRB-E-201ST

I Ex-protected connectors exlink I

Emergency lighting units EM powerled

Installation instructions Cable transit device Roxtec RS ES Ex

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

3 Cleaning. 4 Technical data

Emergency lighting units EM powerled

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

7 Lighting Technology

Installation instructions Roxtec RS ES Ex

10 PDUs 19 PDUs Zero-U PDUs

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Installation instructions Ex frames

Pendant Light Fittings Series 6050

02/11/2015

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

XML LED X M L L E D. Explosionproof Linear LED Lighting

Inductive sensor BI1.5-EG08K-Y1

Ordering details. Approval. Classification

Inductive sensor NI3-EG08K-Y1-H1341

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

Datasheet - SRB301LC 24VAC/DC

architecture mounting Features Product lighting

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

8 Installation Equipment

EXLUX ECOLUX 6480 Series

Inductive sensor With analog output BI15-M30-LI-EXI

Linear flow control with actuator IFC

Ultra thin LED lamp for Pool & Spa OWNER S MANUAL

Philips Corepro LEDtube T8

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

MKH 8060 Directional studio microphone

ACTIVE IF SPLITTER/COMBINER UHP-IFS

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Technical Information

OT 100/ /700 P5

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

LED Driver Compact fixed output

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Ultra flat Pool & Spa LED light OWNER S MANUAL. Ultra flat shape 2 wire 12VAC ON/OFF control NoAir PAR56 Retrofit

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

Installation Guide VL-MV10. Model No.

Inductive sensor NI10-M18-Y1X-H1141

Linear flow controls VFC Linear flow controls with actuator IFC

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

E3/DS3 Fibre Extender

TRF STEP-DOWN TRANSFORMER USER MANUAL

Installation Guide. Cellular Plug-in for Inverters with SetApp. Version 1.1

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL


ercial the Features Product connectivity

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

LED STADIUM LIGHTING WS-STAD-xxx Gen6

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Litile34 OPERATION MANUAL

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

Guide for installers. METTLER TOLEDO MultiRange Explosion proof weighing system with IND226x weighing terminal.

Horn loudspeaker, Ex proof, short/long flare

PROPORTIONAL VALVES Sentronic plus

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

L-BAND over Fiber Link TX/RX. User Manual. L-1Ch-L-Band-TX/RX

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

DMP 331i / DMP 333i LMP 331 i

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Transcription:

108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2. Product s range 3. Technical data 4. Conformity with standards 5. Installation 6. Commissioning 7. Maintenance

108183 2017-05-17 Page 2 1. Safety instructions For skilled electricians and trained personnel in accordance with national legislation, including the relevant standards. Observe the national safety rules and regulations for prevention of accidents and the following safety instructions: - The light fitting must not be operated in any hazardous areas during installation! - The technical data indicated on the light fitting are to be observed! - Changes of the design and modifications to the light fitting are not permitted! - The light fitting shall be operated as intended and only in undamaged and perfect condition! 2. Product s Range: Description Power U range Ta Range FT3 Optic TPPL-EX-D100-L1700-8400LM-STD 90W 176V-276V = -20 C<Tamb<45 C 120 TPPL-EX-D100-L1700-8400LM-HB 90W 176V-276V = -20 C<Tamb<45 C 60 TPPL-EX-D100-L1200-5600LM-STD 60W 176V-276V = -20 C<Tamb<45 C 120 TPPL-EX-D100-L800-2800LM-STD 30W 176V-276V = -20 C<Tamb<45 C 120 TPPL-EX-D100-L800-2800LM-BW 30W 176V-276V = -20 C<Tamb<45 C 180 TPPL-EX-D100-FT3-L1700-8400LM-STD 90W 176V-276V = -20 C<Tamb<43 C 120 TPPL-EX-D100-FT3-L1700-8400LM-HB 90W 176V-276V = -20 C<Tamb<43 C 60 TPPL-EX-D100-FT3-L1200-5600LM-STD 60W 176V-276V = -20 C<Tamb<43 C 120 TPPL-EX-D100-FT3-L800-2800LM-BW 30W 176V-276V = -20 C<Tamb<43 C 120 TPPL-EX-D100-FT3-L800-2800LM-BW 30W 176V-276V = -20 C<Tamb<43 C 180 3. Technical data EC type examination certificate : Marking : Insulation class according to EN 60598: Degree of protection according to EN 60529: Supply terminal clamping capacity 2x per terminal: CE KIWA 15ATEX0042 X IECEx KIWA15.0023X II 2G Ex e ib mb IIC T5 Gb II 2D Ex tb ib mb IIIC T75 C Db IP66 I IP54 1.5 mm 2 to 2.5 mm 2, single- and multi-wire. Cable diam. 11-17mm

