Quality & Metering Q.1. Multi-functional electric energy meters

Similar documents
Quality & Metering. Multi-functional electric energy meters

POWER FACTOR REGULATOR

PRINCIPLES AND APPLICATIONS

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

MULTIPURPOSE THREE PHASE METER CIRWATT-C

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

MULTI-PURPOSE THREE PHASE METER

PowerLogic power-monitoring units

Generator protection relay

ODW-621. RS-232 Point-to-point applications

02/11/2015

multi-function meters

Fibre Optic Modem ODW-622

LONWORKS Fibre Optic Converter

V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Rack mounted telephone- and leased line modem for industrial applications

Flexible Counter Series in DIN size 24 x 48 mm

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

Fibre Optic Modem ODW-611

SAPLING WIRED SYSTEM

High performance circuit breakers

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

LAUREL ELECTRONICS, INC.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

MASTER DIALOG ERM 8-20kVA three/single phase ERT kVA three/three phase

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Pulse Concentrator User Manual EPC-12

EPC-12 User Manual.

FN Series Scalable N+1 UPS 3kVA to 40kVA Tower

I/A Series Hardware Fiber Optic LAN Converter

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

WVR500 Waveform/Vector Monitor

Operating instructions Electronic preset counter Type series 717

Flexible Counter Series in DIN size 24 x 48 mm

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Fibre optic router for TP/FT-10 LRW-112PP

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

R&S ZVA110 Vector Network Analyzer Specifications

LONWORKS Fibre Optic Router

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Process Transmitter RMA 422

15 Series - Dimmer

Gamma instabus. Technical product information

Preset counters, electronic

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

MS2540 Current Loop Receiver with RS485 Communication

3500/42E Vibration Monitor

DMP 331i / DMP 333i LMP 331 i

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION SECTION 16901

SIMATRIX NEO V2 Modular Video Matrix

We ve got the best technology to fit your power monitoring needs. Scenario works on all!

Part 2. LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories

DCP100 Digital Control Programmer Specifications

Noise Detector ND-1 Operating Manual

Indoor Linear 80W Driver SI-C215280N2KR

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

The Art of Engineering

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

LED Driver Linear / area fixed output

Model KBF 115 Constant climate chambers with large temperature / humidity range

SH2RE16A4. Output relay module. Benefits. Description

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

HOBO H Energy Logger

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

EVF 300 series. Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit.

LD OEM/LD PDS/LD PeCo

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Certificate of Calibration

Model KT 115 Cooling incubators with thermoelectric cooling

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Dissolved Oxygen Transmitter

Multifunction Digital Timer

DIGITAL INSTRUMENTS S.R.L. SPM-ETH (Synchro Phasor Meter over ETH)

Time-Lag Relays. User s Handbook (General Model)

INSTALLATION & USER GUIDE

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Process transmitter RMA422

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

LED Driver Linear / area dimming

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

POWER MONITORS ENERIUM RANGE. Minimize your energy consumption and optimize your installation

Modular pulse operated latching relay 16 A

MIKRO POWER FACTOR CORRECTION COMPONENTS

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

LED Driver Compact fixed output

Label Applicator HERMA 400

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male

LED MODULES READYLINE DL

LED Driver Compact dimming

Transcription:

uality & Metering.1

.1 Multi-functional electric energy meters Introduction 3.1 - Product selection table 5 CIRWATT A Single-phase active energy meter, Class 1 1-7 CIRWATT B II Single-phase active energy meter, Class B and reactive, Class 2 1-9 CIRWATT B III Three-phase energy meter 1-11 CIRWATT C Digital multi-function three-phase meter 1-15 CIRWATT D High-performance, multi-function static meter 1-18 PLC-800 Concentrator for PLC systems 1-21 Relation between products and accessories 1-23 1-2

.1 CIRWATT is a family of combined multi-functional meters that can meet any requirement of an energy metering system, including important aspects, such as quality, accuracy, safety and reliability. The new metering technologies have allowed CIRCUTOR to develop new state-of-the-art equipment, including additional functions for the control and management of metering systems, for example, astronomical clocks, control of the maximum demand, control of programmable power, multi-supply meter (water and gas), meters with photovoltaic applications (two-directional), communications with PLC systems, etc..1 The CIRWATT family offers a full range of electrical energy meters that are adapted to the type of application. It has the following sub-families: Definition In general, electrical consumption meters are devices that meter the consumption of electrical energy in a circuit or electricity service. The market offers electromechanical and electronic meters. Electromechanical meters use parasitic current and voltage in a disc, influenced by the magnetic fields produced by the turning movement of the needles on a face. Electronic meters use a digital metering mechanism. 1-3

