EVENT INPUT/OUTPUT MODULE [PUME]

Similar documents
Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Wall-/Pipe-Mount Level Indicator

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

DCP100 Digital Control Programmer Specifications

02/11/2015

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Multifunction devices

Accessories. Servo Motors. Servo Motors B-47. Accessories

Preset counters, electronic

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

High performance circuit breakers

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

Magnecraft Power Relays

Fibre Optic Modem ODW-622

Rack mounted telephone- and leased line modem for industrial applications

Fibre Optic Modem ODW-611

Bimetal Temperature Switch

Hybrid Chart Recorder 250 mm (10")

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

DX-10 tm Digital Interface User s Guide

LAUREL ELECTRONICS, INC.

General Specifications

LONWORKS Fibre Optic Router

LONWORKS Fibre Optic Converter

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

ODW-621. RS-232 Point-to-point applications

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Fibre optic router for TP/FT-10 LRW-112PP

Level Measurement silometer FMC 420, FMC 423

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Analogue output module DAO 081

Absolute Encoders Multiturn

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

AF-300 E11 Adjustable Frequency Drive

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Simply clever! The digital DIN-rail time switches by Grässlin

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Process transmitter RMA422

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

actions. 12 digital outputs can be assigned to 4 different types of events (MODE, Alarm, Time and PV) 32 Programs, 800 segments

Generator protection relay

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Lt DELTA USA, Inc

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES

AMX Precis HDBaseT Receiver and Scaler For use with the Precis 8x8 4K60 HDMI matrix switcher PR01-RX (FG )

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

Process Transmitter RMA 422

BUS UNITRONIC BUS CAN

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide

HSR-1 Digital Surveillance Recorder Preliminary

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Absolute Rotary Encoder E6CP

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

Quick Operation Guide of LTN7700/7600 Series NVR

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Aegis Electronic Group

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

INSTALLATION & USER GUIDE

Multifunction Digital Timer

Assembly. Front view. LEDs. Parametrization interface. Power Bus

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

8Ch CWDM 3G-SDI Fiber Extender kit User Manual L-XSDI-CWDM-3G-TX/RX

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

USER S MANUAL. FX2N-8AD Analog input block

ABS ST700 Compact Type Series

SY-HDBT-100 Extender Set

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

CATALOG NUMBER: HK-MX-VGA-X-Y Product Name

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Standard RS232 RS ma

VAT 20 Adjustable Frequency Drive

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Transcription:

PUM Series Multi-loop module type Temperature controller DATA SHEET EVENT INPUT/OUTPUT MODULE [] is a digital input/output module used as an auxiliary input/output of control modules. Each module, 30mm wide, is equipped with 8 points of digital input, 8 points of digital output, and high-speed RS-485 port. By connecting with PUM control modules, it realizes a compact and highperformance system. FEATURES I. User-friendly structure and functions 1. Lateral connection : Max.16 units + control module 16 units = total 32 units Simple wiring for power supply and communication 2. Detachable structure: Terminal block, main unit, and the base part Easy wiring with detachable terminal blcok Main units exchangeable without re-wiring 3. Status LED for each input/output Easy to monitor input/output status 4. Smart loader communication: Connect one module and all connected modules are able to communicate using a loader software. II. Large scale system using high speed RS-485 1. Modbus RTU protocol for large volume communication 2. High-speed communication: Maximum 115.2kbps 3. Highly-efficient communication: Parameters dispersed on the address map are re-allocated to contiguous address III. Various functions to extend control module functions 1. Digital input (Optional feature : logic operation NOT/AND/OR) <Functions set by DI function of control module> - Run / Standby switch - Auto / Remote / Manual switch - Start timer - Others 2. Digital output (Optional feature : logic operation NOT/AND/OR) - Control output (including distribution output) - Alarm output - Timer output - Others SYSTEM SPECIFICATION 1. Product type: Multi-loop module type temperature controller 2. Module type 1) Analog module: Total maximum 16 units a) Control module (4 loop/unit) b) Extended input/output module - Analog input/output module (Input/output 4 points/unit) - Analog input module (Input 4 points/unit) - Analog output module (output 4 points/unit) 2) Extended input/output (digital) module: Maximum 16 units - Event input/output module (Input/output ; 8 points/unit) 3) Enhanced communication module: 1 unit 3. Connecting method: Lateral connecting with connectors - For power supply and RS-485 communication, any one of connected modules is required to be connected. 4. No. of loop, input/output 1) Control loop: Max. 64 2) No.of input/output: DI 128 points / DO 128 points EDS11-167a Date Apr. 1, 2011

