Cornerstone Technical Specifications 2018 / V1

Similar documents
Summary. Access and Parking

Arlington Arts Tech Spec 2018

Main House Technical Specification

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

TECHNICAL SPECIFICATIONS

Technical Specification

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Specification

Technical Specification Pavilion Dance

HIRE AND TECHNICAL INFORMATION

Theatre Technical Specification

DEREHAM MEMORIAL HALL

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

The Haymarket Basingstoke Technical Specifications

Main House Technical Specifications

Technical Specifications Updated 01/10/2017. Stage

CHELSEA THEATRE. Technical Specifications

New Theatre Royal Lincoln Technical Information

INFORMATION FOR VISITING COMPANIES

Technical Specification

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Theatre Technical Specifications

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Technical Specification for the Alley Theatre, Strabane

Stage. Get In & Parking

2017 TECHNICAL SPECIFICATIONS

Theatre Technical Specifications

Technical Specifications

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Dr JOHN GALLAGHER CONCERT CHAMBER

Technical Specification. Updated: April 2016

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Technical Specification Ardhowen Theatre

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Matt Dann Cultural Centre

TECHNICAL SPECIFICATIONS

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Technical Specifications Nov 2016

UNIVERSITY CONCERT HALL. Technical Specification

Pleasance London Main House Visiting Company Information Pack May 2017

CENTRE FOR PERFORMING ARTS

Technical Specifications

Concert Hall Technical Specifications

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Technical Information

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

Main Stage Technical Specs - Hall #2

Backstage Accommodation (Ground Floor Mezzanine Level 1 Floor above Loading Bay)

The Lights Technical Guide June 2017

Concert Hall Technical Specifications

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

John Leslie Theatre. Technical Specifications. Updated July 2018

332 fixed seats (max capacity) with reserved space for disable access

THE STREET THEATRE. Technical Specifications

Technical Specifications

Technical Specification

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

Darlington Hippodrome Technical Specification

RPAC REDLANDS PERFORMING ARTS CENTRE

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

JERWOOD VANBRUGH THEATRE

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

ISLAND HALL TECHNICAL INFORMATION

Tickets will be sold through our ABC account and all tickets are scannable on entry.

Technical specifications Main theatre. Sound

Dugdale Centre Technical Specification

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Technical Information

TECHNICAL SPECIFICATION

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Information for Incoming Companies

TECHNICAL RIDER. STAGE 32 m wide x 13 m deep (from setting line / mid point)

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

Technical Specification 2016

Technical Information

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

Technical Director of Production Andrew Quick Ext 252

Lighthouse Theatre Technical Specification

Technical Specifications. Taylor Little Theater

Salisbury Arts Centre Technical Specification v Page 1 of 7

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Latrobe Performing Arts Centre

MAIN AUDITORIUM TECHNICAL INFORMATION

Technical Data Sheet

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Technical Specifications

TECHNICAL SPECIFICATIONS

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

The Anvil Technical Specifications

Sandusky State Theatre Technical Specifications

ROSE THEATRE MAIN THEATRE

Transcription:

Cornerstone Technical Specifications 2018 / V1 Cornerstone is a purpose-built, professional arts, culture and entertainment venue in the heart of Didcot, brought to you by South Oxfordshire District Council. Opened in 2008, we present a high quality programme of live performance, participatory activities, exhibitions and outreach work that meet the needs and enhance the experiences of our local community, and beyond. Cornerstone comprises a 234-seat auditorium, café bar, gallery and four studios, perfect for dance and arts activities, as well as meetings. Please find Enclosed our technical Information. Should you have any questions please do not hesitate to contact one of our technical team. Page 1 of 8

Directions and Parking Postcodes: Front of Building = OX11 7NE Stage Door, Load-in and Parking = OX11 8RG We have a small service yard that can accommodate approximately eight cars. It is big enough to accommodate 7.5 ton to 18 ton rigid trucks, articulated lorries may struggle to park and advance notice would need to be given to accommodate them. The correct postcode for our service yard and parking is OX11 8RG. Access to the yard can be given by phoning the Duty Manager mobile 07801 203 544 Parking for all non-essential crew is via public car parks which are around two minutes walk away. Load-in is situated in the service yard and is via roller shutter doors. (3560mm width by 3900mm height). Auditorium Seated capacity is 217 or 234 with AA seating in. 350 can be accommodated with seating retracted and standing space (auditorium side). The stage is a proscenium arch format with black box masking. The Auditorium has a full air conditioning and heating system. Backstage Facilities On the ground floor off to stage right we have a very large green room with sofas, tea/coffee making, microwave, fridge and television. You are also welcome to use the washing machine and dryer along with ironing facilities. The green room has its own accessible toilet and there is another in the corridor adjacent to the green room. Off to stage right there are two large dressing rooms. Dressing room one has mirrored seating for seven along with a small sofa bed, accessible toilet and shower facilities. Dressing room two consists of mirrored seating for six along with accessible toilet and shower facilities. All dressing rooms have either on-suites or toilet facilities. There is lift Access to all floors backstage. We also have more dressing rooms available on request. Page 2 of 8

