The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Similar documents
New Theatre Royal Lincoln Technical Information

DEREHAM MEMORIAL HALL

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Specification

HIRE AND TECHNICAL INFORMATION

The Haymarket Basingstoke Technical Specifications

Matt Dann Cultural Centre

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

INFORMATION FOR VISITING COMPANIES

Theatre Technical Specifications

Lighthouse Theatre Technical Specification

Main House Technical Specification

Dr JOHN GALLAGHER CONCERT CHAMBER

Technical Specification for the Alley Theatre, Strabane

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

The Lights Technical Guide June 2017

Theatre Technical Specification

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Technical Specifications Updated 01/10/2017. Stage

2017 TECHNICAL SPECIFICATIONS

Technical Information

Technical specifications Main theatre. Sound

Technical Specifications

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

Technical Information

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

MAIN AUDITORIUM TECHNICAL INFORMATION

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Technical Pack. Attenborough Arts Centre

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical Specification

Main House Technical Specifications

Technical Specification Pavilion Dance

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Technical Information

CENTRE FOR PERFORMING ARTS

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Technical Specification Ardhowen Theatre

Source 4 Junior Zoom Profile 575W 14 part of universal rig

Esso BHP Billiton Wellington Entertainment Centre

RPAC REDLANDS PERFORMING ARTS CENTRE

Mildura Arts Centre. Mildura Arts Centre Theatre. Technical Specifications. Updated 23/6/06

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

The Georgian Theatre Royal Technical Information For Visiting Companies

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Technical Specifications Nov 2016

JERWOOD VANBRUGH THEATRE

THE STREET THEATRE. Technical Specifications

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Main Stage Technical Specs - Hall #2

Technical Services and Specification

Arlington Arts Tech Spec 2018

MAIN THEATRE TECHNICAL SPECIFICATION

CHELSEA THEATRE. Technical Specifications

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Technical requirements & conditions for hirers

Technical Specification. Updated: April 2016

Technical Specification

John Leslie Theatre. Technical Specifications. Updated July 2018

Latrobe Performing Arts Centre

The Anvil Technical Specifications

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Technical Data Sheet

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Technical Specifications

Stage. Get In & Parking

Hopgood Theatre NOARLUNGA CENTRE

MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014

Technical Specification

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

Shouson Theatre Venue Specifications (updated Jan 2017)

ROSE THEATRE BASEMENT

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATIONS

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Technical Director of Production Andrew Quick Ext 252

Darlington Hippodrome Technical Specification

Tucker Theatre Policies and Procedures MTSU Department of Theatre 205 Boutwell Dramatic Arts Murfreesboro, TN 37132

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Hirers Technical Information Pack

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Cornerstone Technical Specifications 2018 / V1

Sandusky State Theatre Technical Specifications

TECHNICAL PACKAGE.

Concert Hall Technical Specifications

MAIN HOUSE TECHNICAL SPECIFICATION

DOMINO THEATRE INC. THEATRE TECHNICAL SPECIFICATIONS AND INFORMATION

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

Transcription:

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel- 07711710925 Email- pjwh15@msn.com The Tower Theatre has a seated capacity of 285 in the auditorium with 6 wheel chair positions. The box off has electronic ticketing. The foyer and bar have full Men s and Women s toilets the foyer also has a disabled toilet. The bar is able to accommodate 300 people with 100 seated at tables. The workshop has an extensive storage area including a workshop to the rear of the stage. The car park is flood lit and has 60 car parking spaces for up to 60 vehicles on tarmac. The grass area can be extended by another 15 vehicles; opposite the theatre the car parking space is ample on the road. Theatre Dimensions: Approx. Height to proscenium arch Height to flies Maximum flying height Maximum length of flown bars Number of fly lines Width of proscenium arch Width of stage With of apron Depth of apron (Form proscenium arch) Height of soft proscenium boarder (Adjustable +/- 1Mtr) Depth of stage from proscenium arch to back wall Width of Orchestra pit Depth of Orchestra pit Height of Orchestra pit Height of dock doors to scenery/workshop store* Width of dock doors to scenery/workshop store* 7.5Mtr 10Mtr 4. 9Mtr 14Mtr 7.5Mtr 10Mtr 12Mtr 3Mtr 2.2Mtr 1.5Mtr 4.6Mtr 1. Height of theatre access doors (Centre) 1.8-2Mtr

Width of theatre access doors 1.5Mtr Nothing higher or wider than these doors comes into the theatre! So worth a check- Not proven to be a problem so far. *Please Note- This is NOT the same as the access to the theatre Access is gained by the double doors from the North side of the building, leads though an entrance to the North wings and directly onto stage. The stage door is also on the North side of the building. IMPORTANT There is a 1Ton axial weight on the car parking outside the stage door. Dressing Rooms- There are 2 large dressing rooms, 1 mid sized dressing room also a large room on the 3 rd floor as an overflow. These are all located in the tower and are arranged on the 1 st and 2 nd floor all accessible by stairs. On the ground floor there is a small dressing room these are all on the North side of the building. A green room with part dressing room is on the North East of the building; this room has a Coffee vending machine. The stage door access is though this room. All dressing rooms have worktop, mirrors and high level 13A Sockets. To the rear of the North East and South East side of the building are single toilets on each side. Lighting Equipment Lighting Control and DMX- Light Factory V2.8 computer controlled DMX lighting 2 DMX512 (1990) universes, situated in the control to the rear of the seating. DMX runs to the two dimmer rooms and the fly tower. There is 3Pin DMX In & Out by the Stage Mangers desk. There is no DMX in the Auditorium and also NO RIGGERS CONTROL! Dimming- 104 channels of 0-100% dimmer channels. All are hard patched with the exception of 14 on stage high level 15A Round pin dips. All channels will do 2Kw max. All the bars are internally wired.