.1 Advantage of CIRWATT meters: Remote management through different channels, for example, through the RS-232 port, RS-485, PLC, etc. Readings can be taken with local (Optical Reader), centralised or remote systems. There are no mobile parts, so there is no wear. There is an internal memory (load curve + billing + events). Programmable outputs: yenergy impulses ytaximeter pulse yactive rate ymaximum demand alarm yconfigurable alarms (V, A, W, etc.). Lower error diversion throughout the meter's working life. Remote loading of the meter's firmware. Updates. Cost optimisation. Greater reading accuracy. Optimisation of the space inside meter cabinets (meter + analyzer + clock + taximeter) in a single device. Metering of electrical parameters (Voltage, Current, Power Factor, Reactive Energy in 4 quadrants, ). Detection of fraud or manipulation. Remote interruption and reinstatement. Centralisation of the impulses of other meters (water, gas,...). Variable regulation of the weight of the impulse. Integration in home energy management systems. Configurable contracts, rates and seasons. Storage in the event log memory: yvoltage interruptions yincorrect phase connection ymanipulation Simple display on the screen: ysimple and interesting interface with the parameters metered by the meter. ythe user can check the partial consumption. The user can check and control his own consumption. ytext messages can be sent to the users with notifications or alarms through the alarm outputs integrated in the meter and external GSM/GPRS modem. ybilling simulation with the software, using the meter's internal memory. This section includes the billing meters, but it does not show the sub-metering meters. Submetering meters are shown in section M3. Applications Applicable to billing CIRWATT meters are energy meters designed to meter the transfer of energy between frontier points. They are used by utilities companies and other customers. The use of all types of communications means that the information can be recorded by the meters locally or remotely. Ports CIRWATT's meters can be used as submetering units in wharfs. One of the typical applications of the said units uses PLC communications, since remote communications can be used to centralise the readings in the port's control centre. The consumption of water can be metered with the impulses emitted by the water meter, connected to the digital inputs of the energy meter, depending on the type of meter. Therefore, automatic water and energy readings will be taken through the PLC communications. Photovoltaic installations There are two possible CIRWATT. The first application involves the placement of the single-phase meter connected to the inverter's output of the solar panel and a totalizer, usually threephase, located at the frontier point. The second application involves the installation of a three-phase meter in the connection point of the electricity company. One of the key positions for both applications is the communications with meters. In the first one, the optical system uses PLC communications and in the second one, when there are different installations with various totalizers, the communications can be Ethernet, RS- 485 or Modem, thus gathering the data in centralised form. Submetering installations Another application used is submetering, not for official billing purposes, but for the metering of energy in the different plots, bungalows, rented apartments, etc. In these cases, metering can be single or three-phase, with CIRWATT meters and PLC communications, centralising all readings in a single PLC-800 concentrator. This is the way to achieve a more efficient installation in energy terms. Single-phase meters with circuit breakers can be used for the remote management of the consumption, so that the relay is opened and closed to record / cancel the supply and limit the current, programming the internal relay and controlling the demand. 1-4

.1 Product selection table Equipment Active / Reactive Energy Class Direct / Indirect metering Voltage Current COM1 Communications COM2 Communications Load curve 1 Load curve 2 Events Closing Inputs / Outputs *** Page CIRWATT A 1 / - Single Direct 230 V 127 V 10(120) A 10(60) A PLC - 1 month (60 min) ** - - 1 7 CIRWATT B II B / 2 Single Direct 230 V 10(60) A PLC - 3 months (60 min) - 512 1 9 CIRWATT B III Three- Phase Direct / Indirec 5(10) A 10(100) A PLC 3 months (60 min) - 512 1 11 CIRWATT C 1 / 2 Three- Phase Direct / Indirect 3x57/100 V 3x230/400 V 5(10) A 10(100) A PLC RS-232 RS-232 RS-485 - RS-485 Ethernet RS-485 213 days (60 min) 53 days (15 min) 512 64 15 CIRWATT D 0,23 / 0,5 0,55 / 1 Three- Phase Indirect 3x57/100 V 3x63.5/110 V* 1(2) A 5(10) A RS-232 RS-485 Ethernet 213 days (60 min) 53 days (15 min) 512 64 18 PLC-800 - - 3x230/400 V 3x127/220 V - PLC Ethernet GSMGPRS - - 21 (*) For other voltages, please ask (**) Only models with PLC (***) See specific catalogue SELECTION TABLE - Single-phase Energy Meters CIRWATT - - x - TYPE METER TB TA 2 wires, asymmetrical connection 2 Class 1 Active 10 Class B Active / Class 2.0 Reactive 12 1 x 127 V c.a. B 1 x 230 V c.a. E 5 (60) S2 10 (120) S3 10 (60) S4 50 Hz A 60 Hz B Connection mode Accuracy Measured voltage Current Measurement Frequency Without communication 0 RS-485 2 R1 / R2 (PLC) PLC A 4 Communications R1 / R2 (PLC) PLC B 5 Without card 0 2 rrelays 5A 250V (tarif indicator) 3 impulse meter input A type B B type A A Import only (2 uadrants) 0 Bidirectional (4 uadrants) 1 Unidirectional (4 uadrants) 2 Expansion Registration mode Cut off relay (phase) 2 More features 1-5

.1 SELECTION TABLE - Three-phase Energy Meters CIRWATT - - x - TYPE METER TB III TC TD 4 wires 4 0.2S active class / 0.5 Reactive class 02 0.5S active class/ 1.0 Reactive class 05 C Active class / 1.0 Reactive class 05 B Active class / 2.0 Reactive class 10 3 x 57 / 100 V a.c. (4w) L 3 x 63.5 / 110 V a.c. (4w) M 3 x 127 / 220 V a.c. N 3 x 220 / 380 V a.c. O 3 x 230 / 400 V a.c. (4w) 3 x 127 / 220 V a.c...3x230/400 Va.c. U 5 (10) A Transformer T5 10 (100) A Direct D1 50 Hz A 60 Hz B Automatic (50 / 60 Hz) C Connection mode Accuracy Measured voltage Current measure Frequency Without communications 0 R1 / R2 (PLC) RS232 / - R1 / R2 (PLC) RS485 / - R1 / R2 (PLC) Ethernet / - R1 / R2 (PLC) R1 / R2 (PLC) R1 / R2 (PLC) R1 / R2 (PLC) R1 / R2 (PLC) R1 / R2 (PLC) R1 / R2 (PLC) R1 / R2 (PLC) RS232 / - (PLC A) RS232 / - (PLC B) RS232 / RS232 RS485 / RS485 RS232 / RS485 RS232 / Ether. RS232/ USB RS485 / Ether. RS232 / RS232 RS232 / RS485 RS232 / Ether. PLC A 4 PLC B 5 RS232 / RS232 RS485 / RS485 RS232 / RS485 RS232 / Ether. Without card 0 Inputs / outputs (optomos) 4 inputs / outputs (relay) 5 Inputs (water and gas) A Earth leakage measure B 1 2 3 7 8 9 A C D Communications Expansion modules type B meter B type C meter C type D meter D Import only (2 uadrants) 0 Bidirectional (4 uadrants) 1 Unidirectional (4 uadrants) 2 Without more features 0 Cutoff relay 2 Registration mode More features 1-6

