DA E: Series of Narrowband or Wideband Distribution Amplifiers

Similar documents
DA MHz Series of Narrowband or Wideband Distribution Amplifiers

DA : Series of Narrowband or Wideband Distribution Amplifiers

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

MULTIBAND 1/3 RACK-MOUNTED

1/3 RACK-MOUNTED BLOCK CONVERTERS

Multiple Band Outdoor Block Up- and Downconverters

SYNTHESIZED COMMUNICATION CONVERTERS

Signal Stability Analyser

High Performance Outdoor Test Translators

Indoor Dual Converter

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Typical applications:

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Synthesized Clock Generator

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Inmarsat Downconverter Narrowband Downconverter

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

Synthesized Block Up- and Downconverter Indoor / Outdoor

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Modular Block Converter Systems

The Art of Engineering

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

X-Band Redundant LNB Systems

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

Orbital Ka-ISO. Ext Ref Ka LNB with integrated isolator. Orbital Research Ltd Marine Drive, White Rock, BC. Canada V4B 1A9

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Satellite Up- and Downconverter Indoor / Outdoor

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

THE ART OF ENGINEERING

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

R-1580A Microwave Downconverter. Product Brochure

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

Ku-Band Redundant LNB Systems

SATCOM FIBER OPTIC PRODUCTS

C-Band Redundant LNB Systems

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

ThinkRF D GHz RF Downconverter

High-Value 100 Series (Outdoor)

RF Semiconductor Test AXRF RF Port Upgrade Kits

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

DVO700 P FIBRE OPTIC TRANSMITTER

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Wideband LNB: 2.4 GHz

Synthesized Block Up- and Downconverter

Datasheet SHF A

SIR MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz. WIDE FREQUENCY RANGE: GHz

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

R3267/3273 Spectrum Analyzers

THE ART OF ENGINEERING

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

Instruction Manual Model # Block Upconverter

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

L-Band Block Up- and Downconverter Indoor / Outdoor

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

HDO701 FIBRE OPTIC TRANSMITTER

Instruction Manual Model BlockUpconverter

SCR Series Synthesized Converters L, C, X, Ku, and DBS Bands

EX04-000D. DVB-T/2xT/T2 MODULATOR DVB MODULATOR

clipping; yellow LED lights when limiting action occurs. Input Section Features

Advanced Test Equipment Rentals ATEC (2832)

ACION 8000 Series. A8KFR1 1RU Forward Receiver

QRF5000 MDU ENCODER. Data Sheet


USB-TG124A Tracking Generator User Manual

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

OPTICAL DISTRIBUTION STATION -

PL7330T / PL7330R16 RF Link High Power Input, 16dB Optical Budget 45Km nm or 70Km nm

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Technical Data. HF Tuner WJ-9119 WATKINS-JOHNSON. Features

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

GFT Channel Digital Delay Generator

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

Product Catalogue January 2018

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

SMS3000X Series Spectrum Analyzer

PiMPro Portable Analyzer PiMPro Classic 1821

Test Systems. Typical JFW Systems. Matrix switches Programmable assemblies Switch assemblies Manual attenuator assemblies Power divider assemblies

RS Pro SPECTRUM ANALYZER SSA3000X SERIES

Redundant LNB Systems

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

Specifications MAV Series Matrix Switchers

National Park Service Photo UTAH-1OO/3. MADI Terminal.

Redundant LNB Systems

PiMPro Rack Mount Analyzer

CAM Series Channelized Agile Audio/Video Modulators

Satellite Up- and Downconverter

Power Amplifier 1.5 MHz to 18 GHz, Split Bands. Now with smart digital monitoring and control options 19 Rack Mount Family Data Sheet

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Video Digital Optical Converter

PicoScope 6407 Digitizer

Transcription:

DA1-150-10-E: Series of Narrowband or Wideband Distribution Amplifiers Key Features Dual A and B inputs. Automatic or manual switchover, configured by the Ethernet port. 1-150 MHz wideband operation. Other band frequencies from 100 khz to 200 MHz are available AGC Level Controlled. Output level remains stable to 0.1 db even if input varies AGC can be disabled if required. Amplifier then has fixed gain. Different gains can be made upon request 5-40 sine outputs. Each output can be independently set to 0 dbm to > +10 dbm (options up to +20 dbm) Alarm monitoring. Input, all outputs and power supplies have alarm monitoring. Indication by front panel LEDS or Ethernet. Plus there is an overall alarm on the rear panel (DC voltage level). Ultra low phase noise. Typically -135 dbc @ 1 Hz offset. Floor Noise to -172 dbc/hz is available. Excellent Allan Deviation. Typically <4 x 10-14 at 1 sec, 2 x 10-17 at longer time intervals. 90 db channel isolation and 130 db reverse isolation. Protects reference input and prevents cross-talk. BNC Connectors standard. SMA or TNC or N type connectors optionally available. Ethernet interface for alarm monitoring and unit configuration. Dual AC Power Supplies as standard with automatic switchover in the event one supply fails. Optional Redundancy (two units with automatic switchover) Many other options and customized options. Bespoke design service available. General Description The DA1-150-10-E series are a series of ultra-low noise distribution amplifiers. They cover 1-150 MHz (optional to over 200 MHz) either in a wideband unit (e.g. 1-150 MHz), or narrowband versions (e.g. 5 MHz, 10 MHz). They can be used to synchronize from five to forty instruments to a frequency reference input. The reference input will typically be an OXCO, Rubidium, Cesium or Hydrogen Maser Frequency Standard. The DA1-150-10-E has features not found in any competitive unit. This makes the DA1-150-10-E the industry s leading distribution amplifier. The DA1-150-10-E has outstanding low phase noise. Therefore, the DA1-150-10-E will not add any appreciable noise to the reference input. Phase noise is typically <-140 dbc @ 1 Hz. This low phase noise enables units to be cascaded for over 1000 outputs. Amplifier with Gain and Automatic Gain Control (AGC) Unlike most competitive units, the DA1-150-10-E accepts input levels from +7 dbm to +19 dbm. The output will not vary with input variations. Also options exist to change this input level range to values from -20 dbm to +30 dbm. Sinewave

outputs are adjustable from 0 dbm to > +10 dbm (up to +20 dbm is available as an option). This AGC function is very useful when long cable runs are being used or equipment has different input level requirements. The AGC can be disabled if required, making the unit a fixed gain amplifier. Note that the AGC range may be different when other options are installed. Contact the manufacturer for further details on different configurations. Outputs There are five to forty sinewave outputs depending upon what option is ordered. Each output is completely isolated from the input and each other. Therefore, the reference oscillator connected to the DA1-150-10-E s input is protected against load variations, short circuits etc. that may be applied to the outputs. Channel to channel isolation is > 90 db @ 10 MHz. Output to input isolation (reverse isolation) is > 130 db @ 10 MHz Each output port can be independently set to any level from 0 to > +10 dbm on the standard unit and outputs to +20 dbm are optional available. The ability to set every output to a different level is very useful when dealing with equipment that has different input level ranges. This is a unique feature of the DA1-150-10-E not found on any other unit. Phase Noise The DA1-150-10-E has very low phase noise and Allan deviation. This enables units to be connected in series without adding any appreciable noise to the reference input. Up to 1000 outputs can be derived from one input using multiple amplifiers, without the need of cascading more than three amplifiers at a time. This keeps the phase noise to a minimum. Two typical plots of phase noise at 10 MHz are shown below. The first plot is for an amplifier with 3 db gain and AGC. The second plot for a unit with 0 db fixed gain (no AGC). Note that phase noise may vary when other options are installed. Contact the manufacturer on expected phase noise for different configurations..

Allan Deviation Plot The plot below shows the Allan deviation plot of the DA1-150-10-E. Allan Deviation is typically < 2 x10-14 for tau = 1 second with the noise floor less than 2 x10-17. Phase Stable with matched outputs The wide frequency bandwidth allows the outputs to have stable phase. The phase stability is typically 5 ps/ C. Also the delay match between outputs is better than 2.5 ns overall and typically less than 500 ps between groups of five outputs.

