Performing Arts Theatre

Similar documents
NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Technical Information

FOX THEATRE ST. LOUIS

Patriots Theater at the War Memorial Technical Data

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

ARTPARK MAINSTAGE THEATER TECHNICAL PACKET

Tucker Theatre Policies and Procedures MTSU Department of Theatre 205 Boutwell Dramatic Arts Murfreesboro, TN 37132

Sandusky State Theatre Technical Specifications

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

Technical Specifications. Taylor Little Theater

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Technical Specifications

SHUBERT THEATER 247 College Street, New Haven, CT

TECHNICAL PACKAGE.

PRODUCTION INFORMATION

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Technical Information

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

Arcadia Performing Arts Center Technical Specifications and Information

Concert Hall Technical Specifications

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

Technical Specifications

Technical Specifications

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

Concert Hall Technical Specifications

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Technical Specifications

THEATRE PROJECTS. Parts of a Theatre Building

TECHNICAL INFORMATION & SERVICES

Technical Specifications

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

THE BELDING THEATER. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

Lighting Information

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Technical Specifications and Inventory Spring 2018

The Breen Center for the Performing Arts Saint Ignatius High School

Main Stage Technical Specs - Hall #2

SAINT ANSELM COLLEGE DANA CENTER

FIVE FLAGS THEATER SERVICES STATEMENT

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Marjorie S. Deane Little Theater

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

1/16 Virginia Tech/Blacksburg, VA/Haymarket Theatre

P.O Box 1171 Box Office & Theatre: (903) Main St Texarkana, TX TRAHC Office: (903) Texarkana, TX Fax: (903)

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

NORTH CHARLESTON PERFORMING ARTS

Technical Specifications

NORTH CHARLESTON PERFORMING ARTS

PRODUCTION PHONE NUMBERS:

Theater Technical Information

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

Facility Technical Information

THE MORTENSEN HALL. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

Contact Information. Karen Jones Accounting Specialist Phone:

SECREST AUDITORIUM TECHNICAL PACKAGE

Technical Services and Specification

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

THEATRE TECH MANUAL. Location and Mailing Address: Irving Arts Center 3333 North MacArthur Suite 300 Irving, Texas 75062

Bartlesville Community Center

Struthers Library Theatre

Venue and Production Information

Technical Specifications

Baker Hall Technical Information Package

Front of House Information HUMANITIES THEATRE University of Waterloo

DeVos Performance Hall

Princess of Wales. General Info and Technical Package

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Latrobe Performing Arts Centre

Arie Crown Theater Marketing Package

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS

TECHNICAL INFORMATION DRIVING DIRECTIONS

Facility Information

Downtown Arts Center Tech Packet. General Information

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

MODELL PERFORMING ARTS CENTER AT THE LYRIC

Jacoby Auditorium - Technical Rider UCC Special Events Office Phone:

Center Theater Technical Information 9/1/12

CENTRE FOR PERFORMING ARTS

Dale F. Halton Theater Technical Specifications

Bologna Performing Arts Center Technical Information Package Delta & Pine Land Theatre

Shouson Theatre Venue Specifications (updated Jan 2017)

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

Technical Information Package

Smothers Theatre Technical Specifications Pepperdine University

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

TECHNICAL SPECIFICATIONS AND INVENTORY PANTAGES THEATER

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Vern Riffe Center for the Arts Technical Information Packet for Users Seating capacity Stage configuration CONCERT HALL PROSCENIUM THEATER

Centennial Hall Technical Information

Transcription:

House Seating Total Seating: 2,148 o Orchestra: 1,281 (60 located in pit) o Loge: 282 o Upper Balcony: 525 Performing Arts Theatre House Measurements Distance from stage front to first beam ceiling is 56 ft. Distance from stage front to second beam ceiling is 72 ft. Distance from stage front to sound and light room is 130 ft. Distance from plaster line to stage slots is 4 Distance from plaster line to balcony slots is 30 Distance from plaster line to first beam ceiling is 64 Distance from plaster line to second beam ceiling is 80 Distance from plaster line to sound and light room is 130 Mezzanine One permanent concession stand located on mezzanine level Ample space for catered post or pre-event hospitality Two (2) portable concession stands may be used for events Lobby Two Permanent box offices, one each located on either side of the main lobby entrance Handicap Access Handicapped accessible through orchestra level portals 11 & 12 Handicap restrooms available in lobby Elevator allows wheelchair access to mezzanine, but not to seating areas. A Genie personal lift is needed for handicap stage access with advanced notice Assisted Listening Devices available upon request Load-In Area One (1) loading door (Clear Width-10, Clear Height-9 8 ) located stage left Can accommodate two (2) tractor-trailers directly at dock 2 10 dock plates available Stage level inside Off-stage storage for crates Ample on-site parking for company buses and tractor-trailers Version 8.10 14

Stage Dimensions Overall stage dimensions are 105 wide x 54 ½ deep Usable stage width is 93 ft. Height of proscenium opening has a maximum of 26 and a minimum of 15 Width of proscenium opening has a maximum of 56 9 and a minimum of 36 Distance from main curtain to back wall is 46 Distance from main curtain to front edge of stage is 8 ½ Distance from main curtain to black curtain is 36 Wing space on stage right is 25 x 55 and on stage left is 20 x55 Apron is 864 sq. ft. (9-12 ft. deep x 72 wide; 7 ½ at center) Upstage side of SR proscenium wall is plaster line There is access from backstage to the front of the house. No large obstructions backstage. Approximately 12 walking space behind upstage black curtain 8 feet from edge of stage to center of fire curtain pocket (plaster line may be considered 6 further upstage to downstage playing wall), measured from center stage Distance from front curtain to back wall is 46 ft.; curtain to front stage edge in center is 8 ½ ft. Stage Floor Construction is of soft pine, stained mahogany, level, and free from sagging trap doors Floor laid on concrete with exception of center area & non-trappable Tape may be used to lay a ground cloth Nails, stage screws, and leg bolts may be used, if plugged afterwards Stage Power Three 400 amp three phase connects located downstage left, same ground. One 200 amp available outside on the dock. May be used for shore power or be brought in for stage as required with distribution panel. Three buses can safely hook up to this panel with each bus using 50 amps or less. Orchestra Pit Dimensions are 15 6 at center by 65 wide Pit is on hydraulic lift and may be positioned at 4 predetermined heights from basement to stage level Musicians may enter pit from performance level or basement Pianos available are Steinway Concert Grand, Steinway Baby Grand, and Yamaha Upright Dressing Rooms There are seven (7) dressing rooms total: o Two (2)- Two (2) person rooms o Three (3) Three (3) person rooms o Two (2) Thirty-two (32) person rooms All dressing rooms on stage level. All dressing rooms equipped with lighted mirrors, chairs, vanity tables, clothes racks, sinks, toilets, & showers (one dressing room has washer and dryer) Basement room for musicians Wardrobe room (12 x 16 ) on rear stage walk around No Green Room for dancers No hook-ups for portable washer or dryer, slop-sink, irons, or ironing boards Version 8.10 15

