UNCLASSIFIED AD DEFENSE DOCUMENTATION CENTER FOR SCIENTIFIC AND TECHNICAL INFORMATION VIRGINIA CAMERON STATION, A..EXANDRIA, UNCLASSIFIED

Similar documents
CATHODE-RAY OSCILLOSCOPE (CRO)

This work was supported by FINEP (Research and Projects Financing) under contract

CATHODE RAY OSCILLOSCOPE (CRO)

CHAPTER 4 OSCILLOSCOPES

The Knowledge Bank at The Ohio State University. Ohio State Engineer

Teltron Delection Tube D

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

3B SCIENTIFIC PHYSICS

These tests will be repeated for different anode positions. Radiofrequency interaction measurements will be made subsequently. A.

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

Lecture 17 Microwave Tubes: Part I

The Cathode Ray Tube

CNT FIELD EMISSION CATHODE CATALOG. XinRay Systems Inc. April 2014

THE OPERATION OF A CATHODE RAY TUBE

Improvements in Gridless Ion Source Performance

IMPROVEMENTS IN LOW POWER, END-WINDOW, TRANSMISSION-TARGET X-RAY TUBES

3B SCIENTIFIC PHYSICS

THE OPERATION OF A CATHODE RAY TUBE

TRANSVERSE-VELOCITY DISTRIBUTION FOR SPACE-CHARGE-LIMITED BEAM CURRENT IN AN ELECTRON GUN WITH ROTATIONAL SYMMETRY

Particle-in-cell simulation study of PCE-gun for different hollow cathode aperture sizes

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

Effect on Beam Current on varying the parameters of BFE and Control Anode of a TWT Electron Gun

TOSHIBA Industrial Magnetron E3328

Sep 09, APPLICATION NOTE 1193 Electronic Displays Comparison

APPARATUS FOR GENERATING FUSION REACTIONS

Principles of Electrostatic Chucks 6 Rf Chuck Edge Design

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

Mechanical aspects, FEA validation and geometry optimization

Development of Multiple Beam Guns for High Power RF Sources for Accelerators and Colliders

Defense Technical Information Center Compilation Part Notice

These are used for producing a narrow and sharply focus beam of electrons.

Hollow Cathode and Thruster Discharge Chamber Plasma Measurements Using High-Speed Scanning Probes

High QE Photocathodes lifetime and dark current investigation

B. TECH. VI SEM. I MID TERM EXAMINATION 2018

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

SECTION I INTRODUCTION

In the tube collection there are several sensors designed for applications in some kinds of physics measurements or detection.

FIR Center Report. Development of Feedback Control Scheme for the Stabilization of Gyrotron Output Power

Klystron Tubes. Two forms of such a device, also called linear beam klystron, are given in the following figure.

Analog Circuits Prof. Nagendra Krishnapura Department of Electrical Engineering Indian Institute of Technology, Madras. Module - 04 Lecture 12

TEST RESULTS OF THE 84 GHZ / 200 KW / CW GYROTRON

CHAPTER 3 OSCILLOSCOPES AND SIGNAL GENERATOR

P-224: Damage-Free Cathode Coating Process for OLEDs

Svetlana 3CX10,000A7/8160

RF Power Generation II

High-Current Hollow Cathode Development *

Light Emitting Diodes (LEDs)

V. MICROWAVE ELECTRONICS*

THE DESIGN OF A LEAD-BISMUTH TARGET SYSTEM WITH A DUAL INJECTION TUBE

Optimization of a triode-type cusp electron gun for a W-band gyro-twa

INSTRUMENT CATHODE-RAY TUBE

Detailed Design Report

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, CATHODE RAY TYPE 7AGP19

Display Systems. Viewing Images Rochester Institute of Technology

INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

Elements of a Television System

Computer Graphics Hardware

Quality produced by means of electron beam

NEXT ION OPTICS SIMULATION VIA ffx

Operating Experience and Reliability Improvements on the 5 kw CW Klystron at Jefferson Lab

INSTRUMENT CATHODE-RAY TUBE

If you are using a CRT tester/restorer other than the CR7000 you are likely incorrectly testing today s CRTs and risk damaging every one you restore.

STUDIES OF ENHANCED EDGE EMISSION OF A LARGE AREA CATHODE *

4.9 BEAM BLANKING AND PULSING OPTIONS

OSCILLOSCOPE AND DIGITAL MULTIMETER

Direct Measurements of Plasma Properties nearby a Hollow Cathode Using a High Speed Electrostatic Probe

About vacuum power tubes.