108183 2017-05-17 Page 3 Conductor cross-section with through-wiring: 3G2.5 mm 2 Cable entry standard version: Conductor device connector from WAGO 862-2633 series (certificate number: IECEx PTB 0.5.0003U) Test torque for cable entry: Test torque for pressure screw: Min: 6Nm - Max: 8Nm Min : 1Nm Max : 1.2Nm Do not tighten above this value otherwise you can damage the product 4. Conformity with standards The light fitting is suitable for use in zone 1 & 2 hazardous areas according to IEC/EN 60079-0:2011, IEC/EN 60079-7:2006, IEC/EN 60079-11:2011, IEC/EN 60079-18:2014, IEC/EN 60079-31:2013. It has been designed, manufactured and tested according to the state of art and according to IEC 80079-34:2011, ISO 9001:2015 and ISO 14001:2015. For installation steps please refer to IEC/EN 60079-14:2008 and any "local regulations and applicable standards". Any maintenance operation shall be executed according to IEC60079-17:2014. As a luminaire it complies with European low voltage, EMC, REACH, RED and ROhS directives and relevant standards of compliance. The RF frequency is 2411MHz at +4dBm power level. Hereby, DIETAL declares that the radio equipment type TPPL is in compliance with the Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address : http://www.dietal.com/wp-content/uploads/2017-03-14_02-eudeclaration-tppl-ex.pdf 5. Installation The respective national regulations as well as the general rules of engineering which apply to the installation and operation of such luminaires will have to be observed! Transport and storage of the luminaire is permitted in original packing and specified position only. 5.1 Mounting Warnings: X : The Luminaire shall be installed such that the risk of mechanical danger is low. The product is designed to be connected to a mesh network with wireless connectivity. The installation shall ensure that connectivity is not prevented by electromagnetics shielding effects (Faraday cage) Temperature sensitivity vs. position: note that for commissioning the temperature sensing on WCM depends on luminaire installation. We can have up to 5 C mismatch when the actual mounting orientation is different from the commissioning. The Luminaire shall be installed such that electrostatic charging and discharge is prevented during operation, maintenance and cleaning. The light fitting shall only be cleaned with a damp, nonfibrous cloth or sponge! Only use customary household washing-up liquid diluted in water! The water temperature may be max. 50 C. After that, rinse with clear water to prevent the risk of tension cracks in the protective bowl. Installation in places where conductive dust are on the go are not allowed (inside grain silo for example) Dimensions:

108183 2017-05-17 Page 4 Length "a" (mm) Ref. Stand alone "EC" Typical cable gland option Versions Feed-through option "EC" Typical cable gland option L800 782 825 801 888 L1200 1241 1284 1260 1347 L1700 1700 1743 1719 1806 There are 3 methods of mounting the product: 5.1.1 Directly to wall/ceiling surfaces with 2 ring brackets Fixing distances should be set as follows (b):

108183 2017-05-17 Page 5 2 status LEDs Length "b" (mm) Minimum Value Maximum Value L800 440 440 L1200 600 895 L1700 900 1355 Ref. Zebra area must remain bracket free The 2 status LEDs (green/red) shall be visible when ON through the diffusor from below to enable the commissioning of each luminaire and indicate luminaire status. 5.1.2 Using finger clip bracket, as a vertical fixing : 5.1.3 Using the lamp holder attachment as a suspension bracket to 42-48 mm tube : same bracket as 4.1.1 5.2 Opening and closing the light fitting The luminaire is sealed for life and therefore cannot be opened. The junction box only can be opened for mains wiring connection. This junction box must remain clean and dry. A particular attention must be paid to close it and tight the gasket according to the following specifications. 5.3 Mains wiring connection 5.3.1 Open junction box

