Detailed Specifications & Technical Data

Similar documents
Part Number: 7940A Cat 6 DataTuff, (4 pr) 23 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor

Product Description. Product Specifications. Technical Specifications. Construction and Dimensions. Conductor: Insulation: Color Chart 1:

Part Number: 7965ENH Category 6 Nonbonded-Pair ScTP Cable

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

1672A. Product Description. Product Specifications. Technical Specifications. Conductor. APAC Standard. Bend Radius.

Detailed Specifications & Technical Data

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

Detailed Specifications & Technical Data

GenSPEED Category 5e Cables 3

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

GenSPEED 10 MTP Category 6A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk

GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

Dimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.

ACOM General Cable General Cable Canada

Mohawk Master Catalog

PREMIUM 5e F/UTP PRODUCTS

Table of Contents. Open Matrix System (OMS) 1-2

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

Volition TM Category 5e cable 100 Ω, FTP

CATEGORY 6A CABLING SOLUTIONS

COLORED CATEGORY 5e BULK CABLE, SOLID-CONDUCTOR PATCH CABLE, & CATEGORY 5e BACKBONE CABLE

STRUCTURED CABLING SYSTEMS (SCS)

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

Combining Value and Performance Like No One Else

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

ENTERPRISE COPPER SOLUTIONS

CATEGORY 6 CABLING SOLUTIONS

SHIELDED DIGITAL CABLES (1249C SERIES)

3M Mini D Ribbon (MDR) Cable Assembly

Compact Module. Category 6 FTP Cabling System

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

1 1/2 13.5, 625 JCASS)

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30

CATEGORY 6A CABLING SOLUTIONS

Category 5e F/UTP Euroclass D ca Cables

Gear up for the future.

Magic Patch Patch Leads & Accessories

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

CATEGORY 5e CABLING SOLUTIONS

FLAT AND ROUND CABLE PRODUCT DESCRIPTION DESIGN ADVANTAGES. IDC Systems Cable

Data Communication Products

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

PATCH CORDS, PLUGS & CABLES

Bus Cables & Industrial Ethernet Cables

CONTENTS. Product Guide 1. Multi Conductor Cable 11. Paired Cable 20. RS-232 Application Cable 27. RS-422 Application Cable 28

CATALOGUE PRODUCT CATALOGUE CCS CONNECTIVITY & CABLING SYSTEM STRUCTURED CABLING SYSTEM. is a trademark of:

Premise Installation Guide

MX5-F(XX)... Flat MAX module, T568A/B, rear strain relief cap

3M Supported Applications Map 100,000 (2005) Single-mode. Fiber. Multimode. Fiber. Copper

75 Ohm N Male Connector Crimp/Solder Attachment for RG6

IBDN Plus 25-Pair Cat5 UTP Cable

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

Scotch Heavy Duty Vinyl Electrical Tape 22

75 Ohm BNC Male Connector Crimp/Solder Attachment for PE-B159, 1855A, Mini 59

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

STRUCTURED CABLING SOLUTIONS

Siam Pacific Electric Wire & Cable Co., Ltd.

Cables for robot applications

Solarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China

17 Bulk Cables INSTRUMENT CABLES SS/ONE CS/535 CS/ SS/ONE SONIC SOLUTIONS HIGH DEFINITION INSTRUMENT CABLE MADE IN ITALY

FUTURE PROOF YOUR CONNECTIONS

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

Copper Solution Contents Cabinets Fiber Optic Solution

BUS UNITRONIC BUS CAN

HD-One DX/DX500 HDMI Extender

DINTEK LAN Cabling Systems

Ethernet Series. Etherplug Etherlink V Etherlink V Specialty Connectors Specifi cations...

Mining and Petrochemical Fiber Optic Cables

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Solutions for Electronic Specialty Markets (ESM)

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

What really changes with Category 6

Cat.6 4 Pair UTP Cable

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Continuous Flex Data Cable

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

System List. Structured Cabling System. In-Building RF Solution. Shield/Unshield 4pr Cable. Patch Panel. Multi-pair Cable. Patch Cord.

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

5O years of innovation and leadership.

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

RG-59/RG-6/RG-11 LSZH SERIES MAIN FEATURES

11-piece Electronic Tool Kit in Wallet. From only. Rapid Lead-Free Solder Wire 22SWG 0.7mm 100g Reel. From only 4.29

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION TESTING OF COPPER CABLES

Surface Mount Multilayer Ceramic Chip Capacitors for High Frequency

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Surface Mount Multilayer Ceramic Chip Capacitors for High Temperatures 200 C

Composite Extender USER MANUAL.

