Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

Similar documents
Understanding VFD. Variable Frequency Drive. nfi. nfi

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

RYKO Italia s.r.l. V. Casale Morano Po (Al) t f

AF-300 E11 Adjustable Frequency Drive

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

VAT 20 Adjustable Frequency Drive

2. Using LCD Digital Operator

RM5 User Manual Warnings.

DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER. For the DAAB EP104 automatic control system with software version 4.

ADJUSTABLE SPEED DRIVES. nc1 Drive

General Description. Specifications. 2.1 Electrical

Electronic Lineshaft With Alignment F7 Drive Software Technical Manual

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Definite Purpose Contactors

FS340 and FS641. High Performance Low Cost Controller for Flying Shears and Saws

HS-509 VIBRATION TRIP MODULE

M Traverse User Manual Revision F

AS09..S 3-pole Contactors - Spring Terminals

Your First Choice for Control Systems Solutions

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Series CT7N Bimetallic Overload Relays

Digital Ratio Controller

EA350. Generator Automatic Voltage Regulator Operation Manual

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

Inverters Selection Guide

ELCOM. Part Application Instruction. Release (V S 0.5) YS Kim S Jeong. OS Program Change to V S1.5 YS Kim S Jeong

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

High performance circuit breakers

Inverters Selection Guide

MILLITARY SPECIFICATION SHEET

EVC300i. Generator Automatic Voltage Regulator Operation Manual

Assembly. Front view. LEDs. Parametrization interface. Power Bus

EVC600i. Generator Automatic Voltage Regulator Operation Manual

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

02/11/2015

Bulletin 190 IEC Modular Starter System

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Operating Instructions for Throttle Valves Using VRC Valve Positioner

Single Axis Position Controller

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

GENMARK Engineering & Management # Street Edmonton, AB T5S 1R5 CANADA Phone (780) Fax (780)

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

llen-bradley 194R-HM4-NFPA3

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Single Axis Position Controller

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

Computer Controlled Advanced Industrial Servosystems Trainer (for AC motors) SERIN/CA

Dimming actuators GDA-4K KNX GDA-8K KNX

CT340 and CT641. High Performance Low Cost Controller for Rotating Cutters and Printing Rolls. Operating Instructions

Variable Speed Drives OMRON/YASKAWA F7Z - series

Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Model IQ4-PC User Manual Revision Date:

Selection guide siemens.com/sirius-modular-system

Automatic Transfer Switch Control PLC Operator s Manual

Operating instructions Electronic preset counter Type series 717

Bulletin 150, 154 Softstarters Quick Selection Table

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

with Simulated Outputs Description Applications Features

Contactors and Contactor Assemblies

Motion Control G7 Drive Software Technical Manual

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

USCG Exam questions related to PLCs by Frank Owen, Maine Maritime Academy, 23 October 2018

Label Applicator HERMA 400

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

INTRODUCTION INTRODUCTION

Type MG-6 Auxiliary Relay Class 1E

SQM40/41 Actuators for air and gas dampers

51109 Köln St. Asaph, Denbigshire LL17OLJ

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

SYSTEM DESCRIPTION 2.1 MAIN DISPLAY SCREEN 2.2 SYSTEM DIAGNOSTIC MENU 2.6 SETTING AND OPERATING INSTRUCTIONS 2.10 TO SET DEFAULT PARAMETERS 2.

Electronic M.O.P Card. Instruction Manual Model D

GAUGEMASTER PRODIGY EXPRESS

Kuhnke Technical Data. Contact Details

Ordering details. Approval. Classification

ADVR-053. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

Gamma instabus. Technical product information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

MICROMASTER Encoder Module

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

CAMTO LTD. Arc detecting system DC/AC

Atlas Drop In Decoder

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

Standard signal metering in wall-mounting case

Synchronization Check Relay ARGUS 7

MATE3 Owner s Manual Addendum

INSTALLATION & USER GUIDE

BE3-GPR GENERATOR PROTECTIVE RELAY

Transcription:

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive nfi

Practical Demonstration of VFD Motor Speed Directly Proportional to Frequency Motor RPM= (120*F)/P Powerflex- 4M 0.4 KW= 0.5 Hp I/P: 230V 1/3 Phase O/P: 230 3 Phase

Maximum Output Frequency Range 0 ~ 400 Hz

VFD Status Screen Command Freq. Volts reading Amperes Indicates freq. Control by VFD POT Motor RUN/Stop Indication Indicates Operation. Control by Keypad Direction RUN VFD Parameters STOP VFD Fault Keys to Read/Write Parameters Change Direction

Control Terminals Relay Feedback Terminals Freq. Feedback (0 ~ 10 V) (0 ~ 50Hz) Analog Current Input (4 ~ 20mA) Analog Voltage Input (0 ~ 10V)

Motor Output Terminals

3 Phase/ 1 Phase 220 VAC

VFD Wiring Diagram Power Flex 4M Parameters to be used in this Course

How to? Reset the Drive & Enter Start-up Parameters nfi

AB Powerflex 4M Programming the VFD Step 1: Reset the Drive to Factory Setting Parameter: P112 Reset to Default Resets all parameter values to factory defaults.