EVENT INPUT/OUTPUT MODULE SPECIFICATION 1. General specification (1) Power supply: 24V DC ±10% (2) Power consumption: Max. 3.2 W (135 ma) [when 24V DC is applied] (3) Insulation resistance: 20M or more (500V DC) (4) Withstand voltage: Power supply digital input digital output communication terminal 1000V AC 1 min. Others (digital input between blocks, digital output between blocks) 500V AC 1 min. (5) Applied standards: UL, C-UL, CE marking, RoHS directive [Pending for UL, C-UL marking] 2. Digital Input (1) No. of input: 8 points (4 points/common 2 blocks) (2) Input type: Voltage contact input, sink/source common (bidirectional) (3) Input rating: 24V DC, input impedance approx. 4.7k (4) Input judgment: ON judgment: 16 to 26.4V DC OFF judgment: 0 to 5V DC (5) Input read cycle (min. pulse width): 200ms (6) Insulation: Functional insulation with internal circuit (7) Option: NOT/AND/OR logic operation, Latch action 3. Digital Output (1) No. of output: 8 points (4 points/common 2 blocks) (2) Output type: Select from a) and b) according to model type specification a) Relay contact output - Contact structure: SPST contact - Contact capacity: 220V AC/30V DC, 1A - Insulation: Functional insulation with internal circuit b) Transisitor open collector (sink) output - Rating: 24V DC, 100mA (Residual voltage when power is ON: 1.5V DC or less) - Insulation: Functional insulation with internal circuit (3) Option: Control output/event output selection, NOT/AND/OR logic operation, Latch action 4. Communication function 4.1 RS-485 interface (1) Communication standards: RS-485 compatible (2) No. of port: 1 port (3) Communication, synchro method: Two-wire, half-duplex, asynchronous cycle (4) Communication speed: 9.6k, 19.2k, 38.4k, 115.2kbps (5) Communication distance: 1km (38.4kbps or less), 250m (115.2kbps) (6) Recommended cable: KPEV-SB 0.5sq-equivalent (7) No. of connectable units: 33 units (master and slave) (32 units if any modules other than PUM series are included in slaves.) (8) Data format: Data bit; 8, parity; even / odd / none (9) Protocol: Modbus RTU compatible (10) Insulation: No insulation with loader communication port Functional insulation with any other input/output 4.2 Loader communication (RS-232C) interface (1) Communication standards: RS-232C compatible (2) No. of port: 1 port (3) Communication, synchro method: Half-duplex, asynchronous cycle (4) Communication speed: 19.2kbps (fixed) (5) Data format: Data bit 8, no parity (6) Protocol: Modbus RTU compatible (7) Connection method: 2.5 diameter mini-plug/jack [on the front of the module] (Common cable with PXG, PXH) (8) Insulation: No insulation with RS-485 Functional insulation with any other input/output 5. Display, configuration 5.1 Display (1) Display: Status display LED (2 colors 2 points + 16 points) (2) Display contents: RUN/FAULT, RS-485 TX/RX, Input 8 points, output 8 points 5.2 Setting device (1) Setting device: Rotary SW 1 [on the front of the module] (2) Set contents: RS-485 Station No. (Station No.= setting value + 17) 6. Power outage (1) Impact of power outage: Outage of 2ms or less ; no impact (2) Operation after power outage: Start from the first step (cold start) (3) Memory backup: Nonvolatile memory (EEPROM) No. of update ; 100,000 7. Self diagnosis Diagnosis method: Program error monitoring by watch dog timer 8. Structure (1) Installation method: DIN rail mounting or mounting with M3 screws inside a cabinet (2) Dimensions: 30 (W) 100 (H) 85 (D) mm (excluding terminal cover and projected part) (3) Weight: Approx. 200 g 2