PRODUCT INFORMATION ETHERLINE PN FLEX. Info CPR: Article number choice under For Profinet applications Flexible use

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

3M Super 23 Electrical Tape

PRO Mixer Distro User Guide

AMERICAN NATIONAL STANDARD

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Transcription:

For more Information please call 1-800-Belden1 General Description: CAT6A (625MHz), 4-Pair, U/UTP-Unshielded, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, FEP Insulation, Patented Double-H Spline, Ripcord, Flamarrest Jacket Usage (Overall) Suitable Applications: Premise Horizontal Cable, 10 Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy Environments, PoE, PoE+ Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 4 23 Solid BC - Bare Copper Total Number of Conductors: 8 Insulation Insulation Material: Insulation Material FEP - Fluorinated Ethylene Propylene Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Flamarrest PVC - Polyvinyl Chloride Outer Jacket Ripcord: Overall Cable Overall Cabling Separator Material: Overall Nominal Diameter: Pair Pair Color Code Chart: Number Color 1 White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green 4 White/Brown Stripe & Brown Patented RoundFleX - Double H Cross-Web 7.493 mm Mechanical Characteristics (Overall) Storage Temperature Range: Installation Temperature Range: Operating Temperature Range: Bulk Cable Weight: Max. Recommended Pulling Tension: Min. Bend Radius/Minor Axis: -20 C To +75 C +5 C To +50 C -20 C To +75 C 56.552 Kg/Km 177.928 N 30.480 mm Page 1 of 5 01-30-2019

Min. Bend/Installation: 76.200 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP CEC/C(UL) Specification: EU Directive 2011/65/EU (ROHS II): EU CE Mark: EU Directive 2000/53/EC (ELV): EU Directive 2002/95/EC (RoHS): CMP EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): EU Directive 2003/11/EC (BFR): CA Prop 65 (CJ for Wire & Cable): MII Order #39 (China RoHS): Telecommunications Standards: Other Specification: Applicable Patents: Country www.belden.com/p Flame Test UL Flame Test: C(UL) Flame Test: CSA Flame Test: Suitability Suitability - Outdoor: Sunlight Resistance: Plenum/Non-Plenum Plenum (Y/N): Non-Plenum Number: Category 6A - TIA 568.C.2 C(UL)US CMP 105C OR (UL) CMP-LP (0.6A) OR CL3P-LP (0.6A) NFPA 262 Plenum Flame Test (UL910)(FT6) FT6 FT6 No No 10GX12 Electrical Characteristics (Overall) Nom. Mutual Capacitance: Capacitance (pf/m) 55.777 Maximum Capacitance Unbalance (pf/100 m): 50 Nominal Velocity of Propagation: VP (%) 68.000 Maximum Delay: Delay (ns/100 m) 537 @ 100MHz Typical Delay Skew: Delay Skew (ns/m) 114.835 Max. Delay Skew: Delay Skew (ns/100 m) 45 Page 2 of 5 01-30-2019

Maximum Conductor DC Resistance: DCR @ 20 C (Ohm/100 m) 7.400 Max. Operating Voltage - UL: Voltage 300 V RMS Maximum DCR Unbalanced: DCR Unbalance @ 20 C (%) 3.000 Electrical Characteristics-Premise (Overall) Premise Cable Electrical Table 1: Freq. (MHz) Max. Attenuation (db/100 m) Min. PSNEXT (db) Min. PSACR (db) Min RL (db) 1 2.100 73.3 71.2 20.000 4 3.800 64.3 60.5 23.000 8 5.300 59.8 54.4 24.500 10 5.900 58.3 52.4 25.000 16 7.500 55.2 47.8 25.000 20 8.400 53.8 45.4 25.000 25 9.400 52.3 43 24.300 31.25 10.500 50.9 40.4 23.600 62.5 15.000 46.4 31.4 21.500 100 19.100 43.3 24.2 20.100 200 27.600 38.8 11.2 18.000 250 31.100 37.3 6.3 17.300 300 34.300 36.1 1.9 16.800 350 37.200 35.1 16.300 400 40.100 34.3 15.900 450 42.700 33.5 15.500 500 45.300 32.8 15.200 550 47.700 32.2 14.900 600 50.100 31.6 14.700 625 51.200 31.4 14.500 750 56.700 30.2 14.000 860 61.200 29.3 13.600 Premise Cable Electrical Table 2: Freq. (MHz) Input (Unfitted) Imp. (Ohms) Fitted Impedance Min. PSACRF (db) 1 100+/- 15 105+/- 10 68.8 4 100+/- 15 100+/- 10 56.8 8 100+/- 15 100+/- 10 50.7 10 100+/- 15 100+/- 10 48.8 16 100+/- 15 100+/- 10 44.7 20 100+/- 15 100+/- 10 42.8 25 100+/- 15 100+/- 10 40.8 31.25 100+/- 15 100+/- 10 38.9 62.5 100+/- 15 100+/- 10 32.9 100 100+/- 15 100+/- 10 28.8 200 100+/- 22 100+/- 10 22.8 250 100+/- 32 100+/- 10 20.8 300 100+/- 32 100+/- 10 19.3 350 100+/- 32 100+/- 10 17.9 400 100+/- 32 100+/- 10 16.8 450 100+/- 32 100+/- 10 15.7 500 100+/- 32 100+/- 10 14.8 550 100+/- 32 100+/- 10 14.0 600 100+/- 32 100+/- 10 13.2 625 100+/- 32 100+/- 10 12.9 750 11.3 Page 3 of 5 01-30-2019