AB Powerflex 4M Step 2: Enter Motor related Parameters P101 Motor NP Voltage Stop drive before changing this parameter. Set to the motor nameplate rated voltage. P102 Motor NP Hertz Stop drive before changing this parameter. Set to the motor nameplate rated frequency. P103 Motor OL Current Set to the maximum allowable motor current. P104 Minimum Frequency Sets the lowest frequency the drive will output continuously. Min/Max: 0.0/400.0 Hz P105 Maximum Frequency Sets the highest frequency the drive will output continuously. Min/Max: 0.0/400.0 Hz

Keypad Source of Operation nfi

AB Powerflex 4M Source of Operation P106 Start Source Stop drive before changing this parameter. Sets the control scheme used to start the drive.

3 Wire Source of Operation nfi

AB Powerflex 4M Source of Operation P106 Start Source Stop drive before changing this parameter. Sets the control scheme used to start the drive.

2 Wire Source of Operation nfi

AB Powerflex 4M Source of Operation P106 Start Source Stop drive before changing this parameter. Sets the control scheme used to start the drive.

AB Powerflex 4M Stop Method P107 Stop Mode Active stop mode for all stop sources 0 Ramp, CF (1) (Default) P110 Dec. Time Ramp to Stop. Stop command clears active fault. 1 Coast, CF (1) Coast to Stop. Stop command clears active fault.

Drive Pot Source of Speed nfi

AB Powerflex 4M Parameter Organization - Program P108 Speed Reference Sets the source of the speed reference to the drive.

Internal Freq. Source of Speed nfi

AB Powerflex 4M Parameter Organization - Program P108 Speed Reference Sets the source of the speed reference to the drive.

0 ~ 10 VIN Source of Speed nfi

AB Powerflex 4M Parameter Organization - Program P108 Speed Reference Sets the source of the speed reference to the drive.

Preset Freq. Source of Speed nfi

AB Powerflex 4M Parameter Organization - Program P108 Speed Reference Sets the source of the speed reference to the drive. DIN 2 DIN 1 Speed Parameter Speed (in Hz) 0 0 A410 10 Hz 0 1 A411 5 Hz 1 0 A412 15 Hz 1 1 A413 20Hz

Acc./Dec. Time nfi

Acc./ Dec. P109 Acc. Time Sets the rate of deceleration for all speed decreases. AB Powerflex 4M P110 Dec. Time Sets the rate of deceleration for all speed decreases.

Acc./Dec. Time 2 nfi

AB Powerflex 4M Acc./ Dec. 2 Step 1- Enter the Time Default Acc./Dec. Time Acc./Dec. Time 2 P109 Acc. Time Sets the rate of acceleration (0 ~ 600secs). A401 Acc. Time 2 Sets the rate of acceleration (0 ~ 600secs). P110 Dec. Time Sets the rate of deceleration (0.1 ~ 600secs). A402 Dec. Time Sets the rate of deceleration. (0.1 ~ 600secs) Step 2- Assign the Function T201/T202 DIN Function Enter 1 for Acc./Dec. Time 2 Step 3- Energize DIN 1/DIN 2

JOG Mode nfi

AB Powerflex 4M Jog/Inch Frequency To adjust the Speed of Motor at Jog Mode Jog Acc./ Dec Time Step 2- Assign the Function T201/T202 DIN Function Enter 2 for Jog Mode Step 3- Energize DIN 1/DIN 2 0.1 to 600.0 sec or 0.01 to 600.0 sec Step 1- Enter the Jog Freq., Acc./Dec. Time A404- Jog Freq. A405- Jog Acc./Dec. Time

Local Control nfi

AB Powerflex 4M Local Control When active, sets integral keypad as start source and potentiometer on the integral keypad as speed source Step 1- Assign the Function T201/T202 DIN Function Enter 5 for Local Operation Step 2- Energize DIN 1/DIN 2 Speed Source Operation Source

Aux Fault nfi

AB Powerflex 4M Aux Fault- NC When enabled, an F2 Auxiliary Input fault will occur when the input is removed. Step 1- Assign the Function Step 2- Energize DIN 1 To include fault T201 DIN Function Enter 3 for Aux Fault Clear Fault- NO When active, clears an active fault. Step 1- Assign the Function Step 2- Energize DIN 2 T202 DIN Function To clear the fault Enter 7 for Clear Fault