House Draperies Front Curtain on Traveler or Guillotine, hand-operated from stage right Two (2) back drops; one (1) black and one (1) blue cyclorama Four sets of Legs, black, 12 wide x 30 high Four borders, black fullness not sewn in, 60 wide x 5 high Stage Rigging Working height of grid is 66ft. Forty-four (44) total sets of lines; thirty-seven (37) lines may be cleared for sue with effort Fly system is counterweight, single purchase, hand operated All pipes may be lowered to a reasonable working height from the floor The capacity of each line set after balancing pipe weight is 1000 lbs. with sufficient weights to fully counter-balance each line at a maximum Distance from last set to back wall is 10 Pipes are 60 in length, approximately 2 in diameter All battens may be cleated Locking rail and pin rail located stage right, 26 above floor Counter weight arbors hold approximately 1,050 lbs. after batten weight Sound Permanent System: Soundcraft 200 Delta 24 x 4 x 2: o 12 input channels, 1 output channel o 600 ohm per channel, no equalizers o 2 SM 57 microphones o 12 SM 58 microphones o 5- Floor stands o 4-15 70v speakers Tape: Otari MX5050 Reel-to-Reel, 7 ½ ips and 15 ips Intercom system: Clear-Com 3-pin; 20 headsets o Lines to Light Booth, Fly Floor, Sound Booth, Follow Spots, Stage Right, Stage Left, House, and Projection Room o P.A. system available from backstage through main sound system o Chimes to signal audience at end of intermission o No paging system or program sound to dressing rooms Assisted Listening Devices available upon request 215 cable required to reach house sound location at rear of house, and must be run under the seating area per the fire Marshal Standard available space for mix position is 17 wide x 9 deep located at rear of house Version 8.10 16

General Lighting Show Board is located stage left Three 400-amp circuits available on stage for Road Board use 110 and 208 voltage available for boards Dimmer board has 52-6KW 8-12KW Non-Dims: 5-6KW 5-12KW Circuits per dimmer vary according to wattage ETC Insight, 108 channels/submasters House board is located in the rear of the Performing Arts Theatre Permanent front of house lighting controlled from lobby All light plugs are twist-lock 3-pin ground (can convert to stage pin) old style, pin out twist There are separate work lights House lights are controlled from stage right and front of house and are on dimmers (dimmers do not transfer to control stage lights) 1 st beam ceiling lights can hit from stage edge to 35 feet upstage (22 standing coverage) and give a 19 foot circle measured at 20 feet upstage (old majors) 2 nd ceiling beam lights can hit 35 feet upstage (26 standing) from stage edge and give a 15 foot circle measured at 25 feet upstage (old majors) 216 foot cable runs from stage left patch bay corner through house right/stage left audience to the middle support in window of light control booth in the back of the house, taking into account running cable around the handicapped section as you would tape it down Three 400 amp three phase connects located downstage left, same ground. Separate water pipe ground available 15 away in hallway (we have no cable for running a separate ground) Lights on stage that can be rehung: o 10-6 Fresnels 750W o 10 Fresnel 750W o 8- Scoops 1000W o 34-6x9 Lekos 750 o 6-8 Fresnels 750W o 36-1K PAR Cans o 4- Beam Projectors 1000W o 5 ETC 19 degree (6x16) Lekos o 2 ETC 36 degree (6x9) Lekos Lights not movable and location: o 12-12 x 22 1K Major (2 nd Cove ceiling) o 2- Strong supers (Rear balcony) Xenon o 12-8 Leko Kleigs 750W (First cove ceiling) o 12-6 6 x 9 Lekos 750W (Stage slots- left & right- 6 per side) o 12-8 x 16 1K Major (1 st House Cove Ceiling) Additional Lighting and Connections: o 4- Trees- maximum 8 lights per tree o 2- Tormentors- 8 circuits each o 6- Boom boxes- 4 circuits o 9-4 circuit each Floor Pockets rated 20 amps (trip off at 17 amps) Version 8.10 17