860 10.1 Premise Cable Electrical Table 4: Frequency (MHz) Min. PSANEXT (db) Min. PSAACRF (db) Min. TCL (db) Min. ELTCTL (db) 1.000 67.000 67.000 40.000 35.000 4.000 67.000 67.000 40.000 23.000 8.000 67.000 61.100 40.000 16.900 10.000 67.000 59.200 40.000 15.000 16.000 67.000 55.100 38.000 10.900 20.000 67.000 53.200 37.000 9.000 25.000 67.000 51.200 32.000 7.000 31.250 67.000 49.300 35.100 62.500 66.600 43.300 32.000 100.000 63.500 39.200 30.000 200.000 59.000 33.200 27.000 250.000 57.500 31.200 26.000 300.000 56.300 29.700 25.200 350.000 55.300 28.300 24.600 400.000 54.500 27.200 24.000 450.000 53.700 26.100 23.500 500.000 53.000 25.200 23.000 550.000 52.400 24.400 600.000 51.800 23.600 625.000 51.600 23.300 750.000 50.400 21.700 860.000 49.500 20.500 Notes (Overall) Notes: Jacket sequentially printed every 2 ft/1m. 0.295" cable dimension per TIA 6@1 equivalent diameter. Third party channel verified to TIA/EIA-568-C.2, Category 6a. Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 10GX13 D15Z1000 1,000 FT 0.000 BLUE CAT6A 4PR U/UTP CMP 10GX13 D151000 1,000 FT 43.000 LB BLUE CAT6A 4PR U/UTP CMP REEL 10GX13 D152500 2,500 FT 115.000 LB BLUE CAT6A 4PR U/UTP CMP REEL 10GX13 0041000 1,000 FT 43.000 LB YELLOW CAT6A 4PR U/UTP CMP REEL 10GX13 0042500 2,500 FT 115.000 LB YELLOW CAT6A 4PR U/UTP CMP REEL 10GX13 0045000 5,000 FT 215.000 LB YELLOW CAT6A 4PR U/UTP CMP REEL 10GX13 0051000 1,000 FT 43.000 LB GREEN, DARK CAT6A 4PR U/UTP CMP REEL 10GX13 0071000 1,000 FT 43.000 LB VIOLET CAT6A 4PR U/UTP CMP REEL 10GX13 0081000 1,000 FT 43.000 LB GRAY CAT6A 4PR U/UTP CMP REEL 10GX13 009Z1000 1,000 FT 49.000 LB WHITE CAT6A 4PR U/UTP CMP 10GX13 0091000 1,000 FT 43.000 LB WHITE CAT6A 4PR U/UTP CMP REEL 10GX13 010Z1000 1,000 FT 49.000 LB BLACK CAT6A 4PR U/UTP CMP 10GX13 0101000 1,000 FT 43.000 LB BLACK CAT6A 4PR U/UTP CMP REEL 10GX13 0101500 1,500 FT 64.500 LB BLACK CAT6A 4PR U/UTP CMP REEL Revision Number: 13 Revision Date: 10-17-2017 2019 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the Page 4 of 5 01-30-2019

compliance date may be in stock at Belden facilities and in our Distributor s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 5 of 5 01-30-2019