.1 CIRWATT A Single-phase active energy meter, Class 1 Description Features CIRWATT A is a single-phase, digital multifunction meter, Class 1, for the metering of active energy. CIRWATT A complies with the existing regulations applicable to electronic meters and it has an autonomous data retention system that avoids them from being lost when there is an interruption in the power supply. Likewise, it can be read through the screen (even when there is no power supply) and through the optical port (protocol IEC-61107). There is also a type with PLC (Power Line Carrier) communications and an internal circuit breaker for the management of the demand, with an innovating reclosure system. Application It has been specially designed for installations where electromechanical meters do not satisfy the current needs, particularly those that require a single-phase meter with a billing system. There are three main types of A-meters: multi-rate meter; for photovoltaic applications and meter with PLC communications. Power supply Nominal voltage Consumption Frequency Self-powered 127 V or 230 V (depending on the type) < 2 W / 10 V A 50 / 60 Hz, no differentiation Operating temperature - 20 ºC... + 60 ºC Voltage metering Connection Reference voltages Frequency Current metering Currents (i n ) Symmetrical or asymmetrical 127 V or 230 V (depending on the type) Automatic (50 / 60 Hz, with no differentiation) 5 A Direct (Maximum 60 A) 10 A Direct (Maximum 120 A) Maximum current 12 I n Accuracy Active Energy Class 1.0 (IEC 62053-21) Calculation and processing Microprocessor Based on DSP Converter 16 bits Memory Data RAM type, stored by Lithium battery Setup and events Non-volatile memory of the FLASH type Battery Lithium Working Life > 10 years Clock Grid frequency quartz oscillator Drift < 0.5 s/day at 25 ºC Digital outputs Potential-free Optocoupler (24 V) Relay outputs 230 V - 10 A Mechanical relay LED Outputs Maximum rate Safety 1000 impulses / kw h Category III (110 V) in accordance with EN-61010 Build features Enclosure In compliance with DIN 43859 Dimensions In compliance with DIN 43857 Degree of protection IP 51 Optical reader IEC-61107 for local access 1-7

.1 CIRWATT A Single-phase active energy meter, Class 1 Dimensions Standards EN 62053-21 Standards for static, active energy meters for alternating current, Class 1 EN 55022 EN 61000-4-6 EN 61000-4-8 Driven emissions: Class B / Radiated emissions: Class B Immunity to RF fields coupled to cables (common mode): 10 V Immunity to magnetic fields and grid frequency: 30 A/m References Metering voltage 230 Vac Current metering range (A) Hourly discrimination uadrants Relay outputs Impulse outputs Impulse inputs 10 (120) DH1 2 1 CIRWATT A - 210-ED3-01A-00 10 (120) DH0 2 2 CIRWATT A - 210-ED3-01A-00 5 (60) DH1 2 1 CIRWATT A - 210-ED4-01A-00 5 (60) DH0 2 1 CIRWATT A - 210-ED4-01A-00 10 (120) DH1 4 1 CIRWATT A - 210-ED3-01A-10 10 (120) DH1 2 1 PLC A CIRWATT A - 210-ED3-41A-00 10 (120) DH1 2 2 PLC A CIRWATT A - 210-ED3-44A-00 5 (60) DH1 2 1 PLC A CIRWATT A - 210-ED3-41A-02 10 (120) DH1 4 1 PLC A CIRWATT A - 210-ED3-41A-00 Communication Internal Circuit breaker Connections With one or two outputs of the mechanical relay With a digital energy impulse output 21 22 23 24 21 22 1 3 4 6 1 3 4 6 L RED N L CARGA N L RED N L CARGA N 1-8

.1 CIRWATT B II Single-phase active energy meter, Class B and reactive, Class 2 Description Features CIRWATT B is a multi-function digital singlephase meter, Class B, for the metering of active energy and Class 2 for the metering of reactive energy. The meter complies with the current European legislation related to energy meters (MID) EN 50470-1 and EN 50470-3, which approves the installation of these meters in any country of the European Union. It includes PLC (Power Line Carrier) communications through the power grid and an optical port. Both types of communications use the EC-870-5-102 protocol. It also includes an analyzer that can store up to 3 months of hourly records of the 6 types of energy. Likewise, data can be read when there is no voltage. It includes a circuit breaker, which can be used by the user to control the supply demand with a reliable and safe approach. Application The main application of the CIRWATT B meter is the metering of active and reactive energy for billing purposes, whenever a meter with high performance features is required at an optimised cost. PLC communications can be used for the remote download of all data recorded by the meter through a PLC800 concentrator. The circuit breaker integrated in the meter can be used to manage the supply remotely, opening/closing the circuit breaker and programming the hired power above a value that will activate the circuit breaker, opening it and reclosing it to guarantee the safety for the final user. Power supply Nominal voltage Self-powered 230 V Tolerance ± 20 % Consumption Frequency < 2 W / 10 V A 50 / 60 Hz, no differentiation Operating temperature - 25 ºC... + 70 ºC Voltage metering Connection Asymmetrical Reference voltages 230 V Frequency Automatic (50 / 60 Hz, with no differentiation) Self-consumption of the voltage circuit < 2 W / 10 V A Current metering Currents (i n ) 10 A Direct (Maximum 60 A) Maximum current 60 A Start-up current < 10 ma Self-consumption of the voltage circuit 0.2 V A at 10 A Accuracy Active Energy Class B (50470) Reactive Energy Class 2.0 (IEC 62053-21) Calculation and processing Microprocessor Risc 16 bits Converter 16 bits Memory Data RAM type, stored by Lithium battery Setup and events Non-volatile memory of the FLASH type Battery Lithium Working Life > 15 years Clock Self-compensated quartz crystal oscillator Drift < 0.5 s/day at 25 ºC Billing output Relay Operational Selection of the activation rate Features Max. 250 Vac 5 A with connection to the neutral potential when activated Build features Enclosure In compliance with DIN 43859 Dimensions In compliance with DIN 43857 Degree of protection IP 53 1-9