Low-Noise, High-Efficiency and High-Quality Magnetron for Microwave Oven

Performance Characteristics of Steady-State MPD Thrusters with Permanent Magnets and Multi Hollow Cathodes for Manned Mars Exploration

A quick and dirty magnet design for the magnetized beam LDRD proposal Jay Benesch 10/16/2015

Triggered breakdown in lowpressure hollow cathode (pseudospark) discharges

CR7000. CRT Analyzer & Restorer. Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security.

LED modules for illuminated signs Opto Semiconductors

2.2. VIDEO DISPLAY DEVICES

Thyratrons. High Energy Switches. Features. Description

CHAPTER 9. Actives Devices: Diodes, Transistors,Tubes

Development of high power gyrotron and EC technologies for ITER

A STUDY OF CATHODE EDGE EMISSION* Yong-xiang Zhao Stanford Linear Accelerator Center Stanford University, Stanford, California ABSTRACT

KLYSTRON GUN ARCING AND MODULATOR PROTECTION

MODE FIELD DIAMETER AND EFFECTIVE AREA MEASUREMENT OF DISPERSION COMPENSATION OPTICAL DEVICES

A tapered multi-gap multi-aperture pseudospark-sourced electron gun based X-band slow wave oscillator

Development of OLED Lighting Applications Using Phosphorescent Emission System

Experimental Results of the Coaxial Multipactor Experiment. T.P. Graves, B. LaBombard, S.J. Wukitch, I.H. Hutchinson PSFC-MIT

PRACTICAL APPLICATIONS OF ELECTRONICS IN ANAESTHESIA. G. A. HAY Department of Medical Physics, University of Leeds

Physics of high-current diode

Overview of All Pixel Circuits for Active Matrix Organic Light Emitting Diode (AMOLED)

Reading 21 ELECTRON TUBES

Investigation and study on Cathode operating point of SPACE TWTs

KDC 10 DC ION SOURCE MANUAL WITH 1 CM TWO-GRID GRAPHITE OPTICS

decodes it along with the normal intensity signal, to determine how to modulate the three colour beams.

THE CARE AND FEEDING OF CROWBAR THYRATRONS

2x1 prototype plasma-electrode Pockels cell (PEPC) for the National Ignition Facility

It s important to stand out from the crowd.

THE X-RAY ADVANTAGE Pros and cons X-ray and Gamma

CPI Gyrotrons For Fusion EC Heating

Electrical & Electronic Measurements: Class Notes (15EE36) Module-5. Display Devices

CHAPTER 4: HIGH ENERGY X-RAY GENERATORS: LINEAR ACCELERATORS. Jason Matney, MS, PhD

4617 Super Power Triode

Transcription:

UNCLASSIFIED AD 405 695 DEFENSE DOCUMENTATION CENTER FOR SCIENTIFIC AND TECHNICAL INFORMATION CAMERON STATION, A..EXANDRIA, VIRGINIA UNCLASSIFIED

FD-T1-63_367,/1+2+4 UNEDITED ROUGH DRAFT TRANSLATION STUDY OF THERMAL ELECTRON EMISSION FROM A HOLLOW CATHODE By: M. B. Pyttyeva and Ye. M. Dubinina English Pages: 12 Source: Russian periodical, Izvestiya akademii nauk SSSR, Seriya fizicheskaya Vol. 26, No. 11, 1962, pp. 1343-1348. T-74 sov/48-62-26-11- THIS TRANSLATION IS A RENDITION OP ihe ORIGI. NAL FOREIGN TEXT WITHOUT ANY ANALYTICAL OR EDITORIAL COLMENT. STATEMENTS OR THEORIES ADVOCATED 02 NZP LIED ARE THOSE OF TIHE SOURCE ANODO HOT N2CESSARILY REFLECT THE POSITION OR OPINION OF THE FOREIGN TECHNOLOGY DI- VISION. PREPARED STl TRANSLATION SERVICES BRANCH FOREIGH TECHNOLOGY DIVISION WP.APS, OHIO. FTD-TT 63-367/1+2+4 Dale 13 May 19 63 P