The dimmers are Sound Lab 6ch DMX dimmers and some Strand Tempus & JTM dimmers these are analogue and are run by two Sound Lab Demux units (72 Channels) Additional Power- There are two 63A CeeFORM sockets (Protected by 63A 30Ma RCD s) Socket A is on Yellow Phase and Socket B is on Blue Phase. They are South East stage side. 13A Sockets are located USL, USR, Stage Manager desk and fly floor. They all have RCD protection but are all only able to supply a max current of 16A per location. Please note The only sockets in the auditorium supply power to the speakers. How ever in the Mid Way point there is a 13A Un-Switched double socket. Permanent Fixed Rig- FOH 6x ADB Vision 1.2Kw profile spots arranged in the White, Orange, Magenta and blue colour scheme. Also 8x ADB Vision Fresnels in 2Kw, 4 per side on Vertical bars. Also there are approx 18 PAR64 Cans with 1Kw lamps. FOH- 2 Fixed suspended ladder truss all with 12 sockets per bar (2Kw Max) 4 booms two per side one horizontal and one vertical. On Stage- 4 Ladder truss bars with 400Kg winches which drop down to a working height each with 12x 15A Sockets. There are also dips on each side of the stage. Additional Lantern Stock- Profiles- 5x ETC Source 4 575w Profile spots 3x Strand Harmony 1Kw profile spots 2x Strand Prelude 500W Profile spots 1x CCT Silhouette 1Kw Profile spots Various PATT23 Lanterns all with 500/650W Lamps 1x Stand 808 2KW Profile Fresnels- 4x Strand PATT223 1Kw Fresnels 2 Strand PATT 743 2Kw Fresnels

Various PATT123 Lanterns PAR CANS- 24x PAR64 cans all with 1Kw Lamps 4x PAR56/64 cans- 300~1Kw Lamps Floods- 5x Strand CODA 500W 3Way CYC battens all with 15A In puts and Out puts to allow linking. Follow Spots- 2x Strand 1Kw C.S.I Metal Halide lamps Follow Spots these are mounted to the rear of the seating in permanent positions. There is also a 2Kw Halogen follow spot on a 13A plug. Misc- 2x DHA Gobo rotating holders 2x Fire effect wheels Various Gobos 1x Water Effects wheel 1x Elekralite MY250 250W discharge DMX Moving head 1x Elekralite MY150 150W Discharge DMX moving head Note- The moving heads run of 110V so are the be rigged by Theatre staff only. Working Light- All are 70W Metal Haidle floods. Onstage 2 on the First Bar (Front) and 2 on the 4 th bar (Rear) There are also 2 of these in the auditorium one per arch way. To the rear of the seating 2x 10W LED Floods light the tech area. FOH lights- There are 10 Dedicated PAR CANS for the audience light also with 6 uplighters. These are all on there own dimmer and have dedicated DMX channels. The Foyer- There is also now a 8 Channel PAR56 can lighting rig in the bar. Sound Equipment- Sound control is via a Allen and Heath GL2400 Mk.1 24Channel sound console. 24-4-2-4.

A 19 Rack is provided next to the GL2400 and this is loaded with a TasCam CD Player TasCam Mini Disk player 2x Alesis Stereo Compresser/Limiter/Gates 1x Alesis Stereo Graphic EQ 1x Alesis Microverb Digital FX Processor Mics- 4x Shure SM58 4x Shure SM57 5x Wharfdale Pro mics 6x Sennheiser G2 Wireless recivers and transmitters. 2x Sennheiser Shot gun mics 1x Shure Drum mic kit- 4 Tom/Snare. 1 Kick/Bass and 2 overheads Speakers are 2 RCF ART325 Active 400W FOH which are mounted Also 2 RCF ART310 Active 350W FOH which are mounted on the mid way arch and are used for the rear seating. Two HK Audio IL82 Monitors powered by a Peavey 8.5C 19 amplifier using SpeakON plugs. Flats and Masking- Soft Masking 3x Blue 1x9Mtr Boarders 1x Maroon Pelment. Appox a 3Mtr permanent top of the proscenium arch adjustable Pair of FOH tabs in Velvet 1x White CYC cloth 1x Light Blue CYC cloth We also have many other curtains tabs and various cloths please contact for the PDF file. Hard Masking- Various lengths (12-16Ft) 2ft, 4ft, 5ft and 6ft flats please ask for details. All the stated items in this spec sheet are subject to change please contact for further Information. We do try to keep as up to date as possible.