.1 CIRWATT B II Single-phase active energy meter, Class B and reactive, Class 2 Dimensions 62 129 215 Features Standards Optical port Hardware EN 62056 Speed 9600 baud CIRCUTOR version Protocol REE Protocol, based on IEC 870 PLC Protocol Modulation system Consumption Tampering detector Activation Delay Insulation Alternating voltage CIRCUTOR - Renesas and PRIME DCSK with repeater system 1.2 W - 12 V A Manipulation of the meter or connections Activation is delayed 72 hours to facilitate the installation 4 kv RMS 50 Hz during 1 minute EN 50470-1 and EN 50470-3 Standards for static, active energy meters for alternating current, Class B EN 55022 Driven emissions: Class B Radiated emissions: Class B EN 61000-4-11 Gaps or brief voltage interruptions EN 61000-4-2 Electrostatic discharges EN 61000-4-3 Radio-frequency electromagnetic fields EN 61000-4-4 Electrical transient bursts EN 61000-4-5 Shockwave EN 61000-4-6 Over-impulse 1.2/50 ms - 0 W - strong impedance 6 kv at 60 ºC and 240 ºC with positive and negative polarity Alterations driven and induced by radio-frequency fields EN 61000-4-8 Magnetic fields in the grid frequency with an external origin References Connections Metering voltage 230 Vac Current metering range (A) Hourly discrimination uadrants Relay outputs Impulse outputs Impulse inputs Communication Internal Circuit breaker Code 10 (60) DH1 4 2 PLC A CIRWATT B - 212-ES4-43B-12 B330 10 (60) DH0 4 2 PLC A CIRWATT B - 212-ED4-43B-12 BL30 1 L RED N 23 24 3 4 6 L CARGA N 1-10

.1 CIRWATT B III Three-phase energy meter Description Features The new technological changes in the international electrical sector have given rise to new needs and requirements in terms of more flexible rates, new communication methods and a clear optimisation of prices. All of these changes have led us towards the optimisation of the management of energy in installations and distribution networks. CIRWATT B III can adapt to all of these new challenges. It can use many different types of communication methods and rates that can be adapted to any sector requirement. Finally, but also as important, is the compliance with the most relevant sector regulations: EN, IEC and MID. Application CIRWATT B is ideal for LV and MV power supplies up to 450 kw. Special 4 meter for FV plants, with an endless number of communications options. Power supply Direct Indirect Nominal voltage 3x230 (400)V - 3x127 (230)V 3x230 (400) V - 3x127 (230) V - 3x63,5 (110)V 80 %... 115 % U n <2 W; 10 V A 50 ó 60 Hz Tolerance Consumption Frequency Voltage measurement Connection Asymmetrical Reference voltage 400 V Frequency 50 ó 60 Hz Voltage consumption of the circuit < 2 W; 10 V A Current measurament Class B Class B Class C Nominal reference current l ref 10 A.../5 A,.../1 A Maximum current l max 100 A 10 A / 2 A Start-up current l st < 0,04 x I tr 0,04 x I tr 0,02 x I tr Minimum current l min < 0,5 x I tr 0,2 x I tr 0,2 x I tr Current consumption of the circuit < 0,1 V A 0,25 0,1 Accuracy class Accuracy measured in active energy EN 50470 - Class B EN 50470 - Class B, Class C Accuracy measured in reactive energy UNE-EN 62053-21 - Class 2 UNE-EN 62053-21 - Class 2, Class 1 Memory Data Non-volatile memory Non-volatile memory Setup and events Serial flash Serial flash Battery Lithium Working Life >20 years @ 30ºC Clock Gregorian calendar Source Temperature compensated oscillator Accuracy (EN61038) < 0.5 s/day at 23 ºC Environmental influence Operating temperature range -25 º...+70 ºC Storage temperature range -40... +85 ºC Temperature coefficient < 15 ppm/k Humidity 95 % máx. Insulation Insulating voltage 4 kv a 50 Hz during 1 min Impulse voltage 1.2/50 µs - IEC 62052-11 8 kv Protection degree (IEC 62052-11) II Display LCD Number of data digits up to 8 Size of data digits 8 mm Display data reading when there is no voltage. Yes 1-11