(4) Extrenal terminal - Digital input / digital output: Detachable terminal block (M3 screw 20 terminals) - Power supply connection: Terminal block on the base part (M3 screw 2 terminals) Power is supplied via side connectors in case of lateral connecting. (Max. 33 units) - RS-485 communication connection: Terminal block on the base part (M3 screw 3 terminals) RS-485 communication is connected via side connectors in case of lateral connecting. - Loader communication port: 2.5 diameter mini-plug/jack [on the front of the module] (5) Case material: Polyphenylene oxide (flame retardant grade : UL94V-0 equivalent) (6) Case color: Case ; red Terminal, base part ; black (7) Protection - Body: IP20 grade protection (ventilation slits on the top and the bottom of the body) - Terminal: IP00 grade protection, terminal cover is available as an option 9. Normal operating condition (1) Ambient temperature*: -10 to 50 C * Ambient temperature is the temperature underneath the controller inside the equpiment or the cabinet where the controller is installed. (2) Ambient humidity: 90% RH or less (non condensing) (3) Vibration: 10 to 70Hz, 9.8m/s 2 (1G) or less 10. Transporting, storage condition (packing condition) (1) Storage temperature: -20 to 60 C (2) Ambient humidity: 90%RH or less (no condensing) (3) Vibration: 10 to 70Hz, 9.8m/s 2 (1G) or less (4) Shock: 294m/s 2 (30G) or less 11. Packing list Temperature controller: 1unit Instruction manual: 1 copy 12. Loader software (1) Distribution medium: Free download from Fuji Electric Systems HP (http://www.fic-net.jp/eng/index. html) (2) Recommended operating environment PC: DOS/V (PC-AT compatible) OS: Windows XP (operation confirmed in Japanese / English) RAM: 256M bytes or more Free space on the hardware: 500M bytes or more Display resolution: 1024 768 or over Serial interface: RS-232C 1 port (without RS-232C, USB serial converter cable required) (3) Connection with PUM Via loader interface on the front face of the module (special cable available from Fuji is required) or via RS-485 3

CODE SYMBOLS [Event input/ouput module] Digit Description 4 < Module type > Event input/output module [Di 8 points /Do8points] 5 < Output type > Transisitor open collector (sink) output Relay contact output 10 <Operation manual > Japanese English 1 2 3 4 5 6 7 8 9 10 Digit PUM YY1 0 E C R A B [Accessories] Digit Description 6 RS-485 terminating resistance 7 DIN rail mounting end plate 8 Side conneting terminal cover (right & left 1 set) Front face screw terminal cover Loader connecting cable (RS-232C) 1 2 3 4 5 6 7 8 PUMZ* A A A A L 0 0 0 0 0 1 2 3 4 1 Digit [Table 1] Insulation block diagram Power Di1 to 4 Loader communication port Di5 to 8 RS-485 communication port Do1 to 4 Do5 to 8 Functional insulation (1000V AC) Functional insulation (500V AC) 4

OUTLINE DIAGRAM (Unit : mm) Front terminal cover (Option) (10) Base part (Main unit is detached) 30 Terminal block (at attach/detach) 85 Hole for screw mounting LOADER STATION 1.5 6 50 100 DIN rail 6.1 Terminal screw M3 Terminal screw M3 5 (8) (30) Hole for screw mounting At mounting to the DIN rail Main unit (at attach/detach) Locking tab Dimensions for screw mounting 2-M3 (30) 9±0.2 Notice at the installation Please keep the distance of 30mm from this instrument to radiate. [50mm is recommended] 30 or more (100) 88.5±0.2 (3) 30 or more +0.7 30 +0.2 5