Access to stage Load-in is at ground level situated in the service yard and is via roller shutter doors. (3560mm width by 3900mm height). Its approximately 3 metres to the back of stage from the entrance. Stage STAGE AREA Front width with pros closed Front width with pros open On Stage width wall to wall Depth from back wall to Setting line Grid height with bars flown out MEASUREMENTS 8.5 meters 11.8 metres (Restricts LX Bars) 12.8 metres 6.6 meters 7.4 metres TABS Full Black Tabs (immovable) 1 Black legs 8 Black Border 2 White Cyclorama 1 Hard Masking 6 Prompt Corner We do not have a permanent Prompt Corner, but do have an LCD screen (with FOH camera feed) along with a stage management console (please request in advance) that has ROH calling along with cue light calling and comms master station. There is also access to the electronic FOH tab control system. Page 3 of 8

Flying We do not have live flying capabilities or a fly tower There are 11 Motorised bars (1-11) over the stage, and 1 manual bar (which is only to be used for the proscenium border). There are a further 5 motorised bars (12-16) over the audience seating. Each bar has a SWL of 250kg; this is not to be exceeded under any circumstances. There are no fixed flying points for flown PA or truss. We may be able to offer flying points off structural girders with advance notice and risk assessments. House tabs are operated independently of any of the fly-bars, and are motorised. We do have half tabs at approximately mid stage, these would need advance notice if they are to be moved, and these are operated by a manual pulley system. Bars highlighted in RED are immovable objects and part of our permanent rig BAR NUMBER DESCRIPTION General Equipment 1 Full Blacks Masking / White Cyclorama 2 LED BAR 4 3 LX BAR 4 (12 circuits) 4 PROJECTOR SCREEN 5 MID STAGE TABS 6 LED BAR 6 7 LX BAR 3 (12 Circuits) 8 LED BAR 8 9 LX BAR 10 (12 Circuits) 10 BORDER BAR ONLY 11 LX BAR 1 (11 circuits) 12 LED ADVANCE BAR 13 FOH BAR 1 (11 circuits) 14 FOH BAR 2 (12 Circuits) 15 SPARE 16 PROJECTOR BAR 8 x Techpro single channel coms packs with headsets 12 x Cue lights 1 x Stage managers desk including comms and cue light Master Station. RISERS QUANTITY 8ft * 4ft Litedeck 2 2m * 1m Litedeck 10 2m LiteDeck handrail 6 1m LiteDeck handrail 2 3 step Litedeck treads & handrails 1 1ft Aluminium Legs 40 2ft Aluminium Legs 48 Page 4 of 8

Access Equipment DESCRIPTION QUANTITY JLG P20DC Personnel Lift 8 metres 1 Zarges 10 Rung Skymaster 6.9 metres 1 Zarges 10 Rung Class 1 2.6 metres 2 Zarges 3 Rung Z600 0.6 metres 1 Lighting Equipment Lighting Fixtures Cornerstone s lighting grid and fixtures are all 16 Amp single phase 3-pin CEEFORM connectors. There are limited 16A-15A and 16A-13A converters available in house. Current set up is 2 x advanced FoH bars and 4x onstage bars; each bar contains 2 x six way IWB. Most dimmers are 3kw Cornerstone does have limited 5kw circuits available for larger fixtures; these are all at stage level. Cornerstone has 2 DMX universes available to use. We hold a very limited amount of gel in house, please contact us for a detailed list. Lantern Type Generic DTS Par62 Parcan 20 ETC Source 4 Par 750W 20 ETC Source 4 15/30 Zoom 20 ETC Source 4 25/50 Zoom 8 ETC Source 4 19 degrees 11 ETC Source 4 26 degrees 8 ETC Source 4 36 degrees 2 ETC Source 4 10 degrees 2 ETC Source 4 Jr 25-50 1 ADB F201 2kw Fresnel 4 ADB F101 1kw Fresnel 6 ADB F51 650w 6 ADB C51 650w 2 Spotlight Combi Fresnel 1kw 6 Intelligent Selador/ETC Vivid R 11 LED Flood 5 Martin Rush MH-6 Moving Led Wash 12 Martin Rush MH-5 Moving Led Profile 2 Pulse LEDBAR 320 6 SCROLLERS???????? Control ETC ION XE 20 1 ETC EOS 20 Fader Wing 1 ETC Congo Junior 1 ETC Congo Junior Fader Wing 1 Zero 88 ORB XF 1 ETC Smartfade 12/48 1 Page 5 of 8