.1 CIRWATT B III Three-phase energy meter Features Optical communications interface Rate programming Serial, two-directional Number of days 12 Hardware IEC 62056-21 s of days 10 Protocol REE, based on IEC 870-5-102 Contracts 3 Tampering detector Number of rates 9 Detection Opening the terminal cover Discrimination 1 hour Micro-switch Holidays/festivities 30 Function Construction features Detects intruders when there is no voltage. Special days 12 Load curve Connection Asymmetrical Number of load curves 2 External dimensions DIN 43857 Integration time Programmable: 1... 253 min Enclosing features DIN 43859 Recording depth 4000 IP Degree (IEC 60529) IP 51 Events PLC Number of events 200 Modulation system DSCK with repeater system Billing closures Hardware CENELEC A or CENELEC B Number of locks 12, per contract Protocol CirPLC and PEP (PLC Encapsulated Protocol) Disabled / Programmable date and hour References Class (Active/ Reactive) uadrants Frequency (Hz) Measuring range V Measuring range A Communication COM1 Communication COM2 Code B / 2 2 50 Hz 3x230/400 V 10 (100)A RS232 RS232 CIRWATT B 410-D1A-70B00 B2A0 B / 2 2 50 Hz 3x230/400 V 10 (100)A RS485 RS485 CIRWATT B 410-D1A-80B00 B2E0 B / 2 2 50 Hz 3x230/400 V 10 (100)A RS232 RS485 CIRWATT B 410-D1A-90B00 B2B0 B / 2 2 50 Hz 3x230/400 V 10 (100)A RS232 ETHERNET CIRWATT B 410-D1A-A0B00 B2C0 B / 2 2 50 Hz 3x230/400 V 10 (100)A RS485 ETHERNET CIRWATT B 410-D1A-D0B00 B2D0 B / 2 2 50 Hz 3x127/220 V 10 (100)A RS232 RS232 CIRWATT B 410-ND1A-70B00 B540 B / 2 2 50 Hz 3x127/220 V 10 (100)A RS485 RS485 CIRWATT B 410-ND1A-80B00 B5E0 B / 2 2 50 Hz 3x127/220 V 10 (100)A RS232 RS485 CIRWATT B 410-ND1A-90B00 B5B0 B / 2 2 50 Hz 3x127/220 V 10 (100)A RS232 ETHERNET CIRWATT B 410-ND1A-A0B00 B5C0 B / 2 2 50 Hz 3x127/220 V 10 (100)A RS485 ETHERNET CIRWATT B 410-ND1A-D0B00 B5D0 B / 2 2 50 Hz 3x230/400 V /5A RS232 RS232 CIRWATT B 410-T5A-70B00 B660 B / 2 2 50 Hz 3x230/400 V /5A RS485 RS485 CIRWATT B 410-T5A-80B00 B6A0 B / 2 2 50 Hz 3x230/400 V /5A RS232 RS485 CIRWATT B 410-T5A-90B00 B670 B / 2 2 50 Hz 3x230/400 V /5A RS232 ETHERNET CIRWATT B 410-T5A-A0B00 B680 B / 2 2 50 Hz 3x230/400 V /5A RS485 ETHERNET CIRWATT B 410-T5A-D0B00 B690 B / 2 2 50 Hz 3x127/220 V /5A RS232 RS232 CIRWATT B 410-NT5A-70B00 BF60 B / 2 2 50 Hz 3x127/220 V /5A RS485 RS485 CIRWATT B 410-NT5A-80B00 BFA0 B / 2 2 50 Hz 3x127/220 V /5A RS232 RS485 CIRWATT B 410-NT5A-90B00 BF70 B / 2 2 50 Hz 3x127/220 V /5A RS232 ETHERNET CIRWATT B 410-NT5A-A0B00 BF80 B / 2 2 50 Hz 3x127/220 V /5A RS485 ETHERNET CIRWATT B 410-NT5A-D0B00 BF90 1-12

.1 CIRWATT B III Three-phase energy meter References Class (Active/ Reactive) uadrants Frequency (Hz) Measuring range V Measuring range A Communication COM1 Communication COM2 Code B / 2 4 50 Hz 3x230/400 V 10 (100)A RS232 RS232 CIRWATT B 410-D1A-70B10 B4A0 B / 2 4 50 Hz 3x230/400 V 10 (100)A RS485 RS485 CIRWATT B 410-D1A-80B10 B4E0 B / 2 4 50 Hz 3x230/400 V 10 (100)A RS232 RS485 CIRWATT B 410-D1A-90B10 B4B0 B / 2 4 50 Hz 3x230/400 V 10 (100)A RS232 ETHERNET CIRWATT B 410-D1A-A0B10 B4C0 B / 2 4 50 Hz 3x230/400 V 10 (100)A RS485 ETHERNET CIRWATT B 410-D1A-D0B10 B4D0 B / 2 4 50 Hz 3x127/220 V 10 (100)A RS232 RS232 CIRWATT B 410-ND1A-70B10 B740 B / 2 4 50 Hz 3x127/220 V 10 (100)A RS485 RS485 CIRWATT B 410-ND1A-80B10 B7E0 B / 2 4 50 Hz 3x127/220 V 10 (100)A RS232 RS485 CIRWATT B 410-ND1A-90B10 B7B0 B / 2 4 50 Hz 3x127/220 V 10 (100)A RS232 ETHERNET CIRWATT B 410-ND1A-A0B10 B7C0 B / 2 4 50 Hz 3x127/220 V 10 (100)A RS485 ETHERNET CIRWATT B 410-ND1A-D0B10 B7D0 B / 2 4 50 Hz 3x230/400 V /5A RS232 RS232 CIRWATT B 410-T5A-70B10 B860 B / 2 4 50 Hz 3x230/400 V /5A RS485 RS485 CIRWATT B 410-T5A-80B10 B8A0 B / 2 4 50 Hz 3x230/400 V /5A RS232 RS485 CIRWATT B 410-T5A-90B10 B870 B / 2 4 50 Hz 3x230/400 V /5A RS232 ETHERNET CIRWATT B 410-T5A-A0B10 B880 B / 2 4 50 Hz 3x230/400 V /5A RS485 ETHERNET CIRWATT B 410-T5A-D0B10 B890 B / 2 4 50 Hz 3x127/220 V /5A RS232 RS232 CIRWATT B 410-NT5A-70B10 BG60 B / 2 4 50 Hz 3x127/220 V /5A RS485 RS485 CIRWATT B 410-NT5A-80B10 BGA0 B / 2 4 50 Hz 3x127/220 V /5A RS232 RS485 CIRWATT B 410-NT5A-90B10 BG70 B / 2 4 50 Hz 3x127/220 V /5A RS232 ETHERNET CIRWATT B 410-NT5A-A0B10 BG80 B / 2 4 50 Hz 3x127/220 V /5A RS485 ETHERNET CIRWATT B 410-NT5A-D0B10 BG90 B / 2 4 50 Hz 3x63,5/110 V /5A RS232 RS232 CIRWATT B 410-MT5A-70B10 BH20 B / 2 4 50 Hz 3x63,5/110 V /5A RS485 RS485 CIRWATT B 410-MT5A-80B10 BH60 B / 2 4 50 Hz 3x63,5/110 V /5A RS232 RS485 CIRWATT B 410-MT5A-90B10 BH30 B / 2 4 50 Hz 3x63,5/110 V /5A RS232 ETHERNET CIRWATT B 410-MT5A-A0B10 BH40 B / 2 4 50 Hz 3x63,5/110 V /5A RS485 ETHERNET CIRWATT B 410-MT5A-D0B10 BH50 1-13