- TERMINAL CONNECTION DIAGRAM Loader interface plug (RS-232C) 3 2 1 TX RX GND 2.5 3-pole miniature plug LOADER STATION Di4 Di3 Di2 Di1 24V DC 21 22 23 24 25 Digital input 1 to 4 21 22 23 24 25 11 12 13 14 15 Digital output 1 to 4 Transistor O.C. (SINK) 24V DC 11 L 12 L 13 L 14 L 15 COM Do1 Do2 Do3 Do4 Relay COM 11 Do1 12 Do2 13 Do3 14 Do4 15 Di8 Di7 Di6 Di5 24V DC 26 27 28 29 30 Digital input 5 to 8 26 27 28 29 30 16 17 18 19 20 Digital output 5 to 8 Transistor O.C. (SINK) 24V DC 16 L 17 L 18 L 19 L 20 COM Do5 Do6 Do7 Do8 Relay COM 16 Do5 17 Do6 18 Do7 19 Do8 20 Base part 1 2 Power 24V DC + 1 2 3 4 5 Communication RS485 3 4 5 A(+) B(-) SG 6

Operation parameter Run/Standby switch 0: Run 0 (RUN) 40021 1: Standby Digital input latch releases command 0: OFF 0 (OFF) 40022 1: Release latch Digital output latch releases command 0: OFF 1: Release latch 0 (OFF) 40023 Communication parameter RS-485 Parity setting 0: NONE 0 (NONE) 40111 1: ODD 2: EVEN RS-485 Response interval time 0 to 25 ( 20ms) 1 40113 RS-485 Communication permission 0: Read only 1 (R/W) 40114 1: Read/Write RS-485 Communication speed 0: 9.6kbps 1 (9.6kbps) 40115 1: 19.2kbps 2: 38.4kbps 3: Forbidden 4: 115.2kbps Enhanced communication module (PUMC) connection 0: PUMC not connected (RS485 Enable) 1: PUMC connected (RS485 Disable) 0 40116 Configuration parameter FAULT output set value 0: HOLD 0 (HOLD) 40260 1: OFF Standby output set value 0000 to FFFF 0000 40268 Standby mode setting 0: DI=Input value, DO=Standby output set value 0 40270 1: DI=All OFF, DO=Standby output set value LED2 Lamp Allocation 0 to 2 1 40222 7

DI parameter DI1 Input option 0 to 15 (bit data : 0000 to 1111) bit0 : LATCH bit1 : NOT bit2 : AND bit3 : OR 0 (bit data 0000) 40701 DI1 Input logic operation AND 0000 to 00FF 0000 40703 DI1 Input logic operation OR 0000 to 00FF 0000 40704 DI2 Input option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40705 DI2 Input logic operation AND 0000 to 00FF 0000 40707 DI2 Input logic operation OR 0000 to 00FF 0000 40708 DI3 Input option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40709 DI3 Input logic operation AND 0000 to 00FF 0000 40711 DI3 Input logic operation OR 0000 to 00FF 0000 40712 DI4 Input option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40713 DI4 Input logic operation AND 0000 to 00FF 0000 40715 DI4 Input logic operation OR 0000 to 00FF 0000 40716 DI5 Input option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40717 DI5 Input logic operation AND 0000 to 00FF 0000 40719 DI5 Input logic operation OR 0000 to 00FF 0000 40720 DI6 Input option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40721 DI6 Input logic operation AND 0000 to 00FF 0000 40723 DI6 Input logic operation OR 0000 to 00FF 0000 40724 DI7 Input option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40725 DI7 Input logic operation AND 0000 to 00FF 0000 40727 DI7 Input logic operation OR 0000 to 00FF 0000 40728 DI8 Input option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40729 DI8 Input logic operation AND 0000 to 00FF 0000 40731 DI8 Input logic operation OR 0000 to 00FF 0000 40732 8

