Actuators IC 20, IC 30, IC 50

Similar documents
Linear flow controls VFC Linear flow controls with actuator IFC

Actuators IC 20, IC 40

Linear flow control with actuator IFC

SQM40/41 Actuators for air and gas dampers

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

02/11/2015

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Assembly. Front view. LEDs. Parametrization interface. Power Bus

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Datasheet - SRB301LC 24VAC/DC

Type: DILM25 10(24V50HZ) Article No.:

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Type: DILM12 10(24VDC) Article No.:

Ordering details. Approval. Classification

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

MICROMASTER Encoder Module

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Absolute Rotary Encoder E6CP

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Minicontactorrelay,2NO/2NC,DCoperated

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Kuhnke Technical Data. Contact Details

Model Number Structure

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

Part-Turn Electric Multi-Turn Electric

Capacitance Limit Detection nivotester FTC 420/421/422

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

LED Driver Linear / area fixed output

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

IMPAC Infrared Thermometers

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Lt DELTA USA, Inc

Figure 1: Device components

LED control gear Compact fixed output

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Datasheet - SRB-E-201ST

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

800 Displaying Series Flowmeter

Photoelectrics Through-beam Type PA18C.T..., DC

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

LED Driver Compact fixed output

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Sensor technologies Proximity sensors Series ST4. Brochure

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

AS09..S 3-pole Contactors - Spring Terminals

Standard signal metering in wall-mounting case

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Safety Light Curtains GuardShield

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

DLP200M 2 Relay Module for Heating and Cooling Plants

LED Driver Compact fixed output

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Panel-mounting thermostats, type series EM

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LAUREL ELECTRONICS, INC.

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual


Modular Lube Lubrication Systems System Controls

Level Measurement silometer FMC 420, FMC 423

PROPORTIONAL VALVES Sentronic plus

LED Driver Compact dimming

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Electronic Pulse Counter Combination device

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Emergency lighting units EM powerled

Magnecraft Power Relays

LUT Luminescence scanners: Seeing what no-one else can

Mechanical flow switch for On/Off control

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Process Transmitter RMA 422

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

SAFETY TERMS AND SYMBOLS

Emergency lighting units EM powerled

DATA SHEET Panorama Rudder Indicator, TRI-2

Series CT7N Bimetallic Overload Relays

GRUNDFOS ALLDOS DATA BOOKLET DDI DIGITAL DOSING

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

Transcription:

Actuators, IC 30, Product brochure GB 3 Edition 02.16 Easy to switch between Automatic and anual mode Position indicator that can be read externally Three-point step control..e and..e also for continuous control..e,..e with electronic positioning function for high torques and with selectable direction of rotation IC 30 for 24 V DC and can be delivered ready installed on control element, : adjustable motor behaviour in the event of cable discontinuity, for example

2, IC 30, Edition 02.16 Applications IC 30 Application The actuators are designed for all applications that require precise, controlled rotary movement between 0 and 90. In In conjunction with a control element, they are suitable for regulating flow rates on gas and air appliances for modulating or stagecontrolled combustion processes. In addition to setting the in. and ax. positions using infinitely adjustable switching cams, floating limit switches mean that additional switching positions such as for ignition and high-fire rate positions can be set. A standard Service switch allows the device to be switched from Automatic to anual mode and a position indicator which can be read from the outside drastically simplifies the commissioning procedure., IC 30 and are controlled by a three-point step signal...e and..e can also be controlled by a continuous signal. An integrated feedback potentiometer offers the option of monitoring the current position of the actuator. This checking function can be used in automation processes...e,..e The behaviour of the actuator, e.g. if the input signal falls below the minimum limit in the event of cable discontinuity, can be set using DIP switches. Fluctuations or interference in the input signal are suppressed by an adjustable potentiometer. In the case of continuous control, the input signal can be adapted to the minimum and maximum adjustment angles manually or automatically. This calibration process can be visualized using LEDs. The continuous signal offers the option of monitoring the current position of the actuator. Roller hearth kiln in the ceramics industry Forging furnace CHP for generating electricity and heat