.1 CIRWATT B III Three-phase energy meter Dimensions Terminal cover option 6 11 67 Wire cover option 6 11 67 172 205,5 172 255 6 6 18 150 67 51,2 172 150 172 67 Conections CIRWATT B III direct connection CIRWATT B III indirect connection 2 5 8 1 3 4 6 7 9 10 12 1 2 3 4 5 6 7 8 9 11 L1 L2 L3 N L1 L2 L3 N S1 S2 S1 S2 P1 P2 S1 S2 P1 P2 P1 P2 1-14

.1 CIRWATT C Digital multi-function three-phase meter Description Features Digital multi-function three-phase meter, with 2 or 4 quadrants, with type-1 accuracy in active energy and type-2 accuracy in reactive energy, direct or indirect metering, with the possibility of programming up to 3 contracts. In accordance with the demands and needs of the electricity market, CIRCUTOR has included 2 communications ports (on demand), respecting the IEC and MODBUS communications protocols. It is committed to future technologies, adapting a range of C meters to the new communications system, PLC. The main display shows the following visual indicators in standby mode: Energy direction Reactive capacitive / reactive uadrant being used Phases activated and their direction Active rate per contract The meter also has 3 alarms to indicate the status of the contact or the installation: critical, non-critical and battery. Application CIRWATT C is ideal for LV and MV power supplies up to 450 kw. Special 4 meter for FV plants, with an endless number of communications options. Power supply circuit Self-powered Nominal voltage Multi-range, from 3x57.7/100 V to 3x230/400 Vac Tolerance ± 20 % Consumption < 2 W / 10 V A Frequency 50... 60 Hz Operating temperature - 20 ºC... + 60 ºC Metering circuit Connection 3 or 4 wires from the same unit Reference voltages Multi-range, from 3x57.7/100 V to 3x230/400 Vac Frequency 50... 60 Hz Current circuit Nominal base currents.../5 or.../1 A (indirect metering; 10 A (direct metering) Maximum current 10 or 2 A (2 x I n ) (indirect metering); 100 A (10 x I n ) (direct metering) Accuracy Active Energy Class 1 (IEC 61036) Reactive Energy Class 1 (IEC 61268) Data memory FLASH (non-volatile memory) Events: 512 records / Billing closing: 64 / Capacity Load curve: 213 days / 2nd programmable load curve: 5,120 records Clock maintenance battery Working Life Operation with no battery or voltage Clock Lithium 10 years (50% load) Maximum 24 hours uartz oscillator / grid synchronism (adjustable by the programmer) uartz oscillator drift < 0.5 s/day at 25 ºC Digital inputs (on demand) Digital outputs (on demand) Verification LED output Rate Communications 4 inputs (60...300 Vac) 3 mechanical relay outputs (up to 400 Vac) optomos 20 000 impulses / kw h or kvar h, in terms of secondary values (indirect metering); 1 000 impulses / kw h (direct metering) Optical interface COM 1 Protocols IEC-61107 RS-232 / RS-485 / Ethernet / PLC (depending type) IEC-870-5-102, IEC-61107 Build features Enclosure In compliance with DIN 43859 Weight 1.9 kg 1-15

.1 CIRWATT C Digital multi-function three-phase meter Dimensions Standards IEC60687 Static active energy meters for ac, Class 0.5S, 0.2S IEC61036 Static active energy meters for ac, Class 1 IEC61268 Static reactive energy meters for ac, Class 1 and 2 EN -50081-1 EN -50082-2 EN 55022 EN 61000-4-6 EN 61000-4-8 Residential emissions Industrial immunity Driven emissions: Class B / Radiated emissions: Class B Immunity to RF fields coupled to cables (common mode): 10 V Immunity to magnetic fields and grid frequency: 30 A/m Connections 3 / 4 Wire Connection (LV) 3 Wire Connection (MV) 3 Wire Connection (MV) Direct metering 1-16