108183 2017-05-17 Page 6 5.3.2 Pass wire through cable gland without tightening 5.3.3 Strip wire according to installation instruction (See wiring following diagrams, 10-11mm for copper) 5.3.4 Connect wires to connector (3 poles or 5 poles) 5.3.5 Close junction box (Torque 1-1.2Nm) - Ensure the red sealing ring is still in place 5.3.6 Tighten cable gland (Torque 6-8Nm) If through wiring, repeat the same operating instructions for the second junction box If not through wiring, ensure that Ex-stopping plug is tightened (Torque 6-8Nm) Please ensure that each live wire is connected to the relevant terminal in every connection boxes

108183 2017-05-17 Page 7 Check the cable gland gasket as follows: Wiring diagram with 3P/5P and through wiring 3P = See Wiring diagram TPPL Rev1.4.pdf When using multi- or fine-wire connection cables, the wire ends must be provided with wire end sleeves or cable lugs. Before closing the junction box, check that the rubber gasket is at its intended place. Finally close the junction box with screw torque. In case of metal cable gland you have to check that earthing is correctly linked to the terminal. 5.4 In-line connection Through wiring luminaires must be installed in accordance to national regulations and state of art. The Max. Current per wire is limited to 20A max. Please also ensure that circuit breakers are designed to suit to inrush currents. Max inrush current is 4A per driver for 500 µsec.

108183 2017-05-17 Page 8 5.5 Luminaire replacement LED engines are sealed for life and therefore cannot be replaced (lumen output 10% of nominal for EOL condition / indication is red light ON): luminaire shall be replaced. 6. Taking into operations Prior to operation, check the light fitting for its proper functioning and installation in compliance with these operating instructions and other applicable regulations! Only carry out insulation measurements between PE and the external conductor L1, as well as between PE and N. - Measuring voltage: max. 1 kv DC (TBD) - Measuring current: max. 10 ma (TBD) While taken into operation, the 2 colour LED indicators on each WCM module show the following status indication: - Green/Red blinking every 3 sec : not commissioned - 2 Green/1 Red blinking every 5 sec : Standalone mode under control - 2 Red/1 Green blinking every 5 sec : Standalone mode without network - Green blinking every 3 sec : power supply connected, lamp commissioned, normal operation - Green blinking every 5 sec : power supply in DC mode, power reduced to 25% - Red blinking every 3 sec : service is requested - Red blinking every 1.5 sec : TPPL error - Constant RED : EOL (End of Life) - Green/Red blinking every 1.5 sec : firmware upload - Green blinking every 1.5 sec : identification from the wireless network - Long green (>10sec) : Power start up on reset

108183 2017-05-17 Page 9 7. Maintenance IEC 60079-17 applies. Observe the national regulations applicable to the maintenance, servicing and test of apparatus, as well as the general rules of engineering! 7.1 Safety inspection No safety inspection is necessary (LED engines and power supply are maintenance free). Temperature, burning hours, efficiency and energy consumption are continuously monitored using the Wireless Control Module (WCM) interface. Any abnormal behaviour or function failures of any electrical component are directly accessible through Luminizer service platform. 7.2 Outside servicing The enclosure of this luminaire integrates specific polymer protection with UV blocker. This requires cleaning servicing depending on local level of air pollution in the direct environment of the luminaire. In case of cleaning service : - Check housing and junction box for any cracks or damages from external sources - The light fitting shall only be cleaned with a damp, non-fibrous cloth or sponge - Regular cleaning should be carried out depending on ambient pollution level to ensure a minimum loss in lighting transmission Only use customary household washing-up liquid diluted in water (max. water temperature = + 50 C). Then rinse with clear water. Please report to the manufacturer website to check the chemical compatibility if the product is exposed to chemicals that may damage the enclosure. 7.3 Failure Every luminaire is equipped with both green and red LED indicators operating differently in case of failure: - Red constant ON: lamp is in EndOfLife mode and is waiting for replacement - Red blinking in 1 sec on / 1 sec off : an error should be read out through In case of enclosure or end caps damaged by external impact, the luminaire needs immediate replacement. In any case, no repair will be allowed on the luminaire. 7.4 End of life recycling At the end of its life this luminaire is WEEE equipment and shall be recycled as an electronic device. 7.5 Repair: This luminaire shall not be repaired and must be replaced in case of failure.