DO parameter DO1 Output type 0 (Event output) 40401 DO1 Master module St. No. 0 to 255 0 40402 DO1 Master module Ch. No. 1 to 4 1 40403 DO1 BIT position 0000 to 00FF 0001 40404 DO1 Output option 0 to 15 (bit data : 0000 to 1111) bit0 : LATCH bit1 : NOT bit2 : AND bit3 : OR 0 (bit data 0000) 40405 DO1 Output logic operation AND 0000 to 00FF 0000 40407 DO1 Output logic operation OR 0000 to 00FF 0000 40408 DO1 Scaling base -100.0 to 100.0% 0.0 40409 DO1 Scaling span -100.0 to 100.0% 100.0 40410 DO1 Proportion cycle 1 to 120 sec. 30 40411 DO1 Lower limits 0.0 to 100.0% 0.0 40412 DO1 Upper limits 0.0 to 100.0% 100.0 40413 DO1 Limit type 0 to 3 0 40414 DO2 Output type 0 (Event output) 40415 DO2 Master module St. No. 0 to 255 0 40416 DO2 Master module Ch. No. 1 to 4 1 40417 DO2 BIT position 0000 to 00FF 0002 40418 DO2 Output option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40419 DO2 Output logic operation AND 0000 to 00FF 0000 40421 DO2 Output logic operation OR 0000 to 00FF 0000 40422 DO2 Scaling base -100.0 to 100.0% 0.0 40423 DO2 Scaling span -100.0 to 100.0% 100.0 40424 DO2 Proportion cycle 1 to 120 sec. 30 40425 DO2 Lower limits 0.0 to 100.0% 0 40426 DO2 Upper limits 0.0 to 100.0% 100.0 40427 DO2 Limit type 0 to 3 0 40428 DO3 Output type 0 (Event output) 40429 DO3 Master module St. No. 0 to 255 0 40430 DO3 Master module Ch. No. 1 to 4 1 40431 DO3 BIT position 0000 to 00FF 0004 40432 DO3 Output option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40433 DO3 Output logic operation AND 0000 to 00FF 0000 40435 DO3 Output logic operation OR 0000 to 00FF 0000 40436 DO3 Scaling base -100.0 to 100.0% 0.0 40437 DO3 Scaling span -100.0 to 100.0% 100.0 40438 DO3 Proportion cycle 1 to 120 sec. 30 40439 DO3 Lower limits 0.0 to 100.0% 0.0 40440 DO3 Upper limits 0.0 to 100.0% 100.0 40441 DO3 Limit type 0 to 3 0 40442 DO4 Output type 0 (Event output) 40443 DO4 Master module St. No. 0 to 255 0 40444 DO4 Master module Ch. No. 1 to 4 1 40445 DO4 BIT position 0000 to 00FF 0008 40446 DO4 Output option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40447 DO4 Output logic operation AND 0000 to 00FF 0000 40449 DO4 Output logic operation OR 0000 to 00FF 0000 40450 DO4 Scaling base -100.0 to 100.0% 0.0 40451 DO4 Scaling span -100.0 to 100.0% 100.0 40452 DO4 Proportion cycle 1 to 120 sec. 30 40453 DO4 Lower limits 0.0 to 100.0% 0.0 40454 DO4 Upper limits 0.0 to 100.0% 100.0 40455 DO4 Limit type 0 to 3 0 40456 9