Detailed Lighting Instruments non-fixed: scoops 1k-usually for cyc on 2 nd electric winch upstage 14 Altman 6x9 non-axiel quartz 38 PAR64 Black steel cans with 1k mixed mediums and some wides 4-6 Major Fresnels 8 Altman Fresnel 10 ETC Source Four 19 degree- usually located on 2 nd beam 4 ETC Source Four 36 degree 10 Altman 1KAF 6 Fresnels at 750watts Roscolux Gel: o #104 Tough Silk 20 o #26 Light Red 20 o #33 No Color Pink 20 o #12 Straw 20 o #34 Flesh Pink 20 o #27 Medium Red 10 o #80 Primary Blue 20 o #125 Blue Cyc Silk 8 o #65 Daylight Blue 20 o #124 Red Cyc Silk 8 o #54 Special Lavender 20 o #127 Amber Cyc Silk 4 o #57 Lavender 20 o #122 Green Diffusion 1 Lee Filters: o 126 Mauve 10 o #020 Medium Amber 20 o #120 Deep Blue 10 o #089 Moss Green 10 o #201 Full C.T. Blue 4 o #139 Primary Green 10 Adaptors: o 59 male twist to female stagepin (3 conductor) o 25 male twist to female Idison o Transfer panel adapters 33 three conductor male twist to male stagepin, 27 two conductor male twist to male stagepin = total 60 adapters for transfer WE DO NOT STOCK ANY COLOR MEDIA ARRANGEMENTS MUST BE MADE WITH SHOW PRODUCER AND HOUSE FOR THE HOUSE TO BUY ANY IN ADVANCE Version 8.10 18

Patchbay Patchbay list from left to right as you view it. (These are rows of circuits that will give you a better idea of the naming and number of circuits). 1 st beam 1-16 2 nd beam 1-16 Left boom drop box 1-12 (on stage left) 1 st beam 17-18 Right boom drop box 1-12 (on stage right) 2 nd beam 17-18 Performing Arts Theatre slots left 1-8; Performing Arts Theatre slots right 1-8 Stage slots left 1-8; stage slots right 1-8 Balcony left 1-8; balcony right 1-8 1 st light pipe 1-16 1 st light pipe 17-32 (downstage electric winch line #5) 2 nd light pipe 1-12 (upstage winch line #43) 1st light pipe 33-36 2 nd light pipe 13-24 1 st light pipe 37-40 Light pipe drop 1-16 Light pipe drop 17-32 Light pipe drop 33-48 Tormentors left 1-8 (downstage wall) tormentor right 1-8 Floor pocket D 1-4, C 1-4, B 1-4 A 1-4 Floor pocket H 1-4, G 1-4, F 1-4, E 1-4 Lift pocket left 1-2, lift pocket right 1-2, trap 1-4, floor pocket I 1-4 Shell lights 16-1 (1-4 are actual houselights over pit area and are not assignable circuits to other instruments; 5-16 are on two drop boxes and can be put most anywhere on battens on stage left). NOTE: Light pipe boxes 1-48 are 8 circuits to a drop box and are dropped in certain areas in the grid-see RCC Line Plot. Left and right boom drop boxes 1-12 are four doubled circuits to a box and appear on the extreme ends of the pipes/electrics. Version 8.10 19

Line Set #1 Main Curtain 2 House Border 1' 10" 3 Teaser 4 Torm 3' 3" 5 #1 Electric winch 4' 11" 6 5' 5" 7 6' 3" 8 7' 0" 9 7' 8" 10 8' 5" 11 9' 0" 12 Electric 10' 2" 13 10' 10" 14 11' 8" 15 12' 3" 16 12' 11" 17 Electric 14' 3" 18 14' 10 1/2" 19 15' 6" 20 16' 2" 21 17' 0" 22 Mid Stage Traveler 17' 9" Non-transferable 23 18' 4" 24 19' 7" 25 20' 4" 26 Electric 21' 1/2" 27 21' 6 1/2" 28 22' 3" 29 22' 11 1/2" 30 24' 10 1/2" 31 25' 10" 32 26' 5 1/2" 33 27' 2" 34 Electric 27' 9 1/2" 35 28' 6" 36 29' 11" 37 31' 2" 38 #2 Electric winch 32' 2" 39 33' 2" 40 33' 9" 41 34' 7" 42 36' 2" 43 36' 10" 44 37' 7" 45 Black 38' 4" Non-transferable NOTE: There is no line set at #3, #5, or #43; all electric winches. All legs and borders BLACK except main curtain (RED). Version 8.10 20