Alarms There are alarms for the input, every output and power supplies. Should the RF level drop on the input or any output, an alarm will be raised. Front panel LED s show the status of the alarms including individual outputs. The status of any alarm can also be queried via the Ethernet interface. Additionally an overall alarm signal is available on the rear panel as a DC level output. Ethernet Interface The Ethernet interface allows the unit to be configured as well as monitoring all alarms. An embedded web page allows the status of the amplifier to be monitored. Also, firmware updates are made using the Ethernet interface. Telnet protocols are also optional available. Dual A and B Inputs The DA1-150-10-E has two reference frequency inputs, A and B. They can be configured, via the Ethernet port, so either A or B is the master with the other as the slave. In the event that the master input falls below a factory set limit, the slave will be automatically switched in with minimum glitch in the outputs. Alternatively the inputs can be set to manual mode where their operation is set by the Ethernet interface. Front panel LEDS show the status of the inputs. Dual AC Power Supplies Two independent AC power supplies with separate AC connectors are incorporated. If one AC input or power supply fails, the second power supply will continue to operate the unit with no glitch in output. Front panel LEDS show the status of each power supply. The Ethernet port can also be used to query the power supplies status. Applications The DA1-150-10-E Distribution Amplifier is ideal for use in calibration or standard laboratories, space research, satellite systems, communication systems or anywhere where ultimate performance is needed. Miscellaneous Information The DA1-150-10-E is a highly reliable unit. The DA1-150-10-E is housed in a fully screened 19 rack mount case and operates from a 100 to 240 VAC supply (usable 90 to 260 VAC). The DA1-150-10-E is CE marked for sale within the EEC. It is guaranteed for three years. Options and Other Amplifiers available from Precision Test Systems Fully DC isolated outputs. Useful in preventing ground loops on long cable runs. Squarewave outputs. Either at the same frequency as the input, or at different frequencies. Multiplied or divided outputs. E.g. 10 MHz, input with 5 MHz output. 10 MHz input with 100 MHz output. Any type of multiplication / division can be incorporated. High and Low pass filters. This reduces broadband noise and reduces the harmonic output. Guaranteed phase noise specifications. Measured phase noise specifications supplied with unit. Higher output levels, up to +20 dbm. Different amplifier gains allowing different input levels from -20 dbm to +30 dbm to be accommodated. Note: that phase noise specifications will vary when different amplifier gains are fitted. Consult manufacturer for further details. Additional outputs. Up to 15 outputs in a 1U case, or 40 outputs in a 2U case. External DC Power Input. The DA1-150-10-E can also have an external 12VDC input. This can be used to provide backup power. If AC power is lost, the DA1-150-10-E will immediately switch to the DC supply. Redundancy. Two units operate together. If one unit fails, the outputs are automatically switched to the secondary unit. Internal backup oscillator. This oscillator is automatically enabled should the input signals fail.

DA1-150-10-E Rear view Precision Test Systems also manufacturers the PTS50, DA1010 and DA1-100 series of distribution amplifiers. These models are lower cost alternatives to the DA1-150-10-E but still give very good performance. DA1-150-10-E SPECIFICATIONS FOR STANDARD UNIT * Specification Parameter Specification Comments Dual Reference Inputs (A and B) Frequency 1-150 MHz See model list below for actual frequencies Bandwidth (2-100 MHz) ± 3 db ± 5 db from 1 150 MHz Impedance / Input VSWR 50 Ω / < 1.5:1 @ 10 MHz Typically < 1.35:1 @ 10 MHz Input Level +7 dbm to + 19 dbm AGC Controlled. +25 dbm damage level Reference Input Switching Either Input A or Input B is used Automatic or manual switchover Switching time from A to B or B to A < 10 ms Typical Sinewave Outputs Output Waveform Sinewave 50 Ω BNC Connector on rear panel Output Frequency Output VSWR Exactly the same as the input < 1.2: 1 @ 10 MHz Output level (individually adjustable) Adjustable 0 dbm to > +10 dbm Outputs to +20 dbm optionally available Output Level Stability < 0.05 db / C Typically < 0.02 db / C Harmonic Distortion (wideband version) Harmonic Distortion (narrowband version) -20 dbc Typically -25dBc. Assumes input source s harmonics are -25 dbc or lower. -45 dbc Typically -50dBc. Assumes input source s harmonics are -30 dbc or lower. Spurious Outputs (> 500 khz) -125 dbc Typical Channel to Channel Isolation > 90 db @ 10 MHz Input to Output Isolation Delay match between outputs (wideband version only) Temperature Stability of delay (wideband version only) > 130 db @ 10 MHz < 2.5 ns (<500 ps / 5) < 500 ps within group of 5 outputs 10 ps/ C Typically 5 ps/ C Slave Output Slave Output Output derived from selected input Level = input level - 7 db. Allan Deviation (typical @ 10 MHz) Allan Deviation < 7 x 10-14 (1 sec) < 5 x 10-13 at 0.1 sec. Floor < 3 x 10-17 Phase Noise (@ offset frequency) with +7 dbm in and 10 to +13 dbm out Phase Noise (@ offset frequency) with +13 dbm input and +13 dbm output @ 1-130 @ 1-140 @10-148 @10-157 Phase Noise (@ 10 MHz) @100-157 @100-166 @1k -163 @1k -170 @10k -165 @10k -171 General Power (AC) Dual 100-240 VAC (usable 90-260) @100k -165 @100k -171 This is for a unit with ten outputs and a gain of 6 db. These are typical results This is for a unit with five outputs and a gain of 0 db. These are typical results