STUDY OF THERMAL ELECTRON EMISSION FROM A HOLLOW CATHODE M. B. Pyttyeva and Ye. M. Dubinina Introduction The great interest in hollow oxide cathodes which has again been noted recently [1, 2] has been brought on by the considerable current densities of cathode emission, by the low voltages at which they may be obtained, ds well as by the small effective dimensions of the electron source and the insensitivity of the cathode to ionic bombardment [3]. However, the mechanism of its emission has not yet been sufficiently studied; visual investigation of the structure of the beam formed by a system with a hollow cathode attest,- to its complexity. An attempt has been made to explain current anomalies of the cathode on the basis of the structural characteristics of the beam. Thus we assumed the presence of two components, in the current from a hollow cathode, which may be separated by a strong longitudinal magnetic field [I]. FrD-TT-63-367/1+2+4-1-

I. Investigation of the Structure of the Beam 1. Design of the Test System Figure I shows the gun with the hollow cathode whose beam was studied in the given work. Cathode K is a closed cylindrical cavity coated on the inside with oxide paste. Anode A and accelerating electrode B are diaphrams made of hollow tungsten mesh. The introduction of the accelerating electrode B is required by the method of investigation used. The distance between the anode and cathode is 3: 2. Test Method The distribution of current density in the beam was determined from an oscillogram of the probe current (Fig. 2). A long thin metal probe P was placed in the path of the electron beam and periodically intersected the electron beam normal to the direction of its motion [5]. The magnitude of the current reaching the probe at any given moment may be calculated from the equation -- 2(1 (r)rarc cos -"dr (1) Here a is the coefficient of secondary probe emission, 6 is the thickness of the probe, and ro is the coordinate of the position of the probe. Determination of the current density J(r) thus involves solution of integral equation (1), this solution may be obtained with sufficient accuravy by the approximation method used in this work. FlD-TT-63-367/1+2+4-2-

3. Distribution of Current Density in a Cross Section of the Beam over the Ran~e or Anode Voltages from 50 to 1000 Volts. Figure 3 shows the form of a typical oscillogram of the current and its associated current-density distribution in the cross section of the electron beam. It was noted that there was a significant variation in current density distribution in the beam with a variation in drawing potential. The results of the treatment of the oscillograms may be sunmmarized as follows. For low anode voltages (from 50 to 100 volts) the picture of the distribution of current in the cross-section of the beam (Fig. 4a) corresponds to an almost hollow beam. An increase in the potential within this range simply causes an increase in current density in the hollow beam and a slight expansion of the ring in the cross section, mainly on account of a reduction of the radius of the inner boundary of the ring. The development of the field, which corresponds to the variation of the anode voltage above 100 volts (Fig. 4b) also produces an increase in current density in the more central portions of the electron beam, while the change in current density in the ring section of the beam, beginning with 150 volts, slows down. As the potential increases, the boundary region, with current density which is constant with respect to voltage, advances along the radius toward the center. At 260 volts there is a relative maximum current density at the center of the cross section of the beam (Fig. 4c) which at 500 volts anode potential already significantly exceeds the magnitude of the maximum current density at the edge of the beam (Fig. 4d). It should be noted that when the voltage was increased and the diameter of the beam varied, no other geometric characteristics of structure were observed. This indicates an insignificant angular FTD-TT-63-367/1+2+4-3-

scattering of electrons flying from the cathode opening. 4. Structure of the Cross Section of the Electron Beam as a Function of the Degree of Heating or Mthe CatMode It is inconvenient to characterize the degree of heating of a hollow cathode by its temperature, since the latter is not uniform for different sections of the surface of the cathode. Therefore, for convenience,, we will use as such a characteristic the filament power of the heater or the filament voltage. Figure 5 shows the nature of the distribution of current density in the cross section of the electron beam for cases of varying degrees of cathode heating. low temperatures corresponding to a filament power of 6.4 watts the electron beam appears as a narrow compact cylindrical ray. At Heating the cathode causes an increase in the diameter of the electron beam while the current density in the central regions of the cross section does not change. The boundary of the region which has a current density that does not change with temperature moves, with increasing temperature, from the center along the radius, and the diameter continues to increase. With a filament power of 13.6 watts a relative maximum current density appears at the edge of the beam and increases,as it moves along the radius away from the center (Figs. 5c,5d). increase in filament power above 20.4 watts does not alter the distribution of current density in the beam. 5. Structure of the Beam When Altering the Vacuum All of the experiments described above were conducted at a pressure of 5 1 I0- to 1 10-7 mm. To investigate operation of the cathode under varying vacuums conditions we analyzed probe-current," oscillograms with increasing residual-gas pressure. An -4--