, IC 30, Edition 02.16 3 The actuator can be mounted directly onto the butterfly valves BVG, BVGF, BVA, BVAF, BVH or BVHS. The combination is designed for control ratios up to 10:1. Axial mounting IBG ( + BVG) Actuator and linear flow control VFC can be delivered ready assembled. The combination is designed for control ratios up to 25:1. IDR..AU IDR..AS The actuator is axially aligned to butterfly valve DKR and can be mounted rotated in increments of 90. The connections are then positioned above the pipe or to the side of the pipe. Attachment with linkage If the actuator is to be operated offset to the side of the butterfly valve, an attachment set with linkage can be used. The actuator may be installed rotated by 180. IFC ( + VFC) IC 30 Actuator IC 30 is used as an actuator for linear flow control VFC. An adapter set must be used for assembly. The IC 30, linear flow control VFC and the adapter set are not assembled on delivery. This combination is designed for a control ratio of up to 25:1. IC 30 is suitable for 24 V DC applications. IDR..GD This attachment set..gd is used for butterfly valves with disc clearance DKR..D. IC 30 + VFC is designed for applications with high torques of up to 30 Nm. Actuator and butterfly valve DKR are also delivered ready assembled up to nominal size 300. The direction of rotation of the valve disc can be switched. The valve disc position can be read from the outside whereby the direction of rotation is indicated using a colour code. Depending on the application, the actuator can be aligned to the butterfly valve using various attachment sets. IDR..GAW In the case of butterfly valves with stop bar DKR..A, an attachment set. GA with shock suppressor must be used. As of a medium temperature of > 250 C, the actuator is to be protected by a heat deflector.

4, IC 30, Edition 02.16 Examples of application odulating control via three-point step signal VAG odulating control with continuous input signal VAG Threepoint step + DKR..F DKR..H For processes that require high temperature accuracy and low circulation in the furnace. Actuator IC is controlled by a three-point step controller and moves the butterfly valve to the ignition position. The burner starts. The butterfly valve opens or closes between the low-fire/high-fire rate positions depending on the capacity demand of the burner. When the three-point step signal is disconnected, the butterfly valve stops at its current position. 4 20 ma..e + DKR..F For processes that require high temperature accuracy and low circulation in the furnace. Actuator IC..E is controlled by a (0) 4 20 ma or 0 10 V signal. The continuous signal corresponds to the adjustment angle to be approached and offers the option of monitoring the current position of the actuator. DKR..H Threepoint step PZL XXX IC 30 + VFC For processes that require high control accuracy. The low-fire and high-fire rates are adjusted using the control element upstream of the burner. Actuator IC 30 is controlled by a three-point step controller and ensures the desired gas/air mixture is produced. Staged control VAG + via VAS two-point 1 step signal Twopoint step..e + DKR..F DKR..H For processes that require a homogeneous temperature distribution in the furnace. Actuator IC..E is controlled by a two-point step controller and operates in On/Off or High/ Low intermittent mode. The actuator closes when the voltage supply is disconnected.

, IC 30, Edition 02.16 5 S10 S4 S3 S1 S2 S11 1 2 3 4 5 6 7 8 1 1 1 2 1 3 1 5 1 6 R.. 1 7 1 8 1 9 20 max. 0,5 W, modulating control with burner control unit BCU The BCU moves the butterfly valve to prepurge and ignition positions. After pre-purge and burner start, the controller enable signal is issued to an external three-point step controller which positions the butterfly valve in accordance with the capacity demand. Once the pre-purge or ignition positions has been reached, a feedback signal is sent to the BCU. N (L2) L1 (L1) 90 0 0 90 DPS BCU....E, continuous control with burner control unit BCU The BCU controls pre-purge and moves the butterfly valve to pre-purge and ignition positions. Once the BCU has started the burner, the modulation enable signal is issued via terminal 5 (OK). Actuator..E reacts to the (0) 4 20 ma or 0 10 V setpoint specification signals. N (L2) L1 (L1) 90 0 0 90 BCU..

6, IC 30, Edition 02.16, three-point step control with burner control unit BCU The BCU moves the butterfly valve to prepurge and ignition positions. After pre-purge and burner start, the controller enable signal is issued to an external three-point step controller which positions the butterfly valve in accordance with the capacity demand. Once the pre-purge or ignition position has been reached, a feedback signal is sent to the BCU. N (L2) L1 (L1) 90 0 0 90 DPS BCU....E, continuous control with burner control unit BCU The BCU controls pre-purge and moves the butterfly valve to pre-purge and ignition positions. Once the BCU has started the burner, the modulation enable signal is issued via terminal 5 (OK). Actuator..E reacts to the (0) 4 20 ma or 0 10 V setpoint specification signals. 11 12 13 1 6 N (L2) L1 (L1) 90 0 0 90 BCU..