Lighting Misc Unique 2.1 Hazer 1 Prolight Equinox Flame Machine 2 Tank Traps 2 Scaff Lengths (various heights) 6 Doughty G2036: Cine Hi-Combo - Max 2 Height: 3.16m - SWL: 30 Kg Doughty G2040: Lowboy Combo - Max 2 Height: 2.40m - SWL: 40 Kg DOUGHTY T43100 4 Lantern Tee Bar 4 Power (Touring) Cornerstone has one 63 Amp 3-phase supply, or two 32 Amp 3-phase supplies available for use by touring companies; these supplies are situated in the scene dock. There is no distro unit or 3-phase cable carried in house. This supply is independent of the other LX and sound circuits situated in the auditorium. Page 6 of 8

Sound Information The Front of House PA consists of: 2 x EM Acoustics i-12 Subwoofers and 2 x EM Acoustics EMS- 121 tops ground stacked either side of stage, as well as 2 x EM Acoustics tops flown inside of the proscenium arch, in front of the stage header. The system is governed by a DBX Venu 360.The system is driven by 3 x QSC PL236 amplifier. The system is limited to 100dBC via the DBX Venu. Please contact us if you need control over anything other than L/R inputs. Desk / Speakers / Amps Allen & Heath GLD 80 (with ipad control) 1 Allen & Heath AR2412 Stage box 1 Allen & Heath AR84 Expander 1 Allen & Heath QU SB 18/14 Mixer 1 DBX Venu 360 (FOH) 1 EM Acoustics EMS-121 (FOH) 4 EM Acoustics i-12 Subwoofers (FOH) 2 QSC PL236 amplifier (subs) 1 QSC PL236 amplifier (tops) 1 QSC PL236 amplifier (flown) 1 Monitors Logic Systems LM12 (400w) 4 Logic Systems LM15 (600w) 2 JBL JRX 112M (400w) 2 Monitor Amps Crown XTI 4002 2 QSC PL236 2 QSC PL218 1 QSC PLX 3602 1 Misc EM Acoustics i2 (Fills) 4 EM Acoustic i-8 subwoofer 2 Microphones/DI Shure SM58 4 Shure SM57 4 Shure SM Beta 58 4 Shure SM Beta 57 4 Neumann KMS105 1 AKG C100 3 Sennheiser 604e 4 AKG D112 2 AKG c451 EB 1 DI s Klark Teknik DN 100 Active 4 Emo single channel passive 6 Page 7 of 8

Stage Equipment 10-meter 16 way stage box with XLR 1 tails Tall boom mic stands 10 Short boom mic stands 2 Kick drum mic stands 2 Audio Visual All AV is patched through the house HDBaseT system using VGA/HDMI to Cat5 converters and the house CAT5 Installation. There are limited converters for Apple computers carried in house, please check in advance if your MAC is supported. In the auditorium, there is a Hitachi CP-WU8451 (5000 Lumen) on house bar 16, next to the technical box; there is a corresponding motorised screen flown on house bar 4. There is no shutter for the flown projector, although there is an inbuilt AV mute facility. We also have a selection of portable projectors (Epson EH-TW490) along with laptops which can be used subject to availability and possible re charges. Hearing loop & Show Relay Cornerstone has a Sennheiser Infrared hearing loop installed, and 10 headsets available from box office. We have a show relay which feeds from the auditorium into the backstage areas and the office. It is manually switched on by the duty technician prior to a show. Should you wish the show relay to be used, please inform the duty technician on the day of your performance. We appreciate you taking the time to read the Technical specs and lighting bar configuration. If you have any questions or queries, please do get in touch. Technical Department Name Position Telephone Email Grover William- Technical 01235 515 137 grover.hall@southoxon.gov.uk Hall Manager Dominic Bray Technician 01235 515 145 dominic.bray@southoxon.gov.uk Page 8 of 8