Up to a pressure of 1 10"4 um neither the form of the oscillogram nor the absolute magnitude of the current underwent any changes. A subsequent increase in pressure causes a variation of the outer, most distant from the axis, regions of the electron beam. The current density in these regions decreased, the beam contracted without significant changes in the near-axis regions. The character of the variation of curxient density in the cross section of the beam in this case resembles the corresponding variation in current density with a reduction of cathode temperature. This similarity may apparently be explained by the increased heat transfer caused by the decrease in vacuum. Therefore, in order to separate the cathode contamination effect from the thermal effect, it is necessary to control the temperature of the cathode, keeping it constant. In the present work such a possibility was not provided for. II. Certain Observations Relative to the Mechanism of Emission from a Hollow Cathode We will use the "3/2 law" for a flat diode in pure form in the case of zero initial electron velocities. Calculation of the Maxwellian distribution of thermal electrons with respect to velocities led, for a flat diode, to the formula (d-da, (2 where Vmin and dmin are the magnitude of minimum potential and the corresponding position of the virtual cathode, respectively. Thus we will use the "3/2 law" for the case rvhen the surface of the virtual cathode coincides with the emitting surface. This occurs for the majority of known cathode geometries, and therefore this law is practically satisfied. The hollow cathode has a very large space "-5-

charge. Therefore, before the surface or the virtual cathode draws near the emitting surface, Vmin and dmin pass through a large range of values. The "3/2 law" can hardly be expected to be satisfied in view of this fact alone. In addition, the various parts of the surface of the cathode are located at such varied positions with respect to the anode that the quantities Vmin and dmin will vary differently in different directions. This leads to the fact that the surface of the virtual cathode and the distribution of the potential on it will vary significantly with voltage and the distribution of beam electrons with respect to velocity depends on this fact. Therefore there is no basis for expecting that'the current of a hollow cathode will vary from the magnitude of the applied voltage according to the "3/2 law." The real volt-ampere characteristic of a hollow cathode may be explained in the following way. In the presence of weak drawing fields, as long as the virtual cathode is located in the aperture, the volt -ampere characteristic is described by the Langmuir law. According to the degree of drawing-off of the space charge, the current from the portions of the aperture closest to the anode are saturated. The edge of the region of saturation migrates with the voltage along the surface of the cathode, embracing the surface of the edge of the aperture (on which, during operation of the cathode, a microcrystalline oxide deposit is forimd) and, the regions of the upper base of the cavity near the aperture. Here the virtual cathode migrates into the cavity; its form changes, seeking to coincide with the form of the cathode cavity. This establishes a more intense moving away of the central portions of the virtual cathode from the anode (the case of a cylindrical canity -6-

the height greater than the diameter). Therefore, the external por"' tions of the electron flux consisting of electrons emitted from the upper base of the cathode cavity make the basic contribution to the current, which explains the formation of an almost hollow beaim at low voltages. Passing into the cavity, the electrical field also draws off electrons emitted from the lateral walls. If the current from the edges of the aperture and the regions adjacent to it form an outer dense ring in the cross section of the beam, then the parts of the upper bae more distant from the aperture are responsible for the inner parts of the electron flux. Finally, the maximum density at the center is produced by emission from the lateral walls (Fig. 6) Thermal regularities reflect the fact that the various parts of the cathode surface are at different temperatures; in particular, the regions which are immediately adjacent to the aperture have the lowest temperature. III. Volt-Ampere Characteristics of a Hollow Cathode at Auiio FreQuencies The purpose of this study was to clarify the inertia properties of the hollow cathode and also to examine the volt-ampere character-. istics for hysteresis. Figure 7 shows the circuit for recording dynamic characteristics of the system. Varying the frequency of the anode voltage from 20 to 2000 cps has no influence on the volt-ampere characteristics of the diode. According to the form of the volt-ampere oharaotewistio, owing to the rather abrupt variation of it slope, the rise of an unstable condition in the system which hysteresis usually accompanies may be doubted. However, the volt-ampere characteristics of the diode with a hollow --7-

cathode, recorded with direct and reverse variation of voltage, practically coincide, which testified to the absence of hysteresis properties in the test circuit. IV. Volt-AmPere Characteristics of the Hollow Cathode for Various Temperatures and Distances Between the Cathode and Anode For greater accuracy, a circuit analogous to the one in Fig. 7 was used in this case to record characteristics. Figure 8 shows the family of volt-ampere characteristics obtained for different heating of the cathode. It can be seen from the figure that for weak drawing fields the current from the hollow cathode is determined by the space charge. Moreover, for volt-ampere characteristics corresponding to a higher cathode temperature, the voltage range at which the current is determined by the space charge naturally increases. Figure 9 shows the family of volt-ampere characteristics with the distance between the cathode and anode serving as the parameter and varying from 0.5 to 13 mm. The current-stopping properties of a longitudinal magnetic field.were also studied. It was established that current emitted from various sections of the surface of the cathode are cut off differently. Consequently, it is not possible in this way to separate completely the current emitted, let us say, by the edge of the aperture, from the current from within the cavity. Conclusions 1. Electrons after emergence from the aperature possess little scattering with respect to velocity. -8-