DO parameter DO5 Output type 0 (Event output) 40457 DO5 Master module St. No. 0 to 255 0 40458 DO5 Master module Ch. No. 1 to 4 1 40459 DO5 BIT position 0000 to 00FF 0010 40460 DO5 Output option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40461 DO5 Output logic operation AND 0000 to 00FF 0000 40463 DO5 Output logic operation OR 0000 to 00FF 0000 40464 DO5 Scaling base -100.0 to 100.0% 0.0 40465 DO5 Scaling span -100.0 to 100.0% 100.0 40466 DO5 Proportion cycle 1 to 120 sec. 30 40467 DO5 Lower limits 0.0 to 100.0% 0.0 40468 DO5 Upper limits 0.0 to 100.0% 100.0 40469 DO5 Limit type 0 to 3 0 40470 DO6 Output type 0 (Event output) 40471 DO6 Master module St. No. 0 to 255 0 40472 DO6 Master module Ch. No. 1 to 4 1 40473 DO6 BIT position 0000 to 00FF 0000 40474 DO6 Output option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40475 DO6 Output logic operation AND 0000 to 00FF 0000 40477 DO6 Output logic operation OR 0000 to 00FF 0000 40478 DO6 Scaling base -100.0 to 100.0% 0.0 40479 DO6 Scaling span -100.0 to 100.0% 100.0 40480 DO6 Proportion cycle 1 to 120 sec. 30 40481 DO6 Lower limits 0.0 to 100.0% 0.0 40482 DO6 Upper limits 0.0 to 100.0% 100.0 40483 DO6 Limit type 0 to 3 0 40484 DO7 Output type 0 (Event output) 40485 DO7 Master module St. No. 0 to 255 0 40486 DO7 Master module Ch. No. 1 to 4 1 40487 DO7 BIT position 0000 to 00FF 0000 40488 DO7 Output option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40489 DO7 Output logic operation AND 0000 to 00FF 0000 40491 DO7 Output logic operation OR 0000 to 00FF 0000 40492 DO7 Scaling base -100.0 to 100.0% 0.0 40493 DO7 Scaling span -100.0 to 100.0% 100.0 40494 DO7 Proportion cycle 1 to 120 sec. 30 40495 DO7 Lower limits 0.0 to 100.0% 0.0 40496 DO7 Upper limits 0.0 to 100.0% 100.0 40497 DO7 Limit type 0 to 3 0 40498 DO8 Output type 0 (Event output) 40499 DO8 Master module St. No. 0 to 255 0 40500 DO8 Master module Ch. No. 1 to 4 1 40501 DO8 BIT position 0000 to 00FF 0000 40502 DO8 Output option 0 to 15 (bit data : 0000 to 1111) 0 (bit data 0000) 40503 DO8 Output logic operation AND 0000 to 00FF 0000 40505 DO8 Output logic operation OR 0000 to 00FF 0000 40506 DO8 Scaling base -100.0 to 100.0% 0.0 40507 DO8 Scaling span -100.0 to 100.0% 100.0 40508 DO8 Proportion cycle 1 to 120 sec. 30 40509 DO8 Lower limits 0.0 to 100.0% 0.0 40510 DO8 Upper limits 0.0 to 100.0% 100.0 40511 DO8 Limit type 0 to 3 0 40512 10

Internal DO data area parameter Internal DO data area 1 Event output 0 41001 Internal DO data area 2 1: ON 0 41002 Internal DO data area 3 0: OFF 0 41003 Internal DO data area 4 0 41004 Internal DO data area 5 Control output 0 41005 Internal DO data area 6 0.00 to 100.00 0 41006 Internal DO data area 7 0 41007 Internal DO data area 8 0 41008 Internal DO data area 9 0 41009 Internal DO data area 10 0 41010 Internal DO data area 11 0 41011 Internal DO data area 12 0 41012 Internal DO data area 13 0 41013 Internal DO data area 14 0 41014 Internal DO data area 15 0 41015 Internal DO data area 16 0 41016 Monitor parameter System FAULT status 0000 to FFFF - 30064 DO calculated result monitor 0000 to FFFF - 31002 DI calculated result monitor 0000 to FFFF - 31001 DI terminal monitor 0000 to FFFF - 31003 11

Fuji Electric Your distributor: Coulton Instrumentation Ltd 17 Somerford Business Park, Christchurch, BH23 3RU, UK Tel: +44 1202 480 303 E-mail: sales@coulton.com Web: www.coulton.com