.1 CIRWATT C Digital multi-function three-phase meter References Class (active/reactive) uadrants Measuring range V Measuring range A Input / Output relays Input impulses Communication COM1 Communication COM2 Code Standard 1/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 - CIRWATT C 410-UD1C-10C0 1C521 1/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - RS485 - CIRWATT C 410-UD1C-20C0 1C525 1/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - ETHERNET - CIRWATT C 410-UD1C-30C0 1C52D 1/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 RS232 CIRWATT C 410-UD1C-70C0 1C52W 1/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - RS485 RS485 CIRWATT C 410-UD1C-80C0 1C52U 1/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 RS485 CIRWATT C 410-UD1C-90C0 1C52T 1/2 2 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 ETHERNET CIRWATT C 410-UD1C-A0C0 1C52V 1/2 2 3x57/110 V a 3x230/400 V /5A - - RS232 - CIRWATT C 410-UT5C-10C0 1C511 1/2 2 3x57/110 V a 3x230/400 V /5A - - RS485 - CIRWATT C 410-UT5C-20C0 1C515 1/2 2 3x57/110 V a 3x230/400 V /5A - - ETHERNET - CIRWATT C 410-UT5C-30C0 1C51D 1/2 2 3x57/110 V a 3x230/400 V /5A - - RS232 RS232 CIRWATT C 410-UT5C-70C0 1C51W 1/2 2 3x57/110 V a 3x230/400 V /5A - - RS485 RS485 CIRWATT C 410-UT5C-80C0 1C51U 1/2 2 3x57/110 V a 3x230/400 V /5A - - RS232 RS485 CIRWATT C 410-UT5C-90C0 1C51T 1/2 2 3x57/110 V a 3x230/400 V /5A - - RS232 ETHERNET CIRWATT C 410-UT5C-A0C0 1C51V 4 quadrants - Energy generation 1/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 - CIRWATT C 410-UD1C-10C1 1C421 1/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - RS485 - CIRWATT C 410-UD1C-20C1 1C425 1/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - ETHERNET - CIRWATT C 410-UD1C-30C1 1C42D 1/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 RS232 CIRWATT C 410-UD1C-70C1 1C42W 1/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - RS485 RS485 CIRWATT C 410-UD1C-80C1 1C42U 1/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 RS485 CIRWATT C 410-UD1C-90C1 1C42T 1/2 4 3x57/110 V a 3x230/400 V 10 (100)A - - RS232 ETHERNET CIRWATT C 410-UD1C-A0C1 1C42V 1/2 4 3x57/110 V a 3x230/400 V /5A - - RS232 - CIRWATT C 410-UT5C-10C1 1C411 1/2 4 3x57/110 V a 3x230/400 V /5A - - RS485 - CIRWATT C 410-UT5C-20C1 1C415 1/2 4 3x57/110 V a 3x230/400 V /5A - - ETHERNET - CIRWATT C 410-UT5C-30C1 1C41D 1/2 4 3x57/110 V a 3x230/400 V /5A - - RS232 RS232 CIRWATT C 410-UT5C-70C1 1C41W 1/2 4 3x57/110 V a 3x230/400 V /5A - - RS485 RS485 CIRWATT C 410-UT5C-80C1 1C41U 1/2 4 3x57/110 V a 3x230/400 V /5A - - RS232 RS485 CIRWATT C 410-UT5C-90C1 1C41T 1/2 4 3x57/110 V a 3x230/400 V /5A - - RS232 ETHERNET CIRWATT C 410-UT5C-A0C1 1C41V Inputs / outputs 1/2 2 3x57/110 V a 3x230/400 V 10 (100)A 4 / 3 Opto RS232 - CIRWATT C 410-UD1C-14C0 1C522 1/2 2 3x57/110 V a 3x230/400 V 10 (100)A 4 / 3 Rele RS232 - CIRWATT C 410-UD1C-15C0 1C523 1/2 2 3x57/110 V a 3x230/400 V 10 (100)A 4 / 3 Opto RS485 - CIRWATT C 410-UD1C-24C0 1C526 1/2 2 3x57/110 V a 3x230/400 V 10 (100)A 4 / 3 Rele RS485 - CIRWATT C 410-UD1C-25C0 1C527 1/2 2 3x57/110 V a 3x230/400 V /5A 4 / 3 Opto RS232 - CIRWATT C 410-UT5C-14C0 1C512 1/2 2 3x57/110 V a 3x230/400 V /5A 4 / 3 Rele RS232 - CIRWATT C 410-UT5C-15C0 1C513 1/2 2 3x57/110 V a 3x230/400 V /5A 4 / 3 Opto RS485 - CIRWATT C 410-UT5C-24C0 1C516 1/2 2 3x57/110 V a 3x230/400 V /5A 4 / 3 Rele RS485 - CIRWATT C 410-UT5C-25C0 1C517 1-17

.1 CIRWATT D High-performance, multi-function static meter Description Features High-accuracy meter, metering in 4 quadrants and offering the maximum programming and communications flexibility, in order to cater for any type of requirement. The best option for large-scale consumers. The meter has an LCD display with 3 lines, where all parameters are displayed on 2 buttons. The main display shows the following visual indicators in standby mode: Energy direction Reactive capacitive / reactive uadrant being used Phases activated and their direction Active rate per contract The meter also has 3 alarms to indicate the status of the contact or the installation: critical, non-critical and battery. Application It has been specially designed for installations that require: billing by contract, dual load profile or various remote metering systems operating in parallel. It adapts to the needs of each client, thanks to the many different communications ports and protocols. RS-232 - RS-232 RS-232 - RS-485 RS-232 - ETHERNET Power supply circuit Self-powered Nominal voltage Depending on the type Consumption < 2 W / 10 V A Frequency 50 or 60 Hz (depending on the type) Operating temperature - 20 ºC... + 60 ºC Metering circuit Connection 3 or 4 wires from the same unit Reference voltages 3x63.5/110 V, 3x110/190 V, 3x127/220 V, 3x230/400 V (depending on the type) Frequency 50 or 60 Hz Current circuit Nominal base currents.../5 or.../1 A (indirect reading) Maximum current 10 or 2 A (2 x I n ) (indirect reading) Accuracy Active Energy Class 1 (IEC 61036); Class 0.2S or 0.5S (IEC 60687) Reactive Energy Class 0,5 or 1 (IEC 61268); Class 2 (61268) Data memory FLASH (non-volatile memory) Events: 512 records / Billing closing: 64 / Capacity Load curve: 213 days / 2nd programmable load curve: 5,120 records Clock maintenance battery Working Life Operation with no battery or voltage Lithium 10 years (50% load) Maximum 24 hours Clock Grid frequency / quartz oscillator uartz oscillator drift < 0.5 s/day at 25 ºC Digital inputs (on demand) 3 inputs (60...300 Vac) Digital outputs (on demand) 3 mechanical relay outputs (up to 400 Vac) optomos (depending on the type) Verification LED output Rate Communications Optical interface COM 1 COM 2 20 000 impulses / kw h or kvar h, in terms of secondary values IEC-61107 - Reading / Programming RS-232 - Reading / Programming RS-232 / RS-485 - Reading Protocols IEC-870-5-102, Modbus-RTU, IEC-61107 Build features Enclosure In compliance with DIN 43859 Weight 2.2 kg 1-18