2. The edge of the beam originates at the edge of the apertuwej the inner parts of the beam originate from the emission of the sections of the surface of the upper base of the cavity more distant from the aperture; the central parts originate from the lateral surfaces (see Fig. 6). 3. When anode voltages exceed 260 volts, emission from the edge of the aperture is saturated. 4. Within the range of voltages studied (50 9 VA 9 1000 v) the current from the regions of the upper base of the cathode cavity located at a distance from the aperture greater than the radius of the aperture, and the current from the lateral surface, are bounded by a space charge. 5. The saturation of current from the regions indicated does not proceed at the same time. The boundary of the region of saturation migrates. 6. Variation of the geometric parameters of the cavity, namely its shape and the relationship of the dimensions, may produce a certain change in the structure of the beam. We express our thanks to G. V. Spivak for his interest in the work and for a number of valuable suggestions and to Huang Kao-nien for his practical help in conducting the experiment. Physics Dept; Lomonosov Moscow State University -9-

N-- IP S ~4070 FI. 1. Test gun with hollow Fig. 2. E.perimental tube and cathode: A) anode- B) acceler- electrical circuit; S) eleotrn ating electrode; CS cold cath- gun with hollow cathode; P) ode; K) cathode; H) heater, probe; K) eleetron collector3 0) oscilloscope. I. raw Fig. 3. Typical oscillogzam of Fig. 4. Distribution of probe current (a); distribu- current density over the ra44ýa tion of current density over the of the beam vs. anode vo!taspt radius of the beam (b). a) VA - 75v; b) VA', - I c) VA - 50OV; d) VA - 1oOov.,,.,T,63,367/1++ -10-

r im A 7 Fig. 5. Distribution of Fig. 6. Formation of electron current density along the beam flux from~ a hollow cathode, radius vs. the degree of heating of the cathode. Filament power: a) 6.14 watts; b) 11.9 w; c) 13.6 w; d) 20.41 w. Fig. 7. Electrical circuit for recording volt-ampere characteristics of a hollow cathode: T) test diode; 0) vertical plates of oscilloscope. PTD-T-63-.367/l+2+4-11-

248,., "'VA S60 /it Jr. 00 Y. V Fig. 8. Volt-ampere char- Fig. 9. Volt-ampere characteracteristics for different istics for various distances heating of the cathode (param- between the cathode and anode. eter - heater voltage). su REFMENCES 1. A. Sandors. Proc. Inst. Electr. Engre, B 108, 37, 90 (1961). 2. M. B. Pyt'yeva and Ye. M. Dubinina. Radiotekhnika i elektronika, No., Up12ol, 19b0. 3. J. Pierce. Voprosy radiolokatsionnoy tekhniki, No. 4,-52, 1955. I. K. M. Poole. J. Appl. Phys., 26, No. 9, 1176 (1955). 5. I. K. Ovchinnokov. Ukr. fiz. zh., 4, No. 2, 226, 1959.."bI',, }..S633/1+24. -.12-

DISTRIBUTION LIST *DEPARIM4T OF DFU=SE Hr. Copies MAJOR AIR OOW4A3DS, Nr. Copi6 i AFPSC SCFDD I DDC 25 IMADQUARTERS UISAF TDBTL 5 TDBDP 5 AFCIN-3D2 1AEDO (AZ!)1 ARL (ARD) I AFMTC (M'TW) 1 APdL (WLF) 1 APGC (PGY) 1 ASD (AS7IM1) 2 OTHER AGENCIES EMD (ES!).1 RADC (RAY) 1 CIA 1SSD (SSF) 2 NSA TDKPA (Smith) 1 DIA 9 AID 2 'OTS 2 AEC 2 Pws 1 NASA I ARMY (78Tc) NAVY 3 NAI~fC 1 AFCRL (CRn 5 R) 1 PGZ 12 RAND 1 FTD-TT'.63-3fn/10+4 13