Specification Parameter Specification Comments Power Input Frequency 47 Hz to 63 Hz Power Consumption 50 Watts maximum For a standard unit. Size and weight (5 to 15 outputs) 483 x 300 x 44 mm and 3.2 kg Width x Depth x Height Size and weight (16 to 40 outputs) 483 x 300 x 88 mm and 3.8 kg Width x Depth x Height Operating Temperature -10 to +50 C Humidity < 90% non-condensing Storage Temperature -20 to +80 C Humidity < 90% non-condensing Alarm Output Alarm Outputs via DB-15 connector and Ethernet port. Overall alarm DC output on DB-15 connector. High = No Alarm. MTBF (estimate) 500,000 hours Based on real data of similar products Ethernet Interface Connector RJ45 On rear panel Speed 10/100 Mbps Ethernet Control / Protocols Embedded web page Telnet with option 27 Options (not all options can be fitted at the same time, consult manufacturer) Option 01 Dual changeover alarm relay Activated in the event of an alarm Option 02A / B Ground Isolated Input / Outputs Option 03 Redundancy Requires two units Option 04 / 05 / 05B TNC / SMA/ N type connectors Replaces standard BNC connectors Option 06 Guaranteed Phase Noise Plots supplied with unit Option 07 Option 08 with an additional letter Option 08A Option 09 Option 09A to Option 09G UKAS traceable certificate Increased Output levels. +13 dbm o/p for +7 to +19 dbm i/p Additional five sinewave outputs Additional sinewave outputs (>5) Various options to +20 dbm available 15 o/p s in all in 1 U case. Consult PTS for further details Option 10 Squarewave outputs TTL/CMOS or ECL output levels Option 11 Divided frequency output E.g. 2.048 MHz, 1MHz, 10 MHz, 1 pps Option 12 Multiplied output E.g. X2, X5, X10, X100. Option 13 with an additional letter Special narrow band version State centre frequency and bandwidth Option 14 External DC input Nominal 12V external DC. Option 16-XXX Internal backup oscillator XXX = frequency in MHz. Option 17-XXX Different Gain Levels Customer to advise gain requirement Option 18 Delete five outputs Negative option. Reduces price. Option 22 Additional internal amplifier Increases sensitivity to -20 dbm Option 26 / 26B Option 27 Fiber optic input and outputs Telnet protocols on Ethernet port * Specifications only valid for the DA1-150-10-E. Some specifications may vary with installed options. Consult Precision Test Systems for further details.

DA1-150-10-E series. Model numbering: DA1-150-10-E: Wideband 1 150 MHz DA1-150-10-E-10MHz: Narrowband 10 MHz DA1-150-10-E-100kHz: Narrowband 100 khz DA1-150-10-E-13MHz: Narrowband 13 MHz DA1-150-10-E-1MHz: Narrowband 1MHz DA1-150-10-E-15MHz: Narrowband 15 MHz DA1-150-10-E-2048 khz: Narrowband 2048 khz DA1-150-10-E-150MHz: Narrowband 150 MHz DA1-150-10-E-5MHz: Narrowband 5 MHz DA1-150-10-E-160MHz: Narrowband 160 MHz Precision Test Systems Head Office - UK South Africa USA Precision Test Systems cc Randburg Gauteng South Africa Fax: 08651 58198 Email: sasales@ptsyst.com Web: www.ptsyst.com Precision Test Systems LTD The Studio, Whitehouse Farm New Hall Lane, Mundon Maldon, Essex, CM9 6PJ, UK Tel: +44 (0) 870 368 9608 Fax: +44 (0) 1245 330030 Email: sales@ptsyst.com Web: www.ptsyst.com Precision Test Systems 304 S. Jones Blvd, Suite # 807 Las Vegas Nevada, 89107 USA Tel: 1 888 876 4804 Fax: 1 832 201 6564 Email : usasales@ptsyst.com Web : www.ptsyst.com Further information available from www.ptsyst.com. Specifications and features subject to change without notice (131016)