Override 0 ~ 10 VIN Source of Speed nfi

AB Powerflex 4M Override 0 ~ 10VIN Selects 0-10V or ±10V control as the frequency reference. Start source is not changed. Step 1- Assign the Function Step 2- Energize DIN 1/DIN 2 To override 0 ~ 10V Source T201/T202 DIN Function Enter 13 for 0 ~ 10VIN

VFD Scaling Adjusting Voltage by Frequency Curves

www.nfiautomation.org VFD Scaling P105 Max. Freq. (0 ~ 400Hz) 50 Hz 1 Volt =5Hz 25 Hz P104 Min. Freq. 0 Hz (0 ~ 400 Hz) T211 = 0% (default) Range 0 ~ 100% 0V 5V 10V t211 Min. Volts t212 Max. Volts T212 = 100% (default) Range 0 ~ 100%

www.nfiautomation.org VFD Scaling P105 Max. Freq. (0 ~ 400Hz) 50 Hz 20 Hz P104 Min. Freq. (10 Hz) 10 Hz T211 = 0% (default) Range 0 ~ 100% 0V 5V 10V t211 Min. Volts t212 Max. Volts T212 = 100% (default) Range 0 ~ 100%

www.nfiautomation.org VFD Scaling Scaling Value = Bias Voltage/Full Voltage x 100 = 1/10 x 100 = 10% P105 Max. Freq. (0 ~ 400Hz) 50 Hz 25 Hz P104 Min. Freq. (0 ~ 400 Hz) 0 Hz 1V 4.5V 10V t211 Min. Volts T211 = 10% Range 0 ~ 100% t212 Max. Volts T212 = 100% (default) Range 0 ~ 100%

www.nfiautomation.org VFD Scaling Scaling Value = Bias Voltage/Full Voltage x 100 = 5/10 x 100 = 50% P105 Max. Freq. (0 ~ 400Hz) 50 Hz 25 Hz P104 Min. Freq. (0 ~ 400 Hz) 0 Hz 5V t211 Min. Volts T211 = 50% Range 0 ~ 100% 7.5V 10V t212 Max. Volts T212 = 100% (default) Range 0 ~ 100%

www.nfiautomation.org VFD Scaling P105 Max. Freq. (0 ~ 400Hz) 50 Hz P104 Min. Freq. (0 ~ 400 Hz) 25 Hz 0 Hz 0V t211 Min. Volts 2.5V T211 = 0% Range 0 ~ 100% 5V t212 Max. Volts Scaling Value = (Full voltage - Bias Voltage)/Full Voltage x 100 = (10-5/10 x 100 = 50% T212 = 50% Range 0 ~ 100%

www.nfiautomation.org VFD Scaling P105 Max. Freq. (0 ~ 400Hz) 50 Hz Scaling Value = Bias Voltage/Full Voltage x 100 = 2.5/10 x 100 = 25% 25 Hz Scaling Value = (Full voltage - Bias Voltage)/Full Voltage x 100 = (10-2.5/10 x 100 = 75% P104 Min. Freq. (0 ~ 400 Hz) 0 Hz t211 Min. Volts T211 = 25% Range 0 ~ 100% 2.5V 5V 7.5V t212 Max. Volts T212 = 75% Range 0 ~ 100%

www.nfiautomation.org VFD Scaling P105 Max. Freq. (0 ~ 400Hz) 50 Hz Scaling Value = Bias Voltage/Full Voltage x 100 = 5/10 x 100 = 50% P104 Min. Freq. (0 ~ 400 Hz) 25 Hz Scaling Value = (Full voltage - Bias Voltage)/Full Voltage x 100 = (10-2.5/10 x 100 = 75% 0 Hz t211 Min. Volts T211 = 50% Range 0 ~ 100% 5V 7.5V t212 Max. Volts T212 = 75% Range 0 ~ 100%

Feedback Signals nfi

Feedback Relay Type Related Parameter: t221 & t222 Sets the condition that changes the state of the output relay contacts. Sets the trip point for the digital output relay if the value of t221 [Relay Out Sel] is 6, 7, 8, 10 or 11. 1. VFD Operation Run & Stop t221 =2 2. VFD Running Reverse t221 = 3 3. VFD Desired Frequency Attained t221= 6 t222 = Frequency

PLC & VFD Advanced Course 4 PLC s Training Platforms $149 Course Highlights: Course Link: http://nfiautomation.org/special-offers/ 30 Live Practical Classes on PLC, Analog Cards & AC drives- VFD 100+ PLC Video Tutorials with Lifetime Access & FREE PLC Simulator FREE Circuits Diagram For more courses visit www.nfiautomation.org

Thank You nfi