, IC 30, Edition 02.16 7 Type code Code -07-15 -30-60 W Q 2 3 E T R10 Description Actuator Running time in s/90 : 7.5 15 30 60 ains voltage: 230 V AC, 50/60 Hz 120 V AC, 50/60 Hz Torque: 2.5 Nm 3 Nm Continuous control Three-point step control Feedback potentiometer IC 30 Code Description IC 30 Actuator Running time in s/90 : -30 30-60 60 K ains voltage 24 V DC, ± 20% 3 Torque 3 Nm T Three-point step control R10 Feedback potentiometer Code -03-07 -15-30 -60 W Q H 3 7 15 20 30 E T R10 Description Actuator Running time in s/90 : 3.7 7.5 15 30 60 ains voltage: 230 V AC, 50/60 Hz 120 V AC, 50/60 Hz 24 V AC, 50/60 Hz Torque: 3 Nm 7.5 Nm 15 Nm 20 Nm 30 Nm Continuous control Three-point step control Feedback potentiometer Technical data, Angle of rotation: 0 90, adjustable. Holding torque = torque. Duty cycle: 100%. Contact rating of the cam switches: Voltage in. current (resistive load) ax. current (resistive load) 24 230 V, 50/60 Hz 1 ma 2 A 24 V DC 1 ma 100 ma Line entrance for electrical connection: 3 20 plastic cable glands. Screw terminals using the elevator principles for cables up to 4 mm 2 (single core cables) and for cables up to 2.5 mm 2 with wire end ferrules. Typical designed lifetime: Switching current Switching cycles cos ϕ = 1 cos ϕ = 0.3 1 ma 1,000,000 22 ma 1) 1,000,000 100 ma 1,000,000 2 A 100,000 1) Typical contactor application (230 V, 50/60 Hz, 22 ma, cos ϕ = 0.3) Three-point step signal to terminals 1 and 2: minimum pulse duration: 100 ms, minimum pause between 2 pulses: 100 ms. Enclosure: IP 65, safety class: I. Ambient temperature: -20 to +60 C, no condensation permitted. Storage temperature: -20 to +40 C.,..E ains voltage: 120 V AC, -15/+10%, 50/60 Hz, 230 V AC, -15/+10%, 50/60 Hz. Type Running time [s/90 ] Torque [Nm] 50 Hz 60 Hz 50 Hz 60 Hz -07 7.5 6.25 2.5 2-15 15 12.5 3 3-30 30 25 3 3-60 60 50 3 3 Power consumption: 4.9 VA at 50 Hz, 5.8 VA at 60 Hz. Resistance of the feedback potentiometer: 1 kω, max. 1 W.

8, IC 30, Edition 02.16..E Power consumption: terminals 1, 2 and 5: 4.9 VA at 50 Hz, 5.8 VA at 60 Hz, terminal 3: 8.4 VA at 50 Hz, 9.5 VA at 60 Hz, in total not exceeding: 8.4 VA at 50 Hz, 9.5 VA at 60 Hz. Position feedback output: 4 20 ma, electrically isolated, max. 500 Ω load impedance. The output is always active when supply voltage is applied to terminals 3 and 4. Input: electrically isolated, 0 (4) 20 ma: load impedance switchable between 50 Ω and 250 Ω, 0 10 V: 100 kω input resistance.,..e ains voltage: 24 V AC, -15/+10%, 50/60 Hz, 120 V AC, -15/+10%, 50/60 Hz, 230 V AC, -15/+10%, 50/60 Hz. Type Running time [s/90 ] Torque [Nm] 50 Hz 60 Hz 50 Hz/60 Hz -03 3.7 3.1 3-07 7.5 6.25 7-15 15 12.5 15-30 30 25 20-60 60 50 30 Power consumption: 16 VA at 60 Hz, 13 VA at 50 Hz. Resistance of the feedback potentiometer: 1 kω, max. 1 W, max. wiper current : 0.1 ma...e Power consumption: terminals 1, 2 and 5: 16 VA at 60 Hz, 13 VA at 50 Hz, terminal 3: 19 VA at 60 Hz, 16 VA at 50 Hz, in total not exceeding: 19 VA at 60 Hz, 16 VA at 50 Hz. Feedback output: galvanically isolated, max. 500 Ω load impedance. The output is always active when mains voltage is applied to terminal 3. Input: electrically isolated, 4 (0) 20 ma: load impedance switchable between 50 Ω and 250 Ω, 0 10 V: 100 kω input resistance. IC 30 Angle of rotation: 0 90, adjustable. Holding torque = torque. ains voltage: 24 V DC, ±20%. Line entrance for electrical connection: 3 x 16 plastic cable glands (enclosed). Screw terminals using the elevator principles for cables up to 2.5 mm 2 with wire end ferrules. The running time changes depending on the load. It refers to the torque, see type label. Contact rating of the cam switches: Voltage in. current (resistive load) ax. current (resistive load) 24 230 V, 50/60 Hz 1 ma 2 A 24 V DC 1 ma 100 ma Enclosure: IP 65. Duty cycle: 100%. Power consumption: 4 W, when switching on: briefly 8 W. Ambient temperature: -15 to +60 C, no condensation permitted. Storage temperature: -15 to +40 C. Resistance of the feedback potentiometer: 1 kω, < 50 V, recommended wiper current: 0.2 μa. aintenance Actuators IC suffer little wear and require little servicing. We recommend a function check once a year. Ordering Information: Part No. KR1955130QTR