.1 CIRWATT D High-performance, multi-function static meter Dimensions Standards IEC 60687 Static active energy meters for ac, Class 0.5S, 0.2S IEC 61036 Static active energy meters for ac, Class 1 IEC 61268 Static reactive energy meters for ac, Class1 and 2 EN-50081-1 EN-50082-2 EN 55022 EN 61000-4-6 EN 61000-4-8 Residential emissions Industrial immunity Driven emissions: Class B / Radiated emissions: Class B Immunity to RF fields coupled to cables (common mode): 10 V Immunity to magnetic fields and grid frequency: 30 A/m Connections 3 / 4 Wire Connection (LV) 3 Wire Connection (MV) 3 Wire Connection (MV) 3 ARON Wire Connection (MV) 1-19

.1 CIRWATT D High-performance, multi-function static meter References Consumer type Class uadrants Metering range V Metering range A OptoMOS Input / Output Relay Input / Output COM1 COM2 TYPE code STANDARD 2 0.5S 4 3x63.5/110 V... / 5 A - - RS232 RS232 CIRWATT D 405-MT5A-10D 1D251 2 0.5S 4 3x63.5/110 V... / 5 A - - RS232 RS485 CIRWATT D 405-MT5A-20D 1D255 2 0.5S 4 3x63.5/110 V... / 5 A - 3/4 RS232 RS232 CIRWATT D 405-MT5A-15D 1D253 2 0.5S 4 3x63.5/110 V... / 5 A 3/4 - RS232 RS232 CIRWATT D 405-MT5A-14D 1D252 2 0.5S 4 3x63.5/110 V... / 5 A - 3/4 RS232 RS485 CIRWATT D 405-MT5A-25D 1D257 2 0.5S 4 3x63.5/110 V... / 5 A 3/4 - RS232 RS485 CIRWATT D 405-MT5A-24D 1D256 1 0.2S 4 3x63.5/110 V... / 5 A - - RS232 RS232 CIRWATT D 402-MT5A-10D 1D051 1 0.2S 4 3x63.5/110 V... / 5 A - - RS232 RS485 CIRWATT D 402-MT5A-20D 1D055 1 0.2S 4 3x63.5/110 V... / 5 A - 3/4 RS232 RS232 CIRWATT D 402-MT5A-15D 1D053 1 0.2S 4 3x63.5/110 V... / 5 A 3/4 - RS232 RS232 CIRWATT D 402-MT5A-14D 1D052 1 0.2S 4 3x63.5/110 V... / 5 A - 3/4 RS232 RS485 CIRWATT D 402-MT5A-25D 1D057 1 0.2S 4 3x63.5/110 V... / 5 A 3/4 - RS232 RS485 CIRWATT D 402-MT5A-24D 1D056 Indicate: Distribution, area, hourly discrimination and current transformer ratio, if applicable. Three-phase meters with additional features ETHERNET COMMUNICATIONS 2 0.5S 4 3x63.5/110 V... / 5 A - - RS232 Ether. CIRWATT D 405-MT5A-30D 1D25E 1 0.2S 4 3x63.5/110 V... / 5 A RS232 Ether. CIRWATT D 402-MT5A-30D 1D05E FOR OTHER CONFIGURATIONS (inputs, outputs and other communications), PLEASE ASK 1-20

.1 PLC-800 Concentrator for PLC systems Description Features The product proposed by CIRCUTOR, S.A as the lead device for reading energy meters with PLC communications - either three-phase or single-phase - connected to the low-voltage mains, and normally located within a substation - either interior or exterior - is the PLC-800 concentrator. This device can connect to different communications systems, such as PLC (Power Line Carrier), Ethernet, GSM and GPRS. These communications offer different options to the PLC800 concentrator, so that it can communicate with the concentrator, either with the purpose of configuring the concentrator or to send the information automatically to a server. General Reference voltage Operating limit voltage Reference frequency 3x230/400 V or 3x127/220 (3/4 wires) 440 V during 6 hours 50 Hz Minimum temperature - 25 ºC Maximum temperature IP protection IP 51 Clock Memory Communications Display + 70 ºC, 95 % of relative humidity Automatic daily synchronisation SD (512 Mb) 1,000 meters 20 years without maintenance 1 Ethernet port 2 USB ports 1 GSM/GPRS modem port Colour LCD Buttons 2 buttons for navigating through screens Application The main objective is to gather the data from the meters through PLC communications, i.e., through the power grid. The installation of the PLC-800 must be the header of the distribution line, near the medium voltage transformer, connected to the low voltage line. The unit has a colour screen, which can be used to configure the different communication parameters and data related to the files stored, as well as to display a list of the meters that are connected correctly; or with a deviation of more than 6 hours, or a difference of 24 h, identified by different colours. It is a Plug&Play system, so that the meters are detected automatically by the concentrator when they are installed in the grid. The concentrator then starts to download all data in the memory of the meters, including energy load curves, events and billing closing, up to the current date. On the other hand, the PLC-800 uses different routines that, for example, send the data downloaded from the meters every day to an FTP server, adding the new file with the daily energy summary of all meters 1-21

.1 PLC-800 Concentrator for PLC systems Dimensions References Power supply voltage 127... 230 Vac PLC Communications band Metering voltage 3x230/400 V Number of PLC Communications inputs GSM/GPRS Modem USB Ports Ethernet Port A 1 2 1 PLC800-U-1-2M00-12-0 45210 B 1 2 1 PLC800-U-1-4M00-12-0 45310 A 2 2 1 PLC800-U-1-2M2M-12-0 45211 Code Connections Transf 2 Transf 1 Alimentación A1 A2 L1 L2 L3 N L1 L2 L3 N opcional 1-22

.1 Relation between products and accessories Converters TRMC Modem LOC LM4-PLC Software Communications converters Current transformers GSM, RTC, protector Optical reader Impulse concentrator Management and control Software See M.5 See.3 See.3 See.3 See.3 See.3 CIRWATT A - - - CIRWATT B - - - CIRWATT C CIRWATT D PLC-800 - - - - 1-23

.1 1-24